Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Comparison of Virtual Oscillator and Droop Control: Preprint

Virtual oscillator control and droop control are two techniques that can be used to ensure synchronization and power sharing of parallel inverters in islanded operation. VOC relies on the implementation of non-linear Van der Pol oscillator equations in the control system of the inverter, acting upon the time-domain instantaneous inverter current and terminal voltage. On the other hand, DC explicitly computes active and reactive power produced by the inverter and relies on limited bandwidth low-pass filters. Even though both methods can be engineered to produce the same steady-state characteristics, their dynamic performances are significantly different. This paper presents analytical and experimental results that aim to compare both methods. It is shown that VOC is inherently faster and enables minimizing the circulating currents. The results are verified using three 120V, 1kW inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of System Frequency Support Effect of PMSG-WTG Using Torque-Limit-Based Inertial Control

To release the 'hidden inertia' of variable-speed wind turbines for temporary frequency support, a method of torque-limit-based inertial control is proposed in this paper. This method aims to improve the frequency support capability considering the maximum torque restriction of a permanent magnet synchronous generator. The advantages of the proposed method are improved frequency nadir (FN) in the event of an under-frequency disturbance; and avoidance of over-deceleration and a second frequency dip during the inertial response. The system frequency response is different, with different slope values in the power-speed plane when the inertial response is performed. The proposed method is evaluated in a modified three-machine, nine-bus system. The simulation results show that there is a trade-off between the recovery time and FN, such that a gradual slope tends to improve the FN and restrict the rate of change of frequency aggressively while causing an extension of the recovery time. These results provide insight into how to properly design such kinds of inertial control strategies for practical applications.

17 WIND ENERGY↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

Adaptive Runtime Features For Distributed Graph Algorithms

Performance of distributed graph algorithms can benefit greatly by forming rapport between algorithmic abstraction and the underlying runtime system that is responsible for scheduling work and exchanging messages. However, due to their dynamic and irregular nature of computation, distributed graph algorithms written in different programming models impose varying degree of workload pressure on the runtime. To cope with such vastly different workload characteristics, a runtime has to make several trade-offs. One such trade-off arises, for example, when the runtime scheduler has to choose among alternatives such as whether to execute algorithmic work, or progress the network by probing network buffers, or throttle sending messages (termed flow control). This tradeoff decides between optimizing the throughput of a runtime scheduler by increasing the rate of execution of algorithmic work, and reducing the latency of the network messages. Another trade-off exists when a decision has to be made about when to send aggregated messages in buffers (message coalescing). This decision chooses between trading off latency for network bandwidth and vice versa. At any instant, such trade-offs emphasize either on improving the quantity of work being executed (by maximizing the scheduler throughput) or on improving the quality of work (by prioritizing better work). However, encoding static policies for different runtime features (such as flow control, coalescing) can prevent graph algorithms from achieving their full potential, thus can undermine the actual performance of a distributed graph algorithm . In this paper, we investigate runtime support for distributed graph algorithms in the context of two paradigms: variants of wellknown Bulk-Synchronous Parallel model and asynchronous programming model. We explore generic runtime features such as message coalescing (aggregation) and flow control and show that execution policies of these features need to be adjusted over time to make a positive impact on the execution time of a distributed graph algorithm. Since synchronous and asynchronous graph algorithms have different workload characteristics, not all of such runtime features may be good candidates for adaptation. Each of these algorithmic paradigms may require different set of features to be adapted over time. We demonstrate which set of feature(s) can be useful in each case to achieve the right balance of work in the runtime layer. Existing implementation of different graph algorithms can benefit from adapting dynamic policies in the underlying runtime.

Firoz, Jesun S.↗

A Participation Factor-Based Approach for Defining the EMT Model Boundary for Power System Simulations with Inverter-Based Resources

The increasing penetration of inverter-based resources (IBRs) introduces new challenges to power system simulations, particularly with the emergence of fast electromagnetic transient (EMT) dynamics and sub-synchronous oscillations (SSO) that require time-consuming EMT simulations. To reduce the time cost for simulating a large-scale power grid with IBRs, this paper proposes a novel participation factor-based approach for defining a critical zone for detailed EMT modeling and simulations, which includes the IBRs, synchronous generators, and the network components participating significantly in simulated contingencies. Both model-based and response-based methods are introduced for the estimation of participation factors (PFs). The case study on the 240-bus Western Electricity Coordinating Council (WECC) system demonstrates that the EMT zone determined by the proposed approach can effectively capture power system dynamics involving IBRs.

EMT simulation↗

Highly Efficient Compensation-Based Parallelism for Wavefront Loops on GPUs

Wavefront loops are widely used in many scientific applications, e.g., partial differential equation (PDE) solvers and sequence alignment tools. However, due to the data dependencies in wavefront loops, it is challenging to fully utilize the abundant compute units of GPUs and to reuse data through their memory hierarchy. Existing solutions can only optimize for these factors to a limited extent. For example, tiling-based methods optimize memory access but may result in load imbalance; while compensation-based methods, which change the original order of computation to expose more parallelism and then compensate for it, suffer from both global synchronization overhead and limited generality. In this paper, we first prove under which circumstances that breaking data dependencies and properly changing the sequence of computation operators in our compensation-based method does not affect the correctness of results. Based on this analysis, we design a highly efficient compensation-based parallelism on GPUs. Our method provides weighted scan-based GPU kernels to optimize the computation and combines with the tiling method to optimize memory access and synchronization. The performance results on the NVIDIA K80 and P100 GPU platforms demonstrate that our method can achieve significant improvements for four types of real-world application kernels over the state-of-the-art research.

Hou, Kaixi↗

Scenario Decomposition for 0-1 Stochastic Programs: Improvements and Asynchronous Implementation

We recently proposed scenario decomposition algorithm for stochastic 0-1 programs finds an optimal solution by evaluating and removing individual solutions that are discovered by solving scenario subproblems. In our work, we develop an asynchronous, distributed implementation of the algorithm which has computational advantages over existing synchronous implementations of the algorithm. Improvements to both the synchronous and asynchronous algorithm are proposed. We also test the results on well known stochastic 0-1 programs from the SIPLIB test library and is able to solve one previously unsolved instance from the test set.

97 MATHEMATICS AND COMPUTING↗

Voltage Restoration in Microgrids using Temporal Logic Specifications

This paper proposes an energy storage controller synthesis method for voltage restoration in microgrids with respect to temporal logic specifications (TLSs). TLSs is introduced in this paper as a formalism to control the voltage variation of a critical bus against an operational bounds over time. The power system with synchronous generator (SG) connected to a critical load bus is modeled as a set of differential-algebraic equations and a simplified analytical model is derived to describe the voltage variation of this critical bus. The control objective is to schedule an optimal control input signal from a supportive energy storage system (ESS) connected to the critical bus, such that the voltage variation of the latter satisfies the TLSs, such as a finite-time restoration. The proposed control is verified on a lumped distribution system model. With this control diagram, supportive controllers can be designed to make voltage behaviors comply with grid codes and avoid unnecessary relay actions.

Taousser, Fatima Zohra↗

A Novel State-Constrained Primary Control for Grid-Forming Inverters

The problem of operating an AC microgrid with purely inverter-based generating units is considered, and a novel vector control for the constrained grid-forming (GFM) inverters is proposed. The design aims to achieve the primary control objectives of the GFM inverters: voltage establishment, synchronization, and voltage/frequency regulation. It is novel that the proposed control also ensures all operational variables constrained both real-time and for all the time except for low voltage during the period of grid forming. The constraints include frequency, output AC voltage, input DC power, and active/reactive power injections to the grid. Here, in this paper, outcomes of a detailed simulation are presented to demonstrated that the above design objectives are met and that the overall performance is superior due to its unique ability of simultaneously controlling the whole vectors of the inverter state and output.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fast and Accurate Transient Stability Assessment Method Based on Deep Learning: WECC Case Study

Transient stability is one of the critical aspects of power system stability assessment. The increasing integration of inverter-based resources and the retirement of conventional synchronous generators result in the decreasing system inertia and growing complexity of system operating conditions. Using a few selected typical operating conditions cannot guarantee system transient stability in all operating conditions, and the time-domain simulation of all operating conditions requires tremendous time and is often infeasible. This paper proposes a more efficient transient stability assessment method based on deep learning. The binary search method is used to determine the critical clearing time (CCT) in creating training databased by time-domain simulation. This method is fast and accurate with 1 ms resolution. The buses whose CCTs are lower than 200 ms are considered critical buses. Buses close to each other are grouped based on their mutual admittance matrix to reduce the search space of the critical buses. This paper also proposes the generator feature normalization based on the physical model. Case study on the reduced 240-bus WECC system model demonstrates that the proposed method can predict CCT accurately and efficiently.

critical clearing time↗

Investigating Multi-Microgrid Black Start Methods Using Grid-Forming Inverters

This paper examines state-of-the-art microgrid (MG) black-start technologies with grid-forming (GFM) inverter-based resources (IBRs) and proposes black start and interconnection methods for 100% inverter-based MGs. A multiple-MG approach is proposed and compared to the existing methods in a 4-bus, 12-GFM inverter simulation test setup. This investigation involves intelligent synchronization units that enable the autonomous synchronization of multiple MGs based on their terminal measurements. MGs in this setup are held at different loading levels and comprise averaged models of GFM inverters. The results of the black-start techniques are compared, and conclusions are drawn to better prepare MG planners and distribution system operators for next-generation, multi-MG, GFM inverter-based, black-start procedures.

black start↗

Optimal PMU Placement Evaluation for Power System Dynamic State Estimation

Abstract - The synchronized phaor measurements unit (PMU), developed in the 1980s, is concidered to be one of the most important devices in the future of power systems. The recent development of PMU technology provides high-speed, precisely synchronized sensor data, which has been found to be usefule for dynamic, state estimation of power the power grid.

Zhang, Jinghe↗

Extended Frequency Divider for Bus Frequency Estimation Considering Virtual Inertia from DFIGs

Accurate estimation of local bus frequency is important for effectively controlling both synchronous and nonsynchronous generators. As the power grid evolves to accommodate essential reliability services such as virtual inertia from nonsynchronous generators, conventional techniques to estimate frequency face challenges. This paper proposes a new frequency estimation method that can effectively include the inertia contributions from double-fed wind generators (DFIGs). This is achieved through the proposed extended frequency divider formula (FDF) to include the contributions of DFIGs via Thevenin equivalents. The proposed extended FDF does not suffer from numerical issues as compared to existing phasor angle derivative-based approaches. Moreover, the knowledge of the rotor speeds of the synchronous machine and DFIGs as well as of the network admittance matrix allows estimating the frequencies of all buses in the grid, thereby significantly improving system situational awareness with a limited number of measurements. Numerical results on the IEEE 39-bus power system with DFIGs show that the proposed method achieves more accurate bus frequency estimations than the original FDF formula and other approaches based on the numerical derivation of the bus voltage phase angles.

double-fed induction generator↗

Traction Motor Design Trade-Offs with Additively Manufactured Anisotropic Bonded Magnets

Extrusion based big area additive manufacturing (BAAM) has been previously demonstrated for the fabrication of dense anisotropic bonded magnets. This paper reports on design trade-offs when such magnets are employed in a motor designed for electric vehicle applications. An external rotor fractional slot permanent magnet synchronous machine designed with sintered dysprosium free magnets rated for 100kW peak and 50kW continuous power is used as the baseline. The impact of using the bonded BAAM magnets on the motor and inverter volumes, motor loss and cooling systems as well as demagnetization margins is evaluated. It is found that although the motor power density reduces due to the lower energy product of the BAAM magnets, there are other system level benefits including reductions in the cooling system requirement, lower inverter rating and volume, decrease in short circuit current and improved demagnetization marains.

additive manufacturing↗

Dynamic P-Q Capability and Abnormal Operation Analysis of a Wind Turbine with Doubly-Fed Induction Generator

After several accidents occurred in wind farms in the United States and around the world, the subsynchronous oscillation (SSO) issues in grid-connected wind farms have gained serious attention. Particularly, these issues have caused significant challenges to wind turbines with a doubly fed induction generator (DFIG) because it is connected to the grid via both its stator and rotor paths. Traditionally, a P-Q capability chart is utilized to assure the safe operation boundary for a synchronous generator. But the energy conversion characteristics of a DFIG wind turbine are completely different. A critical factor to affect the reliable operation of a DFIG wind turbine is the rated current and pulse-width modulation (PWM) saturation constraints of its power converters. These constraint conditions can be affected by the wind turbine rotating speed and grid conditions. However, a detailed study of DFIG P-Q capability from these perspectives has not been conducted, which has hindered adequate understanding of many abnormal wind turbine operations reported in the literature and the development of advanced control technologies to overcome the challenges. The proposed study in this paper considers vector control implementation to DFIG power electronic converters in the dq reference frame, and the models and algorithms developed for the P-Q capability study have addressed specific DFIG power converter constraints that are different from those of a traditional synchronous generator. The paper especially focuses on exploring the dynamic natures of DFIG P-Q capability under uncertain and variable conditions to explore the root causes of many abnormal operations of DFIG wind turbines reported in the literature. The proposed study is validated through an electromagnetic transient simulation model of a grid-connected DFIG wind turbine. The proposed study has the potential to lead to the development of new DFIG control technologies that can help overcome the challenges for many abnormal operations of DFIG wind turbines.

17 WIND ENERGY↗

Memristive Mixed-Signal Neuromorphic Systems: Energy-Efficient Learning at the Circuit-Level

Neuromorphic computing is non-von Neumann computer architecture for the post Moore’s law era of computing. Since a main focus of the post Moore’s law era is energy-efficient computing with fewer resources and less area, neuromorphic computing contributes effectively in this research. Here in this paper, we present a memristive neuromorphic system for improved power and area efficiency. Our particular mixed-signal approach implements neural networks with spiking events in a synchronous way. Moreover, the use of nano-scale memristive devices saves both area and power in the system. We also provide device-level considerations that make the system more energy-efficient. The proposed system additionally includes synchronous digital long term plasticity, an online learning methodology that helps the system train the neural networks during the operation phase and improves the efficiency in learning considering the power consumption and area overhead.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Assessment of a System Comprising a Single Machine and Inverter with Scalable Ratings

Synchronous machines have traditionally acted as the foundation of large-scale electrical infrastructures and their physical properties have formed the cornerstone of system operations. However, with the increased integration of distributed renewable resources and energy-storage technologies, there is a need to systematically acknowledge the dynamics of power-electronics inverters - the primary energy-conversion interface in such systems - in all aspects of modeling, analysis, and control of the bulk power network. In this paper, we assess the properties of coupled machine-inverter systems by studying an elementary system comprised of a synchronous generator, three-phase inverter, and a load. The inverter model is formulated such that its power rating can be scaled continuously across power levels while preserving its closed-loop response. Accordingly, the properties of the machine-inverter system can be assessed for varying ratios of machine-to-inverter power ratings. After linearizing the model and assessing its eigenvalues, we show that system stability is highly dependent on the inverter current controller and machine exciter, thus uncovering a key concern with mixed machine-inverter systems and motivating the need for next-generation grid-stabilizing inverter controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗