Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Testing contamination source identification methods for water distribution networks

In the event of contamination in a water distribution network (WDN), source identification (SI) methods that analyze sensor data can be used to identify the source location(s). Knowledge of the source location and characteristics are important to inform contamination control and cleanup operations. Various SI strategies that have been developed by researchers differ in their underlying assumptions and solution techniques. The following manuscript presents a systematic procedure for testing and evaluating SI methods. The performance of these SI methods is affected by various factors including the size of WDN model, measurement error, modeling error, time and number of contaminant injections, and time and number of measurements. This paper includes test cases that vary these factors and evaluates three SI methods on the basis of accuracy and specificity. The tests are used to review and compare these different SI methods, highlighting their strengths in handling various identification scenarios. These SI methods and a testing framework that includes the test cases and analysis tools presented in this paper have been integrated into EPA’s Water Security Toolkit (WST), a suite of software tools to help researchers and others in the water industry evaluate and plan various response strategies in case of a contamination incident. Lastly, a set of recommendations are made for users to consider when working with different categories of SI methods.

54 ENVIRONMENTAL SCIENCES↗

Transportable absolute yields of underground nuclear explosions. Application to the North Korean nuclear tests

The method developed and presented here improves our nuclear explosion monitoring capability by providing a new independent and transportable method to determine the explosive yields of seismically recorded events associated with foreign weapons development. Here we report new independent absolute yield and depth of burial estimates of the North Korean nuclear tests which are commensurate with previously determined source parameters. The key advantage of this method over other methods which estimate absolute explosive yields is that this method does not require any a priori calibration, and can be immediately applied to any region of interest. This method uses the source information obtained from the spectral ratios of envelopes of measured seismic coda waves to invert for model-derived yield and depth of burial. The only requirements of this method are that the region of interest must contain several (> 3) seismic sources which have been well recorded (SNR > 2) by a set of shared stations. For regions with only a few events (~ 3) and/or extremely band-limited observations for which the depth of burial is unknown, an earthquake with a known magnitude may be required to obtain an accurate and robust yield estimate.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Evaluation of the Repeatability of the Delta Q Duct Leakage Testing TechniqueIncluding Investigation of Robust Analysis Techniques and Estimates of Weather Induced Uncertainty

The DeltaQ test is a method of estimating the air leakage from forced air duct systems. Developed primarily for residential and small commercial applications it uses the changes in blower door test results due to forced air system operation. Previous studies established the principles behind DeltaQ testing, but raised issues of precision of the test, particularly for leaky homes on windy days. Details of the measurement technique are available in an ASTM Standard (ASTM E1554-2007). In order to ease adoption of the test method, this study answers questions regarding the uncertainty due to changing weather during the test (particularly changes in wind speed) and the applicability to low leakage systems. The first question arises because the building envelope air flows and pressures used in the DeltaQ test are influenced by weather induced pressures. Variability in wind induced pressures rather than temperature difference induced pressures dominates this effect because the wind pressures change rapidly over the time period of a test. The second question needs to answered so that DeltaQ testing can be used in programs requiring or giving credit for tight ducts (e.g., California's Building Energy Code (CEC 2005)). DeltaQ modeling biases have been previously investigated in laboratory studies where there was no weather induced changes in envelope flows and pressures. Laboratory work by Andrews (2002) and Walker et al. (2004) found biases of about 0.5% of forced air system blower flow and individual test uncertainty of about 2% of forced air system blower flow. The laboratory tests were repeated by Walker and Dickerhoff (2006 and 2008) using a new ramping technique that continuously varied envelope pressures and air flows rather than taking data at pre-selected pressure stations (as used in ASTM E1554-2003 and other previous studies). The biases and individual test uncertainties for ramping were found to be very close (less than 0.5% of air handler flow) to those found in for the pressure station approach. Walker and Dickerhoff also included estimates of DeltaQ test repeatability based on the results of field tests where two houses were tested multiple times. The two houses were quite leaky (20-25 Air Changes per Hour at 50Pa (0.2 in. water) (ACH50)) and were located in the San Francisco Bay area. One house was tested on a calm day and the other on a very windy day. Results were also presented for two additional houses that were tested by other researchers in Minneapolis, MN and Madison, WI, that had very tight envelopes (1.8 and 2.5 ACH50). These tight houses had internal duct systems and were tested without operating the central blower--sometimes referred to as control tests. The standard deviations between the multiple tests for all four houses were found to be about 1% of the envelope air flow at 50 Pa (0.2 in. water) (Q50) that led to the suggestion of this as a rule of thumb for estimating DeltaQ uncertainty. Because DeltaQ is based on measuring envelope air flows it makes sense for uncertainty to scale with envelope leakage. However, these tests were on a limited data set and one of the objectives of the current study is to increase the number of tested houses. This study focuses on answering two questions: (1) What is the uncertainty associated with changes in weather (primarily wind) conditions during DeltaQ testing? (2) How can these uncertainties be reduced? The first question is addressing issues of repeatability. To study this five houses were tested as many times as possible over a day. Weather data was recorded on-site--including the local windspeed. The result from these five houses were combined with the two Bay Area homes from the previous studies. The variability of the tests (represented by the standard deviation) is the repeatability of the test method for that house under the prevailing weather conditions. Because the testing was performed over a day a wide range of wind speeds was achieved following typical diurnal variations of low wind in the early morning and greatest winds in the late afternoon/early evening. Typically about ten tests were performed in each house. To answer the second question, different data analysis techniques were investigated that looked at averaging techniques, elimination of outliers, limiting leak pressures, etc. in order to minimize the influence of changing wind conditions during the test. The objective was to find a reasonable compromise between test precision and robustness--because many of the changes to the analysis to make the test more robust limit its ability to examine wide ranges of pressures and leakage flows. A secondary goal of this study is to show that DeltaQ uncertainties are acceptable for testing low leakage systems. Therefore houses with low duct leakage were deliberately chosen to be tested.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel drop weight impact setup for testing reinforced concrete beams

A novel method of testing reinforced concrete beams under impact using a drop tower is described. The method consists of configuring the support conditions and instrumenting both the loading end of the hammer and support points in such a way that a proper dynamic analysis of the impact event can be performed and rational data can be derived.

42 ENGINEERING↗

Method and system for an on-chip AC self-test controller

A method and system for performing AC self-test on an integrated circuit that includes a system clock for use during normal operation are provided. The method includes applying a long data capture pulse to a first test register in response to the system clock, applying an at speed data launch pulse to the first test register in response to the system clock, inputting the data from the first register to a logic path in response to applying the at speed data launch pulse to the first test register, applying an at speed data capture pulse to a second test register in response to the system clock, inputting the logic path output to the second test register in response to applying the at speed data capture pulse to the second test register, and applying a long data launch pulse to the second test register in response to the system clock.

42 ENGINEERING↗

A Lizard-inspired Tube Inspector (LTI) Robot

This final report summarizes the research findings of the current project. This project is a collaboration between New Mexico State University (NMSU) as a lead (Recipient) and Arizona State University (ASU) as a Co-Recipient. Tubular structures are common components of boilers and heat exchangers in power plants. Over time, these components may suffer corrosion, cracks, and stress-corrosion cracks in either the body or the welded connections. A single tube leakage can cause an outage of several weeks. Regular inspection is a key safety factor when ensuring that power plants are maintained in reliable, operational condition. This inspection, however, is challenging, time-consuming, and in many cases impossible due to accessibility issues and safety concerns. Recent developments in robotic-based inspection can offer a great solution. Hard-to-reach places can be inspected without overhauling the unit, saving time and cost. Although several robots have been designed and implemented successfully for inspecting power plant components, in particular tubular structures, their mobility and flexibility are limited. Most of these robots use wheels for mobility which reduces their maneuverability of these robots. Moreover, they usually use magnets to attach to tubes which will not work on tubes with non-ferromagnetic materials. These robots usually carry measurement tools for a particular non-destructive testing (NDT) method such as ultrasound testing (UT) that requires a couplant to perform a point-by-point (scanning) inspection of the tubular structure. In this project, we developed a versatile lizard-inspired tube inspector (LTI) robot with embedded inspection sensing components for tube inspection which removes the need for point-by-point scanning of tube surface for crack and corrosion detection. Inspired by a “lizard”, the novelty of the current project is the integration of couplant-free ultrasound sensing and transmission, advanced data-driven defect detection and imaging, and friction-based mechanical mobility components in a single robot to eliminate a need for smooth surfaces and simple geometry for mobility and scanning. The LTI robot could replace the wheel-based approach with friction-based mobility to significantly increase the flexibility and maneuverability of the robot. The LTI robot can get into a power plant unit, such as a boiler, from a small area allowing it to access a component of interest for inspection (e.g., move on OD, curved and flat surfaces, non-ferromagnetic or ferromagnetic materials, and tubes with rough surfaces and complex geometries). Additionally, an advanced data-driven method using ultrasound data was pioneered to allow the robot to detect defects in the entire area between the robot’s multi-functional mobility system (grippers). Integrating a couplant-free ultrasound sensing in the robot’s grippers as well as using advanced data-driven methods allowed the LTI to detect defects in the entire cross-section of a tube using its grippers when stationary and when mobile.

20 FOSSIL-FUELED POWER PLANTS↗

Saline pulse test monitoring with the self‐potential method to nonintrusively determine the velocity of the pore water in leaking areas of earth dams and embankments

A method is proposed to localize preferential fluid flow pathways in porous media on the basis of time‐lapse self‐potential measurements associated with salt tracer injection upstream. This method is first tested using laboratory data. A network of nonpolarizing electrodes located is connected to a highly sensitive voltmeter used to record the resulting electrical field fluctuations occurring over time at the surface of the tank. The transport of the conductive salt plume through the permeable porous materials changes the localized streaming potential coupling coefficient associated with the advective drag of the excess charge of the pore water and is also responsible for a diffusion current associated with the salinity gradient. Monitoring of the electrical potential distribution at the ground surface can be used to localize the pulse of saline water over time and to determine its velocity. This method applies in real time and can be used to track highly localized flow pathways characterized by high permeability. Our sandbox experiment demonstrates the applicability of this new method under well‐controlled conditions with a coarse‐sand channel embedded between fine‐sand banks. A finite element model allows us to reproduce the time‐lapse electrical potential distribution over the channel, but some discrepancies were observed on the banks. Finally, we performed a numerical simulation for a synthetic case study inspired by a recently published field case study. A Markov chain Monte Carlo sampler is used to determine the permeability and the porosity of the preferential fluid flow pathway of this synthetic case study.

54 ENVIRONMENTAL SCIENCES↗

Smoothed dissipative particle dynamics with angular momentum conservation

Smoothed dissipative particle dynamics (SDPD) combines two popular mesoscopic techniques, the smoothed particle hydrodynamics and dissipative particle dynamics (DPD) methods, and can be considered as an improved dissipative particle dynamics approach. Despite several advantages of the SDPD method over the conventional DPD model, the original formulation of SDPD by Español and Revenga (2003) [9], lacks angular momentum conservation, leading to unphysical results for problems where the conservation of angular momentum is essential. To overcome this limitation, we extend the SDPD method by introducing a particle spin variable such that local and global angular momentum conservation is restored. The new SDPD formulation (SDPD+a) is directly derived from the Navier–Stokes equation for fluids with spin, while thermal fluctuations are incorporated similarly to the DPD method. We test the new SDPD method and demonstrate that it properly reproduces fluid transport coefficients. Also, SDPD with angular momentum conservation is validated using two problems: (i) the Taylor–Couette flow with two immiscible fluids and (ii) a tank-treading vesicle in shear flow with a viscosity contrast between inner and outer fluids. For both problems, the new SDPD method leads to simulation predictions in agreement with the corresponding analytical theories, while the original SDPD method fails to capture properly physical characteristics of the systems due to violation of angular momentum conservation. In conclusion, the extended SDPD method with angular momentum conservation provides a new approach to tackle fluid problems such as multiphase flows and vesicle/cell suspensions, where the conservation of angular momentum is essential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An improved method to increase the predictive accuracy of the ECR technique

The technique of electrical conductivity relaxation (ECR) is a widely utilized method for obtaining oxygen chemical surface exchange (k) and bulk diffusion (D) coefficients for mixed ionic electronic conductors. Although the technique is conceptually simple, its practical application does not frequently produce reliably accurate values of k and D, and many examples of poor agreement can be found in the published literature. In this present paper, methods for enhancing the accuracy of the ECR technique relative to data processing are described in detail. Physically accurate determination of the actual starting time (t{sub 0}) and improved methods for data fitting of ECR measurements are discussed. To test the methods described, generated relaxation data sets are analyzed by using non-linear-least-square (NLLS) methods. The results showed that fixing t{sub 0} based on an ideally stirred reactor model improves the fitted results compared to treating t{sub 0} as a fitted parameter. Additionally, evaluation of the global minimum in the fitted error is made by analyzing multiple samples of varying thickness, which improves parameter evaluation compared to analysis of a single relaxation data set. The improved accuracy of the computed values of k and D is described in comparison to conventional methods.

Bulk diffusion coefficient↗

A Ricin Forensic Profiling Approach Based on a Complex Set of Biomarkers

A forensic method for the retrospective determination of preparation methods used for illicit ricin toxin production was developed. The method was based on a complex set of biomarkers, including carbohydrates, fatty acids, seed storage proteins, in combination with data on ricin and Ricinus communis agglutinin. The analyses were performed on samples prepared from four castor bean plant ( Ricinus communis ) cultivars by four different sample preparation methods (PM1 – PM4) ranging from simple disintegration of the castor beans to multi-step preparation methods including different protein precipitation methods. Comprehensive analytical data was collected by use of a range of analytical methods and robust orthogonal partial least squares-discriminant analysis- models (OPLS-DA) were constructed based on the calibration set. By the use of a decision tree and two OPLS-DA models, the sample preparation methods of a test set of ricin preparations were determined. The model statistics of the two models were good and a 100% rate of correct predictions of the test set was achieved.

Fredriksson, Sten-Åke (ORCID:0000000237131990)↗

Regularized Orbital-Optimized Second-Order Møller–Plesset Perturbation Theory: A Reliable Fifth-Order-Scaling Electron Correlation Model with Orbital Energy Dependent Regularizers

We derive and assess two new classes of regularizers that cope with offending denominators in the single-reference second-order Møller-Plesset perturbation theory (MP2). In particular, we discuss the use of two types of orbital energy dependent regularizers, κ and σ, in conjunction with orbital-optimized MP2 (OOMP2). The resulting fifth-order-scaling methods, κ-OOMP2 and σ-OOMP2, have been examined for bond-breaking, thermochemistry, nonbonded interactions, and biradical problems. Both methods with strong enough regularization restore restricted to unrestricted instability (i.e., Coulson-Fischer points) that unregularized OOMP2 lacks when breaking bonds in H 2 , C 2 H 6 , C 2 H 4 , and C 2 H 2 . The training of the κ and σ regularization parameters was performed with the W4-11 set. We further developed scaled correlation energy variants, κ-S-OOMP2 and σ-S-OOMP2, by training on the TAE140 subset of the W4-11 set. Those new OOMP2 methods were tested on the RSE43 set and the TA13 set where unmodified OOMP2 itself performs very well. The modifications we made were found insignificant in these data sets. Furthermore, we tested the new OOMP2 methods on singlet biradicaloids using Yamaguchi's approximate spin-projection. Unlike the unregularized OOMP2, which fails to converge these systems due to the singularity, we show that regularized OOMP2 methods successfully capture strong biradicaloid characters. While further assessment on larger data sets is desirable, κ-OOMP2 with κ = 1.45 E h-1 appears to combine favorable recovery of Coulson-Fischer points with good numerical performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SEARCHING FOR NAPHTHALENE CATION ABSORPTION IN THE INTERSTELLAR MEDIUM

Interstellar naphthalene cations (C{sub 10}H{sup +}{sub 8}) have been proposed by a study to be the carriers of a small number of diffuse interstellar bands (DIBs). Using an archive of high signal-to-noise spectra obtained at the Apache Point Observatory, we used two methods to test the hypothesis. Both methods failed to detect significant absorption at lab wavelengths of interstellar spectra with laboratory spectra. We thereby conclude that C{sub 10}H{sup +}{sub 8} is not a DIB carrier in typical reddened sight lines.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient numerical method to calculate the three-tangle of mixed states

We demonstrate an efficient numerical method to calculate the three-tangle of general mixed states. We construct an ''energy function'' (target function) for the three-tangle of the mixed state under certain constraints. The energy function (target function) is then optimized via the replica exchange Monte Carlo method. We have extensively tested the method for the examples with known analytical results, showing remarkable agreement. The method can be applied to other optimization problems in quantum information theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-150: End to End Tests On the First Clinical EDGETM

Purpose: To quantify the sub millimeter overall accuracy of EDGETM, the dedicated linac based SRS/SABR treatment platform from Varian, using a novel End-to-End (E2E) test phantom. Methods: The new E2E test phantom developed by Varian consists of a cube with an outer dimension of 15x15x15 cm3. The phantom is equipped with an exchangable inner cube (7×7×7 cm3) to hold radiochromic films or a tungsten ball (diameter = 5 mm) for Winston-Lutz tests. 16 ceramic balls (diameter = 5 mm) are embedded in the outer cube. Three embedded Calypso transponders allow for Calypso based monitoring. The outer surface of the phantom is tracked using the Optical Surface Monitoring System (OSMS). The phantom is positioned using kV, MV and CBCT images. A simCT of the phantom was acquired and SRS/SABR plans were treated using the new phantom on the first clinical installed EDGETM. As a first step a series of EPID based Winston-Lutz tests have been performed. As a second step the calculated dose distribution applied to the phantom was verified with radiochromic films in orthogonal planes. The measured dose distribution is compared with the calculated (Eclipse) one based on the known isocenter on both dose distributions. The geometrical shift needed to match both dose distributions is the overall accuracy and is determined using dose profiles, isodose lines or gamma pass rates (3%, 1 mm). Results: Winston-Lutz tests using the central tungsten BB demonstrated a targeting accuracy of 0.44±0.18mm for jaw (2cm × 2cm) defined 0.39±0.19mm for MLC (2cm × 2cm) defined and 0.37±0.15mm for cone (12.5 mm) defined fields. A treated patient plan (spinal metastases lesion with integrated boost) showed a dosimetric dose localization accuracy of 0.6mm. Conclusion: Geometric and dosimetric E2E tests on EDGETM, show sub-millimeter E2E targeting and dose localisation accuracy.

60 APPLIED LIFE SCIENCES↗

Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR

Purpose: The quantitative accuracy of standardized uptake values (SUVs) and tracer kinetic uptake parameters in patient investigations strongly depends on accurate determination of regional activity concentrations in positron emission tomography (PET) data. This determination rests on the assumption that the given scanner calibration is valid in vivo. In a previous study, we introduced a method to test this assumption. This method allows to identify discrepancies in quantitative accuracy in vivo by comparison of activity concentrations of urine samples measured in a well-counter with activity concentrations extracted from PET images of the bladder. In the present study, we have applied this method to the Philips Ingenuity-TF PET/MR since at the present stage, absolute quantitative accuracy of combined PET/MR systems is still under investigation. Methods: Twenty one clinical whole-body F18-FDG scans were included in this study. The bladder region was imaged as the last bed position and urine samples were collected afterward. PET images were reconstructed including MR-based attenuation correction with and without truncation compensation and 3D regions-of-interest (ROIs) of the bladder were delineated by three observers. To exclude partial volume effects, ROIs were concentrically shrunk by 8–10 mm. Then, activity concentrations were determined in the PET images for the bladder and for the urine by measuring the samples in a calibrated well-counter. In addition, linearity measurements of SUV vs singles rate and measurements of the stability of the coincidence rate of “true” events of the PET/MR system were performed over a period of 4 months. Results: The measured in vivo activity concentrations were significantly lower in PET/MR than in the well-counter with a ratio of the former to the latter of 0.756 ± 0.060 (mean ± std. dev.), a range of 0.604–0.858, and a P value of 3.9 ⋅ 10{sup −14}. While the stability measurements of the coincidence rate of “true” events showed no relevant deviation over time, the linearity scans revealed a systematic error of 8%–11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 –0.941), P = 1.1 ⋅ 10{sup −10}. After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693–0.992), P = 3.9 ⋅ 10{sup −8}. Conclusions: Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

60 APPLIED LIFE SCIENCES↗

Measurement of steel plate perforation tests with digital image correlation.

The results of a series of punch-through tests performed on steel plates are presented. The geometry consisted of circular plates with welded boundary condition penetrated by a conical shaped punch with either a radiused or flat cylindrical end. After initial failure, the conical portion of the punch was driven through the plate to exercise tearing mechanics. Tests were performed quasi-statically with a hydraulic actuator and dynamically using a high-capacity drop table. Deformation and strain were measured with a stereo DIC system. The quasi-static tests utilized a conventional direct-view DIC technique while the dynamic tests required development of an indirect-view technique using a mirror. Experimental details used to conduct the test series will be presented along with test results. Methods of assessing test-to-test repeatability will be discussed. DIC results will also be synchronized and compared with transducer data (displacement and strain).

36 MATERIALS SCIENCE↗

First Experimental Test of the Ratio Method

The ratio is a new reaction observable suggested to extract accurately structure information on halo nuclei. It corresponds to the ratio of differential cross sections for scattering and breakup, which is predicted to remove the uncertainty related to the reaction dynamics. We present here the first experimental test of the method for the 11 Be + 12 C collision at E Lab = 20A MeV performed at Texas A&M University. Differential cross sections for scattering and inclusive one-neutron breakup have been measured with the new detector array BlueSTEAl. The ratio of cross sections is very smooth and independent of the projectile-target interaction, which demonstrates the validity of the ratio method. We extend our analysis to existing 11 Be + 208 Pb data, confirming that the method works well on any target.

11Be↗

Optimization of Distribution Feeder Topology: A Differential Programming Learning Approach

This paper presents a gradient based method for optimizing distribution feeder network topology under load un- certainty. We recast the optimal network reconfiguration problem as a learning problem where edge weights of a graph are learned to produce an optimized spanning tree for a distribution network. Using recent methods published on differentiable programming, we provide a data driven method for learning these weights. We test our method on 100 variations of an IEEE 15-bus test system. Our results show that our method outperforms more traditional mathematical programming-based approaches.

differentiable programming↗