Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Using personal monitoring data to derive organ doses for medical radiation workers in the Million Person Study—considerations regarding NCRP Commentary no. 30

The study of low dose and low-dose rate exposure is of central importance in understanding the possible range of health effects from prolonged exposures to radiation. The One Million Person Study of Radiation Workers and Veterans (MPS) of low-dose health effects was designed to evaluate radiation risks among healthy American workers and veterans. The MPS is evaluating low-dose and dose-rate effects, intakes of radioactive elements, cancer and non-cancer outcomes, as well as differences in risks between women and men. Medical radiation workers make up a large group of individuals occupationally exposed to low doses of radiation from external x-ray/gamma exposures. For the MPS, about 100 000 United States medical radiation workers have been selected for study. The approach to the complex dosimetry circumstances for such workers over three to four decades of occupation were initially and broadly described in National Council on Radiation Protection and Measurements (NCRP) Report No. 178. NCRP Commentary No. 30 provides more detail and describes an optimum approach for using personal monitoring data to estimate lung and other organ doses applicable to the cohort and provides specific precautions/considerations applicable to the dosimetry of medical radiation worker organ doses for use in epidemiologic studies. The use of protective aprons creates dosimetric complexity. It is recommended that dose values from dosimeters worn over a protective apron be reduced by a factor of 20 for estimating mean organ doses to tissues located in the torso and that 15% of the marrow should be assumed to remain unshielded for exposure scenarios when aprons are worn. Conversion coefficients relating personal dose equivalent, H p (10) in mSv, to mean absorbed doses to organs and tissues, D T in mGy, for females and males for six exposure scenarios have been determined and presented for use in the MPS. This Memorandum summarises several key points in NCRP Commentary No. 30.

Environmental Sciences & Ecology↗

Using AI for Management of Field Emission in SRF Linacs

Field emission control, mitigation, and reduction is critical for reliable operation of high gradient superconducting radio-frequency (SRF) accelerators. With the SRF cavities at high gradients, the field emission of electrons from cavity walls can occur and will impact the operational gradient, radiological environment via activated components, and reliability of CEBAF’s two linacs. A new effort has started to minimize field emission in the CEBAF linacs by re-distributing cavity gradients. To measure radiation levels, newly designed neutron and gamma radiation dose rate monitors have been installed in both linacs. Artificial intelligence (AI) techniques will be used to identify cavities with high levels of field emission based on control system data such as radiation levels, cryogenic readbacks, and vacuum loads. The gradients on the most offending cavities will be reduced and compensated for by increasing the gradients on least offensive cavities. Training data will be collected during this year’s operational program and initial implementation of AI models will be deployed. Preliminary results and future plans are presented.

Carpenter, Adam↗

Using AI for Management of Field Emission in SRF Linacs

Field emission control, mitigation, and reduction is critical for reliable operation of high gradient superconducting radio-frequency (SRF) accelerators. With the SRF cavities at high gradients, the field emission of electrons from cavity walls can occur and will impact the operational gradient, radiological environment via activated components, and reliability of CEBAF’s two linacs. A new effort has started to minimize field emission in the CEBAF linacs by re-distributing cavity gradients. To measure radiation levels, newly designed neutron and gamma radiation dose rate monitors have been installed in both linacs. Artificial intelligence (AI) techniques will be used to identify cavities with high levels of field emission based on control system data such as radiation levels, cryogenic readbacks, and vacuum loads. The gradients on the most offending cavities will be reduced and compensated for by increasing the gradients on least offensive cavities. Training data will be collected during this year’s operational program and initial implementation of AI models will be deployed. Preliminary results and future plans are presented.

Carpenter, Adam↗

Qualitative and Quantitative Assessment of Nuclear Materials Contained in High-Activity Waste Arising from the Operations at the 'SHELTER' Facility

As a result of the nuclear accident at the Chernobyl NPP in 1986, the explosion dispeesed nuclear materials contained in the nuclear fuel of the reactor core over the destroyed facilities at Unit No. 4 and over the territory immediately adjacent to the destroyed unit. The debris was buried under the Cascade Wall. Nuclear materials at the SHELTER can be characterized as spent nuclear fuel, fresh fuel assemblies (including fuel assemblies with damaged geometry and integrity, and individual fuel elements), core fragments of the Chernobyl NPP Unit No. 4, finely-dispersed fuel (powder/dust), uranium and plutonium compounds in water solutions, and lava-like nuclear fuel-containing masses. The new safe confinement (NSC) is a facility designed to enclose the Chernobyl NPP Unit No. 4 destroyed by the accident. Construction of the NSC involves excavating operations, which are continuously monitored including for the level of radiation. The findings of such monitoring at the SHELTER site will allow us to characterize the recovered radioactive waste. When a process material categorized as high activity waste (HAW) is detected the following HLW management operations should be involved: HLW collection; HLW fragmentation (if appropriate); loading HAW into the primary package KT-0.2; loading the primary package filled with HAW into the transportation cask KTZV-0.2; and storing the cask in temporary storage facilities for high-level solid waste. The CDAS system is a system of 3He tubes for neutron coincidence counting, and is designed to measure the percentage ratio of specific nuclear materials in a 200-liter drum containing nuclear material intermixed with a matrix. The CDAS consists of panels with helium counter tubes and a polyethylene moderator. The panels are configured to allow one to position a waste-containing drum and a drum manipulator. The system operates on the ‘add a source’ basis using a small Cf-252 source to identify irregularities in the matrix during an assay. The platform with the source is placed under the measurement chamber. The platform with the source material is moved under the measurement chamber. The design allows one to move the platform with the source in and out, thus moving the drum. The CDAS system and radioactive waste containers have been built. For each drum filled with waste two individual measurements (passive/active) will be made. This paper briefly describes the work carried out to assess qualitatively and quantitatively the nuclear materials contained in high-level waste at the SHELTER facility. These efforts substantially increased nuclear safety and security at the facility.

Cherkas, Dmytro↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

Arctic Radiation-Cloud-Aerosol-Surface Interaction eXperiment (ARCSIX)

The Arctic climate system is amidst a transition. Over the last 40 years, the Arctic sea ice pack has transformed from a predominantly thick, multi-year sea ice to a predominantly thin, seasonal sea ice, termed the “New Arctic”. The observed rapid changes in the Arctic sea ice pack are an integral part of the Arctic Amplification phenomenon and represent a response to and a feedback on global climate change. As a result, the role of the Arctic within the global climate system is changing. Substantial uncertainty exists in our understanding of the atmosphere-surface interactions within the Arctic system, limiting our knowledge of the Arctic’s role in the future climate. Advancing our understanding of the Arctic climate system requires (1) measurements of the coupling between radiative processes and sea ice surface properties during summer sea ice melt; (2) measurements of the processes controlling the predominant Arctic cloud regimes and their properties (Fig. 1); and (3) improvements in the ability to monitor Arctic cloud, radiation, and sea ice processes from space. A key challenge is that thin, low clouds that are radiatively important to the Arctic surface energy budget can go undetected (Fig. 1). The Arctic Radiation-Cloud-Aerosol-Surface-Interaction eXperiment (ARCSIX) is an airborne campaign based at the Pituffik Space Base in Greenland from May-August 2024 sponsored by the National Aeronautics and Space Administration (NASA) to address these needs. ARCSIX consists of two airborne measurement campaigns taking place in two 3-week intervals during the early and late sea ice melt season: late May through early June and late July through early August, respectively. ARCSIX science is guided by three broad science questions that encapsulate the key influences of radiation-cloud-aerosol-sea ice coupling and a remote sensing and modeling objective: Science Question 1 (Radiation): What is the impact of the predominant summer Arctic cloud types on the radiative surface energy budget? Science Question 2 (Cloud Life Cycle): What processes control the evolution and maintenance of the predominant cloud regimes in the summertime Arctic? Science Question 3 (Sea Ice): How do the two-way interactions between surface properties and atmospheric forcings affect the sea ice evolution? Remote Sensing and Modeling Objective: Enhance our long-term space-based monitoring and predictive capabilities of Arctic sea ice, clouds, and aerosols.

Patrick Taylor↗

Frisker Response to Soil Concentrations (Bq/g) Compared to NaI(Tl) - 19338

The Chalk River Laboratories (CRL) began nuclear operations in 1947. Portions of the site land areas have become radiologically contaminated through the 1952 National Reactor Experimental (NRX) accident and/or waste management activities over the past 70 years of site operations. The Environmental Remediation Projects Group (ERP) characterizes, and performs risk assessment, and remedial actions, as required over these contaminated land areas. ERP work activities are subject to controls established by CRL's Radiation Protection (RP) Group such that RP establishes the radiological controls and monitoring requirements for ERP field work activities. The different methods of monitoring soil contamination between ERP and the RP program present some challenges in the interpretation and comparison of the two sets of results and the soil disposition. ERP utilizes NaI(Tl) scintillation detectors and MARSSIM land scanning techniques to measure soil concentrations between sample locations and in excavated materials. Whereas, RP utilizes surface contamination monitoring equipment in the form of a 15.5 cm{sup 2} open area pancake Geiger-Mueller (GM) tube detector to measure soil contamination levels reported in counts per minute (cpm). This paper presents a method to evaluate the theoretical best responses that could be obtained from surface contamination monitoring instrumentation for a known concentration (1 Bq/g) of various radionuclides. A static efficiency of cpm/Bq{sup -1} g{sup -1} is obtained from these calculations. These contamination monitoring sensitivities are then used in a MARSSIM scanning sensitivity equation and compared to the scanning sensitivity of an NaI(Tl) scintillation detector. The results demonstrate that the sensitivity of the frisker probes to particle radiations (betas for pancake) tend to fall in a range of only a few cpm/Bq{sup -1} g{sup -1}. Rather, the primary static response of the pancake probe to soil contamination is from gamma radiation where a value of 36 cpm/Bq{sup -1} g{sup -1} for Cs-137 was obtained at 2.54 cm distance without the application of scanning statistics. In comparison, a 7.6 cm x 7.6 cm NaI(Tl) detector has a Cs-137 static response factor of 10,000 cpm/Bq{sup -1} g{sup -1} at 15 cm distance without applying scanning statistics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Observations of the infrared radiation from the nuclei of NGC 1068 and NGC 4151

Data resulting from monitoring the flux of radiation at 11 microns from NGC 1068 and NGC 4151 are presented. There is some evidence for changes of flux of 50% on a time scale of approximately 100 days from NGC 4151. This evidence is suggestive but not compelling. Limits are set on the possible change of the 11-micron flux from NGC 1068. The energy distribution of radiation from NGC 1068 between 8 and 13 microns has been shown to have no spectral features within the accuracy and resolution of our measurement. This is in contrast to energy distributions observed from galactic sources in which the source of energy is generally interpreted as thermal reradiation from grains.

Stein, W. A.↗

Tools used in Space Radiation Operations

The goal of NASA's Radiation Health Program is to achieve human exploration and development of space without exceeding acceptable risk from exposure to ionizing radiation. The Space Radiation Analysis Group (SRAG) at NASA Johnson Space Center carries out this mission by following the philosophy of ALARA – As Low as Reasonably Achievable. SRAG utilizes a variety of tools to maintain awareness of space weather and to monitor the space radiation environment, both internal and external to the vehicle. SRAG develops and manages a wide variety of detectors that are located on the exterior and throughout the interior of the International Space Station and worn by crew. During Artemis I, SRAG provided detectors distributed within Orion’s interior and participated in the MARE experiment, which outfitted female phantoms with thousands of thermoluminescence detectors (TLD) and other dosimeters to better constrain the total dose accrued inside the human during a mission to the Moon. Motivated by the Artemis Exploration Class missions, SRAG and collaborators are developing forecasting capabilities for solar energetic particle (SEP) events and their biological impacts to crew. Tools that have come out of this work include the Acute Radiation Risk Tool (ARRT) and the SEP Scoreboards. This presentation will give an overview of the tools used in SRAG ops and currently under development to support our next steps in human space exploration.

space weather↗

Collisional and Radiative Processes in Adiabatic Deceleration, Deflection, and Off-Axis Trapping of a Rydberg Atom Beam

A supersonic beam of Rydberg hydrogen atoms has been adiabatically deflected by 90 deg., decelerated to zero velocity in less than 25 {mu}s, and loaded into an electric trap. The deflection has allowed the suppression of collisions with atoms in the trailing part of the gas pulse. The processes leading to trap losses, i.e., fluorescence to the ground state, and transitions and ionization induced by blackbody radiation have been monitored over several milliseconds and quantitatively analyzed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Gross Alpha and Beta Decision Levels for the Environmental Air Monitoring Program for the Idaho National Laboratory

This report provides a comprehensive analysis of alpha and beta radiation data collected from air monitoring sites at or near Idaho National Laboratory from April 2006 through February 2017. These data were used to compute monitoring limits that will be used to assess future alpha and beta radiation measurements. Data were analyzed for seasonality, stationarity, and other data issues that may impact the calculation and use of the monitoring limits.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray induced Sm{sup 3+} to Sm{sup 2+} conversion in fluorophosphate and fluoroaluminate glasses for the monitoring of high-doses in microbeam radiation therapy

Fluorophosphate and fluoroaluminate glasses doped with trivalent samarium were evaluated as sensors of x-ray radiation for microbeam radiation therapy at the Canadian Light Source using the conversion of trivalent Sm{sup 3+} to the divalent form Sm{sup 2+}. Both types of glasses show similar conversion rates and may be used as a linear sensor up to {approx}150 Gy and as a nonlinear sensor up to {approx}2400 Gy, where saturation is reached. Experiments with a multi-slit collimator show high spatial resolution of the conversion pattern; the pattern was acquired by a confocal fluorescence microscopy technique. The effects of previous x-ray exposure may be erased by annealing at temperatures exceeding the glass transition temperature T{sub g} while annealing at T{sub A} < T{sub g} enhances the Sm conversion. This enhancement is explained by a thermally stimulated relaxation of host glass ionic matrix surrounding x-ray induced Sm{sup 2+} ions. In addition, some of the Sm{sup 3+}-doped glasses were codoped with Eu{sup 2+}-ions but the results show that there is no marked improvement in the conversion efficiency by the introduction of Eu{sup 2+}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced Design of Radiation Tolerant High-Temperature Structural Health Monitoring Sensors

Acoustic emission sensors are vital in the nuclear industry for real-time structural health monitoring and early detection of material degradation. By capturing high-frequency stress waves emitted from defects like cracks, corrosion, or fatigue, acoustic emission sensors enable non-invasive monitoring of critical components such as reactor vessels, piping, and containment structures. This technology supports predictive maintenance, enhances safety, and ensures regulatory compliance by providing early warnings of potential failures. It is also instrumental in research, particularly in material testing reactors, where it is used to monitor the behavior of fuels and materials under irradiation, by allowing the detection of cracking or other acoustic signals in real time. This enables the evaluation of performance and accident behavior of advanced fuel concepts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

SU-E-CAMPUS-T-04: Measurement of Proton Pencil Beam Spot Profile Using Cherenkov Radiation in Two Dimensional Optical Fiber Arrays

Purpose: Proton therapy aims to deliver a high dose in a well-defined target volume while sparing the healthy surrounding tissues thanks to their inherent depth dose characteristic (Bragg peak). In proton therapy, several techniques can be used to deliver the dose into the target volume. The one that allows the best conformity with the tumor, is called PBS (Pencil Beam Scanning). The measurement of the proton pencil beam spot profile (spot size) and position is very important for the accurate delivery of dose to the target volume with a good conformity. Methods: We have developed a fine segmented detector array to monitor the PBS. A prototype beam monitor using Cherenkov radiation in clear plastic optical fibers (cPOF) has been developed for continuous display of the pencil beam status during the therapeutic proton Pencil Beam Scanning mode operation. The benefit of using Cherenkov radiation is that the optical output is linear to the dose. Pedestal substraction and the gain adjustment between channels are performed. Spot profiles of various pencil beam energies(100 MeV to 226 MeV) are measured. Two dimensional gaussian fit is used to analyze the beam width and the spot center. The results are compared with that of Lynx(Scintillator-based sensor with CCD camera) and EBT3 Film. Results: The measured gaussian widths using fiber array system changes from 13 to 5 mm for the beam energies from 100 to 226 MeV. The results agree well with Lynx and Film within the systematic error. Conclusion: The results demonstrate good monitoring capability of the system. Not only measuing the spot profile but also monitoring dose map by accumulating each spot measurement is available. The x-y monitoing system with 128 channel readout will be mounted to the snout for the in-situ real time monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation Damage Studies and Operation of the DØ Luminosity Monitor

The D0 Luminosity Monitor (LM) employs scintillating wedges with photomultiplier tube readout to detect particles from inelastic collisions in p interactions at the Fermilab Tevatron Collider. The Luminosity Monitor provides a real-time measurement of the relative luminosity during data-taking, and, with the determination of the effective inelastic cross section, it also provides an absolute measurement of the luminosity delivered to the D0 Experiment, which is later used for normalization of D0 physics results. In the course of normal Tevatron operations these scintillators accrue significant radiation damage. Operating parameters are monitored and adjusted to compensate for this degradation, and the scintillators are periodically replaced to facilitate stable performance. Results from radiation damage studies to the scintillator as well as the stability of the luminosity measurement will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seasonal Variation of Indoor Radon Concentration in the Tropics: Comparative studies between Kuala Lumpur, Malaysia and Kerala, India

The radiation dose received by man from indoor radon and its progeny is the largest at more than 50% of total dose received. The seasonal variation of indoor radon concentration in Kerala, India and Kuala Lumpur, Malaysia were studied. The Southwest coast of the Kerala state in India is known to have very high levels of natural background radiation owing to the rare earths rich monazite sand available in large amount. Kuala Lumpur, Malaysia used to be a famous tin mining area where it was done using open cast system. One-year measurements of radon concentration in houses were done for these two regions. It was found that there is considerable seasonal variation in the levels of radon in Kerala but the variation in Kuala Lumpur is only less than 10%.

58 GEOSCIENCES↗

Synchrotron radiation based beam diagnostics at the Fermilab Tevatron

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. Therefore, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transverse beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measurements from the profile monitor to measurements from the flying wire profile systems are presented as are a number of examples of the application of the profile and abort gap intensity measurements to the modelling of Tevatron beam dynamics.

43 PARTICLE ACCELERATORS↗