Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Study on the parameters of the scanning system for the 300 keV electron accelerator

This paper describes the method to identify the magnetic coil parameters of the scanning system. This locally designed low energy electron accelerator with the present energy of 140 keV will be upgraded to 300 keV. In this accelerator, scanning system is required to deflect the energetic electron beam across a titanium foil in vertical and horizontal direction. The excitation current of the magnetic coil is determined by the energy of the electron beam. Therefore, the magnetic coil parameters must be identified to ensure the matching of the beam energy and excitation coil current. As the result, the essential parameters of the effective lengths for X-axis and Y-axis have been found as 0.1198 m and 0.1134 m and the required excitation coil currents which is dependenton the electron beam energies have be identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution fully vectorial scanning Kerr magnetometer

We report on the development of a high-resolution scanning magnetometer, which fully exploits the vectorial nature of the magneto-optical Kerr effect. The three-dimensional nature of magnetization is at the basis of many micromagnetic phenomena and from these data, we can fully characterize magnetization processes of nanostructures in static and dynamic regimes. Our scanning Kerr magnetometer uses a high numerical aperture microscope objective where the incident light beam can be deterministically deviated from the objective symmetry axis, therefore, both in-plane (via the longitudinal Kerr effect) and out-of-plane (via the polar Kerr effect) components of the magnetization vector may be detected. These components are then separated by exploiting the symmetries of the polar and longitudinal Kerr effects. From four consecutive measurements, we are able to directly obtain the three orthogonal components of the magnetization vector with a resolution of 600 nm. Performance of the apparatus is demonstrated by a measurement of 3D magnetization vector maps showing out-of-plane domains and in-plane domain walls in an yttrium-iron-garnet film and on a study of magnetization reversal in a 4-μm-wide magnetic disk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning three-dimensional x-ray diffraction microscopy using a high-energy microbeam

A scanning three-dimensional X-ray diffraction (3DXRD) microscope apparatus with a high-energy microbeam was installed at the BL33XU Toyota beamline at SPring-8. The size of the 50 keV beam focused using Kirkpatrick-Baez mirrors was 1.3 μm wide and 1.6 μm high in full width at half maximum. The scanning 3DXRD method was tested for a cold-rolled carbon steel sheet sample. A three-dimensional orientation map with 37 {sup 3} voxels was obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production of high density molecular beams with wide velocity scanning

We describe modifications of a pulsed rotating supersonic beam source that improve performance, particularly increasing the beam density and sharpening the pulse profiles. As well as providing the familiar virtues of a supersonic molecular beam (high intensity, narrowed velocity distribution, and drastic cooling of rotation and vibration), the rotating source enables scanning the translational velocity over a wide range. Thereby, beams of any atom or molecule available as a gas can be slowed or speeded. Using Xe beams in the slowing mode, we have obtained lab speeds down to about 40 ± 5 m/s with density near 10{sup 11} cm{sup −3} and in the speeding mode lab speeds up to about 660 m/s and density near 10{sup 14} cm{sup −3}. We discuss some congenial applications. Providing low lab speeds can markedly enhance experiments using electric or magnetic fields to deflect, steer, or further slow polar or paramagnetic molecules. The capability to scan molecular speeds facilitates merging velocities with a codirectional partner beam, enabling study of collisions at very low relative kinetic energies, without requiring either beam to be slow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning nuclear electric resonance microscopy using quantum-Hall-effect breakdown

We present a scanning nuclear-spin resonance (NSR) method that incorporates resistive detection with electric-field induced NSR locally excited by a scanning metallic probe. In the quantum-Hall effect breakdown regime, NSR intensity mapping at both the fundamental NSR frequency f{sub 75As} and twice the frequency 2f{sub 75As} demonstrates the capability to probe the distribution of nuclear polarization, particularly in a semiconductor quantum well. We find that f{sub 75As} NSR excitation drives not only local NSR but also spatially overlapped nonlocal NSR, which suppresses the maximum intensity of local NSR, while the 2f{sub 75As} NSR yields purely local excitation conferring a larger intensity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonlinear threshold effect in the Z-scan method of characterizing limiters for high-intensity laser light

A threshold model is described which permits one to determine the properties of limiters for high-powered laser light. It takes into account the threshold characteristics of the nonlinear optical interaction between the laser beam and the limiter working material. The traditional non-threshold model is a particular case of the threshold model when the limiting threshold is zero. The nonlinear characteristics of carbon nanotubes in liquid and solid media are obtained from experimental Z-scan data. Specifically, the nonlinear threshold effect was observed for aqueous dispersions of nanotubes, but not for nanotubes in solid polymethylmethacrylate. The threshold model fits the experimental Z-scan data better than the non-threshold model. Output characteristics were obtained that integrally describe the nonlinear properties of the optical limiters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Etching of Cr tips for scanning tunneling microscopy of cleavable oxides

Here, we report a detailed three-step roadmap for the fabrication and characterization of bulk Cr tips for spin-polarized scanning tunneling microscopy. Our strategy uniquely circumvents the need for ultra-high vacuum preparation of clean surfaces or films. First, we demonstrate the role of ex situ electrochemical etch parameters on Cr tip apex geometry, using scanning electron micrographs of over 70 etched tips. Second, we describe the suitability of the in situ cleaved surface of the layered antiferromagnet La 1.4 Sr 1.6 Mn 2 O 7 to evaluate the spin characteristics of the Cr tip, replacing the ultra-high vacuum-prepared test samples that have been used in prior studies. Third, we outline a statistical algorithm that can effectively delineate closely spaced or irregular cleaved step edges, to maximize the accuracy of step height and spin-polarization measurements.

36 MATERIALS SCIENCE↗

X-ray magnetic circular dichroism and near-edge X-ray absorption fine structure of buried interfacial magnetism measured by using a scanning tunneling microscope tip

Magnetism at buried interfaces plays a crucial role in many emerging phenomena, but detection of interfacial magnetism in close proximity to a surface with elemental and chemical sensitivity is a challenging task. Here, we use a low temperature synchrotron x-ray scanning tunneling microscopy to investigate x-ray magnetic circular dichroism and near edge x-ray absorption fine structure of La 0.67 Sr 0.33 MnO 3 -LaNiO 3 superlattices in the absence of a magnetic field. In stark contrast to the weak magnetic signal of Mn when the La 0.67 Sr 0.33 MnO 3 layers are located on top, a robust x-ray magnetic circular dichroism signal is detected when they are buried underneath the LaNiO 3 layers. The near edge x-ray absorption fine structure reveals the valence states of the manganese while the oxygen K- edge x-ray absorption spectra show an increase in hole formation indicating a cogent charge transfer at the LaNiO 3 /La 0.67 Sr 0.33 MnO 3 interface. This work demonstrates that scanning tunneling microscopy can be extended to the synchrotron X-ray study of buried interfaces by controlling the sample-tip (e.g., detector) separation in the nanometer regime. The close sample-tip proximity further provides a path toward probing of small lateral areas with zero-field measurements in multi-domain samples.

36 MATERIALS SCIENCE↗

Fly scan apparatus for high pressure research using diamond anvil cells

In this paper, the hardware and software used to execute fly scans at Sector 16 of the Advanced Photon Source is described. The system design and capabilities address dimensions and time scales relevant to samples in high pressure diamond anvil cells. The time required for routine sample positioning and centering is significantly reduced and, more importantly, the time savings associated with fly scanning makes it feasible for users to routinely generate two-dimensional x-ray transmission and x-ray diffraction maps. Consequently, this facilitates an important shift in high pressure research as experimentalists embrace the study of heterogeneous and minute sample volumes in the diamond anvil cell.

47 OTHER INSTRUMENTATION↗

Multimode scanning X-ray diffraction microscopy for diamond anvil cell experiments

We have designed and implemented a new experimental system for fast mapping of crystal structures and other structural features of materials under high pressure at the High Pressure Collaborative Access Team, Sector 16 of the Advanced Photon Source. The system utilizes scanning X-ray diffraction microscopy (SXDM) and is optimized for use with diamond anvil cell devices. In SXDM, the X-ray diffraction (XRD) is collected in a forward scattering geometry from points on a two-dimensional grid by fly-scanning the sample with respect to a micro-focused X-ray beam. The recording of XRD is made during the continuous motion of the sample using a fast (millisecond) X-ray area detector in synchrony with the sample positioners, resulting in a highly efficient data collection for SXDM. A new computer program, X-ray Diffractive Imaging (XDI), has been developed with the SXDM system. The XDI program provides a graphical interface for constructing and displaying the SXDM images in several modes: (1) phase mapping based on structural information, (2) pressure visualization based on the equation of state, (3) microstructural features mapping based on peak shape parameters, and (4) grain size and preferred-orientation based on peak shape parameters. The XDI is a standalone program and can be generally used for displaying SXDM images. Two examples of iron and zirconium samples under high pressure are presented to demonstrate the applications of SXDM. Published under license by AIP Publishing.

47 OTHER INSTRUMENTATION↗

3D scanning and 3D printing AlSi10Mg single crystal mounts for neutron scattering

Here, we present methods to quantify sample shapes and generate sample mounts as motivated by the needs of neutron scattering experiments. The 3D sample scanning was performed using photogrammetry and laser scanning, and a comparison is made between the two techniques. The aluminum alloy AlSi10Mg is shown to have favorable properties for many types of mounts used in neutron scattering. Parts were first prototyped with 3D plastic printers, and then, 3D AlSi10Mg prints were made. The final additively manufactured part holds the sample with more points of contact than is possible with traditional manufacturing. The goodness of fit between the mount and sample was measured by x-ray tomography.

47 OTHER INSTRUMENTATION↗

Electronic structure of epitaxially grown and regrown GaN pn junctions characterized by scanning Kelvin probe and capacitance microscopy

Epitaxial regrowth of GaN pn junctions is a key technology for realization of a variety of high-performance GaN power electronic devices. However, the regrowth process can introduce impurities and defects that degrade a device’s performance. Here, we show that scanning Kelvin probe force microscopy and scanning capacitance microscopy can be used in a cross-sectional geometry to probe dopant distributions and an electronic structure in epitaxially grown GaN pn junctions. These measurements enable profiling of potential and dopant distributions across GaN pn junctions produced by uninterrupted epitaxial growth and by regrowth on an etched surface. Clear differences are observed in comparisons to the electronic structure of these two types of junctions that can be correlated with results of complementary characterization of dopant distributions reported for similarly grown structures. These measurements also suggest the presence of defects in etch-and-regrow pn junction structures that extend nearly 1 μm below the regrown interface.

Kim, Tae-Hyeon (ORCID:0000000341530617)↗

AL4GAP: Active learning workflow for generating DFT-SCAN accurate machine-learning potentials for combinatorial molten salt mixtures

Machine learning interatomic potentials have emerged as a powerful tool for bypassing the spatiotemporal limitations of ab initio simulations, but major challenges remain in their efficient parameterization. We present AL4GAP, an ensemble active learning software workflow for generating multicomposition Gaussian approximation potentials (GAP) for arbitrary molten salt mixtures. The workflow capabilities include: (1) setting up user-defined combinatorial chemical spaces of charge neutral mixtures of arbitrary molten mixtures spanning 11 cations (Li, Na, K, Rb, Cs, Mg, Ca, Sr, Ba and two heavy species, Nd, and Th) and 4 anions (F, Cl, Br, and I), (2) configurational sampling using low-cost empirical parameterizations, (3) active learning for down-selecting configurational samples for single point density functional theory calculations at the level of Strongly Constrained and Appropriately Normed (SCAN) exchange-correlation functional, and (4) Bayesian optimization for hyperparameter tuning of two-body and many-body GAP models. Here, we apply the AL4GAP workflow to showcase high throughput generation of five independent GAP models for multicomposition binary-mixture melts, each of increasing complexity with respect to charge valency and electronic structure, namely: LiCl–KCl, NaCl–CaCl 2 , KCl–NdCl 3 , CaCl 2 –NdCl 3 , and KCl–ThCl 4 . Our results indicate that GAP models can accurately predict structure for diverse molten salt mixture with density functional theory (DFT)-SCAN accuracy, capturing the intermediate range ordering characteristic of the multivalent cationic melts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atom-resolved imaging with a silicon tip integrated into an on-chip scanning tunneling microscope

Limited throughput is a shortcoming of the Scanning Tunneling Microscope (STM), particularly when used for atomically precise lithography. To address this issue, we have developed an on-chip STM based on Microelectromechanical-Systems (MEMS) technology. The device reported here has one degree of freedom, replacing the Z axis in a conventional STM. The small footprint of the on-chip STM provides a great opportunity to increase STM throughput by incorporating a number of on-chip STMs in an array to realize parallel STM. The tip methodology adopted for the on-chip STM presented here, which is a batch-fabricated Si tip, makes our design conducive to this goal. In this work, we investigate the capability of this on-chip STM with an integrated Si tip for STM imaging. We integrate the on-chip STM into a commercial ultrahigh-vacuum STM system and perform imaging with atomic resolution on par with conventional STMs but at higher scan speeds due to the higher sensitivity of the MEMS actuator relative to a piezotube. The results attest that it is possible to achieve a parallel and high-throughput STM platform, which is a fully batch-fabricated MEMS STM nanopositioner capable of performing atomic-resolution STM imaging.

Instruments & Instrumentation↗

Wavefront distortion correction in scanning tunneling microscope image

Here, we report an algorithm to identify and correct distorted wavefronts in atomic resolution scanning tunneling microscope images. This algorithm can be used to correct nonlinear in-plane distortions without prior knowledge of the physical scanning parameters, the characteristics of the piezoelectric actuator, or individual atom positions. The 2D image is first defined as a sum of sinusoidal plane waves, where a nonlinear distortion renders a curve for an otherwise ideal linear wavefront. Using the Fourier transforms of local areas of the image, the algorithm generates a wavefront vector field. The identified wavefronts are subsequently linearized for each plane wave without changing lattice orders, giving rise to distortion corrections. Our algorithm is complementary to conventional post-processing algorithms that require prior detection of real space features, which can also be used to correct nonlinear distortions in 2D images acquired by other microscopy techniques.

47 OTHER INSTRUMENTATION↗

Ultrafast state-selective tunneling in two-dimensional semiconductors with a phase- and amplitude-controlled THz-scanning tunneling microscope

THz-pulse driven scanning tunneling microscopy (THz-STM) enables access to the ultrafast quantum dynamics of low-dimensional material systems at simultaneous ultrafast temporal and atomic spatial resolution. State-selective tunneling requires precise amplitude and phase control of the THz pulses combined with quantitative near-field waveform characterization. Here, we employ our state-of-the-art THz-STM with multi-MHz repetition rates, efficient THz generation, and precisely tunable THz waveforms to investigate a single sulfur vacancy in monolayer MoS2. We demonstrate that 2D transition metal dichalcogenides (TMDs) are an ideal platform for near-field waveform sampling by THz cross-correlation. Furthermore, we determine the THz voltage via QEV scans, which measure the THz rectified charge Q as a function of THz field amplitude E and dc bias Vdc. Mapping the complex energy landscape of localized states with a resolution down to 0.01 electrons per pulse facilitates state-selective tunneling to the HOMO and LUMO orbitals of a charged sulfur vacancy.

Materials Science↗