Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Impact of boron-interstitial clusters on Hall scattering factor in high-dose boron-implanted ultrashallow junctions

The Hall scattering factor r{sub H} has been determined for holes in high-dose boron-implanted ultrashallow junctions containing high concentrations of boron-interstitial clusters (BICs), combining scanning capacitance microscopy, nanospreading resistance, Hall effect, and secondary ion mass spectroscopy measurements. A value of r{sub H}=0.74{+-}0.1 has been found in reference defect-free fully activated junctions, in good agreement with the existing literature. In the case of junctions containing high concentrations of immobile and electrically inactive BICs, and independently of the implant or the annealing process, the r{sub H} value has been found to be equal to 0.95{+-}0.1. The increase in the r{sub H} value is explained in terms of the additional scattering centers associated to the presence of high concentrations of BICs.

36 MATERIALS SCIENCE↗

SU-F-T-218: Validation of An In-Vivo Proton Range Verification Method for Reducing the Risk of Permanent Alopecia in the Treatment of Pediatric Medulloblastoma

Purpose: The clinical commissioning of a workflow for pre-treatment range verification/adjustment for the head treatment of pediatric medulloblastoma patients, including dose monitoring during treatment. Methods: An array of Si-diodes (DIODES Incorporated) is placed on the patient skin on the opposite side to the beam entrance. A “scout” SOBP beam, with a longer beam range to cover the diodes in its plateau, is delivered; the measured signal is analyzed and the extracted water equivalent path lengths (WEPL) are compared to the expected values, revealing if a range correction is needed. Diodes stay in place during treatment to measure dose. The workflow was tested in solid water and head phantoms and validated against independent WEPL measurements. Both measured WEPL and skin doses were compared to computed values from the TPS (XiO); a Markus chamber was used for reference dose measurements. Results: The WEPL accuracy of the method was verified by comparing it with the dose extinction method. It resulted, for both solid water and head phantom, in the sub-millimeter range, with a deviation less than 1% to the value extracted from the TPS. The accuracy of dose measurements in the fall-off part of the dose profile was validated against the Markus chamber. The entire range verification workflow was successfully tested for the mock-treatment of head phantom with the standard delivery of 90 cGy per field per fraction. The WEPL measurement revealed no need for range correction. The dose measurements agreed to better than 4% with the prescription dose. The robustness of the method and workflow, including detector array, hardware set and software functions, was successfully stress-tested with multiple repetitions. Conclusion: The performance of the in-vivo range verification system and related workflow meet the clinical requirements in terms of the needed WEPL accuracy for pretreatment range verification with acceptable dose to the patient.

60 APPLIED LIFE SCIENCES↗

The spectral classification of chromospherically active binary stars with composite spectra

This paper presents and analyzes blue and red-wavelength high-resolution spectra of twelve chromospherically active binary or triple systems with composite spectra. Spectral classifications for the individual stellar components are derived by means of the 'spectrum-synthesis' technique and are compared to stellar evolutionary models and observed masses and/or mass ratios. Also presented is a carefully selected set of MK reference stars of luminosity class III, IV, and V, and spectral type A9-K5, and v sin i less than 10 km/s, to cover the spectral range of the components of chromospherically active binary systems of the RS CVn-type. New values of v sin i are determined for some of the reference and program stars. Two spectroscopic binaries have been discovered.

Strassmeier, K. G.↗

SU-E-T-784: Using MLC Log Files for Daily IMRT Delivery Verification

Purpose: To verify daily intensity modulated radiation therapy (IMRT) treatments using multi-leaf collimator (MLC) log files. Methods: The MLC log files from a NovalisTX Varian linear accelerator were used in this study. The MLC files were recorded daily for all patients undergoing IMRT or volumetric modulated arc therapy (VMAT). The first record of each patient was used as reference and all records for subsequent days were compared against the reference. An in house MATLAB software code was used for the comparisons. Each MLC log file was converted to a fluence map (FM) and a gamma index (γ) analysis was used for the evaluation of each daily delivery for every patient. The tolerance for the gamma index was set to 2% dose difference and 2mm distance to agreement while points with signal of 10% or lower of the maximum value were excluded from the comparisons. Results: The γ between each of the reference FMs and the consecutive daily fraction FMs had an average value of 99.1% (ranged from 98.2 to 100.0%). The FM images were reconstructed at various resolutions in order to study the effect of the resolution on the γ and at the same time reduce the time for processing the images. We found that the comparison of images with the highest resolution (768×1024) yielded on average a lower γ (99.1%) than the ones with low resolution (192×256) (γ 99.5%). Conclusion: We developed an in-house software that allows us to monitor the quality of daily IMRT and VMAT treatment deliveries using information from the MLC log files of the linear accelerator. The information can be analyzed and evaluated as early as after the completion of each daily treatment. Such tool can be valuable to assess the effect of MLC positioning on plan quality, especially in the context of adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

Large-Volume Injection and Assessment of Reference Standards for n -Alkane δD and δ 13 C Analysis via Gas Chromatography Isotope Ratio Mass Spectrometry

Compound-specific stable isotope analysis of hydrogen (δD) and carbon (δ 13 C) in organic compounds is a valuable tool in biogeochemical research. A key limitation of this method is the relatively large amount of sample required to achieve desirable precision. We developed a large-volume (20 μL) injection method that allows for high throughput analysis of less concentrated samples and tested it for δ 13 C and δD measurements of n-alkanes. We also conducted a comparison of reference standards and assessed several methods to normalize and correct n-alkane δD and δ13C measurements. The mean precision of the δD method based on 233 environmental n-alkane samples (two to three replications per sample) is 4.0‰ (1σ, estimated from the weighted mean of the pooled unbiased standard deviations) and 0.46‰ (1σ) for δ 13 C from 37 environmental samples (two to three replications per sample). The evaluation of reference standards shows that the use of n-alkane standards with large offsets in δD values in adjacent n-alkane chains can lead to biases in measurement correction. The large-volume injection method shows good reproducibility of δ 13 C and δD measurements of n-alkanes and reduces the required sample concentration by about 80%. We propose that for δD measurements, a reference standard set should be used in which each reference standard has a limited range of δD values and no adjacent n-alkane chains, to minimize memory effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ALSEP-quasar differential VLBI

A program of ALSEP-quasar very-long-baseline interferometry (VLBI) is being carried out. These observations employ primarily a 'four-antenna' technique whereby simultaneous observations with two antennas at each end of an intercontinental baseline are used to derive the differential interferometric phase between a compact extragalactic radio source (usually a quasar) and a number of ALSEP transmitters on the lunar surface. A continuous ALSEP-quasar differential phase history over a period of a few hours will lead to milliarcsecond angular accuracy in measuring the lunar position against the quasar reference frame if suitable calibration measurements are obtained. Development of this application of the four-antenna technique has been underway for more than a year and is producing high-quality data utilizing Deep Space Network stations. These high-accuracy observations are of value to tie the lunar ephemeris to a nearly inertial extragalactic reference frame, to test gravitational theories, and to measure the earth-moon tidal friction interaction.

Slade, M. A.↗

Secondary Ion Mass Spectrometry Bias on Isotope Ratios in Dolomite-Ankerite, Part II: δ 13 C Matrix Effects

Here, this study is Part II of a series that documents the development of a suite of calibration reference materials for in situ SIMS analysis of stable isotope ratios in Ca-Mg-Fe carbonates. Part I explored the effects of Fe 2+ substitution on SIMS δ18O bias measured from the dolomite–ankerite solid solution series [CaMg(CO3)2–CaFe(CO 3 ) 2 ], whereas this complementary work explores the compositional dependence of SIMS δ 13 C bias (calibrated range: Fe# = 0.004–0.789, where Fe# = molar Fe/(Mg+Fe)). Under routine operating conditions for carbonate δ 13 C analysis at WiscSIMS (CAMECA IMS 1280), the magnitude of instrumental bias increased exponentially by 2.5–5.5‰ (session-specific) with increasing Fe-content in the dolomite structure, but appeared insensitive to minor Mn substitution [< 2.6 mole % Mn/(Ca+Mg+Fe+Mn)]. The compositional dependence of bias (i.e., the matrix effect) was expressed using the Hill equation, yielding calibration residual values ≤ 0.3‰ relative to CRM NBS-19 for eleven carbonate reference materials (6-μm-diameter spot size measurements). Based on the spot-to-spot repeatability of a drift monitor material that ‘bracketed’ each set of ten sample-spot analyses, the analytical precision was ± 0.6–1.2‰ (2s, standard deviations). The analytical uncertainty for individual sample analyses was approximated by combining the precision and calibration residual values (propagated in quadrature), suggesting an uncertainty of ± 1.0–1.5‰ (2s).

58 GEOSCIENCES↗

Long-term evaluation of air sensor technology under ambient conditions in Denver, Colorado

Air pollution sensors are quickly proliferating for use in a wide variety of applications, with a low price point that supports use in high-density networks, citizen science, and individual consumer use. This emerging technology motivates the assessment under real-world conditions, including varying pollution levels and environmental conditions. A seven-month, systematic field evaluation of low-cost air pollution sensors was performed in Denver, Colorado, over 2015–2016; the location was chosen to evaluate the sensors in a high-altitude, cool, and dry climate. A suite of particulate matter (PM), ozone (O 3 ), and nitrogen dioxide (NO 2 ) sensors were deployed in triplicate and were collocated with federal equivalent method (FEM) monitors at an urban regulatory site. Sensors were evaluated for their data completeness, correlation with reference monitors, and ability to reproduce trends in pollution data, such as daily concentration values and wind-direction patterns. Most sensors showed high data completeness when dataloggers were functioning properly. The sensors displayed a range of correlations with reference instruments, from poor to very high (e.g., hourly-average PM Pearson correlations with reference measurements varied from 0.01 to 0.86). Some sensors showed a change in response to laboratory audits/testing from before the sampling campaign to afterwards, such as Aeroqual, where the O 3 response slope changed from about 1.2 to 0.6. Some PM sensors measured wind-direction and time-of-day trends similar to those measured by reference monitors, while others did not. This study showed different results for sensor performance than previous studies performed by the U.S. EPA and others, which could be due to different geographic location, meteorology, and aerosol properties. These results imply that continued field testing is necessary to understand emerging air sensing technology.

54 ENVIRONMENTAL SCIENCES↗

Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data

Purpose: Accurate data regarding linear accelerator (Linac) radiation characteristics are important for treatment planning system modeling as well as regular quality assurance of the machine. The Imaging and Radiation Oncology Core-Houston (IROC-H) has measured the dosimetric characteristics of numerous machines through their on-site dosimetry review protocols. Photon data are presented and can be used as a secondary check of acquired values, as a means to verify commissioning a new machine, or in preparation for an IROC-H site visit. Methods: Photon data from IROC-H on-site reviews from 2000 to 2014 were compiled and analyzed. Specifically, data from approximately 500 Varian machines were analyzed. Each dataset consisted of point measurements of several dosimetric parameters at various locations in a water phantom to assess the percentage depth dose, jaw output factors, multileaf collimator small field output factors, off-axis factors, and wedge factors. The data were analyzed by energy and parameter, with similarly performing machine models being assimilated into classes. Common statistical metrics are presented for each machine class. Measurement data were compared against other reference data where applicable. Results: Distributions of the parameter data were shown to be robust and derive from a student’s t distribution. Based on statistical and clinical criteria, all machine models were able to be classified into two or three classes for each energy, except for 6 MV for which there were eight classes. Quantitative analysis of the measurements for 6, 10, 15, and 18 MV photon beams is presented for each parameter; supplementary material has also been made available which contains further statistical information. Conclusions: IROC-H has collected numerous data on Varian Linacs and the results of photon measurements from the past 15 years are presented. The data can be used as a comparison check of a physicist’s acquired values. Acquired values that are well outside the expected distribution should be verified by the physicist to identify whether the measurements are valid. Comparison of values to this reference data provides a redundant check to help prevent gross dosimetric treatment errors.

60 APPLIED LIFE SCIENCES↗

Validation of Scale-Derived Ages in Wild Juvenile and Adult Steelhead Using Parental-Based Tagging

Abstract Accurate age information is a critical component in fisheries monitoring, management, and research. The ability to assign accurate ages to fish by using nonlethal structures is vital in calculating cohort productivity for fish species with low abundances and variable life histories. A common nonlethal method to assign ages is by interpretation of patterns in scales. Validation of ages is not easily obtained for free-ranging fishes; however, the development of genetic “tags” has expanded age validation opportunities. In this study, we used parental-based genetic tagging to validate ages determined from scales collected from juvenile and adult steelhead Oncorhynchus mykiss in two streams within the Snake River basin. Juvenile scale ages were in agreement with 93% of the known ages. Adult scale ages were in agreement with 89% of the known ages. Although overall bias in juvenile ages was very low, we saw a slight positive bias in younger fish (young of the year and age 1) and a small negative bias in older juveniles (ages 2–4). A small negative bias in ages of adults was a consequence of errors in freshwater age. The errors observed did not significantly bias age compositions because the 90% confidence intervals about the age proportions based on scales contained the known proportions; therefore, scale analysis is an acceptable method for assigning ages to Snake River steelhead. We discuss the value of validated known-age scales as a reference collection, and as an illustrative use, we constructed a circulus count guide to aid technicians in identifying missing annuli and distinguishing true from false annuli. To demonstrate the use of the circulus guidelines, we reanalyzed samples with age discrepancies, applying the circulus count data and the known age to identify mistakes.

Reinhardt, Leslie↗

Indentation size effect in tungsten: Quantification of geometrically necessary dislocations underneath the indentations using HR-EBSD

Highlights: • Revealed the dislocation structure below nanoindentations via ECCI and HR-EBSD. • Experimentally quantification of GND densities, with higher GND densities at lower depths. • Qualitative validation of the Nix-Gao model on the indentation size effect. - Abstract: During indentation testing of the low defect density crystalline materials, higher hardness values are found at lower indentation depths, which is referred to as an indentation size effect. The depth-dependence of hardness can be described by the Nix-Gao model, which is based on the concept of Geometrically Necessary Dislocations (GNDs). The underlying dislocation mechanism remains, however, unclear and requires independent measurement of GND density below the indentation. In the present work, the depth-dependency of the GND density is quantified underneath the Berkovich indentations in tungsten via high-resolution electron backscatter diffraction. There a higher GND density is found for lower indentation depths, resulting in a higher Taylor hardness for measured GND density.

36 MATERIALS SCIENCE↗

Influence of compensator thickness, field size, and off-axis distance on the effective attenuation coefficient of a cerrobend compensator for intensity-modulated radiation therapy

Intensity-modulated radiation therapy (IMRT) can be performed by using compensators. To make a compensator for an IMRT practice, it is required to calculate the effective attenuation coefficient (μ{sub eff}) of its material, which is affected by various factors. We studied the effect of the variation of the most important factors on the calculation of the μ{sub eff} of the cerrobend compensator for 6-MV photon beams, including the field size, compensator thickness, and off-axis distance. Experimental measurements were carried out at 100 cm source-to-surface distance and 10 cm depth for the 6-MV photon beams of an Elekta linac using various field size, compensator thickness, and off-axis settings. The field sizes investigated ranged from 4 × 4 to 25 × 25 cm{sup 2} and the cerrobend compensator thicknesses from 0.5–6 cm. For a fixed compensator thickness, variation of the μ{sub eff} with the field size ranged from 3.7–6.8%, with the highest value attributed to the largest compensator thickness. At the reference field size of 10 × 10 cm{sup 2}, the μ{sub eff} varied by 16.5% when the compensator thickness was increased from 0.5–6 cm. However, the variation of the μ{sub eff} with the off-axis distance was only 0.99% at this field size, whereas for the largest field size, it was more significant. Our results indicated that the compensator thickness and field size have the most significant effect on the calculation of the compensator μ{sub eff} for the 6-MV photon beam. Therefore, it is recommended to consider these parameters when calculating the compensator thickness for an IMRT practice designed for these beams. The off-axis distance had a significant effect on the calculation of the μ{sub eff} only for the largest field size. Hence, it is recommended to consider the effect of this parameter only for field sizes larger than 25 × 25 cm{sup 2}.

07 ISOTOPE AND RADIATION SOURCES↗

Nuclear Data Sheets for A=242

Here, detailed level schemes, decay schemes, band structure, and the experimental data on which they are based are presented for all nuclei with mass number A=242. The experimental data are evaluated and adopted values are given for level and radiation properties. For references on theory refer to the NSR file at the web site given below under Cutoff Date:. This evaluation replaces the A=242 publication by Y. A. Akovali in Nuclear Data Sheets 96, 177 (2002) (2002Ak06).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Estimation of Hybrid Quantum Mechanical Molecular Mechanical Polarization Energies for Small Molecules Using Polarizable Force-Field Approaches

Here in this work, we report two polarizable molecular mechanics (polMM) force field models for estimating the polarization energy in hybrid quantum mechanical molecular mechanical (QM/MM) calculations. These two models, named the potential of atomic charges (PAC) and potential of atomic dipoles (PAD), are formulated from the ab initio quantum mechanical (QM) response kernels for the prediction of the QM density response to an external molecular mechanical (MM) environment (as described by external point charges). The PAC model is similar to fluctuating charge (FQ) models because the energy depends on external electrostatic potential values at QM atomic sites; the PAD energy depends on external electrostatic field values at QM atomic sites, resembling induced dipole (ID) models. To demonstrate their uses, we apply the PAC and PAD models to 12 small molecules, which are solvated by TIP3P water. The PAC model reproduces the QM/MM polarization energy with a R 2 value of 0.71 for aniline (in 10,000 TIP3P water configurations) and 0.87 or higher for other eleven solute molecules, while the PAD model has a much better performance with R 2 values of 0.98 or higher. The PAC model reproduces reference QM/MM hydration free energies for 12 solute molecules with a RMSD of 0.59 kcal/mol. The PAD model is even more accurate, with a much smaller RMSD of 0.12 kcal/mol, with respect to the reference. Lastly, this suggests that polarization effects, including both local charge distortion and intramolecular charge transfer, can be well captured by induced dipole type models with proper parametrization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BiasMDP: Carrier lifetime characterization technique with applied bias voltage

A characterization method is presented, which determines fixed charge and interface defect densities in passivation layers. This method bases on a bias voltage applied to an electrode on top of the passivation layer. During a voltage sweep, the effective carrier lifetime is measured by means of microwave detected photoconductivity. When the external voltage compensates the electric field of the fixed charges, the lifetime drops to a minimum value. This minimum value correlates to the flat band voltage determined in reference impedance measurements. This correlation is measured on p-type silicon passivated by Al{sub 2}O{sub 3} and Al{sub 2}O{sub 3}/HfO{sub 2} stacks with different fixed charge densities and layer thicknesses. Negative fixed charges with densities of 3.8 × 10{sup 12 }cm{sup −2} and 0.7 × 10{sup 12 }cm{sup −2} are determined for Al{sub 2}O{sub 3} layers without and with an ultra-thin HfO{sub 2} interface, respectively. The voltage and illumination dependencies of the effective carrier lifetime are simulated with Shockley Read Hall surface recombination at continuous defects with parabolic capture cross section distributions for electrons and holes. The best match with the measured data is achieved with a very low interface defect density of 1 × 10{sup 10 }eV{sup −1} cm{sup −2} for the Al{sub 2}O{sub 3} sample with HfO{sub 2} interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dissociation curves of diatomic molecules: A DC-DFT study

We investigate dissociation of diatomic molecules using standard density functional theory (DFT) and density-corrected density functional theory (DC-DFT) compared with CCSD(T) results as reference. The results show the difference between the HOMO values of dissociated atomic species often can be used as an indicator whether DFT would predict the correct dissociation limit. DFT predicts incorrect dissociation limits and charge distribution in molecules or molecular ions when the fragments have large HOMO differences, while DC-DFT and CCSD(T) do not. The criteria for large HOMO difference is about 2 ∼ 4 eV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-similar Reynolds-averaged mechanical–scalar turbulence models for Rayleigh–Taylor mixing induced by power-law accelerations in the small Atwood number limit

Analytical self-similar solutions to two-, three-, and four-equation Reynolds-averaged mechanical–scalar turbulence models describing turbulent Rayleigh–Taylor mixing driven by a temporal power-law acceleration are derived in the small Atwood number (Boussinesq) limit. The solutions generalize those previously derived for constant acceleration Rayleigh–Taylor mixing for models based on the turbulent kinetic energy K and its dissipation rate ε, together with the scalar variance S and its dissipation rate χ [O. Schilling, “Self-similar Reynolds-averaged mechanical–scalar turbulence models for Rayleigh–Taylor, Richtmyer–Meshkov, and Kelvin–Helmholtz instability-induced mixing in the small Atwood number limit,” Phys. Fluids 33, 085129 (2021)]. The turbulent fields are expressed in terms of the model coefficients and power-law exponent, with their temporal power-law scalings obtained by requiring that the self-similar equations are explicitly time-independent. Mixing layer growth parameters and other physical observables are obtained explicitly as functions of the model coefficients and parameterized by the exponent of the power-law acceleration. Values for physical observables in the constant acceleration case are used to calibrate the two-, three-, and four-equation models, such that the self-similar solutions are consistent with experimental and numerical simulation data corresponding to a canonical (i.e., constant acceleration) Rayleigh–Taylor turbulent flow. The calibrated four-equation model is then used to numerically reconstruct the mean and turbulent fields, and turbulent equation budgets across the mixing layer for several values of the power-law exponent. Finally, the reference solutions derived here can be used to understand the model predictions for strongly accelerated or decelerated Rayleigh–Taylor mixing in the large Reynolds number limit.

42 ENGINEERING↗

Post-Irradiation Evaluation of Eurofer97 Fracture Toughness Using Miniature Multinotch Bend Bar Specimens

In this study, we performed fracture toughness characterization of ten neutron-irradiated Eurofer97 variants using precracked miniature multi-notch bend bar (M4CVN) specimens based on the Master Curve method in the ASTM E1921 standard. The neutron irradiation was performed in the flux trap position of the High Flux Isotope Reactor (HFIR) of the Oak Ridge National Laboratory (ORNL) with the nominal irradiation temperature of 300°C and irradiation dose of 2.5 displacements per atom (dpa). Depending on the irradiation temperature and materials, we observed different degrees of irradiation hardening and embrittlement for ten Eurofer97 variants. The upper shift in the Master Curve reference temperature T0Q vs. the increase in Vickers microhardness values showed a liner relationship for only a few materials indicating different irradiation responses of the Eurofer97 variants.

Chen, Xiang↗