Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Thermoelastic cooling

A cooling system based on thermoelastic effect is provided. The system comprises a heat sink, a refrigerated space and a regenerator coupled to the refrigerated space and to the heat sink to pump heat from the refrigerated space to the heat sink. The regenerator comprises solid thermoelastic refrigerant materials capable of absorbing or releasing heat.

42 ENGINEERING↗

Adsorption cooling system using metal organic frameworks

An adsorptive cooling system includes: a first highly adsorptive structure positioned to receive thermal energy from a thermal energy source, including: a first substrate; and a first metal-organic framework (MOF) coupled to the first substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions; a second highly adsorptive structure positioned to receive thermal energy from the thermal energy source including: a second substrate; and a second MOF coupled to the second substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions; a cooling unit; and a circulation system adapted for circulating refrigerant from the first highly adsorptive structure and the second highly adsorptive structure to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant to at least one of the first highly adsorptive structure and the second highly adsorptive structure.

Baumann, Theodore F.↗

Enhanced Integer Permutation based Genetic Algorithm for Optimization of Tube-Fin Heat Exchanger Circuitry with Splits and Merges

Tube-fin heat exchangers (HXs) are widely used in air-conditioning and heat pump applications. The performance of these heat exchangers is strongly influenced by the refrigerant circuitry. Studies have proved that by optimizing the refrigerant circuitry, the performance of HXs can be significantly improved. In our previous research, an Integer Permutation based Genetic Algorithm (IPGA) was developed to obtain the optimal circuitry designs. Our previous research showed that IPGA demonstrates superior capability to obtain better refrigerant circuitries with lower computational cost than the other methods in literature. And the optimal circuitry designs obtained from IPGA are manufacturable with the available tooling. However, the IPGA developed previously cannot generate designs with splitting and merging of circuits. To remedy this limitation, a new chromosome which can represent circuitry with splitting and merging of circuits is developed. In addition to the six genetic operators implemented previously, two new genetic operators are developed to generate splits and merges. As a result, the enhanced IPGA can explore the solution space more thoroughly than the previous IPGA. A case study using an evaporator from an A-type indoor unit shows that, given the similar capacity improvements obtained from the enhanced IPGA compared with the previous IPGA, the refrigerant pressure drop reduction obtained from the enhanced IPGA is 26.5% compared against 1.0% pressure drop reduction from the previous IPGA. The benchmark of the enhanced IPGA with other methods in literature demonstrates that the enhanced IPGA can generate circuitry designs with performance superior to those obtained from other methods.

LI, Zhenning↗

Critical Analysis of Replacements for R-410A in Heat Pump Applications

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Research has shown that using heat exchangers with small diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants due to reduced refrigerant charge, reduced flammable impact and environmental impact. However, application of small diameter tube requires in-depth component design optimization to make the new system adapt to low-GWP refrigerants.In this paper, multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm on a R-410A residential 5-ton air source heat pump is performed for improved system performance and reduced material cost. Five R-410A alternatives, i.e., R-32, R-454A, R-454B, R-454C and R-455A are investigated. R-455A and R-454C have GWP lower than 150. As a result of optimization, 12.4%-19.1% Energy Efficiency Ratio (EER) improvement and up to 71% HXs material cost saving is achieved. Life Cycle Climate Performance (LCCP) analysis shows that optimized systems reduce total CO2 emission by 13%-33% depending on the choice of refrigerant and climate zone.The optimal heat exchangers resulting from this research can fit into the original R-410A fan-coil units. The proposed heat pump design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Optimization Strategies for Single-Stage, Multi-Stage and Continuous ADRs

Adiabatic Demagnetization Refrigerators (ADR) have many advantages that are prompting a resurgence in their use in spaceflight and laboratory applications. They are solid-state coolers capable of very high efficiency and very wide operating range. However, their low energy storage density translates to larger mass for a given cooling capacity than is possible with other refrigeration techniques. The interplay between refrigerant mass and other parameters such as magnetic field and heat transfer points in multi-stage ADRs gives rise to a wide parameter space for optimization. This paper first presents optimization strategies for single ADR stages, focusing primarily on obtaining the largest cooling capacity per stage mass, then discusses the optimization of multi-stage and continuous ADRs in the context of the coordinated heat transfer that must occur between stages. The goal for the latter is usually to obtain the largest cooling power per mass or volume, but there can also be many secondary objectives, such as limiting instantaneous heat rejection rates and producing intermediate temperatures for cooling of other instrument components.

sub-kelvin cooling↗

Large room-temperature elastocaloric effect in a bulk polycrystalline Ni-Ti-Cu-Co alloy with low isothermal stress hysteresis

Creation of high-performance advanced elastocaloric materials is essential for the execution of elastocaloric refrigeration that can be an environment-friendly and high-efficiency substitute for the widely used traditional vapor-compression cooling technology. Here we have developed a bulk polycrystalline Ni-Ti-Cu-Co shape memory alloy exhibiting large elastocaloric effect, low stress hysteresis and room temperature working temperature, all of which are of great importance to and urgently demanded for high-efficiency room-temperature elastocaloric refrigeration. This newly developed (Ni 42.5 Ti 50 Cu 7.5 ) 99 Co 1 alloy shows a large room-temperature elastocaloric effect with directly measured adiabatic temperature change up to -14.4 K during unloading. The stress hysteresis of the isothermal superelastic stress-strain curve is as low as 60 MPa when the maximum tensile strain is 2.7%. Owing to the large elastocaloric effect and low stress hysteresis, a very high coefficient of performance up to 19 is achieved on the material level. This newly developed (Ni 42.5 Ti 50 Cu 7.5 ) 99 Co 1 alloy is a robust candidate for efficient elastocaloric refrigeration. Advanced in-situ synchrotron high-energy X-ray diffraction technique was employed to reveal the phase transformation sequence and to accurately determine the crystal structure of different phases, based on which the lattice compatibility between the transforming phases was evaluated and the phase transformation strain was predicted, providing in-depth fundamental understanding of the martensitic transformation in this newly developed alloy. This work could be useful for designing high-performance elastocaloric materials for solid-state cooling applications.

36 MATERIALS SCIENCE↗

Development of a near-isothermal transcritical CO 2 compression system with a liquid piston compressor

Compressors are critical components in vapor compression cycle systems, significantly contributing to energy consumption. As global demand for HVAC&R systems rises, enhancing compressor efficiency becomes increasingly vital. This paper introduces a novel liquid piston compressor integrated with a gas cooler for the transcritical CO 2 refrigeration cycle. The liquid piston enables CO 2 refrigerant compression within various types of heat exchangers, facilitating the transfer of compression heat to the heat transfer fluid. By releasing significant heat, this compressor allows for removing or downsizing the traditional gas cooler in the refrigeration system. This paper presents the experimental performance of the first near-isothermal compressor utilizing a liquid piston in a vapor compression cycle. The critical parameters affecting heat transfer are analyzed by using a 1-D simulation model to achieve a near-isothermal compression process. The results show that the developed prototype successfully reduced the compression temperature increase from 95 K to 10 K, achieving 90 % isothermal efficiency. Furthermore, the 1-D simulation results suggest the smaller internal diameter tubes benefit the isothermal efficiency the most.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trends in best-in-class energy-efficient technologies for room air conditioners

Improving the efficiency of room air conditioners (RACs) could provide significant energy and associated emissions savings, particularly in emerging economies with hot climates where the cooling demand is expected to increase dramatically. To help accelerate efficiency improvements, this study identifies “best-in-class” high-efficiency RAC components and products. The findings show that manufacturers tend to minimize manufacturing costs by using RAC designs that are readily available or standardized to their production, and they share components across various models. High-efficiency RAC models use advanced compressor technologies optimized at a low frequency, large heat exchangers with thermodynamically effective materials and designs, highly efficient direct current fan motors, advanced metering devices, and smart sensors for temperature and humidity control. Recently RAC manufacturers have been improving seasonal efficiency – better reflecting part-load operation – especially via variable-speed (inverter) drives for compressor motors. Recent highest-efficiency RAC models use low global warming potential (GWP) refrigerants, having transitioned from conventional high-GWP refrigerants, in regions where RACs that use these low-GWP refrigerants are commercially available. Recently demonstrated innovative technologies show trends toward smart hybrid designs, evaporative cooling, and solid-state materials beyond the conventional vapor-compression technology. This information could help policymakers improve their RAC market-transformation programs to align with the most-efficient global technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flow boiling heat transfer study of R-134a/R-290/R-600a mixture in 9.52 and 12.7 mm smooth horizontal tubes: Experimental investigation

A detailed experimental investigation is carried out to study the flow boiling heat transfer behavior of R-134a/R-290/R-600a (91%/4.068%/4.932% by mass) refrigerant mixture in smooth horizontal tubes of diameter 9.52 and 12.7 mm. The heat transfer coefficients of the mixture are experimentally measured under varied heat flux conditions for stratified flow patterns using a coaxial counter-current heat exchanger test section. The tests are conducted for refrigerant inlet temperatures between -9 and 5 C and mass flow rates ranging from 3 to 5 g s{sup -1}. Kattan-Thome-Favrat maps are used to confirm the flow patterns for the tested conditions. The magnitude of the heat transfer coefficient with respect to flow patterns and different mechanisms of boiling are discussed. The heat transfer coefficient of the refrigerant mixture is also compared with that of R-134a for selected working conditions. The significance of nucleate boiling in the overall heat transfer process under these testing conditions is highlighted. (author)

42 ENGINEERING↗

Evaporation heat transfer and friction characteristics of R-134a flowing downward in a vertical corrugated tube

Differently from most previous studies, the heat transfer and friction characteristics of the pure refrigerant HFC-134a during evaporation inside a vertical corrugated tube are experimentally investigated. The double tube test sections are 0.5 m long with refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tubes are one smooth tube and two corrugated tubes, which are constructed from smooth copper tube of 8.7 mm inner diameter. The test runs are performed at evaporating temperatures of 10, 15, and 20 C, heat fluxes of 20, 25, and 30 kW/m{sup 2}, and mass fluxes of 200, 300, and 400 kg/m{sup 2} s. The quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The pressure drop across the test section is measured directly by a differential pressure transducer. The effects of heat flux, mass flux, and evaporation temperature on the heat transfer coefficient and two-phase friction factor are also discussed. It is found that the percentage increases of the heat transfer coefficient and the two-phase friction factor of the corrugated tubes compared with those of the smooth tube are approximately 0-10% and 70-140%, respectively. (author)

42 ENGINEERING↗

Performance optimization of CO 2 heat pump water heater

A preliminary analysis was conducted to analyze the performance of a heat pump water heater (HPWH) that uses CO 2 as the refrigerant. A model to predict the performance was developed and calibrated based on the experimental data for an existing HPWH using a CO 2 refrigerant. The calibrated model was then used to run a parametric analysis in which factors such as water supply temperature, water circulation rate, tank stratification, and condenser configuration were considered. The performance of a commercial CO 2 system was compared with that of a similar system using R-134a as the refrigerant. It was found that CO 2 HPWH performance was comparable to that of an R-134a HPWH, more so for a separated gas cooler configuration. For comparable performance, the compressor size and the tube-in-tube heat exchanger (condenser/gas cooler) size were compared for CO 2 - and R-134a-based systems. Finally, the impact of the water circulation rate on the water temperature stratification in the tank, an essential requirement for higher performance for CO 2 HPWH systems was also investigated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Enhanced pool boiling heat transfer using novel inverted trapezoid microgroove structures

Pool boiling heat transfer improvements with enhanced surfaces have been extensively studied for various hydrofluorocarbon (HFC) refrigerants. However, there is a limited number of studies in the open literature that focus on the pool boiling heat transfer characteristics of hydrofluoroolefin (HFO) refrigerants on enhanced surfaces. This study aims to address this gap by analyzing the pool boiling behavior of HFO refrigerants, specifically R1234yf and R1234ze(E). Experiments were conducted on both plain surfaces and novel inverted trapezoid microgroove structures. Further, the experimental results indicate that the microgroove structures can improve heat transfer coefficients by up to 80% compared to plain surfaces. Additionally, the performance of R1234yf and R1234ze(E) was compared to that of R134. It was observed that R1234yf exhibited comparable performance to R134a, while R1234ze(E) showed slightly lower performance. To assess the influence of saturation temperature on pool boiling heat transfer, tests were conducted at different saturation temperatures of 15℃, 25℃, and 35℃. The findings revealed that the pool boiling heat transfer coefficient increases with rising saturation temperature.

42 ENGINEERING↗

Toward Polarization-Switched Molecular Pumps

Pumping of fluids is universally performed by using mechanical or thermal compressors. We demonstrate for the first time a new solid-state molecular pumping mechanism induced by switching the adsorption affinity for a gas through polarization of a chromophore under an applied electric field. Mass spectrometry was used to trace refrigerant gas (difluoromethane) uptake on a chromophore-coated capacitor under applied voltage and subsequent desorption when the voltage and electrode polarization was removed showing an exchange capacity of 0.11 mol of refrigerant per liter of chromophore. Calorimetry confirmed a reversible enthalpy change of 9 Kcal/mol in the polarization-induced sorption-desorption process. Here, the present work establishes the principle and feasibility of non-mechanical molecular pumping, which can be exploited for refrigeration, catalysis, gas separation, among many other potential applications.

42 ENGINEERING↗

THE CRYOPLANT FOR THE ITER NEUTRAL BEAM TEST FACILITY TO BE BUILT AT RFX IN PADOVA, ITALY

The Neutral Beam Test Facility (NBTF), planned to be constructed in Padua (Italy), will constitute the prototype of the two Neutral Beam Injectors (NBI), which will be installed in the ITER plant (Cadarache-France). The NBTF is composed of a 1 MV accelerator that can produce a 40 A deuteron pulsed neutral beam particles. The necessary vacuum needed in the accelerator is achieved by two large cryopumps, designed by FZK-Karlsruhe, with radiation shields cooled between 65 K and 90 K and with cryopanels cooled by 4 bar supercritical helium (ScHe) between 4.5 K and 6.5 K. A new cryoplant facility will be installed with two large helium refrigerators: a Shield Refrigerator (SR), whose cooling capacity is up to 30 kW between 65 K and 90 K, and a helium Main Refrigerator (MR), whose equivalent cooling capacity is up to 800 W at 4.5 K. The cooling of the cryopanels is obtained with two (ScHe) 30 g/s pumps (one redundant), working in a closed cycle around 4 bar producing a pressure head of 100 mbar. Two heat exchangers are immersed in a buffer dewar connected to the MR. The MR and SR different operation modes are described in the paper, as well as the new cryoplant installation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Options for Cryogenic Load Cooling with Forced Flow Helium Circulation

Cryogenic pumps designed to circulate super-critical helium are commonly deemed necessary in many super-conducting magnet and other cooling applications. Acknowledging that these pumps are often located at the coldest temperature levels, their use introduces risks associated with the reliability of additional rotating machinery and an additional load on the refrigeration system. However, as it has been successfully demonstrated, this objective can be accomplished without using these pumps by the refrigeration system, resulting in lower system input power and improved reliability to the overall cryogenic system operations. In this paper we examine some trade-offs between using these pumps vs. using the refrigeration system directly with examples of processes that have used these concepts successfully and eliminated using such pumps

36 MATERIALS SCIENCE↗

Towards tailoring the magnetocaloric response in FeRh-based ternary compounds

In this work, we demonstrate that the magnetocaloric response of FeRh-based compounds may be tailored for potential magnetic refrigeration applications by chemical modification of the FeRh lattice. Alloys of composition Fe(Rh{sub 1−x}A{sub x}) or (Fe{sub 1−x}B{sub x})Rh (A = Cu, Pd; B = Ni; 0 < x < 0.06) were synthesized via arc-melting and subsequent annealing in vacuum at 1000 °C for 48 h. The magnetocaloric properties of the FeRh-based systems were determined using isothermal M(H) curves measured in the vicinity of the magnetostructural temperature (T{sub t}). It is found that the FeRh working temperature range (δT{sub FWHM}) may be chemically tuned over a wide temperature range, 100 K ≤ T ≤ 400 K. While elemental substitution consistently decreases the magnetic entropy change (ΔS{sub mag}) of the FeRh-based ternary alloys from that of the parent FeRh compound (ΔS{sub mag},{sub FeRh} ∼ 17 J/kg K; ΔS{sub mag,FeRh-ternary =} 7–14 J/kg K at H{sub app} = 2 T), the net refrigeration capacity (RC), defined as the amount of heat that can be transferred during one magnetic refrigeration cycle, of the modified systems is significantly higher (RC{sub FeRh} ∼ 150 J/kg; RC{sub FeRh-ternary =} 170–210 J/kg at H{sub app} = 2 T). These results are attributed to stoichiometry-induced changes in the FeRh electronic band structure and beneficial broadening of the magnetostructural transition due to local chemical disorder.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗