Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VELOCITY MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Experimental results on a wall interference correction method with interface measurements

A wall interference assessment and correction method for subsonic two-dimensional wind tunnel testing is presented. This method calculates a pressure coefficient and angle of attack correction based on velocity measurements on interfaces inside of the wind tunnel. A mathematical representation of the test article is not required. An experimental verification of the suggested technique is given. A NACA 0012 airfoil is tested at a Mach number of 0.70 and at two different angles of attack. Calculated blockage corrections show reasonable agreement with results based on Hackett's method. Corrected surface pressures compare favorably to free-air flow field data if the tunnel flow field is subsonic. The present wall interference correction method can be applied to transonic tunnel flow fields with some restrictions. Errors are estimated and it is shown that the expected error in calculating the pressure coefficient correction on the model surface is in the order of the error of pressure coefficient measurement on interfaces. Necessary testing equipment in existing tunnels can easily be modified if the present method is applied.

Lo, C. F.↗

Sweeping Jet Actuator in a Quiescent Environment

This study presents a detailed analysis of a sweeping jet (fluidic oscillator) actuator. The sweeping jet actuator promises to be a viable flow control actuator candidate due to its simple, no moving part structure and its high momentum, spatially oscillating flow output. Hot-wire anemometer and particle image velocimetry measurements were carried out with an emphasis on understanding the actuator flow field in a quiescent environment. The time averaged, fluctuating, and instantaneous velocity measurements are provided. A modified actuator concept that incorporates high-speed solenoid valves to control the frequency of oscillation enabled phase averaged measurements of the oscillating jet. These measurements reveal that in a given oscillation cycle, the oscillating jet spends more time on each of the Coanda surfaces. In addition, the modified actuator generates four different types of flow fields, namely: a non oscillating downward jet, a non oscillating upward jet, a non oscillating straight jet, and an oscillating jet. The switching from an upward jet to a downward jet is accomplished by providing a single pulse from the solenoid valve. Once the flow is switched, the flow stays there until another pulse is received. The oscillating jet is compared with a non oscillating straight jet, which is a typical planar turbulent jet. The results indicate that the oscillating jet has a higher (5 times) spreading rate, more flow entrainment, and higher velocity fluctuations (equal to the mean velocity).

Koklu, Mehti↗

Time-lens photon Doppler velocimetry (TL-PDV)

Here, we describe a time lens (TL) to expand the dynamic range of photon Doppler velocimetry (PDV) systems. The principle and preliminary design of a TL-PDV system are explained and shown to be feasible through simulations. In a PDV system, an interferometer is used for measuring frequency shifts due to the Doppler effect from the target motion. However, the sampling rate of the electronics could limit the velocity range of a PDV system. A four-wave-mixing (FWM) TL applies a quadratic temporal phase to an optical signal within a nonlinear FWM medium (such as an integrated photonic waveguide or a highly nonlinear optical fiber). By spectrally isolating the mixing product, termed the idler, and with appropriate lengths of dispersion prior to and after this FWM TL, a temporally magnified version of the input signal is generated. Therefore, the frequency shifts of PDV can be “slowed down” with the magnification factor M of the TL. M = 1 corresponds to a regular PDV system without a TL. M = 10 has been shown to be feasible for a TL-PDV system. The use of this effect for PDV can expand the velocity measurement range and allow for the use of lower bandwidth electronics. TL-PDV will open up new avenues for various dynamic material experiments.

47 OTHER INSTRUMENTATION↗

Universal calculation formula and calibration method in Fourier transform profilometry

We propose a universal calculation formula of Fourier transform profilometry and give a strict theoretical analysis about the phase-height mapping relation. As the request on the experimental setup of the universal calculation formula is unconfined, the projector and the camera can be located arbitrarily to get better fringe information, which makes the operation flexible. The phase-height calibration method under the universal condition is proposed, which can avoid measuring the system parameters directly. It makes the system easy to manipulate and improves the measurement velocity. A computer simulation and experiment are conducted to verify its validity. The calculation formula and calibration method have been applied to measure an object of 22.00 mm maximal height. The relative error of the measurement result is only 0.59%. The experimental results prove that the three-dimensional shape of tested objects can be reconstructed exactly by using the calculation formula and calibration method, and the system has better universality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Particle Flux Measurements during TRACER (TRACER PFM) (Field Campaign Report)

The purpose of this campaign was to deploy an instrument payload collocated with a suite of in situ and remote-sensing aerosol instruments at the urban site at the La Porte, Texas Municipal Airport during the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) in Houston, Texas. The payload was designed to characterize the physicochemical properties, mixing state, and size-resolved vertical fluxes of aerosols. Deployed aerosol instruments associated with the flux measurements included three condensation particle counters (CPCs) with different lower cutoff diameters ( D > 2.5 nm, D > 10 nm, and D > 40 nm), a single-particle soot photometer (SP2) measuring refractory black carbon, and a portable optical particle spectrometer (POPS) measuring the optical size distribution (~180 nm < D < ~5000 nm). A 10-m flux tower hosted a sonic anemometer (SONIC) for vertical velocity measurements. In addition, a humidified tandem differential mobility analyzer (HTDMA) was deployed to measure the growth factors and hygroscopicity parameter of 15-50 nm-sized particles in order to constrain the composition of compounds responsible for modal aerosol growth during new particle formation/growth events. Finally, a radial differential mobility analyzer (RDMA) was deployed to extend the size distribution measurement to 5 nm.

54 ENVIRONMENTAL SCIENCES↗

Optical study of a possible bipolar flow associated with Herbig-Haro 12

The region near HH 12 in NGC 1333 has been imaged at V, R, I, and H-alpha using the CCD detector at the Kitt Peak National Observatory 0.9 m telescope. The H-alpha frame reveals a narrow, sinuous structure which extends over a projected distance of 0.3 pc and which emanates from a star which appears to be a T Tauri object of type M0-M2. Velocities along this structure were obtained both north and south of the star. The morphology of this structure as well as the measured velocities suggest that it may be an optical manifestation of a highly collimated bipolar outflow which excites the object heretofore identified as HH 12.

Strom, K. M.↗

Phase-resolved IUE observations of AM Herculis system E1405-451

The first phase-resolved IUE observations of the AM Herculis system E1405-451 is reported. The spectra show bright emission lines from N V, C IV, and He II, whose centroids vary drastically during the 101.5 minute period. The radial velocities measured from the line centroids show a sinusoidal variation with a semiamplitude of 300 km/s. An explanation for the observed emission line velocities is considered using a model for the system having inclination i = 60 deg and magnetic colatitude Delta = 20 deg.

Takalo, L. O.↗

Measurement and modeling of dispersive pulse propagation in draw wire waveguides

An analytical model of dispersive pulse propagation in semi-infinite cylinders due to transient axially symmetric end conditions has been experimentally investigated. Specifically, the dispersive propagation of the first axially symmetric longitudinal mode in thin wire waveguides, which have ends in butt contact with longitudinal piezoelectric ultrasonic transducers, is examined. The method allows for prediction of a propagated waveform given a measured source waveform, together with the material properties of the cylinder. Alternatively, the source waveform can be extracted from measurement of the propagated waveform. The material properties required for implementation of the pulse propagation model are determined using guided wave phase velocity measurements. Hard tempered aluminum 1100 and 304 stainless steel wires, with 127, 305, and 406 micron diam., were examined. In general, the drawn wires were found to behave as transversely isotropic media.

Madaras, Eric I.↗

Measurement and Modeling of Dispersive Pulse Propagation in Drawn Wire Waveguides

An analytical model of dispersive pulse propagation in semi-infinite cylinders due to transient axially symmetric end conditions has been experimentally investigated. Specifically, the dispersive propagation of the first axially symmetric longitudinal mode in thin wire waveguides, which have ends in butt contact with longitudinal piezoelectric ultrasonic transducers, is examined. The method allows for prediction of a propagated waveform given a measured source waveform, together with the material properties of the cylinder. Alternatively, the source waveform can be extracted from measurement of the propagated waveform. The material properties required for implementation of the pulse propagation model are determined using guided wave phase velocity measurements. Hard tempered aluminum 1100 and 304 stainless steel wires, with 127, 305, and 406 micron diam., were examined. In general, the drawn wires were found to behave as transversely isotropic media.

Madaras, Eric I.↗

Multiple-Point Mass Flux Measurement System Using Rayleigh Scattering

A multiple-point Rayleigh scattering diagnostic is being developed to provide mass flux measurements in gas flows. Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous density, temperature, and velocity measurements. Rayleigh scattered light from a focused 18 Watt continuous-wave laser beam is directly imaged through a solid Fabry-Perot etalon onto a CCD detector which permits spectral analysis of the light. The spatial resolution of the measurements is governed by the locations of interference fringes, which can be changed by altering the etalon characteristics. A prototype system has been used to acquire data in a Mach 0.56 flow to demonstrate feasibility of using this system to provide mass flux measurements. Estimates of measurement uncertainty and recommendations for system improvements are presented

Mielke, Amy F.↗

Simulation and Modeling of Hypersonic Turbulent Boundary Layers Subject to Favorable Pressure Gradients due to Streamline Curvature

Direct numerical simulations (DNS) of favorable-pressure-gradient turbulent boundary layers are presented for a nominal freestream Mach number of 5, with the objective of assessing the limitations of the currently available Reynolds-averaged Navier-Stokes (RANS) models. The favorable pressure gradient is induced by the streamwise curvature of the two-dimensional, planar, convex measurement surface used during experiments at the Texas A&M University. The DNS data shows good comparison with the measured velocity profiles, strain rates, and some, but not all, of the Reynolds-stress components. The discrepancies between the predicted and the measured wall-normal as well as shear stress components are primarily attributed to the lower than actual values inferred from typical PIV measurements of turbulent boundary layers. The DNS data shows a zero or slightly negative Reynolds shear stress in the outer part of the boundary-layer, which is indicative of the decaying turbulent motion under a strong favorable pressure gradient. The DNS data is also compared with the results of RANS computations based on commonly used zero, one, and two equation eddy-viscosity models. The RANS models yield reasonable comparisons with the DNS-based skin friction under zero and weak pressure gradients, but significant discrepancies under a strong pressure gradient. The k-w SST model provided the best overall predictions of skin friction, except in the region where the flow transitions from a favorable to an adverse pressure gradient. While the RANS models examined herein also give good predictions of the Reynolds shear stress under a sufficiently weak pressure gradient, none of those models are able to appropriately capture the reduction in the Reynolds stresses when the flow was subjected to a strong pressure gradient. An a priori assessment of the turbulent heat-flux prediction based on the assumption of a constant turbulent Prandtl number with the DNS data shows that while the constant turbulent Prandtl number model is effective in predicting the wall-normal component of turbulent heat flux, it does not capture the turbulent heat transfer in the streamwise direction for all the pressure gradient cases. The failure of the constant turbulent Prandtl number model highlights a requirement for more advanced models of the turbulent heat flux.

turbulent boundary layers↗

Two-Line Focused Laser Differential Interferometry of a Flat Plate Boundary Layer at Mach 6

Flat plate models are often used in wind tunnel testing to make measurements of the boundary layer, but preclude the use of conventional focused laser differential interferometry (FLDI) measurements, particularly for measurements at the surface of the model. By instead focusing light in only one direction using cylindrical optics, as opposed to two directions using only spherical optics, FLDI measurements can be made without truncating the beam at the model edges. Measurements at discrete points along a line can also be acquired, effectively acting as many individual FLDI instruments in a single measurement. Here, a two-line FLDI system has been constructed that allows for the measurement lines to be easily oriented at any azimuthal angle about the optical axis since the optics are housed in rotation mounts. Velocity measurements at points along a line or between two lines are also possible, since the beams are split similar to the two-point FLDI instrument. The system was first characterized in the laboratory using a laser-induced breakdown spark to provide a well-defined density fluctuation, along with high-speed schlieren measurements for comparison. The system was then installed at the NASA Langley 20-Inch Mach 6 Air Tunnel to make measurements through the boundary layer of a flat plate model and in the tunnel freestream.

Joshua M Weisberger↗

Particle Image Velocimetry Measurements in a Wire-Wrapped 61-Pin Hexagonal Fuel Bundle

Liquid metal fast reactor fuel assemblies using sodium as a coolant typically utilize a tightly packed triangular lattice of fuel pins enclosed in a hexagonal duct. The fuel pins are typically wrapped with a helical wire spacer. The primary function of the wire spacers is to maintain a gap between neighboring fuel pins. They also mitigate vortex-induced vibration and enhance sub-channel mixing to increase convective heat transfer. Many experiments have been performed to study thermal-hydraulic characteristics, primarily pressure drops, of the wire-wrapped fuel bundles. Novendstern developed a semi-empirical model to predict pressure losses in a hexagonal array of wire-wrapped pins in the turbulent flow regime. Rehme proposed pressure drop correlations for a wide range of geometrical parameters, such as pitch-to-diameter ratio P/D from 1.125 to 1.417, lead-to-wire diameter ratio H / dm from 6 to 45, and number of pins n from 7 to 61. Cheng and Todreas introduced their hydrodynamic models for subchannel friction factors and mixing parameters in a 37-pin fuel bundle, which covered the laminar, transition and turbulent flow regimes. Computational fluid dynamics (CFD) offers an opportunity to validate the above correlations and investigate the flow characteristics in the subchannels. Several numerical studies of the wire-wrapped fuel bundles have been performed and most of them are Reynolds-Averaged Navier-Stokes (RANS) based simulations with various turbulence models. Ahmad and Kim performed RANS simulations of 7- and 19-pin bundles using the k-omega SST turbulent model, while Gajapathy et al. performed RANS simulations on 7-pin bundles using the k-epsilons model. Recently, Fischer et al. carried out large-eddy simulation (LES) calculations on wire-wrapped fuel bundles to obtain higher-resolution numerical solutions of subchannel behavior. The geometrical complexity of the hexagonal wire-wrapped fuel bundle has limited experimental activities to pressure drop measurements. A database of pressure drops and flow-field measurements in a 61-pin wire-wrapped hexagonal fuel bundle is not available to benchmark the existing correlations and validate the CFD calculations. Texas A and M University is conducting isothermal flow experiments in a wire-wrapped 61-pin hexagonal fuel bundle to support the research on advanced nuclear fuel development sponsored by the Department of Energy (DOE). The purpose of these tests is to perform high spatial and temporal resolution measurements of the flow and pressure measurements at different locations in the fuel bundle. The experimental facility employs matched-index-of-refraction (MIR) techniques and laser diagnostic velocity measurement techniques such as particle image velocimetry (PIV) and laser Doppler velocimetry (LDV). The result of this experimental activity will be an experimental database of pressure and flow-field measurements that will be suitable for validating CFD computer codes. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rotation Measurement

In aircraft turbine engine research, certain investigations require extremely precise measurement of the position of a rotating part, such as the rotor, a disc-like part of the engine's compressor which revolves around a shaft at extremely high speeds. For example, in studies of airflow velocity within a compressor, researchers need to know-for data correlation the instantaneous position of a given spot on the rotor each time a velocity measurement is made. Earlier methods of measuring rotor shaft angle required a physical connection to the shaft, which limited the velocity of the rotating object.

Source record↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Evaluation of a new DIII-D Doppler backscattering system for higher wavenumber measurement and signal enhancement

The high density fluctuation poloidal wavenumber, k θ (k θ > 8 cm –1 , k θ ρ s > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k’s. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher k θ (>8 cm –1 ) is substantially reduced, making it difficult to measure higher k θ turbulence. The new DBS system has been optimized to access higher wavenumber, k θ ≤ 20 cm –1 , density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe’s sensitivity to high-k density fluctuations has been increased by approximately an order of magnitude compared to the old system that has been in use at DIII-D. Note that typical measurement locations are above or below the tokamak midplane on the low field side with normalized radial ranges of 0.5–1.0. As a result, the new DBS probe system with the toroidal matching of fluctuation wave vectors is thought to be critical to understanding high-k turbulent transport in fusion-relevant research at DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow-Field Measurements in a Wing-Fuselage Junction Using an Embedded Particle Image Velocimetry System

A novel, embedded, 2D Particle Image Velocimetry system has been developed and implemented to obtain off-body velocity measurements in the junction of an 8% wing-body configuration in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. Although the initial purpose for implementing the system during this test was to evaluate system performance and identify potential risks, the system worked remarkably well and a considerable amount of data were obtained in the wing-fuselage junction near the trailing edge at a Reynolds Number of 2.4 Million and angle of attack of 5 degrees. In addition to providing notable efficiencies with regard to image acquisition and test operations, the PIV system proved to be quite capable of capturing unique details of the flow separation to complement the extensive suite of measurement techniques applied during the test. Instantaneous PIV vector fields reveal that the flow separation is not stationary but rather highly dynamic. Mean flow statistics calculated from the PIV measurements highlight where reverse flow and Reynolds stresses are concentrated in the separated region and agree well with results from the embedded Laser Doppler Velocimeter system and Computational Fluid Dynamics. The comparisons and additional insight gained during this effort will help guide system improvements for follow-on tests.

Jenkins, Luther N.↗

Early hydration and setting of oil well cement

A broad experimental study has been performed to characterize the early hydration and setting of cement pastes prepared with Class H oil well cement at water-to-cement ratios (w/c) from 0.25 to 0.40, cured at temperatures from 10 to 60 {sup o}C, and mixed with chemical additives. Chemical shrinkage during hydration was measured by a newly developed system, degree of hydration was determined by thermogravimetric analysis, and setting time was tested by Vicat and ultrasonic velocity measurements. A Boundary Nucleation and Growth model provides a good fit to the chemical shrinkage data. Temperature increase and accelerator additions expedite the rate of cement hydration by causing more rapid nucleation of hydration products, leading to earlier setting; conversely, retarder and viscosity modifying agents delay cement nucleation, causing later setting times. Lower w/c paste needs less hydration product to form a percolating solid network (i.e., to reach the initial setting point). However, for the systems evaluated, at a given w/c, the degree of hydration at setting is a constant, regardless of the effects of ambient temperature or the presence of additives.

36 MATERIALS SCIENCE↗