At least 1,027 records · Page 57

Validation of numerical simulations of activation by neutron flux - 15038

The knowledge of the radionuclide content of radioactive waste is of utmost importance for safety and waste management reasons. Numerical simulations are used at EDF-CIDEN to anticipate the dismantling and the radioactive waste management. The activation scheme by neutron flux developed at EDF-CIDEN comprises four steps. First of all, a 3 dimensional description of the reactor, the chemical composition of each structure, and the neutron sources at nominal power rating conditions are used as the input data to simulate the neutron propagation and to generate a 3 dimensional multi energy group neutron flux distribution in nominal power rating conditions. Secondly, this output data is used with the chemical compositions (including impurities) and the history of the operating conditions to calculate the radiological inventory for each structure. Thirdly, according to the radioactive inventory of each component or sub-component, a waste classification can be made; the classification criteria are based on the levels of radioactivity and radiotoxicity of 143 radionuclides. Finally, comparisons between the calculated radioactive inventories and the results of radio-chemical analyses can be made. These comparisons are made with regards to the activation of 'standard' chemical elements (meaning radionuclides being perfectly modeled with no uncertainty about the chemical concentrations). The results, linked with 'standard' chemical elements, can be used to validate the calculation scheme, including the neutron propagation, the neutron activation and all the other associated simplified assumptions (geometry, history of irradiation, etc). For steel, activation of 'Fe' is retained, and for stainless steel, activation of 'Fe' 'Ni' are retained. Overall, the feedback from Chooz A (Pressurized Water Reactor) shows that numerical simulations produce a slight overestimation of 'Fe-55' and 'Ni-63'. The results linked with minor chemical elements or impurities allowed us to validate the use of the average measured compositions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigations into validation of plutonium solutions for criticality safety analysis

Plutonium solution chemistry is among the most complex of all the elements in the periodic table. Under acidic conditions up to four different oxidation states can be present in significant amounts in a single solution. From the perspective of nuclear criticality safety, accurate information regarding the concentration of plutonium and other constituents in solution must be well-known in order to correctly model plutonium solution systems for analysis. This requires knowledge of the solution system along with the ability to make accurate assumptions and predictions of the chemical and physical properties of the solution system. If neutron transport methods are used to assess subcriticality in a nuclear criticality safety analysis, the models must be compared with benchmark experiments which are similar and the suitability of the computer code system must be quantified. This paper describes some investigations undertaken to support the validation of plutonium solution systems for nuclear criticality safety analysis and how the Whisper sensitivity/uncertainty (S/U) tool can provide information to support validation of such systems. Case study results for various solution systems such as aqueous plutonium nitrate, aqueous plutonium chloride and hypothetical metal-water mixture are presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results of TRIPOLI-4 version 10 on the TRIPOLI-4 criticality validation suite, thermal spectra

This paper presents the results of the latest version (version 10) of TRIPOLI-4 on its criticality validation suite, thermal spectra part. The criticality validation suite is made of 148 selected ICSBEP benchmarks with various enrichments, fissile materials and spectra. The ICSBEP benchmarks computational models are prepared by the TRIPOLI-4 team and are run in the same conditions for each benchmark: initial source, number of neutrons per cycle, number of inactive and active cycles, k{sub eff} estimator and nuclear data. Comparisons are made with experimental k{sub eff}. On one case (PST-009), we have noted a discrepancy between the computational results and the experiments. This discrepancy is also found with other codes, which might indicate a possible issue with the benchmark. For all the other considered cases, uranium and plutonium solutions and fuel-rods-arrays, the agreement with the experiments is very good.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementation and validation of a fully implicit accumulator model in RELAP-7

This paper presents the implementation and validation of an accumulator model in RELAP-7 under the framework of preconditioned Jacobian free Newton Krylov (JFNK) method, based on the similar model used in RELAP5. RELAP-7 is a new nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). RELAP-7 is a fully implicit system code. The JFNK and preconditioning methods used in RELAP-7 is briefly discussed. The slightly modified accumulator model is summarized for completeness. The implemented model was validated with LOFT L3-1 test and benchmarked with RELAP5 results. RELAP-7 and RELAP5 had almost identical results for the accumulator gas pressure and water level, although there were some minor difference in other parameters such as accumulator gas temperature and tank wall temperature. One advantage of the JFNK method is its easiness to maintain and modify models due to fully separation of numerical methods from physical models. It would be straightforward to extend the current RELAP-7 accumulator model to simulate the advanced accumulator design. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Systems usability case in stepwise control room validation - 125

We present a Systems Usability Case (SUC) approach enabling a requirement-based human factors evaluation of complex technical systems. The approach is especially suitable for stepwise verification and validation (V and V) of nuclear power plant (NPP) control room (CR) systems. A SUC is based on the Safety Case approach and on the Systems Usability (SU) construct. A series of V and V test activities carried throughout the design process and constructed according to SUC enables us to monitor how evaluation evidence is aggregated over variety of V and V steps and how the design solution is maturing towards a tool of a good quality and usability. The paper demonstrates an application of the SUC approach to real data from a stepwise CR validation. The results suggest that SUC has some clear advantages. It makes it easier to conduct the V and V activities in a more systematic fashion and it makes the reasoning process more explicit and transparent. Moreover, it enables building a longitudinal view of the progress of the design process. Most importantly, constructing the SUC enables monitoring of the fulfilment of the requirements from the human factors (i.e., SU) perspective. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Use of immersive 3D virtual reality environments in control room validations - 203

Advanced technologies (e.g., virtual and augmented reality) may provide new possibilities to facilitate control room (CR) design and evaluation activities. We studied how immersive 3D environments may augment and advance the evaluation of safety-critical CR systems. The 3D virtual reality (VR) CR was compared with a real-life development simulator environment where hardwired panels were substituted with Virtual panels. A multi-user functionality enables several operators to be and collaborate in the same VR CR environment at the same time. There is also a realistic representation of emergency operating procedures in the VR CR. Spatial audio communication through headsets makes the experience even more realistic. The results section of the paper address both technical and human factors issues associated with the use of immersive 3D VR environments in CR validation tests, e.g.: amount of technical resources required as compared to normal validation in a real-life simulator environment, creation of methodologically new testing opportunities and new opportunities to data registration and analysis. (authors)

47 OTHER INSTRUMENTATION↗

Development of a transient signal validation technique via a modified kernel regression model - 365

The demand for robust and resilient performance has led to the use of online-monitoring and signal validation techniques to monitor the process parameters and equipment conditions using several empirical models. One of these models is kernel regression (KR). Although KR is being used and performed excellently when applied to steady state, it has limitation in time-varying data that has several repetition of the same data point of the signals, especially if those signals are used to infer the other signals. In addition, many situations are related to variation and fluctuation during normal states, such as transient - start-up and shutdown mode. However, accurate estimation of the process signal can lead to the proper understanding of the equipment behaviours as well as enhance the online monitoring applications. In the sight of foregoing, this paper proposed a modified KR model, especially for transient signal validation to resolve the setback of conventional KR by improving the measure of similarities in the conventional KR. The performance of the proposed model is verified using both experimental data and the plant simulation data, and its results are compared with that of conventional KR. The results show that the proposed model has a greater robustness in particular situations compared to conventional KR, and it can be used to improve process and equipment monitoring applications. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantitative Analysis Guidance in Safety Software Validation

Quantitative analysis in software development has been a challenging topic over the years in safety software. While qualitative processes for vigorous safety software verification and validation (V and V) have been provided through standard such as IEEE 1012, quantitative analysis for V and V tasks such as correctness, completeness or accuracy evaluation have not been formally defined. In practice, there are quantitative analyses in terms of using software metrics. Many of these software metrics are useful in analyzing the test results. Some of them are used for providing guidance in code evaluation activities e.g. numbers of line of codes not exceeding certain limits, recursive calls are not allowed, etc. However, few can be used for providing quantitative analysis guidance for the V and V tasks such as completeness evaluation. AREVA Federal Services (AFS) has provided services for many nuclear projects in US. Through compliance with IEEE 1012, AFS V and V processes have provided vigorous qualitative processes ensuring quality level of the software products used in the project meeting the required nuclear software level. In addition, quantitative analysis is developed to provide structured validation framework ensuring 'zero defect' in the software products. This paper describes some aspects of the quantitative approaches using a sample safety application. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Criticality Analysis Capability of SuperMC with ICSBEP

SuperMC is a general purpose, intelligent and multifunctional, continuous energy Monte Carlo program for the design and safety evaluation of nuclear systems. It is designed to perform the comprehensive neutronics calculation, taking the radiation transport as the core and including the depletion, radiation source term/dose/biohazard, material activation and transmutation, etc. The latest version of SuperMC can perform the simulation of neutron, photon and coupled neutron and photon transport, and also equipped with the functions of automatic modeling and visualization. SuperMC has been verified by more than 2000 benchmark models and experiments including the handbook of International Criticality Safety Benchmark Evaluation Project (ICSBEP), the Shielding Integral Benchmark Archive Database (SINBAD), etc. The fusion reactor (ITER benchmark model, FDS Fusion Reactors), fast reactors (BN600, CLEAR-I), PWR reactors (HM, BEAVRS) and cases from the International Reactor Physics handbook Evaluation Program (IRPhEP) were employed for validating the comprehensive capability for reactor applications. In this paper, the validation of SuperMC based on the handbook of ICSBEP will be presented. ICSBEP, released by OECD/NEA, contains criticality safety benchmark specifications derived from experiments that were performed at various nuclear critical facilities around the world, which was widely used to verify neutronic codes and associated nuclear data libraries for criticality safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CFD Verification and Validation of Wire-Wrapped Pin Assemblies

TerraPower is participating in a cooperative project among industry, the national lab system, and academia to perform Verification and Validation (V and V) of Computational Fluid Dynamics (CFD) methods for predicting the flow and heat transfer within liquid-metal-cooled nuclear fuel assemblies with wire-wrapped fuel pins. This project, consisting of both experimental and numerical components, uses surrogate fluids and electrically heated fuel pins to substitute for the liquid metal coolant and the nuclear heat source. The experiments include both unheated assemblies to measure the flow velocities with Laser Doppler Velocimetry (LDV) and Particle Image Velocimetry (PIV), as well as heated assemblies to measure the temperatures of the fluid and the simulated fuel pins with thermocouples. Both sets of experiments also measure the pressure at multiple locations in the system. The numerical component of this work involves high-fidelity Large-Eddy Simulation (LES) modeling and industry-standard Reynolds-Averaged Navier-Stokes (RANS) modeling of the experiments. Furthermore, the experiments and simulations will be conducted on two duct geometries: the first is a non-deformed hexagonal duct that has flat internal duct faces that represents a beginning of life geometry. The other is a deformed duct where the internal hexagonal flow area enlarges then decreases along the axial height to represent the changes that occur to the duct geometry from pressure and irradiation effects in the core. This paper describes the methods and results of the industrial, RANS-based CFD code verification, solution verification, and solution validation. The V and V simulations are being performed for the following experiment test geometries: - Isothermal non-deformed bundle; - Heated non-deformed bundle; - Isothermal deformed bundle; - Heated deformed bundle. These flows have been computed at first with the pre-test design specifications, without the aid of any experimental results. Later, post-test calculations will be performed incorporating the actual test conditions and input from some of the experimental results. These RANS simulations of helically wire-wrapped fuel assemblies employ meshes of bare pins without the wire-wrap in the bundle. The effect of wire-wrap on the flow is accounted for by introducing a momentum source into the governing fluid equations. The momentum source is only applied to cells corresponding to the location of the wire-wrap, and its components in each cell are based on the local flow field. This methodology simplifies the geometry and mesh generation and reduces the cell count, while still capturing the effects of the wire-wrap. The momentum source approach is used for all of the assembly simulations performed in this study. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of COBRA-TF and STAR-CCM+ with Dakota 6.5 for CASL

High-to-low (Hi2Lo) is the process of using a validated high resolution code to generate synthetic data to improve a lower resolution code. The process is useful when generating additional experimental data is prohibitively expensive or impractical. The synthetic data from the high resolution code is treated as calibration data (with uncertainties and error bounds quantified) and is used to reduce uncertainty in the lower resolution code as well as train parameters that affect the solution accuracy. The future goal of this work is implementing a Hi2Lo workflow between STAR-CCM+ (STAR) and COBRA-TF (CTF) using Dakota. Synthetic data generated by STAR will be used with current experimental results to reduce the uncertainty in the CTF model. The scope of the results presented is validation of STAR and CTF models using experimental data provided by Westinghouse Electric Company (WEC). A companion paper describes the calibration work for CTF.

42 ENGINEERING↗

MITR RELAP5 Model Validations at Steady States and Transients

The Massachusetts Institute of Technology Reactor (MITR-II) is a 6 MW university research reactor designed primarily for experiments using neuron beams and in-core irradiation facilities, and education. The objective of this study is to validate the MITR RELAP5 model, which includes the reactor core, primary coolant loop, secondary coolant loop and heat exchanger models. Two sets of operational data were collected for validation. Steady-state data for 1 MW, 3 MW, 5.5 MW was obtained in the first test. The continuous startup transient data and the cooling tower outlet coolant temperature reduction obtained during the second test. The five steady-state conditions and two transient conditions were calculated by the RELAP5. The reactor power and cooling tower outlet temperature were used as boundary conditions while the reactor core inlet temperature and outlet temperature were calculated. A comparison was made between the modeling results and the temperature measurements. The results show that the MITR RELAP5 modeling results are in good agreement with measurement data for both steady-state and transient conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of the Computational Fluid Dynamics Method using the Aboveground Configuration of the Dry Cask Simulator

Dry cask applicants submit their spent nuclear fuel dry storage and transportation cask designs to the U.S. Nuclear Regulatory Commission (NRC) for certification under Title 10 of the Code of Federal Regulations (10 CFR) Part 72, 'Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste, and Reactor-Related Greater Than Class C Waste'. The NRC staff performs its technical review of these designs in accordance with 10 CFR Part 72 and NUREG-1536, 'Standard Review Plan for Spent Fuel Dry Storage Systems at a General License Facility,' Revision 1, issued July 2010. To ensure that the cask and fuel material temperatures of the dry cask storage system remain within the allowable limits or criteria for normal, off-normal, and accident conditions, the NRC staff performs a thermal review as part of the technical review. Recent applications increasingly have used thermalhydraulic analyses using computational fluid dynamics (CFD) codes (e.g., ANSYS FLUENT) to demonstrate the adequacy of the thermal design. The NRC performs validation studies of the FLUENT CFD code to assist it in making regulatory decisions to ensure adequate protection for storage and transportation casks. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. In efforts to further validate these designs, the NRC in conjunction with the Department of Energy and Sandia National Laboratories (SNL) are conducting an experiment to capture the effects of elevated helium pressures and accurately portray the external convection of aboveground and belowground canister dry cask systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spectral-average cross section validation in LR-0 reactor spectrum of {sup 55}Mn(n,2n), {sup 90}Zr(n,2n) and {sup 127}I(n,2n) reactions - 25362

This article deals with the validation of spectral average cross-sections (SACS) of {sup 55}Mn(n,2n){sup 54}Mn, {sup 90}Zr(n,2n){sup 89}Zr and {sup 127}I(n,2n){sup 126}I reactions in well-defined LR-0 reactor spectrum. The measurement of SACS for selected reactions is of high interest because they are used for the practical reactor dosimetry and also for refinement of prompt fission neutron spectra of {sup 235}U in the region of higher energies. Various experiments for description of neutron field in reactor and detector characterization, which are necessary for validation, are described. The spectral average cross-sections are derived from Net Peak Areas of irradiated samples measured using a semiconductor high purity germanium detector. The spectral average cross section in {sup 235}U prompt fission neutron spectrum was experimentally determined to be 0.239 ± 0.015 mb for {sup 55}Mn, 1.209 ± 0.052 mb for {sup 127}I and 0.107 ± 0.005 mb for {sup 90}Zr. The obtained results were compared with MCNP6 calculations using ENDF/B-VII.0, ENDF/B-VII.1, JEFF-3.1, JEFF-3.2, JENDL-3.3, JENDL-4, ROSFOND-2010, CENDL-3.1 and IRDFF-1.05 nuclear data libraries. Notable discrepancies were found in {sup 90}Zr(n,2n){sup 89}Zr and {sup 127}I(n,2n){sup 126}I reactions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of correlated data in validation procedures - 14483

The increasing demand on accuracy of criticality calculations leads to the question, how to treat correlated data of benchmark experiments correctly. Correlations in the process of validation arise for example if a configuration in a series of experiments shares certain components, e.g. fuel rods. Traditional methods of code validation do not treat correlations explicitly, but give a more conservative estimation of the bias. Including correlations can lead to a more precise estimation. In the work at hand, a method is discussed based on Bayes theorem to include correlations in the experimental data when estimating an application case k{sub eff}. After a short introduction to the applied method and the demonstration of the general capability of it to predict the k{sub eff} correctly, it is shown how the calculated k{sub eff} of an application case depends on correlations in experimental data for a simple Toy Model. The impact of ignoring correlations and taking to account lower and higher correlations is shown and discussed. Further results are shown using a database of correlated experimental data from the International Handbook of Criticality Safety Experiments to estimate the bias of two application cases. The experiments were chosen following the suggestion of the OECD/NEA EGUACSA Benchmark phase IV and consists of 21 experiments from the LEU-COMP-THERM series 007 and 039. With the extracted data results the calculated k{sub eff} values of the application cases are shown and discussed for different examples of correlations. The calculations were done by applying Monte-Carlo sampling methods with the GRS tool SUnCISTT, using ORNL's SCALE 6.1.2. This work discusses a possible way of treating correlations in the recalculation of critical experiments to get a more precise bias estimation of the used code system. It will be shown, that the presented method is capable to treat similarities in experimental setups of data used to calculate the bias correctly, independent of the size of similarities. The presented method is in principle capable of assessing regimes with little experimental data to estimate a bias. (authors)

42 ENGINEERING↗

PWR commercial reactor criticals as validation for spent fuel transport cask burnup credit - 14489

The burnup credit approach for a spent fuel transportation cask (SFTC) with a high density basket for 32 PWR fuel assemblies required credit not only for actinides but also for fission products, otherwise the required minimum burnups of fuel assemblies would have been too high to be practical. At the time of the development of the burnup credit methodology for this condition, no established approach existed to quantitatively validate credit for fission products. A validation approach was therefore developed specifically for this application, based on Commercial Reactor Criticals (CRCs). In this approach, hot critical state points of PWR plants were evaluated using the same codes that were used for the burnup credit evaluations for the transportation cask, namely CASMO-4 and MCNP4. A total of 36 of those state-points were analyzed, from 5 plants with two different assembly types. For each axial section of each fuel assembly, a separate CASMO-4 depletion analysis was performed, which required a total of about 4000 individual CASMO runs. The spent fuel compositions were then extracted from the CASMO runs and transferred to MCNP, where each core was modeled, considering the existing 1/8 symmetry. The core operating conditions were taken from work previously performed and documented for the Yucca Mountain project. The results of the MCNP calculations were then analyzed to establish bias and bias uncertainty values. Additional studies were performed to compare the in-core condition for the fuel with the condition that exists for the fuel in the spent fuel transport cask. The paper presents and discusses the results of the calculations, and the analysis of those results to establish bias and bias uncertainty values. The paper also presents results of the studies comparing in-core with transport cask conditions, and discusses the resulting limitations of this approach. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Addressing fission product validation in MCNP burnup credit criticality calculations - 14508

The US Nuclear Regulatory Commission (NRC) Division of Spent Fuel Storage and Transportation issued Interim Staff Guidance (ISG) 8, Revision 3 in September 2012. This ISG provides guidance for NRC staff members' review of burnup credit (BUC) analyses supporting transport and dry storage of pressurized water reactor spent nuclear fuel (SNF) in casks. The ISG includes guidance for addressing validation of criticality (k{sub eff}) calculations crediting the presence of a limited set of fission products and minor actinides (FP and MAs). Based on previous work documented in NRC Regulatory Guide (NUREG) Contractor Report (CR)-7109, the ISG recommends that NRC staff members accept the use of either 1.5 or 3% of the FP and MA worth - in addition to bias and bias uncertainty resulting from validation of k{sub eff} calculations for the major actinides in SNF - to conservatively account for the bias and bias uncertainty associated with the specified unvalidated FP and MAs. The ISG recommends (1) use of 1.5% of the FP and MA worth if a modern version of SCALE and its nuclear data are used and (2) 3% of the FP and MA worth for well qualified, industry standard code systems other than SCALE with the Evaluated Nuclear Data Files, Part B (ENDF/B),-V, ENDF/B-VI, or ENDF/B-VII cross sections libraries. The work presented in this paper provides a basis for extending the use of the 1.5% of the FP and MA worth bias to BUC criticality calculations performed using the Monte Carlo N-Particle (MCNP) code. The extended use of the 1.5% FP and MA worth bias is shown to be acceptable by comparison of FP and MA worths calculated using SCALE and MCNP with ENDF/B-V, -VI, and -VII-based nuclear data. The comparison supports use of the 1.5% FP and MA worth bias when the MCNP code is used for criticality calculations, provided that the cask design is similar to the hypothetical generic BUC-32 cask model and that the credited FP and MA worth is no more than 0.1 Δk{sub eff} (ISG-8, Rev. 3, Recommendation 4). (authors)

42 ENGINEERING↗

Nuclide inventory validation: radiochemical assay data quality and modeling challenges in benchmark models development

Oak Ridge National Laboratory is conducting radiochemical assay experiments, using high-precision analytical protocols validated with a comprehensive quality assurance plan, to expand the nuclide inventory validation basis for high burnup spent nuclear fuel. Preliminary measurement data for key actinides and fission products in two pressurized water reactor spent fuel samples are being used to investigate the impact of measurement data uncertainty on the sample burnup estimation. These measurement data are also being used to examine the impact of assumptions applied when developing best-estimate computational models to simulate fuel irradiation history. The simulations are being performed using depletion capabilities in the SCALE code system. Comparison of calculated and measured nuclide concentrations shows good agreement for the considered nuclides. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗