Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Assessing potential induced radioactivity in materials processed with X-ray energy above 5 MeV: Assessment protocols and practical experience

In accordance with ISO11137-1 section 5.1.2, ‘the potential for induced radioactivity in product shall be assessed’. This article describes how compliance to this requirement may be achieved using qualified test methods. Materials of consideration are conceptually discussed. Results of testing conducted on products processed with a 7.5 MeV X-ray irradiation process are provided. As X-ray becomes more widely used in healthcare sterilization, having standard assessment protocols for activation coupled with a shared database of material test results will benefit all healthcare product manufacturers seeking to avail of this innovative technology.

Kroc, Thomas K.↗

Determination of acoustic nonlinearity parameters using thermal modulation of ultrasonic waves

This study presents a test method and its theoretical framework to determine the acoustic nonlinearity parameters (α, β, δ) of material using thermal modulation of ultrasonic waves. Temperature change-induced thermal strain excites the nonlinear response of the material and modulates the ultrasonic wave propagating in it. Experimental results showed a strong correlation between the relative wave velocity change and the temperature change. With a quadratic polynomial model, the acoustic nonlinearity parameters were obtained from the polynomial coefficients by curve fitting the experimental data. Their effects on thermal-induced velocity change were discussed. The parameters α, β, and δ govern the hysteretic gap, average slope, and curvature of the correlation curve, respectively. The proposed theory was validated on aluminum, steel, intact and damaged concrete samples. The obtained nonlinear parameters show reasonable agreement with values reported in the literature. Compared to other nonlinear acoustic methods using vibration or acoustic excitation, the thermal modulation method generates more uniform, slow changing, and larger strain field in the test sample. Employing the thermal effect as the driving force for nonlinearity instead of an undesired influencing factor, this method can measure the absolute values of α, β, and δ with good accuracy using a simple ultrasonic test setup.

Physics↗

Conducting High Cycle Fatigue Strength Step Tests on Gamma TiAl

High cycle fatigue strength testing of gamma TiAl by the step test method is investigated. A design of experiments was implemented to determine if the coaxing effect occurred during testing. Since coaxing was not observed, step testing was deemed a suitable method to define the fatigue strength at 106 cycles.

Lerch, Brad↗

Electrostatic testing of thin plastic materials

Ten thin plastic materials (Velostat, RCAS 1200, Llumalloy, Herculite 80, RCAS 2400, Wrightlon 7000, PVC, Aclar 22A, Mylar, and Polyethylene) were tested for electrostatic properties by four different devices: (1) The static decay meter, (2) the manual triboelectric testing device, (3) the robotic triboelectric testing device, and (4) the resistivity measurement adapter device. The static decay meter measured the electrostatic decay rates in accordance with the Federal Test Method Standard 101B, Method 4046. The manual and the robotic triboelectric devices measured the triboelectric generated peak voltages and the five-second decay voltages in accordance with the criteria for acceptance standards at Kennedy Space Center. The resistivity measurement adapter measured the surface resistivity of each material. An analysis was made to correlate the data among the four testing devices. For the material tested the pass/fail results were compared for the 4046 method and the triboelectric testing devices. For the limited number of materials tested, the relationship between decay rate and surface resistivity was investigated as well as the relationship between triboelectric peak voltage and surface resistivity.

Skinner, S. Ballou↗

Manipulator technology for the space shuttle

A shuttle-attached manipulator is currently proposed as the payload-handling device for the space shuttle. Basic requirements for the manipulator involve length, force, compliance, and control. Approaches for studying control methods are presented and simulation methods are discussed. Basic details about the two earthbased manipulators selected for simulation experiments are related to the test methods. Preliminary data from one test are shown as an example of the direction of the testing. A computer-generated simulation is explained, and the relationship of the three simulations to the design problems is discussed.

Burroughs, E. G.↗

Structural qualification of large spacecraft

Over the past twenty-five (25) years of the space program, the major challenge in the structural qualification of the primary structure has shifted from conducting a test that simulated the environment to accurately predicting the structural member loads in flight. Once the flight loads are avaliable, a number of different test methods are used to qualify the structure by subjecting it to the proper loads. The qualification challenge for future large spacecraft will be to adequately predict its dynamic characteristic in space to assure that it can be controlled to meet the mission objectives. A new test concept that may allow acquisition of modal data by ground tests for verification of mathematical models of large flexible space structures which can't be ground tested by conventional methods is discussed.

Wada, Ben K.↗

A Survey of Methods for Measuring Thermally Induced Distortions of Test Articles Undergoing Solar Thermal Vacuum Test

Various methods of measuring the small thermally induced distortions experienced either by various points on the space vehicles or by deviations of surfaces from a known shape during solar thermal vacuum tests are examined. State-of-the-art application of both photographic and real time observation are discussed. The relative merits of each of the methods are compared and evaluated in their applications to different types of test articles and situations. Magnitudes of thermally induced distortions which may be expected to be routinely measurable by the various methods are presented and compared.

Rempt, R. D.↗

The Effect of Systematic Error in Forced Oscillation Testing

One of the fundamental problems in flight dynamics is the formulation of aerodynamic forces and moments acting on an aircraft in arbitrary motion. Classically, conventional stability derivatives are used for the representation of aerodynamic loads in the aircraft equations of motion. However, for modern aircraft with highly nonlinear and unsteady aerodynamic characteristics undergoing maneuvers at high angle of attack and/or angular rates the conventional stability derivative model is no longer valid. Attempts to formulate aerodynamic model equations with unsteady terms are based on several different wind tunnel techniques: for example, captive, wind tunnel single degree-of-freedom, and wind tunnel free-flying techniques. One of the most common techniques is forced oscillation testing. However, the forced oscillation testing method does not address the systematic and systematic correlation errors from the test apparatus that cause inconsistencies in the measured oscillatory stability derivatives. The primary objective of this study is to identify the possible sources and magnitude of systematic error in representative dynamic test apparatuses. Sensitivities of the longitudinal stability derivatives to systematic errors are computed, using a high fidelity simulation of a forced oscillation test rig, and assessed using both Design of Experiments and Monte Carlo methods.

Williams, Brianne Y.↗

The Precision of Product Consistency Tests with Reference Glasses ARM-1 and SRM 623

An interlaboratory study (ILS) was conducted in 2014 to measure the precision with which the ASTM-International product consistency test method A (PCT-A) can be performed using properly prepared samples of reference glass ARM-1 or SRM 623 and test parameter values near the centers of ranges specified in procedure ASTM C1285. The ILS did not evaluate the full range of test parameter values allowed in the PCT-A method and the results do not represent the precision that should be expected if extreme values of the ranges are used. However, the precision measured in the ILS quantified the precision of tests conducted with mean parameters that were used to estimate the effects of individual parameters. Follow-on tests were conducted to assess the effects of several individual test parameter values on the test response and uncertainties in the derived glass dissolution rates. The effects of particle size distributions in glass samples prepared by wet- and dry-sieving methods, methods to remove fines, and the limiting parameter values for the water-to-glass (w/g) mass ratio and test duration allowed in PCT-A were measured. Test responses for all variations except test duration exceeded the precision measured in the ILS for conducting triplicate PCT-A tests within a single laboratory. The accuracy of glass dissolution rates derived from PCT results benefits from using a tighter control of these test variables than required in ASTM C1285. Comparison with previous analyses of the method shows how use of the relative standard deviation to represent the test precision can be misleading, and that the mean response and standard deviation should both be considered.

36 MATERIALS SCIENCE↗

High-Throughput Statistical Interrogation of Mechanical Properties with Build Plate Location and Powder Reuse in AlSi10Mg

Abstract Additive manufacturing (AM) allows agile, rapid manufacturing of geometrically complex components that would otherwise be impossible through traditional manufacturing methods. With this maturing manufacturing technology comes the need to adopt testing methods that are commensurate with the speed of additive manufacturing and take advantage of its geometric flexibility. High-throughput tensile testing (HTT) is a technique that allows a large number of tensile bars to be tested in a short amount of time. In the present study, HTT is used to evaluate AM AlSi10Mg produced using powder bed fusion with a Renishaw AM250 machine. Three parameters were varied in this study: (1) powder reuse history, (2) location on the build plate, and (3) size of the tensile specimen. For all parameter combinations, at least 22 specimens were tested; in several cases, over 40 were tested. This large dataset, consisting of over 500 tensile tests, permits Weibull statistical analysis and provides sufficient fidelity to isolate subtle trends that would have likely been missed in smaller, traditional datasets. The observed trends are rationalized in terms of the role of porosity and surface crust on mechanical response.

Carroll, Jay D. (ORCID:0000000258184709)↗

Tension fracture of laminates for transport fuselage. Part 1: Material screening

Transport fuselage structures are designed to contain pressure following a large penetrating damage event. Applications of composites to fuselage structures require a database and supporting analysis on tension damage tolerance. Tests with 430 fracture specimens were used to accomplish the following: (1) identify critical material and laminate variables affecting notch sensitivity; (2) evaluate composite failure criteria; and (3) recommend a screening test method. Variables studied included fiber type, matrix toughness, lamination manufacturing process, and intraply hybridization. The laminates found to have the lowest notch sensitivity were manufactured using automated tow placement. This suggests a possible relationship between the stress distribution and repeatable levels of material inhomogeneity that are larger than found in traditional tape laminates. Laminates with the highest notch sensitivity consisted of toughened matrix materials that were resistant to a splitting phenomena that reduces stress concentrations in major load bearing plies. Parameters for conventional fracture criteria were found to increase with crack length for the smallest notch sizes studied. Most material and laminate combinations followed less than a square root singularity for the largest crack sizes studied. Specimen geometry, notch type, and notch size were evaluated in developing a screening test procedure. Traitional methods of correcting for specimen finite width were found to be lacking. Results indicate that a range of notch sizes must be tested to determine notch sensitivity. Data for a single small notch size (0.25 in. diameter) was found to give no indication of the sensitivity of a particular material and laminate layup to larger notch sizes.

Walker, T. H.↗

Two–Photon Polymerized Shape Memory Microfibers: A New Mechanical Characterization Method in Liquid

Two-photon polymerization (TPP) is widely used to create 3D micro- and nanoscale scaffolds for biological and mechanobiological studies, which often require the mechanical characterization of the TPP fabricated structures. To satisfy physiological requirements, most of the mechanical characterizations need to be conducted in liquid. However, previous characterizations of TPP fabricated structures are all conducted in air due to the limitation of conventional micro- and nanoscale mechanical testing methods. In this study, a new experimental method is reported for testing the mechanical properties of TPP-printed microfibers in liquid. The experiments show that the mechanical behaviors of the microfibers tested in liquid are significantly different from those tested in air. By controlling the TPP writing parameters, the mechanical properties of the microfibers can be tailored over a wide range to meet a variety of mechanobiology applications. In addition, it is found that, in water, the plasticly deformed microfibers can return to their predeformed shape after tensile strain is released. The shape recovery time is dependent on the size of microfibers. The experimental method represents a significant advancement in mechanical testing of TPP fabricated structures and may help release the full potential of TPP fabricated 3D tissue scaffolds for mechanobiological studies.

36 MATERIALS SCIENCE↗

Quality assurance and independent dosimetry for an intraoperative x-ray device

Purpose: Quality assurance is an essential component of accurate and safe radiotherapy delivery, and should include measurements which are independent of manufacturer-provided calibration. However, the physical and dosimetric properties of the INTRABEAM compact mobile 50 kV x-ray source are different from conventional kilovoltage therapy units and few reports describe methods for independent checks, frequencies, or tolerances for quality assurance tests. Methods: Based on the available evidence and local experience, methods are described for determination of the key dosimetric parameters: beam quality, output, isotropy, and depth doses. Internal system checks are also described, along with measurements of long-term stability. Results: A small volume parallel plate ionization chamber in a liquid water tank is the gold standard for measurements with this unit, but solid water-equivalent materials, thermoluminescent dosimeters and radiochromic film can all be used as practical alternatives with an accuracy of 5%-10%. The main cause of measurement uncertainty is positioning of the detector in the steep dose gradient, but energy dependence should also be considered. Conclusions: A quality assurance schedule with suggested tolerances is proposed, which includes both internal tests, before each treatment and on a monthly basis, and independent tests every year or after servicing or recalibration.

60 APPLIED LIFE SCIENCES↗

Design and Evaluation of a Ring Tension Test Grip for Remote Mechanical Testing of Irradiated Tubular Specimens

Here, the ring tension test (RTT) is a mechanical testing method for determining bulk mechanical behavior in the circumferential or hoop direction for tubular materials. The test is especially useful for testing materials with anisotropic mechanical properties, such as zirconium alloys, which are commonly used as nuclear fuel cladding. Anisotropy requires direction-specific testing to determine the hoop strength. Historically, several RTT methods and grips have been used, each method has its strengths and weaknesses, and, in all cases, the measured strength is subject to uncertainty due to variations of the testing geometry and experimental tolerances. Recent analysis has shown that grips with a hemicylindrical mandrel configuration are recommended as the most robust configuration. The two strictest aspects to be controlled are the ability to determine gage region orientation and closely matching the size of the mandrels to the test specimen. This last requirement is particularly challenging when the dimensions of the specimen vary because of environmental effects such as dimensional changes due to irradiation. This paper presents a new RTT grip designed to incorporate this mandrel shape, hold the gage at the desired orientation, be suitable for remote operation in a hot-cell environment, and be adaptable for different sizes or variations in the specimen size. The general description and the unique design features of the test specimen and grips are given in detail. The performance of the grips in mechanical testing, including in a remote hot-cell environment, is also provided.

42 ENGINEERING↗

Practical Insights on Applying Simulation-Based Control Methods in Experimental Studies

Advanced nuclear reactors are crucial to the future of energy both in the United States and around the globe. In contrast to the current operating fleet, they are characterized as being deployable in remote locations and able to operate in semi-autonomous or autonomous fashion. This leap forward necessitates a new reactor control paradigm. Because advanced nuclear reactors are still under development in the United States, the creation of new control methods to achieve autonomous operations has been based on systems modeling and simulation. However, an important factor in successfully deploying these new control methods is the ability to seamlessly transition from simulation environments to real-world settings. Control methods tested in both simulation and experimental settings need to be investigated in the context of advanced reactor applications. This work developed a series of simple controllers for Idaho National Laboratory (INL)’s Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor operating in load-following scenarios. These controllers were tested in both simulation and experimental settings, and a comparative performance analysis was performed. The simulation tests leveraged the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software developed in a previous stage of the current effort, along with the MARVEL Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The experimental tests leveraged the COMMAND software, MARVEL models, and the U.S. Department of Energy Microreactor Program’s Microreactor Automated Control System (MACS). MACS was developed to serve as a control method testbed. It was customized to mirror the MARVEL microreactor, and COMMAND enabled MACS to emulate the physics of MARVEL. The load-following controller was developed using the simulation platform, with efforts to emulate real systems by introducing actuator saturation and noise. These factors were incrementally accounted for in the controller design. After finalizing the controller design, it was implemented with the experimental setup. The experimental conditions tested included an initial test under conditions similar to the final simulation test, and two additional scenarios. The first scenario introduced additional actuator saturation to account for equipment aging over time, which was unknown to the controller. The second scenario introduced sensor delay, a phenomenon anticipated with the use of remote operations or wireless communication in advanced reactors. These tests revealed several notable differences. While the controller performed well in simulation, it exhibited several limitations when transitioning to hardware. The main challenges involved maintaining the steady-state target power, as evidenced by larger error values between the true reactor power and setpoint power, as well as persistent oscillations in controlled reactor power. These issues could lead to unacceptable transient conditions in real reactor testing. Introducing actuator aging and stochastic delays in the experimental setup significantly impacted controller performance, resulting in increased overshoot and undershoot, and exacerbated error and oscillations previously mentioned. These findings underscore the importance of experimental testbeds for testing and validating control methods, as controllers developed using only theory and/or simulation may perform unexpectedly when applied to actual hardware. This research emphasizes the need for an experimental testbed for achieving such validation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗