Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REMOVAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

ACTINIDE REMOVAL PROCESS SAMPLE ANALYSIS, CHEMICAL MODELING, AND FILTRATION EVALUATION

Filtration within the Actinide Removal Process (ARP) currently limits the throughput in interim salt processing at the Savannah River Site. In this process, batches of salt solution with Monosodium Titanate (MST) sorbent are concentrated by crossflow filtration. The filtrate is subsequently processed to remove cesium in the Modular Caustic Side Solvent Extraction Unit (MCU) followed by disposal in saltstone grout. The concentrated MST slurry is washed and sent to the Defense Waste Processing Facility (DWPF) for vitrification. During recent ARP processing, there has been a degradation of filter performance manifested as the inability to maintain high filtrate flux throughout a multi-batch cycle. The objectives of this effort were to characterize the feed streams, to determine if solids (in addition to MST) are precipitating and causing the degraded performance of the filters, and to assess the particle size and rheological data to address potential filtration impacts. Equilibrium modelling with OLI Analyzer{sup TM} and OLI ESP{sup TM} was performed to determine chemical components at risk of precipitation and to simulate the ARP process. The performance of ARP filtration was evaluated to review potential causes of the observed filter behavior. Task activities for this study included extensive physical and chemical analysis of samples from the Late Wash Pump Tank (LWPT) and the Late Wash Hold Tank (LWHT) within ARP as well as samples of the tank farm feed from Tank 49H. The samples from the LWPT and LWHT were obtained from several stages of processing of Salt Batch 6D, Cycle 6, Batch 16.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Actinide Removal Process October 2014 Sample Analysis

Filtration within the Actinide Removal Process (ARP) currently limits the throughput in interim salt processing at the Savannah River Site. In this process, batches of salt solution with Monosodium Titanate (MST) sorbent are concentrated by crossflow filtration. The filtrate is subsequently processed to remove cesium in the Modular Caustic Side Solvent Extraction Unit (MCU) followed by disposal in saltstone grout. The concentrated MST slurry is washed and sent to the Defense Waste Processing Facility (DWPF) for vitrification. During past ARP processing, there has been a degradation of filter performance manifested as the inability to maintain high filtrate flux throughout a multi-batch cycles during Salt Batches 6, 5 and 4. The objectives of the current effort for Salt Batch 7 samples, which are similar to the most recent ARP sample analysis from 2013, were to characterize the feed streams, to determine if solids (in addition to MST) are precipitating and causing the degraded performance of the filters, and to assess the particle size and rheological data to address potential filtration impacts. The samples from the LWPT and LWHT were obtained from several stages of processing of Salt Batch 7B, Cycle 1, Batch 67.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Report for the ½ Scale Air-Cooled RCCS Tests in the Natural convection Shutdown heat removal Test Facility (NSTF)

The Natural convection Shutdown heat removal Test Facility (NSTF) is a large scale thermal hydraulics test facility that has been built at Argonne National Laboratory (ANL). The facility was constructed in order to carry out highly instrumented experiments that can be used to validate the performance of passive safety systems for advanced reactor designs. The facility has principally been designed for testing of Reactor Cavity Cooling System (RCCS) concepts that rely on natural convection cooling for either air or water-based systems. Standing 25-m in height, the facility is able to supply up to 220 kW at 21 kW/m 2 to accurately simulate the heat fluxes at the walls of a reactor pressure vessel. A suite of nearly 400 data acquisition channels, including a sophisticated fiber optic system for high density temperature measurements, guides test operations and provides data to support scaling analysis and modeling efforts. Measurements of system mass flow rate, air and surface temperatures, heat flux, humidity, and pressure differentials, among others; are part of this total generated data set. The following report provides an introduction to the top level-objectives of the program related to passively safe decay heat removal, a detailed description of the engineering specifications, design features, and dimensions of the test facility at Argonne. Specifications of the sensors and their placement on the test facility will be provided, along with a complete channel listing of the data acquisition system.

42 ENGINEERING↗

Characterization of Solid Materials Responsible for the Partial Blockage of the 3H Evaporator-to-Mercury Removal Tank Drain Line

In April 2015, part of the solid wet cake material responsible for partially obstructing of the drain line from the Mercury Removal Tank (MRT) on the 3H Evaporator was delivered to SRNL for analysis. The desired analytical goal was to identify the chemical components of the material responsible for the partial blockage and if possible, infer possible formation mechanisms and the best way of removing the consolidated clogging solid material from the drain line.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Solids Deposited on the Modular Caustic-Side Solvent Extraction Unit (MCU) Strip Effluent (SE) Coalescer Media Removed in April 2015

On June 2015, Savannah River National Laboratory (SRNL) received a Strip Effluent (SE) coalescer (FLT-304) from MCU. That coalescer was first installed at MCU in late October 2014 and removed in April 2015. While processing approximately 48,700 gallons of strip solution, the pressure drop steadily increased linearly from 1 psi to near 16 psi (the administrative limit is 17 psi) with the total filtrate volume (2.1E-4 psi/gal of filtrate). The linear behavior is due to the combined effect of a constant deposition of material that starts from the closed-end to the mid-section of the coalescer reducing the available surface area of the coalescer for fluid passage (linearly with filtrate volume) and the formation of a secondary emulsion (water in NG-CSSX) on the fibers of the coalescer media. Both effects reduced the coalescer porosity by at least 13% (after processing 48,700 gallons). Before the coalescer was removed, it was flushed with a 10 mM boric acid solution to reduce the dose level. To determine the nature of the deposited material, a physical and chemical analysis of the coalescer was conducted. Characterization of this coalescer revealed the adsorption of organic containing amines (secondary amides and primary amines), TiDG, degraded modifier (with no hydroxyl group), MaxCalix, and oxidized hydrocarbon (possibly from Isopar™L or from lubricant used at MCU) onto the coalescer media. The amide and amines are possibly from the decomposition of the suppressor (TiDG). The modifier and MaxCalix were the largest components of the deposited organic material, as determined from leaching the coalescer with dichloromethane. Both the Fourier-Transformed Infrared (FTIR) and Fourier-Transformed Hydrogen Nuclear Magnetic Resonance (FT-HNMR) results indicated that some of the modifier was degraded (missing their OH groups). The modifier was observed everywhere in the examined coalescer pieces (FTIR), while the TiDG and its decomposition products were observed at the entrance discs of the coalescer. A solvent trim (a cocktail of solvent components with a high concentration of modifier) was added to the solvent on 2/22/2015. It is believed that the trim did not mix completely with the solvent and that it was subsequently spread around the MCU components including the coalescers, where it may have deposited. Chronologically, the modifier, the TiDG’s decomposition products and silicates deposited on the entrance discs first and after the pressure drop increased significantly, parts of the coalescer media detached itself from the central porous steel mandrel and a significant amount of steel debris, mercury, titanium, and additional aluminum and silicates deposited on the coalescer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial, extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Milestone Report - M4FT-17OR030107025 - Design of a tritium and iodine removal system for use with advanced TPOG

US regulations will require the removal of iodine and tritium, along with other volatile and semi-volatile radionuclides, from the off-gas streams of nuclear fuel reprocessing plants. Advanced tritium pretreatment (TPT) is an additional head-end operation that could be incorporated within nuclear fuel reprocessing plants. It utilizes nitrogen dioxide (NOR2R) as an oxidant to convert UOR2R to UR3ROR8R prior to traditional aqueous dissolution. Advanced TPT can result in the quantitative volatilization of both tritium and iodine. Up-front removal of iodine is of significant advantage because otherwise it distributes to several unit operations and the associated off-gas streams. The off-gas streams will then require treatment to comply with US regulations. Advanced TPT is currently under development at Oak Ridge National Laboratory, and a kilogram-scale hot cell demonstration with used nuclear fuel (UNF) is planned for fiscal year (FY) 2018.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Removal of Dissolved Silica using Calcinated Hydrotalcite in Real-life Applications.

Water shortages are a growing global problem. Reclamation of industrial and municipal wastewater will be necessary in order to mitigate water scarcity. However, many operational challenges, such as silica scaling, prevent large scale water reuse. Previously, our team at Sandia has demonstrated the use of selective ion exchange materials, such as calcinated hydrotalcite (HTC, (Mg 6 Al 2 (OH) 16 (CO 3 )*4H 2 O)), for the low cost removal of silica from synthetic cooling tower water. However, it is not currently know if calcinated HTC has similar capabilities in realistic applications. The purpose of this study was to investigate the ability of calcinated HTC to remove silica from real cooling tower water. This was investigated under both batch and continuous conditions, and in the presence of competing ions. It was determined that calcinated HTC behaved similarly in real and synthetic cooling tower water; the HTC is highly selective for the silica even in the presence of competing cations. Therefore, the data concludes that calcinated HTC is a viable anti-scaling pretreatment for the reuse of industrial wastewaters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvements in iodine and ruthenium removal from advanced liquid processing system

SRNL has considerable experience in designing, engineering, and operating systems for removing iodine-129 (I-129) and ruthenium-106 (Ru-106) from waste streams that are directly analogous to the Advanced Liquid Processing System (ALPS) waste streams. SRNL proposes to provide the technical background and design and engineering support for an improved I-129 and Ru-106 removal system for application to ALPS on the Fukushima Daiichi Nuclear Power Station (NPS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soil Gas Sample Handling: Evaluation of Water Removal and Sample Ganging

Soil gas sampling is currently conducted in support of Nuclear Test Ban treaty verification. Soil gas samples are collected and analyzed for isotopes of interest. Some issues that can impact sampling and analysis of these samples are excess moisture and sample processing time. Here we discuss three potential improvements to the current sampling protocol; a desiccant for water removal, use of molecular sieve to remove CO 2 from the sample during collection, and a ganging manifold to allow composite analysis of multiple samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test Report for Cesium and Solids Removal from an 11.5L Composite of Archived Hanford Double Shell Tank Supernate for Off-Site Disposal

The 222-S Laboratory blended supernate waste from Hanford Tanks 241-AN-101, 241-AN- 106, 241-AP-105, 241-AP-106, 241-AP-107, and 241-AY-101 from the hot cell archive to create a bulk composite. The composite was blended with 600 mL 19.4 M NaOH, which brought the total volume to approximately 11.5 L (3 gal). The composite was filtered to remove solids and passed through spherical resorcinol-formaldehyde ion-exchange resin columns to remove cesium. The composite masses were tracked as a treatability study. Samples collected before, during, and after the ion-exchange process were characterized for a full suite of analytes (inorganic, organic, and radionuclides) to aid in the classification of the waste for shipping, receiving, treatment, and disposal determinations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test Report for Cesium and Solids Removal from an 11.5L Composite of Archived Hanford Double Shell Tank Supernate for Off-Site Disposal.

The 222-S Laboratory blended supernate waste from Hanford Tanks 241-AN-101, 241-AN- 106, 241-AP-105, 241-AP-106, 241-AP-107, and 241-AY-101 from the hot cell archive to create a bulk composite. The composite was blended with 600 mL 19.4 M NaOH, which brought the total volume to approximately 11.5 L (3 gal). The composite was filtered to remove solids and passed through spherical resorcinol-formaldehyde ion-exchange resin columns to remove cesium. The composite masses were tracked as a treatability study. Samples collected before, during, and after the ion exchange process were characterized for a full suite of analytes (inorganic, organic, and radionuclides) to aid in the classification of the waste for shipping, receiving, treatment, and disposal determinations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxyhydroxides on aluminum spent nuclear fuel: formation studies and removal practices to prevent radiolytic gas production

Aluminum-clad nuclear fuel has been at the forefront in research and commercial reactors. After being removed from the reactor, the spent nuclear fuel is placed in large-volume water basins (wet storage) that are constantly monitored for water quality to minimize corrosion/deterioration. The water provides both radiation shielding and cooling for the freshly removed fuel. It is highly desired to have a pathway for fuel to be transitioned to dry storage in sealed casks, so that spent nuclear fuel can be safely transported and dispositioned in a permanent repository, and basin capacity can be made available for temporary wet storage of fresher spent fuel. A challenge for safe, road-ready dry storage is the hydrated aluminum oxides (oxyhydroxides) that are prevalent on aluminum spent nuclear fuel that has been stored under water for years. If water is released from the oxyhydroxides during dry storage, it can create corrosion within the storage canister, and hydrogen can be generated through radiolysis of the oxyhydroxides, causing pressurization and flammability risks. The focus of this project is to develop knowledge of the oxyhydroxide growth and production of gases through radiolysis and to apply empirical models for predicting these phenomena. The expertise developed will be used to formulate conditions and parameters for oxyhydroxide removal/dehydration from fuel cladding through vacuum or forced-air gas drying, to prevent problems during permanent dry storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Inspection and Test Report for the Removed 241-C-107 Dome Concrete.

This report presents the results of the examination and testing of the 55 inch diameter concrete dome 'Plug' removed from SST 241-C-107. Photographs and discussion of field inspection of the dome 'Plug' cross section are provided. Fourteen concrete cores removed from the dome 'Plug' were sent offsite for testing. Twelve cores were subject to transverse frequency, elastic modulus, Poisson's ratio, and compression testing. Two cores were subjected to petrographic examination. This report documents represents further implementation of the Single Shell Tank Integrity Project Expert Panel recommendation, SI-5, Test Dome Concrete and Rebar 'Plugs'.

36 MATERIALS SCIENCE↗

A Model of Airborne Particle Removal by a Liquid Drop Spray

The removal of airborne particles by liquid drops is an important atmospheric and industrial process. In the atmospheric science literature, it is variously referred to as “precipitation scavenging,” “wet deposition,” or “ rain out” and has been extensively studied for its role in the formation of clouds and the removal of atmospheric pollutants (Pruppacher et al. 1983; Slinn 1984; Pruppacher and Klett 2010).

42 ENGINEERING↗

Evaluation of Alternate Impurity Removal Getters - Year 2

The Savannah River Site Tritium Facilities use various getter materials (SAES® ST909 and ST198) as part of the tritium process stripper (TPS) for the removal of impurity species. Benefits of ST909 are found in both environmental stewardship and gas processing improvements. The tritium capturing performance of ST198 is affected by impurities such as ammonia and carbon monoxide. SAES ST198 is used as a final polisher to remove trace amounts of tritium in the process stream before discharge through the stack. ST909 decomposes impurities such as tritiated water, methane, and ammonia. Therefore the upstream material, ST909, is important to environmental safety. ST909 also provides the benefit of capturing oxygen and carbon oxides.

36 MATERIALS SCIENCE↗

Preliminary Evaluation of Removing Used Nuclear Fuel From Nine Shutdown Sites

The Blue Ribbon Commission on America's Nuclear Future identified removal of stranded used nuclear fuel at shutdown sites as a priority so that these sites may be completely decommissioned and put to other beneficial uses (BRC 2012). In this report, a preliminary evaluation of removing used nuclear fuel from nine shutdown sites was conducted. The shutdown sites included Maine Yankee, Yankee Rowe, Connecticut Yankee, Humboldt Bay, Big Rock Point, Rancho Seco, Trojan, La Crosse, and Zion. At these sites a total of 7649 used nuclear fuel assemblies and a total of 2813.2 metric tons heavy metal (MTHM) of used nuclear fuel are contained in 248 storage canisters. In addition, 11 canisters containing greater-than-Class C (GTCC) low-level radioactive waste are stored at these sites.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Highly Efficient Non-Oxidative Methane Conversion with Continuous Hydrogen Removal

A non-oxidative methane conversion catalytic system has been successfully developed. Ball-milling and annealing above 1973 K are necessary in order to synthesize the unique methane activation catalyst. Characterization and evaluation of catalysts shows that the surface area should be carefully controlled to minimize coke deposition. The influence of temperature, pressure, space velocity and hydrogen concentration on catalytic process was systematically studied. The reaction conditions were optimized to a combination of 1323 K, ambient pressure and a space velocity of 4900 ml/g·h. A process, using 0.5% Fe/SiO 2 catalyst under these conditions, yield a methane conversion of 15.62%, with product distribution of 40.05% C 2 , 26.48% BTX and 10.7% naphthalene and demonstrated stable operation of at least 50 hours. This result meets the milestone in the phase I proposal. A non-oxidative methane catalyst-integrated SOFC reactor was accomplished, using nickel-free cells of both ScSZ oxygen-ion conductor and BZY proton conductor. With in-situ hydrogen removal enabled by SOFC, hydrogen concentration in the reactor was effectively reduced, shifting reaction equilibrium and boosting methane conversion. However, due to the high temperature requirement of this reaction, most available proton-conducting SOFCs become oxygen-ion conducting, leading to side reactions and counteracting the benefits from hydrogen removal. To take advantage of the enhanced oxygen-ion conductance of SOFC at high temperatures, we have also paired the nickel-free SOFCs with high-performance oxidative coupling of methane (OCM) catalysts. The SOFC-OCM tubular membrane reactor, employing a Mn-Ce-Na 2 WO 4 /SiO 2 -based catalyst, demonstrates a remarkable performance of 60.7% methane conversion with 41.6% C 2 + selectivity, 5.8 ethylene-to-ethane ratio and 19.4% ethylene yield. The use of integrated SOFC-OCM reactor enables better hydrocarbon selectivity and higher ethylene-to-ethane ratio, eliminating the need of an expensive air separation unit and preventing the direct co-feed of explosive methane-oxygen mixture. We believe this presents a great promise towards commercialization as an advanced methane conversion technology.

02 PETROLEUM↗