Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.3)

This document specifies an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is responsible for coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, and teams. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF procedures. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.5)

This document specifies an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is primarily responsible for implementing coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, teams and collective subroutines. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF subroutines. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Design Document (Rev. 0.2)

This design document proposes an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is responsible for coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, and teams. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF procedures. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.6)

This document specifies an interface to support the multi-image parallelism features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a solution in which a runtime library is primarily responsible for implementing coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, teams and collective subroutines. The Fortran compiler is responsible for transforming the invocation of Fortran-level multi-image parallelism features into procedure calls to the necessary PRIF subroutines. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.4)

This document specifies an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is responsible for coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, and teams. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF procedures. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

The transmission ramifications of social and environmental siting considerations on wind energy deployment

Increasing the capacity of wind power is critical to achieving climate goals, however its continued deployment faces environmental and social siting challenges. For example, the United States government is increasingly emphasizing the importance of a just energy transition by considering the social impacts of energy and environmental justice (EEJ). In this study, we investigate the impact of considering available EEJ metrics and environmental impacts into siting wind power and transmission by applying SimWIND PRO . SimWIND PRO is an infrastructure optimization tool that can site wind energy technologies and transmission by concurrently considering wind resource potential, transmission costs, EEJ, and environmental impacts. We demonstrate the impacts of considering EEJ and environmental factors in the context of Midcontinent Independent System Operator’s (MISO) western region, which includes some of the best wind energy potential in the United States. We show that prioritizing EEJ and environmental considerations in wind deployment can result in exponentially more transmission deployment for the same amount of wind power delivered, and results in selecting different wind farm sites. Our results also show that, depending on how it is considered, it is possible that constraining sites based on EEJ and environmental factors can reduce the available capacity of wind energy enough that energy transition capacity targets cannot be met.

17 WIND ENERGY↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Infrared-Fused Vision-Based Thermoregulation Performance Estimation for Personal Thermal Comfort-Driven HVAC System Controls

Thermal comfort is one of the primary factors influencing occupant health, well-being, and productivity in buildings. Existing thermal comfort systems require occupants to frequently communicate their comfort vote via a survey which is impractical as a long-term solution. Here, we present a novel thermal infrared-fused computer vision sensing method to capture thermoregulation performance in a non-intrusive and non-invasive manner. In this method, we align thermal and visible images, detect facial segments (i.e., nose, eyes, face boundary), and accordingly read the temperatures from the appropriate coordinates in the thermal image. We focus on the human face since it is often clearly visible to cameras and is not merged into a hot background (unlike hands). We use a regularized Gaussian Mixture model to track the thermoregulation changes over time and apply a heuristic algorithm to extract hot and cold indices. We present a personalized and a generalized comfort modeling method, selected based on the availability of the occupant historical indices measurements in a neutral environment, and use the time-series of the hot and cold indices to define corrections to HVAC system operations in the form of setpoint constraints. To evaluate the efficacy of our proposed approach in responding to thermal stimuli, we designed a series of controlled experiments to simulate exposure to cold and hot environments. While applying personalized modeling showed an acceptable average accuracy of 91.3%, the generalized model’s average accuracy was only 65.2%. This shows the importance of having access to physiological records in modeling and assessing comfort. We also found that individual differences should be considered in selecting the cooling and heating rates when some knowledge of the occupant’s overall thermal preference is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Underground Imaging by Sub-Terahertz Radiation

Sub-terahertz ground-penetrating radar systems offer an alternative to radio wave-based systems in the airborne imaging of buried objects. Laboratory prototype systems operating in W-band (75–110 GHz) and F-band (90–140 GHz) are presented, detecting the distance between target and source and imaging metal objects buried in mixed soil. The experimental results show that imaging in the 100–150 GHz frequency range is feasible for underground applications but significantly restricted by the attenuation characteristics of the medium covering the targets. A higher power source and more sensitive receiving components are essential to increase the penetration capability and expand the application settings of this approach.

42 ENGINEERING↗

Air Conditioning Systems Fault Detection and Diagnosis-Based Sensing and Data-Driven Approaches

The air conditioning (AC) system is the primary building end-use contributor to the peak demand for energy. The energy consumed by this system has grown as fast as it has in the last few decades, not only in the residential section but also in the industry and transport sectors. Therefore, to combat energy crises, urgent actions on energy efficiency should be taken to support energy security. Consequently, the faults in AC system components increase energy consumption due to the degradation of the system’s performance and the losses in the energy conversion procedure. In this work, AC system fault detection and diagnosis (FDD) methods are investigated to propose analytic tools to identify faults and provide solutions to those problems. The analysis of existing work shows that data-driven approaches are more accurate for both soft and hard fault detection and diagnosis in AC systems. Therefore, the proposed methods are not accurate for simultaneous fault detection, while in some works, authors tested the method with several faults separately without investigating scenarios that combine more than one fault. Moreover, this study shows that integrating data-driven approaches requires deploying an optimal sensing and measurement architecture that can detect a maximum number of faults with minimally deployed sensors. The new sensing, information, and communication technologies are discussed for their integration in AC system monitoring in order to optimize system operation and detect faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stress-Controlled Creep–Fatigue of an Advanced Austenitic Stainless Steel at Elevated Temperatures

Creep–fatigue interaction occurs in many structural components of high-temperature systems operating under cyclic and steady-state service conditions, such as in nuclear power plants, aerospace, naval, and other industrial applications. Thus, understanding micromechanisms governing high-temperature creep–fatigue behavior is essential for safety and design considerations. In this work, stress-controlled creep–fatigue tests of advanced austenitic stainless steel (Alloy 709) were performed at a 400 MPa stress range and 750 °C with tensile hold times of 0, 60, 600, 1800, and 3600 s, followed by microstructural examinations. The creep–fatigue lifetime of the Alloy 709 was found to decrease with increasing hold time until reaching a saturation level where the number of cycles to failure did not exhibit a significant decrease. Softening behavior was observed at the beginning of the test, possibly due to the recovery of entangled dislocations and de-twining. In addition, hysteresis loops showed ratcheting behavior, although the mean stress was zero during creep–fatigue cycling, which was attributed to activity of partial dislocations. Microstructural examination of the fracture surfaces showed that fatigue failure dominated at small hold times where the cracks initiated at the surface of the sample. Larger creep cracks were found for longer hold times with a lower probability of dimpled cavities, indicating the dominance of creep deformation. The results were compared with other commonly used stainless steels, and plausible reasons for the observed responses were described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fiber Optic Temperature Sensor System Using Air-Filled Fabry–Pérot Cavity with Variable Pressure

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

47 OTHER INSTRUMENTATION↗

A Robust Segmented Mixed Effect Regression Model for Baseline Electricity Consumption Forecasting

Renewable energy production has been surging around the world in recent years. To mitigate the increasing uncertainty and intermittency of the renewable generation, proactive demand response algorithms and programs are proposed and developed to further improve the utilization of load flexibility and increase the efficiency of power system operation. One of the biggest challenges to efficient control and operation of demand response resources is how to forecast the baseline electricity consumption and estimate the load impact from demand response resources accurately. In this paper, we propose a mixed effect segmented regression model and a new robust estimate for forecasting the baseline electricity consumption in Southern California, USA, by combining the ideas of random effect regression model, segmented regression model, and the least trimmed squares estimate. Since the log-likelihood of the considered model is not differentiable at breakpoints, we propose a new backfitting algorithm to estimate the unknown parameters. The estimation performance of the new estimation procedure has been demonstrated with both simulation studies and the real data application for the electric load baseline forecasting in Southern California.

42 ENGINEERING↗

The De-Icing Comparison Experiment (D-ICE): a study of broadband radiometric measurements under icing conditions in the Arctic

Abstract. Surface-based measurements of broadband shortwave (solar) and longwave (infrared) radiative fluxes using thermopile radiometers are made regularly around the globe for scientific and operational environmental monitoring. The occurrence of ice on sensor windows in cold environments – whether snow, rime, or frost – is a common problem that is difficult to prevent as well as difficult to correct in post-processing. The Baseline Surface Radiation Network (BSRN) community recognizes radiometer icing as a major outstanding measurement uncertainty. Towards constraining this uncertainty, the De-Icing Comparison Experiment (D-ICE) was carried out at the NOAA Atmospheric Baseline Observatory in Utqiaġvik (formerly Barrow), Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate existing ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational systems that are part of NOAA's Barrow BSRN station and the US Department of Energy Atmospheric Radiation Measurement (ARM) program North Slope of Alaska and Oliktok Point observatories. To detect icing, radiometers were monitored continuously using cameras, with a total of more than 1 million images of radiometer domes archived. Ventilator and ventilator–heater performance overall was skillful with the average of the systems mitigating ice formation 77 % (many >90 %) of the time during which icing conditions were present. Ventilators without heating elements were also effective and capable of providing heat through roughly equal contributions of waste energy from the ventilator fan and adiabatic heating downstream of the fan. This provided ∼0.6 ∘C of warming, enough to subsaturate the air up to a relative humidity (with respect to ice) of ∼105 %. Because the mitigation technologies performed well, a near complete record of verified ice-free radiometric fluxes was assembled for the duration of the campaign. This well-characterized data set is suitable for model evaluation, in particular for the Year of Polar Prediction (YOPP) first Special Observing Period (SOP1). We used the data set to calculate short- and long-term biases in iced sensors, finding that biases can be up to +60 W m−2 (longwave) and −211 to +188 W m−2 (shortwave). However, because of the frequency of icing, mitigation of ice by ventilators, cloud conditions, and the timing of icing relative to available sunlight, the biases in the monthly means were generally less than the aggregate uncertainty attributed to other conventional sources in both the shortwave and longwave.

54 ENVIRONMENTAL SCIENCES↗

Data collected using small uncrewed aircraft systems during the TRacking Aerosol Convection interactions ExpeRiment (TRACER)

Abstract. The main goal of the TRacking Aerosol Convection interactions ExpeRiment (TRACER) project was to further understand the role that regional circulations and aerosol loading play in the convective cloud life cycle across the greater Houston, Texas, area. To accomplish this goal, the United States Department of Energy and research partners collaborated to deploy atmospheric observing systems across the region. Cloud and precipitation radars, radiosondes, and air quality sensors captured atmospheric and cloud characteristics. A dense lower-atmospheric dataset was developed using ground-based remote sensors, a tethersonde, and uncrewed aerial systems (UASs). TRACER-UAS is a subproject that deployed two UAS platforms to gather high-resolution observations in the lower atmosphere between 1 June and 30 September 2022. The University of Oklahoma CopterSonde and the University of Colorado Boulder RAAVEN (Robust Autonomous Aerial Vehicle – Endurant Nimble) were flown at two coastal locations between the Gulf of Mexico and Houston. The University of Colorado Boulder RAAVEN gathered measurements of atmospheric thermodynamic state, winds and turbulence, and aerosol size distribution. Meanwhile, the University of Oklahoma CopterSonde system operated on a regular basis to resolve the vertical structure of the thermodynamic and kinematic state. Together, a complementary dataset of over 200 flight hours across 61 d was generated, and data from each platform proved to be in strong agreement. In this paper, the platforms and respective data collection and processing are described. The dataset described herein provides information on boundary layer evolution, the sea breeze circulation, conditions prior to and nearby deep convection, and the vertical structure and evolution of aerosols. The quality-controlled TRACER-UAS observations from the CopterSonde and RAAVEN can be found at https://doi.org/10.5439/1969004 (Lappin, 2023) and https://doi.org/10.5439/1985470 (de Boer, 2023), respectively.

54 ENVIRONMENTAL SCIENCES↗

Long-term measurements of ice nucleating particles at Atmospheric Radiation Measurement (ARM) sites worldwide

Ice nucleating particles (INPs) play a critical role in cloud microphysics and precipitation formation, yet long-term, spatially extensive observational datasets remain limited. Here, we present one of the most comprehensive publicly available datasets of immersion-mode INP concentrations using a single analytical method, generated through the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) user facility. INP filter samples have been collected across a broad range of environments – including agricultural plains, Arctic coastlines, high-elevation mountain sites, marine regions, and urban areas – via fixed observatories, mobile facility deployments, and vertically-resolved tethered balloon system operations. We describe the standardized processing and quality assurance pipeline, from filter collection and processing using the Ice Nucleation Spectrometer to final data products archived on the ARM Data Discovery portal. The dataset includes both total INP concentrations and selectively treated samples, allowing for classification of biological, organic, and inorganic INP types. It features a continuous 5-year record of INP measurements from a central U.S. site, with data collection still ongoing. Seasonal and site-specific differences in INP concentrations are illustrated through intercomparisons at −10 and −20 °C, revealing distinct regional sources and atmospheric drivers. We also outline mechanisms for researchers to access existing data, request additional sample analyses, and propose future field campaigns involving ARM INP measurements. This dataset supports a wide range of scientific applications, from observational and mechanistic studies to model development, and provides critical constraints on aerosol-cloud interactions across diverse atmospheric regimes (Creamean et al., 2024, 2020b; https://doi.org/10.5439/1770816).

Creamean, Jessie M. [Colorado State Univ., Fort Co↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗

Powered by dGen Webinar [Slides]

NLR's Powered By Webinar Series featuring NLR's dGen Modeling Tool. The Distributed Generation Market Demand (dGenTM) model simulates customer adoption of distributed energy resources for residential, commercial, and industrial entities in the United States or other countries through 2050. The model enables analysis at multiple geographic levels (national, state, and utility, or below) and offers sophistication in representation of decision-making regarding economic and behavioral considerations. Analysts have used dGen to answer questions about load forecasting and integrated resource planning, policy analysis, locational value of distributed energy resources, and more. dGen is open source, and various energy organizations - including independent system operators, regional transmission organizations, and the California Energy Commission - use the model internally.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗