Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Quasi‐dynamic breathing model of the lung incorporating viscoelasticity of the lung tissue

Abstract We advanced a novel model to calculate viscoelastic lung compliance and airflow resistance in presence of mucus, accounting for the quasi‐linear viscoelastic stress–strain response of the parenchyma (alveoli) tissue. We adapted a continuum‐based numerical modeling approach for the lung, integrating the fluid mechanics of the airflow within individual generations of the bronchi and alveoli. The model accounts for elasticity of the deformable bronchioles, resistance to airflow due to the presence of mucus within the bronchioles, and subsequent mucus flow. Simulated quasi‐dynamic inhalation and expiration cycles were used to characterize the net compliance and resistance of the lung, considering the rheology of the mucus and viscoelastic properties of the parenchyma tissue. The structure and material properties of the lung were identified to have an important contribution to the lung compliance and airflow resistance. The secondary objective of this work was to assess whether a higher frequency and smaller volume of harmonic air flow rate compared to a normal ventilator breathing cycle enhanced mucus outflow. Results predict, lower mucus viscosity and higher excitation frequency of breathing are favorable for the flow of mucus up the bronchi tree, towards the trachea.

60 APPLIED LIFE SCIENCES↗

Mesoscale convective systems over the Amazon basin: The GoAmazon2014/5 program

The Green Ocean Amazon (GoAmazon2014/5) scientific program focused on the influence of aerosols and surface fluxes on tropical cloud formation. This major research effort gathered high-quality environmental data over the central Amazon basin during 2014 and 2015. The present work is a contribution to the GoAmazon2014/5 investigations with an emphasis on the behaviour of the most important mechanism of precipitation over the tropics: mesoscale convective systems (MCSs). To provide a background, MCSs' tracks obtained from infrared satellite images over the entire Amazon basin in 2014–2015 are compared with climatological values. We report the number of MCSs and precipitation in the basin is about 50% lower than compared to the climatology for 2000–2013. We argue that the below average occurrence of MCSs during the GoAmazon2014/5 program can be explained, at least in part, by the effects of positive anomalies in sea surface temperature over the equatorial Pacific Ocean, negative moisture transport toward the Amazon basin, and by the anticyclonic phase of the mode of interannual and intraseasonal variability over South America. Special attention is given to the 99 MCSs that occurred over the GoAmazon2014/5 site. The impact of MCSs on the meteorological variables over the GoAmazon2014/5 sites is examined, and the contribution of MCSs to rainfall over that region is estimated to be about 70% of the total. Finally, the synoptic and thermodynamic conditions related to the MCSs' genesis and dissipation are discussed. It is suggested that in days with reduced MCS genesis over the GoAmazon2014/5 region, the ventilation over the continent by easterly winds from the relative cold South Atlantic Ocean favours convection at locations near the ocean as compared to those inland.

54 ENVIRONMENTAL SCIENCES↗

Toxicological Potential of Cadmium Impact on Rainbow Trout (Oncorhynchus mykiss) in Early Development

Cadmium (Cd) is a toxic element widely distributed in the aquatic environment and producing a wide variety of harmful effects. In this study, the acute toxicity (96 h LC50) of Cd to rainbow trout Oncorhynchus mykiss embryos and larvae was determined. The obtained results showed that hatched larvae were the most sensitive to Cd exposure. After 4 days of exposure, embryos were found to have accumulated greater concentrations of Cd than larvae. Exposure to Cd at sublethal concentrations produced deleterious, exposure duration-related effects on biological parameters (mortality, heart rate and gill ventilation frequency) of larvae. Cd induced a significant elevation of all the studied geno- and cytotoxicity endpoints in larval erythroblasts.

54 ENVIRONMENTAL SCIENCES↗

Radiological patterns of secondary sclerosing cholangitis in patients after lung transplantation

Purpose: The purpose of this study was to investigate the radiological patterns of secondary sclerosing cholangitis (SSC) following lung transplantation. Methods: Fifty-five patients underwent abdominopelvic CT before and after lung transplantation for end stage pulmonary disease. Nine patients underwent MR cholangiopancreatography (MRCP). The radiological patterns of biliary abnormalities (location, bile duct dilatation with stricture, beaded appearance, and biliary casts/sludge), laboratory data (serum total bilirubin and alkaline phosphatase), and patient survival rates were evaluated. SSC was diagnosed when there were newly developed biliary abnormalities with cholestasis after lung transplantation. Potential perioperative risk factors pertaining to SSC were analyzed. Patient survival rates with or without SSC were compared. Results: Six of the 55 patients showed imaging and laboratory findings of SSC after lung transplantation. Multifocal dilatation and stricture involved the intrahepatic (6 of 6, 100%), hilar (4 of 6, 66.7%), and extrahepatic bile duct (1 of 6, 16.7%). On CT, the lesions presented as multifocal small cyst-like lesions along the bile duct course. On MRCP, the lesions showed beaded appearance with mild duct dilatation. Preoperative mechanical ventilation and bilateral lung transplantation were associated with SSC (p < 0.05). The median survival of patients with SSC was 4.6 months. Conclusion: Lung transplantation can induce SSC similar to SSC in critically ill patients, and result in worse clinical outcomes than in patients without SSC. Multifocal small cyst-like lesions along the intrahepatic bile duct on CT and beaded appearance on MRCP are suggestive findings of SSC in patients with cholestasis after lung transplantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Survey of Precipitation-Induced Atmospheric Cold Pools over Oceans and Their Interactions with the Larger-Scale Environment

Pools of air cooled by partial rain evaporation span up to several hundreds of kilometers in nature and typically last less than 1 day, ultimately losing their identity to the large-scale flow. These fundamentally differ in character from the radiatively-driven dry pools defining convective aggregation. Advancement in remote sensing and in computer capabilities has promoted exploration of how precipitation-induced cold pool processes modify the convective spectrum and life cycle. This contribution surveys current understanding of such cold pools over the tropical and subtropical oceans. In shallow convection with low rain rates, the cold pools moisten, preserving the near-surface equivalent potential temperature or increasing it if the surface moisture fluxes cannot ventilate beyond the new surface layer; both conditions indicate downdraft origin air from within the boundary layer. When rain rates exceed ~2 mm h –1, convective-scale downdrafts can bring down drier air of lower equivalent potential temperature from above the boundary layer. The resulting density currents facilitate the lifting of locally thermodynamically favorable air and can impose an arc-shaped mesoscale cloud organization. This organization allows clouds capable of reaching 4–5 km within otherwise dry environments. These are more commonly observed in the northern hemisphere trade wind regime, where the flow to the intertropical convergence zone is unimpeded by the equator. Here their near-surface air properties share much with those shown from cold pools sampled in the equatorial Indian Ocean. Cold pools are most effective at influencing the mesoscale organization when the atmosphere is moist in the lower free troposphere and dry above, suggesting an optimal range of water vapor paths. Outstanding questions on the relationship between cold pools, their accompanying moisture distribution and cloud cover are detailed further. Near-surface water vapor rings are documented in one model inside but near the cold pool edge; these are not consistent with observations, but do improve with smaller horizontal grid spacings.

54 ENVIRONMENTAL SCIENCES↗

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗

Energy savings potential from improved building controls for the US commercial building sector

The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sector energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29%; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.

Fernandez, Nick↗

From occupants to occupants: A review of the occupant information understanding for building HVAC occupant-centric control

Occupants are the core of the built environment. Traditional Heating, Ventilation, and Air-Conditioning (HVAC) systems operate with predefined schedules and maximum occupancy assumptions with no consideration of specific occupant information. These generalized assumptions usually do not align with the actual demand and result in over-conditioning and occupant discomfort. In recent years, with the aid of Information & Communication Technology (ICT) and Computer Science (CS), it is possible to acquire real-time and accurate occupant information to satisfy the exact thermal requirement through specific HVAC control in one particular built environment. This mechanism is called HVAC “Occupant-centric Control (OCC).” HVAC OCC strategy starts with collecting the occupant’s information (e.g., presence/absence) and then applies it to meet the occupant’s requirement (e.g., thermal comfort). However, even though some research studies and field pilot demonstrations have been devoted to the field of OCC, there is a lack of systematic knowledge about occupant data, which is the principal component of OCC for HVAC researchers and practitioners. To fill this gap, this review paper discusses OCC with a particular emphasis on occupant information and investigates how this information can assist HVAC operation in providing an acceptable built environment in required spaces during the required time. Finally, we provide a fine-grained, comprehensive picture of occupant information, discuss its features, the modalities of information feed-in into the HVAC control, and the application of commonly utilized occupant information for OCC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing occupant archetypes within urban low-income housing: A case study in Mumbai, India

Rapid urbanization pressure and poverty have created a push for affordable housing within the global south. The design of affordable housing can have consequences on the thermal (dis)comfort and behaviour of the occupants, hence requiring an occupant-centric approach to ensure sustainability. This paper investigates occupant behaviour within the urban poor households of Mumbai, India and its impact on their thermal comfort and energy use. This study is a first-of-its-kind attempt to explore the socio-demographic characteristics and energy-related behaviour of low-income occupants within Indian context. Three occupant archetypes, Indifferent Consumers; Considerate Savers; and Conscious Conventionals, were identified from the behavioural and psychographic characteristics gathered through a transverse field survey. A two-step clustering approach was adopted for occupant segmentation that highlighted considerable diversity in occupants’ adaptation measures, energy knowledge, energy habits, and their pro-environmental behaviour within similar socio-economic group. Building energy simulation of the representative archetype behaviour estimated up to 37% variations for air-conditioned and up to 8% variation for fan-assisted naturally ventilated housing units during peak summer months. The results from this study establish the significance of occupant factors in shaping energy demand and thermal comfort within low-income housing and pave way for developing occupant-centric building design strategies to serve this marginalized population. The developed low-income occupant archetypes would be useful for architects and energy modelers to generate realistic energy use profiles and improve building performance simulation results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hypothesis-Agnostic Network-Based Analysis of Real-World Data Suggests Ondansetron is Associated with Lower COVID-19 Any Cause Mortality

Background: The COVID-19 pandemic generated a massive amount of clinical data, which potentially hold yet undiscovered answers related to COVID-19 morbidity, mortality, long-term effects, and therapeutic solutions.Objectives: The objectives of this study were (1) to identify novel predictors of COVID-19 any cause mortality by employing artificial intelligence analytics on real-world data through a hypothesis-agnostic approach and (2) to determine if these effects are maintained after adjusting for potential confounders and to what degree they are moderated by other variables.Methods: A Bayesian statistics-based artificial intelligence data analytics tool (bAIcis®) within the Interrogative Biology® platform was used for Bayesian network learning and hypothesis generation to analyze 16,277 PCR+ patients from a database of 279,281 inpatients and outpatients tested for SARS-CoV-2 infection by antigen, antibody, or PCR methods during the first pandemic year in Central Florida. This approach generated Bayesian networks that enabled unbiased identification of significant predictors of any cause mortality for specific COVID-19 patient populations. These findings were further analyzed by logistic regression, regression by least absolute shrinkage and selection operator, and bootstrapping.Results: We found that in the COVID-19 PCR+ patient cohort, early use of the antiemetic agent ondansetron was associated with decreased any cause mortality 30 days post-PCR+ testing in mechanically ventilated patients.Conclusions: The results demonstrate how a real-world COVID-19-focused data analysis using artificial intelligence can generate unexpected yet valid insights that could possibly support clinical decision making and minimize the future loss of lives and resources.

60 APPLIED LIFE SCIENCES↗

Modeling of HVAC operational faults in building performance simulation

Operational faults are common in the heating, ventilating, and air conditioning (HVAC) systems of existing buildings, leading to a decrease in energy efficiency and occupant comfort. Various fault detection and diagnostic methods have been developed to identify and analyze HVAC operational faults at the component or subsystem level. However, current methods lack a holistic approach to predicting the overall impacts of faults at the building level—an approach that adequately addresses the coupling between various operational components, the synchronized effect between simultaneous faults, and the dynamic nature of fault severity. This study introduces the novel development of a fault-modeling feature in EnergyPlus which fills in the knowledge gap left by previous studies. This paper presents the design and implementation of the new feature in EnergyPlus and discusses in detail the fault-modeling challenges faced. The new fault-modeling feature enables EnergyPlus to quantify the impacts of faults on building energy use and occupant comfort, thus supporting the decision making of timely fault corrections. Including actual building operational faults in energy models also improves the accuracy of the baseline model, which is critical in the measurement and verification of retrofit or commissioning projects. As an example, EnergyPlus version 8.6 was used to investigate the impacts of a number of typical operational faults in an office building across several U.S. climate zones. Finally, the results demonstrate that the faults have significant impacts on building energy performance as well as on occupant thermal comfort. Finally, the paper introduces future development plans for EnergyPlus fault-modeling capability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automatic generation and simulation of urban building energy models based on city datasets for city-scale building retrofit analysis

Buildings in cities consume 30–70% of total primary energy, and improving building energy efficiency is one of the key strategies towards sustainable urbanization. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures (ECMs) for investment and the design of incentive and rebate programs. This paper presents the retrofit analysis feature of City Building Energy Saver (CityBES) to automatically generate and simulate UBEM using EnergyPlus based on cities’ building datasets and user-selected ECMs. CityBES is a new open web-based tool to support city-scale building energy efficiency strategic plans and programs. The technical details of using CityBES for UBEM generation and simulation are introduced, including the workflow, key assumptions, and major databases. Also presented is a case study that analyzes the potential retrofit energy use and energy cost savings of five individual ECMs and two measure packages for 940 office and retail buildings in six city districts in northeast San Francisco, United States. The results show that: (1) all five measures together can save 23–38% of site energy per building; (2) replacing lighting with light-emitting diode lamps and adding air economizers to existing heating, ventilation and air-conditioning (HVAC) systems are most cost-effective with an average payback of 2.0 and 4.3 years, respectively; and (3) it is not economical to upgrade HVAC systems or replace windows in San Francisco due to the city's mild climate and minimal cooling and heating loads. Furthermore, the CityBES retrofit analysis feature does not require users to have deep knowledge of building systems or technologies for the generation and simulation of building energy models, which helps overcome major technical barriers for city managers and their consultants to adopt UBEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An algorithm for optimal management of aggregated HVAC power demand using smart thermostats

Here, this paper presents an algorithm for optimal management of aggregated power demand of a group of heating, ventilating and air-conditioning (HVAC) units. The algorithm provides an advanced direct load control mechanism for HVACs that leverages the availability of smart thermostats, which are remotely programmable and controllable. The paper provides a theoretical basis and an optimal solution to the problem of cycling a large number of HVAC units while respecting customer-chosen temperature limits for the purpose of maximum load reduction. The problem is presented in a new light by transforming it into a job scheduling problem and is solved using a combination of a novel greedy algorithm and a binary search algorithm. By leveraging widespread availability of smart internet-based (also referred to as IoT-based) thermostats in today’s environment, the proposed approach can be readily applied to residential buildings without additional electrical/IT infrastructure changes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moore vs. Murphy: Tradeoffs between complexity and reliability in distributed energy system scheduling using software-as-a-service

Software-based optimization of building control strategies, including scheduling, has the potential to improve the performance of existing complex heating, ventilation, and air conditioning (HVAC), storage, and other systems—especially if temporally variable energy production, such as solar thermal or photovoltaics, is included. If reductions in energy bills can be achieved using optimized control strategies that take advantage of cost-saving opportunities, such as time-of-use pricing, the additional bill savings can cover further efficiency investment costs. As computer processing becomes cheaper over time (Moore's Law), opportunities to perform complex control optimization become more abundant, and these can be performed remotely as software-as-a-service (SaaS). However, by “perfecting” our control strategies, we run an increased risk that when something unexpected happens (Murphy's Law), the consequences of failure are greater. This study used simulation to explore the potential benefits of HVAC schedule optimization, delivery, and implementation using a SaaS paradigm, at various levels of complexity. Implementing optimal schedules in a model of an efficient building's HVAC system, the study predicts energy cost savings of up to 10% compared to the naïve reference control strategy. Optimizing more system control variables increases the potential energy cost savings; however, these savings could be compromised by failures in communication inherent in delivering schedules via SaaS. The additional cost of energy resulting from the risk of increased demand charges generally increased with increased communication failure to a much larger extent than the risk of increased energy use charges. This work suggests that moderate improvements in performance, achieved at low cost by simple means, may be more effective than highly optimized schemes, which are more susceptible to failure due to their dependence on complex interactions between systems.

42 ENGINEERING↗

Distributed energy management for community microgrids considering network operational constraints and building thermal dynamics

A distributed energy management system for community microgrids is developed here. Unlike a centralized optimization-based energy management system, it schedules distributed energy resources and energy storage systems, as well as residential appliances, indirectly through iterative interaction between the microgrid central controller and home energy management systems, based on price signals. In each iteration, the microgrid central controller adjusts the scheduling of distributed energy resources and energy storage systems at the microgrid level. Meanwhile, the home energy management system of each house adjusts the scheduling of residential appliances. Then, the energy price at each bus is updated according to the unbalanced power between generation and demand. The optimization converges when the unbalanced power of all buses is close to zero, i.e., the microgrid central controller and home energy management systems reach an agreement on the energy price and generation/consumption. In particular, a detailed thermal dynamic model of the house is integrated into the HEMS scheduling for intelligent control of the heating, ventilation, and air-conditioning system by customers. Lastly, the distribution network is also considered to make the energy price signal locational. Results of case studies validate the efficacy of the proposed distributed energy management system.

24 POWER TRANSMISSION AND DISTRIBUTION↗