At least 1,027 records · Page 57

JAN transistor and diode characterization test program

A statistical summary of electrical characterization was performed on JAN diodes and transistors. Parameters are presented with test conditions, mean, standard deviation, lowest reading, 10% point, 90% point and highest reading.

Takeda, H.↗

Development of non-volatile semiconductor memory

A 256 word by 8-bit random access memory chip was developed utilizing p channel, metal gate metal-nitride-oxide-silicon (MNOS) technology; with operational characteristics of a 2.5 microsecond read cycle, a 6.0 microsecond write cycle, 800 milliwatts of power dissipation; and retention characteristics of 10 to the 8th power read cycles before data refresh and 5000 hours of no power retention. Design changes were implemented to reduce switching currents that caused parasitic bipolar transistors inherent in the MNOS structure to turn on. Final wafer runs exhibited acceptable yields for a die 250 mils on a side. Evaluation testing was performed on the device in order to determine the maturity of the device. A fixed gate breakdown mechanism was found when operated continuously at high temperature.

Heikkila, W. W.↗

An introduction to a unified approach to flexible rotor balancing

Two types of technique for flexible-rotor balancing are examined: the influence coefficient method, and the modal balancing method. Briefly, the influence coefficient method seeks those correction masses in a predetermined set of planes which will minimize measured vibration (readings) at a series of sensors and speeds, as predicted by influence coefficients relating vibration readings to mass additions; the influence coefficients are normally determined by a series of trial mass tests. The modal balancing method seeks to balance the rotor, one mode at a time, with a set of masses specifically selected not to disturb previously balanced lower modes, the sensitivity to this combination of masses is determined empirically by a series of trial mass tests. The two approaches are compared in supercritical-shaft balancing tests, and some common features are stressed for ultimate incorporation into a unified approach toward flexible-rotor balancing.

Parkinson, A. G.↗

Heat-pipe sensor for remote leveling

System gives level readings in inaccessible areas. Level sensor is equipped with three thermocouples used to measure temperature differences that arise when pipe is tilted. When platform on which pipe is resting is level, three thermocouple recordings are identical. When readings are unequal, platform is leveled by remote control. System can replace expensive optical equipment and can function in cold, vacuum, and hot humid environments that produce nonlinear expansion and contraction in conventional equipment. Other advantages include low cost, no moving parts, and operation in toxic environments.

Marshburn, J. P.↗

Electronic depth micrometer

Device for measuring depth or thickness reads distance of penetration by small-diameter probe. It was developed specifically to measure thickness of wet (uncured) insulation applied to Space Shuttle structures; thin probes penetrate wet insulation to substrate, and reference surface on gage is then positioned against outer surface of insulation to measure its thickness. Gage is easy to use, even by workers wearing gloves or other protective clothing, and allows remote reading and recording of production data.

Major, R. K.↗

Computer program documentation: ODRC demand plotting program user's guide

The Orbital Data Reduction Center (ODRC) Demand Plotting Program provides the user with three main options, each of which provides the additional option of generating a numerical summary and/or plots for the Measurement ID's (MID) on the Measurement Node Correlation (MNC) list. Option one reads MID data from word addressable ODRC files, stores the data on a temporary file, and uses it to build the numerical summary and/or plots, according to user input instructions. Options two and three read MID data from a word addressable ODRC file and component node data from a word addressable HSTFLO or HISTRY file. The component node data is used to calculate a predicted MID. Then, for option two, the MID and predicted MID data is used to generate a numerical summary and/or plots. For option three, the component node data itself is used in generating the numerical summary and/or plots. The numerical summary is sent to the BRKPT file, RELOCOK, and can be viewed after the execution of the program using the edit mode to find the desired section of the summary.

Damico, S. J.↗

Improvements in sparse matrix operations of NASTRAN

A "nontransmit" packing routine was added to NASTRAN to allow matrix data to be refered to directly from the input/output buffer. Use of the packing routine permits various routines for matrix handling to perform a direct reference to the input/output buffer if data addresses have once been received. The packing routine offers a buffer by buffer backspace feature for efficient backspacing in sequential access. Unlike a conventional backspacing that needs twice back record for a single read of one record (one column), this feature omits overlapping of READ operation and back record. It eliminates the necessity of writing, in decomposition of a symmetric matrix, of a portion of the matrix to its upper triangular matrix from the last to the first columns of the symmetric matrix, thus saving time for generating the upper triangular matrix. Only a lower triangular matrix must be written onto the secondary storage device, bringing 10 to 30% reduction in use of the disk space of the storage device.

Harano, S.↗

Image processing via ultrasonics - Status and promise

Acousto-electric devices for electronic imaging of light are discussed. These devices are more versatile than line scan imaging devices in current use. They have the capability of presenting the image information in a variety of modes. The image can be read out in the conventional line scan mode. It can be read out in the form of the Fourier, Hadamard, or other transform. One can take the transform along one direction of the image and line scan in the other direction, or perform other combinations of image processing functions. This is accomplished by applying the appropriate electrical input signals to the device. Since the electrical output signal of these devices can be detected in a synchronous mode, substantial noise reduction is possible

Kornreich, P. G.↗

Using 70-mm aerial photography to identify rangeland sites

A south Texas rangeland area was used as a study site to test the use of microdensitometry on 70-mm color-infrared and black-and-white photographs (scale 1:19,000) for distinguishing among 11 range sites (two brushland, seven grassland, two barren land) during the winter (February), spring (May), and summer (August) of 1976. Color-infrared photographs were also taken at a scale of 1:42,000 for the summer date. Film optical density readings were made on one color-infrared film with white light only. The best separations among density readings for all range sites were obtained using white light exposed on color-infrared film in the summer when vegetation was at peak foliage development. Results from this study indicate that 70-mm aerial color-infrared photography at a scale of 1:19,000 or 1:42,000 has good potential for identifying range sites in large and inaccessible areas, and could be a useful tool for range management.

Everitt, J. H.↗

Gage for Surface Waviness

New device gives qualitive readings of flatness, curvature, or waviness of surface. Designed to check for waviness in surface of Space Shuttle prior to installation of heat-resistant tiles, it could be used to measure regularity or irregularity of other surfaces. Irregularities are measured by noting readings of three dial indicators on simple, inexpensive instruments.

Williams, G. W.↗

EROS to universal tape conversion processor

The function of the EROS processor is to allow a user to select a specific area from a full frame LANDSAT image which is written on tape in the EROS format. The area of interest is read from the EROS formatted tape and converted to the JSC Universal format and written onto another tape. This tape can then be read by the IMDACS processing system and normal analysis can be performed.

Obrien, S. O.↗

A solid-state digital temperature recorder for space use

A solid-state, digital, temperature recorder has been developed for use in space experiments. The recorder is completely self-contained and includes a temperature sensor; all necessary electronics for signal conditioning, processing, storing, control and timing; and a battery power supply. No electrical interfacing with the particular spacecraft on which the unit is used is required. The recorder is small, light, and sturdy, and has no moving parts. It uses only biocompatible materials and has passed vibration and shock spaceflight qualification tests. The unit is capable of storing 2048, -10 to +45 C, 8-bit temperature measurements taken at intervals selectable by factors of 2 from 1.875 to 240 min; data can be retained for at least 6 months. The basic recorder can be simplified to accommodate a variety of applications by adding memory to allow more data to be recorded, by changing the front end to permit measurements other than temperature to be made, and by using different batteries to realize various operating periods. Stored flight data are read out from the recorder by means of a ground read-out unit.

Westbrook, R. M.↗

Heat Capacity Mapping Mission (HCMM) thermal surface water mapping and its correlation to LANDSAT

Graphics are presented which show HCMM mapped water-surface temperature in Lake Anna, a 13,000 dendrically-shaped lake which provides cooling for a nuclear power plant in Virginia. The HCMM digital data, produced by NASA were processed by NOAA/NESS into image and line-printer form. A LANDSAT image of the lake illustrates the relationship between MSS band 7 data and the HCMM data as processed by the NASA image processing facility which transforms the data to the same distortion-free hotline oblique Mercator projection. Spatial correlation of the two images is relatively simple by either digital or analog means and the HCMM image has a potential accuracy approaching the 80 m of the original LANDSAT data. While it is difficult to get readings that are not diluted by radiation from cooler adjacent land areas in narrow portions of the lake, digital data indicated by the line-printer display five different temperatures for open-water areas. Where the water surface response was not diluted by land areas, the temperature difference recorded by HCMM corresponds to in situ readings with rsme on the order of 1 C.

Colvocoresses, A. P.↗

An evaluation of the Intel 2920 digital signal processing integrated circuit

The circuit consists of a digital to analog converter, accumulator, read write memory and UV erasable read only memory. The circuit can convert an analog signal to a digital representation, perform mathematical operations on the digital signal and subsequently convert the digital signal to an analog output. Development software tailored for programming the 2920 is presented.

Heller, J.↗

Photographic photometry with Iris diaphragm photometers

A general method is presented for solving problems encountered in the analysis of Iris diaphragm photometer (IDP) data. The method is used to derive the general shape of the calibration curve, allowing both a more accurate fit to the IDP data for comparison stars and extrapolation to magnitude ranges for which no comparison stars are measured. The profile of starlight incident and the characteristic curve of the plate are both assumed and then used to derive the profile of the star image. An IDP reading is then determined for each star image. A procedure for correcting the effects of a nonconstant background fog level on the plate is also demonstrated. Additional applications of the method are made in the appendix to determine the relation between the radius of a photographic star image and the star's magnitude, and to predict the IDP reading of the 'point of optimum density'.

Schaefer, B. E.↗

Microdensitometry to identify saline rangelands on 70-mm color-infrared aerial film

Many of the world's rangelands are affected by salinity. The detection of these areas is important to range and resource managers who are concerned with productivity, condition, and animal carrying capacity. The reported study was conducted along a north-to-south flight line 24 km long and 1.6 wide in Starr County, TX. Everitt et al. (1977) described seven different native range sites (four nonsaline and three saline) along this flight line. The study showed that photointerpretation by microdensitometry could be used to identify saline range sites quantitatively on CIR (0.50 to 0.90 micrometers) aerial film (scales 1:19,000, 1:42,000, and 1:80,000) exposed in May 1976, June 1976, and June 1979. Microdensitometer readings made on CIR film using white or blue light generally gave the best separation between saline and nonsaline range sites. The differences in microdensitometry readings among saline and nonsaline range sites were caused by less plant cover on the saline sites.

Everitt, J. H.↗

Comparison between two Aitken counters and with cloud condensation nuclei counters at the 1980 International CCN Workshop

The Pollak and the TSI 3020 counters agreed to within about 10% at concentrations below 1000 cu cm, whereas above that concentration, substantial systematic differences were observed. When the test aerosol was monodisperse and the CCN counters were operated at supersaturations that should nucleate all the aerosol, the Pollak counter read about 6% to 20% lower than the CCN counter in the concentration range from 250/cu cm to 1800/cu cm. The TSI 3020 read about 20% lower than the CCN counter at concentrations less than 1000/cu cm, and a factor of about two higher at concentrations above 1000/cu cm.

Rogers, C. F.↗