Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROOFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Engine Installation Effects of Four Civil Transport Airplanes: Wallops Flight Facility Study

The National Aeronautics and Space Administration (NASA), Langley Research Center (LaRC), the Environmental Measurement and Modeling Division of the United States Department of Transportation s John A. Volpe National Transportation Systems Center (Volpe), and several other organizations (see Appendix A for a complete list of participating organizations and individuals) conducted a noise measurement study at NASA s Wallops Flight Facility (Wallops) near Chincoteague, Virginia during September 2000. This test was intended to determine engine installation effects on four civil transport airplanes: a Boeing 767-400, a McDonnell-Douglas DC9, a Dassault Falcon 2000, and a Beechcraft King Air. Wallops was chosen for this study because of the relatively low ambient noise of the site and the degree of control over airplane operating procedures enabled by operating over a runway closed to other uses during the test period. Measurements were conducted using a twenty microphone U-shaped array oriented perpendicular to the flight path; microphones were mounted such that ground effects were minimized and low elevation angles were observed.

Fleming, Gregg G.↗

Behind Start of Take-Off Roll Aircraft Sound Level Directivity Study - Revision 1

The National Aeronautics and Space Administration (NASA), Langley Research Center (LaRC) and the Environmental Measurement and Modeling Division of the Department of Transportation's Volpe National Transportation Systems Center (Volpe) conducted a noise measurement study to examine aircraft sound level directivity patterns behind the start-of-takeoff roll. The study was conducted at Washington Dulles International Airport (IAD) from October 4 through 20, 2004.

Lau, Michael C.↗

Theoretical and Experimental Thermal Performance Analysis of Complex Thermal Storage Membrane Containing Bio-Based Phase Change Material (PCM)

Since 2000, an ORNL research team has been testing different configurations of PCM-enhanced building envelop components to be used in residential and commercial buildings. During 2009, a novel type of thermal storage membrane was evaluated for building envelope applications. Bio-based PCM was encapsulated between two layers of heavy-duty plastic film forming a complex array of small PCM cells. Today, a large group of PCM products are packaged in such complex PCM containers or foils containing arrays of PCM pouches of different shapes and sizes. The transient characteristics of PCM-enhanced building envelope materials depend on the quality and amount of PCM, which is very often difficult to estimate because of the complex geometry of many PCM heat sinks. The only widely used small-scale analysis method used to evaluate the dynamic characteristics of PCM-enhanced building products is the differential scanning calorimeter (DSC). Unfortunately, this method requires relatively uniform, and very small, specimens of the material. However, in numerous building thermal storage applications, PCM products are not uniformly distributed across the surface area, making the results of traditional DSC measurements unrealistic for these products. In addition, most of the PCM-enhanced building products contain blends of PCM with fire retardants and chemical stabilizers. This combination of non-uniform distribution and non-homogenous composition make it nearly impossible to select a representative small specimen suitable for DSC tests. Recognizing these DSC limitations, ORNL developed a new methodology for performing dynamic heat flow analysis of complex PCM-enhanced building materials. An experimental analytical protocol to analyze the dynamic characteristics of PCM thermal storage makes use of larger specimens in a conventional heat-flow meter apparatus, and combines these experimental measurements with three-dimensional (3-D) finite-difference modeling and whole building energy simulations. Based on these dynamic tests and modeling, ORNL researchers then developed a simplified one-dimensional (1-D) model of the PCM-enhanced building component that can be easily used in whole-building simulations. This paper describes this experimental-analytical methodology as used in the analysis of an insulation assembly containing a complex array of PCM pouches. Based on the presented short example of whole building energy analysis, this paper describes step-by-step how energy simulation results can be used for optimization of PCM-enhanced building envelopes. Limited results of whole building energy simulations using the EnergyPlus program are presented as well.

25 ENERGY STORAGE↗

Dynamic Heat Flow Measurements to Study the Distribution of Phase-Change Material in an Insulation Matrix

Phase change materials (PCMs) are used in building envelopes in many forms. The PCMs may be encased in discrete pouches or containers, or they may be distributed within another medium, such as in a board or within a loose fill product. In addition, most PCM products are blends containing fire retardants and chemical stabilizers. However, the current test method to measure the dynamic characteristics of PCMs, the differential scanning calorimeter (DSC), requires specimens that are relatively uniform and very small. Considering the limitations of DSC test results when applied to more complex PCM building envelope applications, we developed a combined experimental analytical protocol to determine the amount of phase-change energy actually available to provide thermal storage. This paper presents this new methodology for performing dynamic heat flow analysis of complex PCM-enhanced building materials. The experimental analytical protocol uses a conventional heat-flow apparatus and three-dimensional (3-D), finite-difference modeling. Based upon results from this methodology, ORNL researchers developed a simplified one-dimensional (1-D) model that can be easily used in whole-building simulations. This paper describes this methodology as applied to an insulation assembly containing a complex array of PCM pouches.

25 ENERGY STORAGE↗

Analysis in Support of the Radiant Barrier Fact Sheet 2010 Update

Quantifying the benefits of radiant barriers is complex because the benefits depend upon the climate, attic geometry, duct arrangements, and other building parameters. Homeowners, however, require simplified guidance regarding building envelope options, even those options that seem to have no simple answers. An extensive parametric evaluation of radiant barrier installation alternatives was made using a newly expanded and benchmarked version of an attic simulation program. To complement this anal- ysis, a detailed numerical analysis of radiation heat transfer within the attic and within the small space bounded by the rafters and the sheathing was completed. The results provide guidance for homeowners and builders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theoretical and Experimental Thermal Performance Analysis of Building Shell Components Containing Blown Fiber Glass Insulation Enhanced with Phase Change Material (PCM)

Different types of Phase Change Materials (PCMs) have been tested as dynamic components in buildings during the last 4 decades. Most historical studies have found that PCMs enhance building energy performance. Some PCM-enhanced building materials, like PCM-gypsum boards or PCM-impregnated concretes have already found their limited applications in different countries. Today, continued improvements in building envelope technologies suggest that throughout Southern and Central US climates, residences may soon be routinely constructed with PCM in order to maximize insulation effectiveness and maintain low heating and cooling loads. The proposed paper presents experimental and numerical results from thermal performance studies. These studies focus on blown fiber glass insulation modified with a novel spray-applied microencapsulated PCM. Experimental results are reported for both laboratory-scale and full-size building elements tested in the field. In order to confirm theoretical predictions, PCM enhanced fiber glass insulation was evaluated in a guarded hot box facility to demonstrate heat flow reductions when one side of a test wall is subjected to a temperature increase. The laboratory work showed reductions in heat flow of 30% due to the presence of approximately 20 wt % PCM in the insulation. Field testing of residential attics insulated with blown fiber glass and PCM was completed in Oak Ridge, Tennessee. Experimental work was followed by detailed whole building EnergyPlus simulations in order to generate energy performance data for different US climates. In addition, a series of numerical simulations and field experiments demonstrated a potential for application of a novel PCM fiber glass insulation as enabling technology to be utilized during the attic thermal renovations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Does Mixing Make Residential Ventilation More Effective?

Ventilation dilutes or removes indoor contaminants to reduce occupant exposure. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. The total ventilation rate is the most important factor in determining the exposure of occupants to given sources, but the zone- specific distribution of exhaust and supply air, and the mixing of ventilation air can have significant roles. Different types of ventilation systems will provide different amounts of mixing depending on several factors such as air leakage through the building envelope, air distribution systems and the location of sources and occupants. This paper reports recent results of investigations to determine the impact that air mixing has on exposures of residential occupants to prototypical contaminants of concern. Evaluations of existing field measurements and simulations reported in the literature are combined with new analyses to provide an integrated overview of the topic. The results show that for extreme cases additional mixing can be a significant factor but for typical homes looking at average exposures mixing is not helpful and can even make exposures worse.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling PCM-Enhanced Insulation System and Benchmarking EnergyPlus against Controlled Field Data

Phase-change materials (PCM) used in building envelopes appear to be a promising technology to reduce energy consumption and reduce/shift peak load. However, due to complexity in modeling the dynamic behavior of PCMs, current modeling tools either lack an accurate way of predicting the performance and impact of PCMs in buildings or validation of predicted or measured performance is not available. This paper presents a model of a PCM-enhanced dynamic-insulation system in EnergyPlus (E+) and compares the simulation results against field-measured data. Laboratory tests to evaluate thermal properties and to characterize the PCM and PCM-enhanced cellulose insulation system are also presented in this paper. Results indicate that the predicted daily average heat flux through walls from the E+ simulation was within 9% of field measured data. Future analysis will allow us to predict annual energy savings from the use of PCM in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Slow Orbit Motion in the SPEAR3

SPEAR3 is a third-generation synchrotron light source storage ring. The beam stability requirements are {approx}10% of the beam size, which is about 1 micron in the vertical plane. Hydrostatic level system (HLS) measurements show that the height of the SPEAR3 tunnel floor varies by tens of microns daily. We present analysis of the HLS data, including accounting for common-mode tidal motion. We discuss the results of experiments done to determine the primary driving source of ground motion. We painted the accelerator tunnel walls white; we temporarily installed Mylar over the asphalt in the center of the accelerator; and we put Mylar over a section of the tunnel walls.

43 PARTICLE ACCELERATORS↗

WINDOW-WALL INTERFACE CORRECTION FACTORS: THERMAL MODELING OF INTEGRATED FENESTRATION AND OPAQUE ENVELOPE SYSTEMS FOR IMPROVED PREDICTION OF ENERGY USE

The boundary conditions for thermal modeling of fenestration systems assume an adiabatic condition between the fenestration system installed and the opaque envelope system. This theoretical adiabatic boundary condition may not be appropriate owing to heat transfer at the interfaces, particularly for aluminum- framed windows affixed to metal- framed walls. In such scenarios, the heat transfer at the interface may increase the discrepancy between real world thermal indices and laboratory measured or calculated indices based on NFRC Rating System.This paper discusses the development of window-wall Interface Correction Factors (ICF) to improve energy impacts of building envelope systems

99 GENERAL AND MISCELLANEOUS↗

Energy Impacts of Nonlinear Behavior of PCM When Applied into Building Envelope: Preprint

Previous research on phase change materials (PCM) for building applications has been done for several decades resulting in plenty of literature on PCM properties, temperature, and peak reduction potential. Thus, PCMs are a potential technology to reduce peak loads and HVAC energy consumption in buildings. There are few building energy simulation programs that have PCM modeling features, and evenfewer have been validated. Additionally, there is no previous research that indicates the level of accuracy when simulating PCM from a building energy simulation perspective. This study analyzes the effects a nonlinear enthalpy profile has on thermal performance and expected energy benefits for PCM-enhanced insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FEMP Focus: Spring 2010 Issue

FEMP newsletter covering energy efficiency and renewable energy strategies, tactics, and technologies to meet Federal energy management goals.

Cool Roofs↗

Technology Solutions Case Study: Cladding Attachment Over Mineral Fiber Insulation Board

Exterior insulating sheathing for high performance building enclosures is an important strategy for meeting energy efficiency requirements in many climates and can position an existing building to perform at the level of best-in-class new construction. Insulation board is also important in high performance building retrofit situations where minimal disruption at the interior is typically desired.

BSC↗

Existing Whole-House Solutions Case Study: Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. In this project, Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent).

air barrier↗

Building America Case Study: BrightBuilt Home, Modular Zero Energy, Portland, Maine

Kaplan Thompson Architects (KTA) has specialized in sustainable, energy-efficient buildings, and they have designed several custom, zero-energy homes in New England. These zero-energy projects have generally been high-end, custom homes with budgets that could accommodate advanced energy systems. In an attempt to make zero energy homes more affordable and accessible to a larger demographic, KTA explored modular construction as way to provide high-quality homes at lower costs. In mid-2013, KTA formalized this concept when they launched BrightBuilt Home (BBH). The BBH mission is to offer 'a line of architect-designed, high-performance homes that are priced to offer substantial savings off the lifetime cost of a typical home and can be delivered in less time.' For the past two years, CARB has worked with BBH and Keiser Homes (the primary modular manufacturer for BBH) to discuss challenges related to wall systems, HVAC, and quality control. In Spring of 2014, CARB and BBH began looking in detail on a home to be built in Lincolnville, Maine, by Black Bros. Builders. This report details the solution package specified for this modular plan and the challenges that arose during the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

San Jose, California: Evaluating Local Solar Energy Generation Potential (City Energy: From Data to Decisions)

This fact sheet "San Jose, California: Evaluating Local Solar Energy Generation Potential" explains how the City of San Jose used data from the U.S. Department of Energy's Cities Leading through Energy Analysis and Planning (Cities-LEAP) and the State and Local Energy Data (SLED) programs to inform its city energy planning. It is one of ten fact sheets in the "City Energy: From Data to Decisions" series.

Cities leading through energy analysis and plannin↗