High-pressure liquid-monopropellant strand combustion.

Examination of the influence of dissolved gases on the state of the liquid surface during high-pressure liquid-monopropellant combustion through the use of a strand burning experiment. Liquid surface temperatures were measured, using fine-wire thermocouples, during the strand combustion of ethyl nitrate, normal propyl nitrate, and propylene glycol dinitrate at pressures up to 81 atm. These measurements were compared with the predictions of a variable-property gas-phase analysis assuming an infinite activation energy for the decomposition reaction. The state of the liquid surface was estimated using a conventional low-pressure phase equilibrium model, as well as a high-pressure version that considered the presence of dissolved combustion-product gases in the liquid phase. The high-pressure model was found to give a superior prediction of measured liquid surface temperatures. Computed total pressures required for the surface to reach its critical mixing point during strand combustion were found to be in the range from 2.15 to 4.62 times the critical pressure of the pure propellant. Computed dissolved gas concentrations at the liquid surface were in the range from 35 to 50% near the critical combustion condition.

Faeth, G. M.↗

Effects of overlaps, stitches, and patches on multilayer insulation.

The effects of spacecraft installation-type discontinuities on aluminized Mylar multilayer insulation have been measured using an electrically heated cylindrical calorimeter. The experimental results have been reproducible within plus or minus 10% or better for identical blankets and less than plus or minus 5% for the same blanket. Good blanket performance can be obtained using short interleaving for joints, eliminating stitched seams, and using small patches, particularly over the hot side of stitches. The heat loss through stitching is excessive but highly localized. Analytical models matched to thermocouple test results are presented. The manner in which radiation and conduction participate in heat transfer adjacent to discontinuities is indicated. High lateral heat transfer is also established as an important phenomenon in the vicinity of a discontinuity.

Stimpson, L. D.↗

Development of a full-length external-fuel thermionic converter for in-pile testing.

Description of an external-fuel thermionic converter which utilizes a thoriated-tungsten fuel-emitter body. Performance in out-of-pile tests was comparable to that of an arc-cast tungsten emitter body, with 400-eW output power (about 5 W/sq cm) at 10.8% efficiency. Maximum fuel clad temperature averaged from 1650 to 1700 C during the 300-hour test. This converter has been processed for in-pile testing. The various processing steps, including the installation of six emitter thermocouples, encapsulation in the secondary container, and joining to the fission-gas collection system, are described in detail. In addition to the converter assembly, a doubly contained fission gas collection assembly with radiation-hardened differential pressure transducers was fabricated. The experiment support plate required for the in-pile test, containing electrically insulated instrumentation feedthroughs and coolant line feedthroughs to the vacuum test chamber, was also fabricated.

Schock, A.↗

A cooled-gas pyrometer for use in hypersonic engine testing

A cooled-gas pyrometer designed for application in a hypersonic research engine program was fabricated and tested. Design and operational considerations and calibration data are presented. The probe was tested in a rocket-engine exhaust stream operating at Mach 2 and 2300 K. Test temperature measurements agreed to within 2 percent with a radiation shielded thermocouple probe.

Glawe, G. E.↗

Pulsed electromagnetic acceleration

Direct measurements of the power deposited in the anode of a multimegawatt MPD accelerator using thermocouples attached to a thin shell anode reveal a dramatic decrease in the fractional anode power from 50% at 200 KW input power to less than 10% at 20 MW power. The corresponding local power flux peak at a value of 10,000 W/sq cm at the lip of the anode exhaust orifice, a distribution traced to a corresponding peak in the local current density at the anode. A comparison of voltage-current characteristics and spectral photographs of the MPD discharge using quartz, boron nitride and plexiglas insulators with various mass injection configurations led to the identification of different voltage modes and regions of ablation free operation. The technique of piezoelectric impact pressure measurement in the MPD exhaust flow was refined to account for the effects due to probe yaw angle.

Jahn, R. G.↗

Fabrication of capsule assemblies, phase 3

Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.

Keeton, A. R.↗

Irradiation of three T-111 clad uranium nitride fuel pins for 8070 hours at 990 C (1815 F)

The design and successful operation of three tantalum alloy (Ta-8W-2Hf) clad uranium mononitride (UN) fuel pins irradiated for 8070 hr at 990 C (1815 F) is described. Two pin diameters having measured burnups of 0.47 and 0.90 uranium atom percent were tested. No clad failures or swelling was detected; however, postirradiation clad samples tested failed with 1 percent strain. The fuel density decrease was 2 percent, and the fission gas release was less than 0.05 percent. Isotropic fuel swelling, which averaged about 0.5 percent, was less than fuel pin assembly clearances. Thus the clad was not strained. Thermocouples with a modified hot zone operated at average temperatures to 1100 C (2012 F) without failure. Factors that influence the ability to maintain uniform clad temperature as well as the results of the heat transfer calculations are discussed.

Slaby, J. G.↗

Complex permittivity measurements during high temperature recycling of space shuttle antenna window and dielectric heat shield materials

The research performed and the data obtained on candidate space shuttle antenna window and heat shield materials are presented. The measurement technique employs a free-space focused beam microwave bridge for obtaining RF transmission data, and a device which rotates a sample holder which is heated on one side by natural gas-air flames. The surface temperature of each sample is monitored by IR pyrometry; embedded and rear surface thermocouples are also used in obtaining temperature data. The surface of the sample undergoing test is subjected to approximately the same temperature/time profile that occurs at a proposed antenna position on the space shuttle as it re-enters. The samples are cycled through ten of these temperature profiles to determine the recycling effects. Very little change was noted in the materials due to the recycling.

Bassett, H. L.↗

Oscillation effects upon film boiling from a sphere.

Heat transfer rates from a silver-plated copper sphere, 0.75 in. in diameter, were studied by high speed photography during oscillations of the sphere in saturated liquid nitrogen and Freon-11. The oscillation frequencies ranged from zero to 13 Hz, and the amplitude-to-diameter ratio varied from zero to 2.67. The sphere was supported by a thin-walled stainless steel tube and carried a thermocouple attached near the lower stagnation point. A Fastax WF-3 16mm movie camera was used at about 2000 frames/sec. The differences in the vapor removal process at lower and higher oscillation frequencies are discussed.

Schmidt, W. E.↗

Hybrid TE panel test results.

Test results are presented for a nine couple (3 x 3 array) thermoelectric panel of hybrid thermocouples. In the hybrid couple, a hollow cylinder of p-type Si-Ge is used to encapsulate a segmented PbTe/Si-Ge n-leg. The hybrid couple is predicted to offer a 10 to 15% improvement in performance relative to all Si-Ge couples. The efficiency, output power, and internal resistance of the panel, as well as the resistances of the individual hybrid couples, are presented as a function of test time covering a period of more than 2600 hours. Initial test results indicated hybrid couple performance consistent with design predictions. However, the 10 to 15% improvement over all-Si-Ge couples demonstrated initially by the hybrid couple was offset by the high resistance that developed following a thermal cycle due to heater failure after 600 hours of testing.

Bifano, W. J.↗

Ultrasonic thermometry using pulse techniques.

Ultrasonic pulse techniques have been developed which, when applied to inert gases, provide temperature measurements up to 8000 K. The response time can be less than 1 msec. This is a significant feature in studying shock-heated or combusting gases. Using a momentary contact coupling technique, temperature has been measured inside steel from 300 to 1500 K. Thin-wire sensors have been used above 2000 K in nuclear and industrial applications where conditions preclude the use of thermocouples, resistance devices, or optical pyrometers. At 2500 K, temperature sensitivity of 0.1% is obtained in Re wire sensors 5 cm long by timing five round trips with an electronic instrument that resolves the time interval between selected echoes to 0.1 microsec. Sensors have been operated at rotational speeds over 2000 rpm and in noisy environments. Temperature profiling of up to ten regions using only a single guided path or beam has also been accomplished.

Lynnworth, L. C.↗

Catalytic considerations in temperature measurement.

Literature discussing catalytic activity in platinum group temperature sensors is surveyed. Methods for the determination and/or elimination of catalytic activity are reported. A particular application of the literature is discussed in which it is possible to infer that a shielded platinum total temperature probe does not experience significant catalytic activity in the wake of a supersonic hydrogen burner, while a bare iridium plus rhodium, iridium thermocouple does. It is concluded that catalytic data corrections are restricted and that it is preferable to coat the temperature sensor with a noncatalytic coating. Furthermore, the desirability of transparent coatings is discussed.

Ash, R. L.↗

Thermal protection system gap heating rates of the Rockwell International flat plate heat transfer model (OH2A/OH2B)

Heat transfer data for the Rockwell International Flat Plate Thermocouple Model are presented. The model simulated the Space Shuttle Vehicle Thermal Protection System. Data were recorded for locations in and around various size gaps for various gap orientation configurations. The test was conducted at Mach 5.1 for free-stream Reynolds number per foot values from 500,000 to 1,500,000.

Foster, T. F.↗

Pulsed electromagnetic gas accelleration

Direct measurement with thermocouples of the power deposited in the anode of a multi-megawatt magnetoplasmadynamic discharge has shown the fractional anode power to decrease from 50% at 200 kW to 10% at 20 MW. Using local measurements of current density, electric potential, and electron temperature, the traditional model for heat conduction to the anode is found to be inadequate. Other experiments in which the voltage-current characteristics and exhaust velocities of MPD arcs using Plexiglas and boron nitride chamber insulators and various mass injection configurations show that ablation can affect nominal accelerator operation in several distinct ways. The incorporation of a hollow cathode in a 7 kA plasma discharge has shown that a stable current attachment can be realized in the cavity without the aid of cathode heaters, keeper electrodes, or emissive coatings.

Jahn, R. G.↗

Steady state thermal radiometers

A radiometer is described operating in a vacuum under steady state conditions. The front element is an aluminum sheet painted on the outer side with black or other absorptive material of selected characteristics. A thermocouple is bonded to the inner side of the aluminum sheet. That is backed by highly insulative layers of glass fiber and crinkled, aluminized Mylar polyester. Those layers are backed with a sturdy, polyester sheet, and the entire lamination is laced together by nylon cords. The device is highly reliable in that it does not drift out of calibration, and is significantly inexpensive.

Loose, J. D.↗

Anode power in a quasi-steady MPD thruster

Local anode heat flux in a quasi-steady MPD thruster is measured by thermocouples attached to the inside surface of a shell anode. Over a range of arc currents J from 5.5 to 44 kiloamperes and argon propellant mass flows m from 1 to 48 g/sec, with the ratio J2/m held constant, the fraction of arc power deposited in the anode is found to decrease with increasing arc power. Specifically, this anode power fraction decreases from 50% at 200 kW arc power, to 10% at 20 MW. In an effort to account for this functional behavior, the current density, plasma potential, and electron temperature in the plasma adjacent to the anode are measured with probes, and the results are used in a theoretical anode heat flux model. The model asserts that energy exchange between electrons and heavy particles in the plasma near the anode occur over distances greater than the anode sheath thickness.

Saber, A. J.↗

Studies of heat source driven natural convection

Natural convection energy transport in a horizontal layer of internally heated fluid with a zero heat flux lower boundary, and an isothermal upper boundary, has been studied. Quantitative information on the time-mean temperature distribution and the fluctuating component of temperature about the mean temperature in steady turbulent convection are obtained from a small thermocouple inserted into the layer through the upper bounding plate. Data are also presented on the development of temperature at several vertical positions when the layer is subject to both a sudden increase and to a sudden decrease in power input. For changes of power input from zero to a value corresponding to a Rayleigh number much greater than the critical linear stability theory value, a slight hysteresis in temperature profiles near the upper boundary is observed between the heat-up and cool-down modes.

Kulacki, F. A.↗

Anode power deposition in quasi-steady MPD arcs

The power deposited in the anode of a quasi-steady MPD accelerator has been measured directly by thermocouples attached to the inside surface of a shell anode which provide a local measurement of anode heat flux. The results over a range of arc currents from 5.5 to 44 kiloamperes and argon mass flows from 1 g/sec to 48 g/sec show that the fraction of the total input power deposited in the anode decreases drastically from 50% at an arc power of 200 kW to 10% at 20 MW, and that anode power is not uniformly deposited in the anode. A theoretical model of the anode heat transfer, including effects of anode work function, electron thermal energy, and anode sheath, can be brought into reasonable agreement with the measurements, provided the effective range of the conduction electrons from within the discharge plasma to the anode surface is properly acknowledged.

Saber, A. J.↗