Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

CO2 DIAL sensitivity studies for measurements of atmospheric trace gases

An analysis is presented of the accuracy of infrared differential absorption lidar (DIAL) measurements of trace constituents in the atmosphere. Expressions are derived for the signal-to-noise ratios applicable in the detection of a signal from a scattering cell for the cases of single-detection heterodyne detection and direct detection. Results of computer simulations of the expectation value of the measured return for various measurement conditions are presented which illustrate the sensitivities of plume measurements for horizontal range-resolved and vertical content measurements of NH3 in heterodyne and direct detection. Advantages for long-range measurements of the use of rare isotope laser frequencies, tuning by collision broadening, and closely spaced on and off frequencies are pointed out.

Brockman, P.↗

Investigating the Relationship Between Bolide Entry Angle and Apparent Direction of Infrasound Signal Arrivals

Infrasound sensing offers critical capabilities for detecting and geolocating bolide events globally. However, the observed back azimuths, directions from which infrasound signals arrive at stations, often differ from the theoretical expectations based on the bolide’s peak brightness location. For objects with shallow entry angles, which traverse longer atmospheric paths, acoustic energy may be emitted from multiple points along the trajectory, leading to substantial variability in back azimuth residuals. This study investigates how the entry angle of energetic bolides affects the back azimuth deviations, independent of extrinsic factors such as atmospheric propagation, station noise, and signal processing methodologies. A theoretical framework, the Bolide Infrasound Back-Azimuth EXplorer Model (BIBEX-M), was developed to compute predicted back azimuths solely from geometric considerations. The model quantifies how these residuals vary as a function of source-to-receiver distance, revealing that bolides entering at shallow angles, e.g., 10°, can produce average residuals of 20°, with deviations reaching up to 46° at distances below 1000 km, and remaining significant even at 5000 km (up to 8°). In contrast, bolides with steeper entry angles, e.g., > 60°, show smaller deviations, typically under 5° at 1000 km and diminishing to less than ~1° beyond 5000 km. These findings attest to the need for careful interpretation when evaluating signal detections and estimating bolide locations. This work is not only pertinent to bolides but also to other high-energy, extended-duration atmospheric phenomena such as space debris and reentry events, where similar geometric considerations can influence infrasound arrival directions.

Acoustics↗

Estimation of Arrivals on Green at Signalized Intersections Using Stop-Bar Video Detection

Across the world, traffic congestion is increasing with alarming rapidity. Traffic signal control effectiveness, in coordinated networks, is often investigated in relation to the type of vehicle arrivals at the signalized intersections. Recently, several transportation agencies have switched from traditional loop detectors to video detection. When video cameras are accompanied by computer vision, one can extract more information about traffic “dynamics” than by using traditional inductive loop detectors. Collecting arrival times of multiple vehicles after the first arrival at the stop-bar detector might be challenging when using inductive loop detectors (since after the first arrival, detector status is always occupied). However, emerging video detection systems allow tracking of each vehicle’s entrance time in the detection zone, departure time from the detection zone, and the type of vehicle. This information can be used to estimate vehicular arrival and departure times, which then can be fed into machine learning algorithms to estimate arrivals on green (AOG). However, such research ideas have not been documented so far. Thus, this paper presents an estimation model for AOG, which was developed using multigene genetic programming. A robust experimental dataset was collected from a highly calibrated and validated microsimulation model of an 11-intersection corridor in Chattanooga, TN. The results of the model’s performance analysis showed the high accuracy of the training-, testing-, and validation datasets. The practical benefit of this model is that it can be applied to estimate arrival types at intersections where only stop-bar video detection exists.

Engineering↗

Simultaneous Detection And Estimation Amid Strong Dynamical Effects

Effective signal-to-noise ratio several decibels greater than in previous schemes. Proposed for digital processing of received noisy, binary-phase-modulated radio signal for simultaneous detection of binary modulation and estimation of Doppler phase, frequency, and frequency derivative. Intended for use where relative motion between transmitter and receiver includes large velocities, strong accelerations, and/or intense jerks, resulting in possibly large Doppler frequency shifts with respect to time. Improves reception in radar, mobile/satellite communications, and navigation systems.

Kumar, Rajendra↗

Signal-to-noise ratio for acoustic detection in the deep ocean

A simple method is presented for studying the thermoacoustic wave generated by a heat pulse. The signal-to-noise ratio (S/N) is then calculated for a typical hadronic-electromagnetic cascade in the deep ocean where low frequencies are masked by surface noise. It is found that a maximum useful range of about 16 km is found for typical conditions at 5 km depth. It is shown that in order to obtain useful signals with S/N greater than 100 at distances of 1 to 16 km, the cascade energy must be 10 to the 16th to 10 to the 18th eV. Finally, attention is given to further refinements of the theory of acoustic detection which remain to be investigated.

Bowen, T.↗

The Visibility of Earth Transits

The recent detection of planetary transits of the solar-like star HD 209458 at a distance of 47 parsecs suggest that transits can reveal the presence of Jupiter-size planetary companions in the solar neighborhood. Recent space-based transit searches have achieved photometric precision within an order of magnitude of that required to detect the much smaller transit signal of an earth-size planet around a solar-size star. Laboratory experiments in the presence of realistic noise sources have shown that CCDs can achieve photometric precision adequate to detect the 9.6 E-5 dimming, of the Sun due to a transit of the Earth. Space-based solar irradiance monitoring has shown that the intrinsic variability of the Sun would not preclude such a detection. Transits of the Sun by the Earth would be detectable by observers that reside within a narrow band of sky positions near the ecliptic plane, if the observers possess current Earth epoch levels of technology and astronomical expertise. A catalog of candidate target stars, their properties, and simulations of the photometric Earth transit signal detectability at each target is presented.

Castellano, Tim↗

A directed search for extraterrestrial laser signals

The focus of NASA's Search for Extraterrestrial Intelligence (SETI) Program is on microwave frequencies, where receivers have the best sensitivities for the detection of narrowband signals. Such receivers, when coupled to existing radio telescopes, form an optimal system for broad area searches over the sky. For a directed search, however, such as toward specific stars, calculations show that infrared wavelengths can be equally as effective as radio wavelengths for establishing an interstellar communication link. This is true because infrared telescopes have higher directivities (gains) that effectively compensate for the lower sensitivities of infrared receivers. The result is that, for a given level of transmitted power, the signal to noise ratio for communications is equally as good at infrared and radio wavelengths. It should also be noted that the overall sensitivities of both receiver systems are quite close to their respective fundamental limits: background thermal noise for the radio frequency system and quantum noise for the infrared receiver. Consequently, the choice of an optimum communication frequency may well be determined more by the achievable power levels of transmitters rather than the ultimate sensitivities of receivers at any specific frequency. In the infrared, CO2 laser transmitters with power levels greater than 1 MW can already be built on Earth. For a slightly more advanced civilization, a similar but enormously more powerful laser may be possible using a planetary atmosphere rich in CO2. Because of these possibilities and our own ignorance of what is really the optimum search frequency, a search for narrowband signals at infrared frequencies should be a part of a balanced SETI Program. Detection of narrowband infrared signals is best done with a heterodyne receiver functionally identical to a microwave spectral line receiver. We have built such a receiver for the detection of CO2 laser radiation at wavelengths near 10 microns. The spectrometer uses a high-speed HgCdTe diode as the photomixer and a small CO2 laser as the local oscillator. Output signals in the intermediate frequency range 0.1-2.6 GHz are processed by a 1000-channel acousto-optic signal processor. The receiver is being used on a 1.5-m telescope on Mt. Wilson to survey a selected sample of 150 nearby stars. The current status of the work is discussed along with future project plans.

Betz, A.↗

Source Physics Experiment: Rock Valley Interferometric Synthetic Aperture RADAR Earthquake Detection Study

Seismic signals from 1993 show a series of magnitude (Mw) 3.7 or less seismic events in Rock Valley on the Nevada National Security Site (NNSS). Historic synthetic aperture radar images of that location were found that could provide interferometric synthetic aperture radar (InSAR) measures of the ground height during 1993. Given this historic SAR imagery, we explore answering the question if ground movement from the 1993 Rock Valley earthquake activity could be sensed by remote sensing means. Finding earthquake surface movement would assist in locating the Rock Valley fault and the 1993 earthquake hypocenter where the Source Physics Experiment Phase III series of experiments will be conducted. In this report, we show that InSAR can sense very small height differences, and for the European Radar Satellite-1 InSAR collections during 1992 and 1993 over Rock Valley earth surface movements were measured with 8 mm uplift and 12.5 mm subsidence over isolated areas. One of these earth movement areas coincides with an InSAR image pair coherence drop between March 5, 1993 and June 18, 1993. The coherence drop is over an approximately 13 square km area south southeast of Skull Mountain centered at 36° 43' 30" N latitude and 116° 05' 00" W longitude. Measured small surface movement and a loss of InSAR coherence may be caused by the series of earthquakes. The location of these InSAR detections may also coincide with water drainage or erosion displacement. There are no records to disambiguate the earthquake and erosion earth surface motion possibilities. Therefore, the InSAR findings of earth surface movement by InSAR are inconclusive.

58 GEOSCIENCES↗

Total hydrocarbon analysis by ion mobility spectrometry

Astronauts must be alerted quickly to chemical leaks that compromise their health and the success of their missions. An ideal leak detector would be equally sensitive to all compounds that might constitute a hazard and insensitive to nontoxic compounds. No ideal sensor exists; thus, selection of a methodology is a series of compromises. The commonly used methods are either insensitive at the low exposure levels set by OSHA, NASA, and other organizations or are selectively insensitive to important classes of chemicals such as Freons. After extensive study and experience, the Toxicology Group at JSC has selected ion mobility spectrometry (IMS) for development into a broad range, sensitive detector. In addition to the sensing method, signal processing is important leak detection because a background signal can be expected at all times. The leak-detecting instrument must be programmed to discriminate between authentic leaks and background fluctuations caused by routine operations. The results of an evaluation of the prototype THA is presented in terms related to spacecraft operations. The evaluation included determination of instrumental parameters such as stability and response times. We also included responses to some common components of spacecraft atmospheres in pure form and in binary and ternary mixtures. The output of the four algorithms to the mixtures was found to be noticeably different. These responses are compared on the basis of their utility for signaling a chemical leak. As a means of evaluating its resistance to a falsely positive response, the THA was challenged with carbon dioxide and methane, compounds whose concentrations normally increase in spacecraft air during human habitation. The instrument showed virtually no response to these interferences. Although the prototype THA is designed for space flight, this detector is expected to be useful for field screening at chemical waste dumps and other environmentally sensitive locations.

Cross, John H.↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaics Systems

Self-monitoring and diagnosing technology for photovoltaic (PV) systems is a method to reduce energy production losses. The proposed technology will enable existing panel-level power optimizers and inverters in a PV system to actively perturb the system, measure its response to these small-signal perturbations, and detect any changes in the small-signal impedances. Impedance measurement will be used to identify specific faults and power degradation trends in a PV panel. This information can be used to instantly alert Operations and Maintenance (O&M) personnel of the need for corrective action, thereby reducing energy production losses earlier relative to standard PV systems.

Panchal, Jeet↗

Development, applications, and future of infrared upconversion

Infrared upconversion is a technique that converts linearly polarized infrared photons to photons of higher frequency. The technique can be applied advantageously to the detection of IR radiation because the upconverted signal can be detected by photon-counting devices available for the visible spectral region. In addition, unlike presently available IR detectors, an upconversion device can provide sensitivity to IR radiation without the need for cryogenic cooling. Infrared upconversion was first demonstrated in 1961. By 1974, approximately 100% quantum conversion efficiency and a bandwidth of 1.81 microns had been attained. Photometric detection of IR radiation from various astronomical objects had also been demonstrated. Research is presently under way on the application of upconversion to astronomical spectroscopy and to imaging. The major drawback to the upconversion technique is the sheer bulk of the apparatus involved. It is anticipated that this problem can be overcome by applying the developing technology of integrated optics.

Gurski, T. R.↗

Averaging Sampled Sensor Outputs To Detect Failures

Fluctuating signals smoothed by taking consecutive averages. Sampling-and-averaging technique processes noisy or otherwise erratic signals from number of sensors to obtain indications of failures in complicated system containing sensors. Used under both transient and steady-state conditions. Useful in monitoring automotive engines, chemical-processing plants, powerplants, and other systems in which outputs of sensors contain noise or other fluctuations in measured quantities.

Panossian, Hagop V.↗

Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer

A multichannel electrometer voltmeter that employs a mechanical resonator maintained in sustained amplitude-stabilized oscillation has been developed for the space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Creating a stable oscillator from the mechanical resonator was achieved by employing magnetic induction for sensing the resonator s velocity, and forcing a current through a coil embedded in the resonator to produce a Lorentz actuation force that overcomes the resonator s dissipative losses. Control electronics employing an AGC loop provide conditions for stabilized, constant amplitude harmonic oscillation. The prototype resonator was composed of insulating FR4 printed-wireboard (PWB) material containing a flat, embedded, rectangular coil connected through flexure springs to a base PWB, and immersed in a magnetic field having two regions of opposite field direction generated by four neodymium block magnets. In addition to maintaining the mechanical movement needed for the electrometer s capacitor-probe transducer, this oscillator provides a reference signal for synchronous detection of the capacitor probe s output signal current so drift of oscillation frequency due to environmental effects is inconsequential.

Blaes, Brent R.↗

Bio‐Imaging quorum sensing signal molecules in a soil‐mimic gel

Rhizosphere, the narrow region surrounding plant roots directly influenced by root exudates and the root associated microbiome, plays an important role in plant productivity and the rhizosphere is well known for stimulating microbial metabolic activities. How microbial communities interact to form stable, metabolically interconnected functional communities is an area of intense interest. The question remains on how microbially produced secreted molecules that function as intercellular communication signals shape the structure and function of microbial communities. Our goal is to detect and quantify signal molecules produced by microbes or plants in the root‐soil environment, spatially and temporarily. As a proof‐of‐concept, we are imaging diffusible extracellular microbial metabolites involved in a bacteria‐bacteria communication process called quorum‐sensing. Quorum‐sensing relies on the accumulation of high concentrations of signal molecules in the environment to control bacterial gene expression, influencing rhizosphere colonization and plant health. Local concentration of quorum sensing molecules are determined using aptamer based sensors. Aptamers that can specifically bind the desired signal molecules are selected through SELEX and immobilized on the surface of nano‐porous membranes. Binding of the signal molecules and aptamer covered surface results in changes in surface charge distribution and steric hinderance and thus modifying the transmembrane ionic transport. Changes in transmembrane impedance can be measured through electrochemical impedance spectroscopy methods to monitor local concentrations of signal molecules. Sensor responses were determined for different concentrations of signal molecules and results showed detection of C4‐HSL in a soil‐mimic solution with K D of 10 nM. We demonstrate that the quorum‐sensing signal molecule C4‐homoserine lactone and (C4‐HSL) can rapidly diffuse in a soil‐mimic gel, providing evidence for our use of a soil‐mimic for further aptasensor development and validation. The sensors were then inserted into soil mimic gel for monitoring C4‐HSL diffusion and the resulted impedance changes were used to determine the C4‐HSL concentration at different positions in the gel. Measurements of local C4‐HSL concentrations variation and numerical solution of diffusion equation were used to create 4D images of C4‐HSL molecule diffusion in the soil‐mimic gel.

Jiang, Nianyu↗