Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Evaluating the dosimetric effect of treatment-induced changes in virally mediated head and neck cancer patients

Patients with virally mediated head and neck cancer (VMHNC) often present with advanced nodal disease that is highly radioresponsive as demonstrated by tumour and nodal regression during treatment. The resultant changes may impact on the planned dose distribution and so adversely affect the therapeutic ratio. The aim of this study was to evaluate the dosimetric effect of treatment-induced anatomical changes in VMHNC patients who had undergone a replan. Thirteen patients with virally mediated oropharyngeal or nasopharyngeal cancer who presented for definitive radiotherapy between 2005 and 2010 and who had a replan generated were investigated. The dosimetric effect of anatomical changes was quantified by comparing dose–volume histograms (DVH) of primary and nodal gross target volumes and organs at risk (OAR), including spinal cord and parotid glands, from the original plan and a comparison plan. Eleven three-dimensional conformal radiation therapy (3DCRT) and two intensity modulated radiation therapy (IMRT) plans were evaluated. Dose to the spinal cord and brainstem increased by 4.1% and 2.6%, respectively. Mean dose to the parotid glands also increased by 3.5%. In contrast, the dose received by 98% of the primary and nodal gross tumour volumes decreased by 0.15% and 0.3%, respectively, when comparing the initial treatment plan to the comparison plan. In this study, treatment-induced anatomical changes had the greatest impact on OAR dose with negligible effect on the dose to nodal gross tumour volumes. In the era of IMRT, accounting for treatment-induced anatomical changes is important as focus is placed on minimizing the acute and long-term side effects of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Escalation for Locally Advanced Lung Cancer Using Adaptive Radiation Therapy With Simultaneous Integrated Volume-Adapted Boost

Purpose: To test the feasibility of a planned phase 1 study of image-guided adaptive radiation therapy in locally advanced lung cancer. Methods and Materials: Weekly 4-dimensional fan beam computed tomographs (4D FBCT) of 10 lung cancer patients undergoing concurrent chemoradiation therapy were used to simulate adaptive radiation therapy: After an initial intensity modulated radiation therapy plan (0-30 Gy/2 Gy), adaptive replanning was performed on week 2 (30-50 Gy/2 Gy) and week 4 scans (50-66 Gy/2 Gy) to adjust for volume and shape changes of primary tumors and lymph nodes. Week 2 and 4 clinical target volumes (CTV) were deformably warped from the initial planning scan to adjust for anatomical changes. On the week 4 scan, a simultaneous integrated volume-adapted boost was created to the shrunken primary tumor with dose increases in 5 0.4-Gy steps from 66 Gy to 82 Gy in 2 scenarios: plan A, lung isotoxicity; plan B, normal tissue tolerance. Cumulative dose was assessed by deformably mapping and accumulating biologically equivalent dose normalized to 2 Gy-fractions (EQD2). Results: The 82-Gy level was achieved in 1 in 10 patients in scenario A, resulting in a 13.4-Gy EQD2 increase and a 22.1% increase in tumor control probability (TCP) compared to the 66-Gy plan. In scenario B, 2 patients reached the 82-Gy level with a 13.9 Gy EQD2 and 23.4% TCP increase. Conclusions: The tested image-guided adaptive radiation therapy strategy enabled relevant increases in EQD2 and TCP. Normal tissue was often dose limiting, indicating a need to modify the present study design before clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An approach for online evaluations of dose consequences caused by small rotational setup errors in intracranial stereotactic radiation therapy

Purpose: The purpose of this work is to investigate the impact of small rotational errors on the magnitudes and distributions of spatial dose variations for intracranial stereotactic radiotherapy (SRT) treatment setups, and to assess the feasibility of using the original dose map overlaid with rotated contours (ODMORC) method as a fast, online evaluation tool to estimate dose changes (using DVHs) to clinical target volumes (CTVs) and organs-at-risks (OARs) caused by small rotational setup errors. Methods: Fifteen intracranial SRT cases treated with either three-dimensional conformal radiation therapy (3DCRT) or intensity-modulated radiation therapy (IMRT) techniques were chosen for the study. Selected cases have a variety of anatomical dimensions and pathologies. Angles of {+-}3 deg. and {+-}5 deg. in all directions were selected to simulate the rotational errors. Dose variations in different regions of the brain, CTVs, and OARs were evaluated to illustrate the various spatial effects of dose differences before and after rotations. DVHs accounting for rotations that were recomputed by the treatment planning system (TPS) and those generated by the ODMORC method were compared. A framework of a fast algorithm for multicontour rotation implemented by ODMORC is introduced as well. Results: The average values of relative dose variations between original dose and recomputed dose accounting for rotations were greater than 4.0% and 10.0% in absolute mean and in standard deviation, respectively, at the skull and adjacent regions for all cases. They were less than 1.0% and 2.5% in absolute mean and in standard deviation, respectively, for dose points 3 mm away from the skull. The results indicated that spatial dose to any part of the brain organs or tumors separated from the skull or head surface would be relatively stable before and after rotations. Statistical data of CTVs and OARs indicate the lens and cochleas have the large dose variations before and after rotations, whereas the remaining ROIs have insignificant dose differences. DVH comparisons suggest that the ODMORC method is able to estimate the DVH of CTVs fairly accurately (within 1.5% of relative dose differences for evaluation volumes). The results also show that most of the OARs including the brain stem, spinal cord, chiasm, hippocampuses, optic nerves, and retinas, which were relatively distal from the skull and surface, had good agreement (within 2.0% of relative dose differences for 0.1 cc of the volumes ) between the ODMORC method and the recomputation, whereas OARs more proximate to the bone-tissue interface or surface, such as the lenses and cochlea, had larger dose variations (greater than 5.0%) for some cases due to the incapability of the ODMORC to account for scatter contribution variations proximate to interfaces and intrinsic dose calculation uncertainties for ROIs with small volumes. Conclusions: The ODMORC method can be implemented as an online evaluation system for rotation-induced dose changes of CTVs and most OARs and for other related dose consequence analyses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flash photoionization of gamma-ray burst environments

The H-alpha line emission that a flash-photoionized region emits is calculated. Archival transients, as well as various theoretical predictions, suggest that there may be significant ionizing flux. The limits on the line flux which might be observable indicate that the density must be fairly high for the recombination radiation to be observable. The intense burst radiation is insufficient to melt the dust which will be present in such a dense medium. This dust may attenuate the observable line emission, but does not attenuate the ionizing radiation before it ionizes the neutral medium surrounding the burst source. The dust can also produce a light echo. If there are indeed gamma-ray bursts in dense clouds, then it is possible that the burst was triggered by Bondi-Hoyle accretion from the dense medium, although it is unlikely on statistical grounds that all bursts occur in clouds.

Band, David L.↗

Method for Describing the Angular Distribution of Optical Radiation Scattered by a Monolayer of Ordered Spherical Particles (Normal Illumination)

We have developed a method for describing the angular distribution of intensity of radiation scattered by a monolayer of homogeneous spatially ordered monodisperse spherical particles normally illuminated by a plane circularly polarized electromagnetic wave. The method is based on the quasicrystalline approximation (QCA) of the theory of multiple scattering of waves (TMSW) using the multipole expansion of fields and the tensor Green function in vectorial spherical wavefunctions. The method is applied for analyzing the characteristics of radiation scattered by a partially ordered monolayer and a monolayer with a nonideal lattice. The results of calculations are compared with the available experimental data on the position of the first-order diffraction peak on the angular and spectral dependences of the intensity of radiation scattered by a closely packed monolayer with a nonideal triangular lattice of SiO{sub 2} particles. Good conformity of the results has been established.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Maximum power flux of auroral kilometric radiation

Distant observations of intense auroral kilometric radiation (AKR) are discussed in light of the increased maximum AKR power flux registered by the 3D radio-mapping instrument on ISEE 3. Only AKR events that contain the highest frequency signals are selected, and during spacecraft rotation the spacecraft antenna gain is employed to increase the dynamic range of the instrument. The technique is found to result in the screening of false signals created by instrument overloading as well as the detection of genuine second-harmonic AKR signals while the spacecraft was 17 R(E) from earth. A very strong power flux of fundamental AKR is also reported, exceeding 3 x 10 to the -13th W/sq m/Hz at 360 kHz. The most intense source-region values detected by Isis I and Viking measurements are compared to the strong signal, and the signal is concluded to be the combined signal of a number of sources.

Benson, Robert F.↗

Solar Sources of Severe Space Weather

Severe space weather is characterized by intense particle radiation from the Sun and severe geomagnetic storm caused by magnetized solar plasma arriving at Earth. Intense particle radiation is almost always caused by coronal mass ejections (CMEs) traveling from the Sun at super-Alfvenic speeds leading to fast-mode MHD shocks and particle acceleration by the shocks. When a CME arrives at Earth, it can interact with Earth's magnetopause resulting in solar plasma entry into the magnetosphere and a geomagnetic storm depending on the magnetic structure of the CME. Particle radiation starts affecting geospace as soon as the CMEs leave the Sun and the geospace may be immersed in the radiation for several days. On the other hand, the geomagnetic storm happens only upon arrival of the CME at Earth. The requirements for the production of particles and magnetic storms by CMEs are different in a number of respects: solar source location, CME magnetic structure, conditions in the ambient solar wind, and shock-driving ability of CMEs. Occasionally, intense geomagnetic storms are caused by corotating interaction regions (CIRs) that form in the interplanetary space when the fast solar wind from coronal holes overtakes the slow wind from the quiet regions. CIRs also accelerate particles, but when they reach several AU from the Sun, so their impact on Earth's space environment is not significant. In addition to these plasma effects, solar flares that accompany CMEs also produce excess ionization in the ionosphere causing sudden ionospheric disturbances. This paper highlights these space weather effects using space weather events observed by space and ground based instruments during of solar cycles 23 and 24.

Gopalswamy, N.↗

Quantifying the Combined Effect of Radiation Therapy and Hyperthermia in Terms of Equivalent Dose Distributions

Purpose: To develop a method to quantify the therapeutic effect of radiosensitization by hyperthermia; to this end, a numerical method was proposed to convert radiation therapy dose distributions with hyperthermia to equivalent dose distributions without hyperthermia. Methods and Materials: Clinical intensity modulated radiation therapy plans were created for 15 prostate cancer cases. To simulate a clinically relevant heterogeneous temperature distribution, hyperthermia treatment planning was performed for heating with the AMC-8 system. The temperature-dependent parameters α (Gy{sup −1}) and β (Gy{sup −2}) of the linear–quadratic model for prostate cancer were estimated from the literature. No thermal enhancement was assumed for normal tissue. The intensity modulated radiation therapy plans and temperature distributions were exported to our in-house-developed radiation therapy treatment planning system, APlan, and equivalent dose distributions without hyperthermia were calculated voxel by voxel using the linear–quadratic model. Results: The planned average tumor temperatures T90, T50, and T10 in the planning target volume were 40.5°C, 41.6°C, and 42.4°C, respectively. The planned minimum, mean, and maximum radiation therapy doses were 62.9 Gy, 76.0 Gy, and 81.0 Gy, respectively. Adding hyperthermia yielded an equivalent dose distribution with an extended 95% isodose level. The equivalent minimum, mean, and maximum doses reflecting the radiosensitization by hyperthermia were 70.3 Gy, 86.3 Gy, and 93.6 Gy, respectively, for a linear increase of α with temperature. This can be considered similar to a dose escalation with a substantial increase in tumor control probability for high-risk prostate carcinoma. Conclusion: A model to quantify the effect of combined radiation therapy and hyperthermia in terms of equivalent dose distributions was presented. This model is particularly instructive to estimate the potential effects of interaction from different treatment modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The ionization equilibrium inside the RHO Ophiuchi cloud

Observational technology is now reaching the point where optical absorption-line studies of dark interstellar clouds are becoming feasible. Such studies are of great interest. In particular, it will be important to discover the degree of depletion which has occurred in dark clouds. In order to assess depletions on the basis of observations of a limited range of ionization stages, it is necessary to analyze the ionization balance. The present investigation is concerned with such an analysis. The two key parameters necessary for deducing the ionization balance are the electron density and the radiation field intensity. A summary is provided regarding the existing data on the cloud density using data from the literature, and the radiation field intensity is derived from the observed H2 rotational excitation. The implications of both the density and radiation field data for the ionization balance of several species are discussed. It is found that for all species treated the first ion is dominant in the line of sight toward HD 147889.

Snow, T. P., Jr.↗

Modification of a graphene – copper substrate in vacuum by femtosecond laser radiation

The effect of intense femtosecond laser radiation on single-layer graphene fixed on a copper fine-meshed grid is studied using a compact femtosecond electron diffractometer. A modification of the graphene – copper substrate is found. The composition of the resulting compounds is analysed. It is shown that the main new products are copper oxides. The prospects of using such a substrate in the method of ultrafast electron diffraction and microscopy are analysed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Initial Report of Pencil Beam Scanning Proton Therapy for Posthysterectomy Patients With Gynecologic Cancer

Purpose: To report the acute toxicities associated with pencil beam scanning proton beam radiation therapy (PBS) for whole pelvis radiation therapy in women with gynecologic cancers and the results of a dosimetric comparison of PBS versus intensity modulated radiation therapy (IMRT) plans. Methods and Materials: Eleven patients with posthysterectomy gynecologic cancer received PBS to the whole pelvis. The patients received a dose of 45 to 50.4 Gy relative biological effectiveness (RBE) in 1.8 Gy (RBE) daily fractions. Acute toxicity was scored according to the Common Terminology Criteria for Adverse Events, version 4. A dosimetric comparison between a 2-field posterior oblique beam PBS and an IMRT plan was conducted. The Wilcoxon signed rank test was used to assess the potential dosimetric differences between the 2 plans and PBS target coverage robustness relative to setup uncertainties. Results: The median patient age was 55 years (range 23-76). The primary site was cervical in 7, vaginal in 1, and endometrial in 3. Of the 11 patients, 7 received concurrent cisplatin, 1 each received sandwich carboplatin and paclitaxel chemotherapy, both sandwich and concurrent chemotherapy, and concurrent and adjuvant chemotherapy, and 1 received no chemotherapy. All patients completed treatment. Of the 9 patients who received concurrent chemotherapy, the rate of grade 2 and 3 hematologic toxicities was 33% and 11%, respectively. One patient (9%) developed grade 3 acute gastrointestinal toxicity; no patient developed grade ≥3 genitourinary toxicity. The volume of pelvic bone marrow, bladder, and small bowel receiving 10 to 30 Gy was significantly lower with PBS than with intensity modulated radiation therapy (P<.001). The target coverage for all PBS plans was robust relative to the setup uncertainties (P>.05) with the clinical target volume mean dose percentage received by 95% and 98% of the target volume coverage changes within 2% for the individual plans. Conclusions: Our results have demonstrated the clinical feasibility of PBS and the dosimetric advantages, especially for the low-dose sparing of normal tissues in the pelvis with the target robustness maintained relative to the setup uncertainties. Future studies with larger patient numbers are planned to further validate our preliminary findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the possibility of the generation of high harmonics with photon energies greater than 10 keV upon interaction of intense mid-IR radiation with neutral gases

Based on the analytical quantum-mechanical description in the framework of the modified strong-field approximation, we have investigated high harmonic generation of mid-IR laser radiation in neutral gases taking into account the depletion of bound atomic levels of the working medium and the electron magnetic drift in a high-intensity laser field. The possibility is shown to generate high-order harmonics with photon energies greater than 10 keV under irradiation of helium atoms by intense femtosecond laser pulses with a centre wavelength of 8 – 10.6 μm. (interaction of radiation with matter)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-A-BRD-01: Innovation in Radiation Therapy Planning I: Knowledge Guided Treatment Planning

Intensity modulated radiation therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) offer the capability of normal tissues and organs sparing. However, the exact amount of sparing is often unknown until the plan is complete. This lack of prior guidance has led to the iterative, trial and-error approach in current planning practice. Even with this effort the search for patient-specific optimal organ sparing is still strongly influenced by planner's experience. While experience generally helps in maximizing the dosimetric advantages of IMRT/VMAT, there have been several reports showing unnecessarily high degree of plan quality variability at individual institutions and amongst different institutions, even with a large amount of experience and the best available tools. Further, when physician and physicist evaluate a plan, the dosimetric quality of the plan is often compared with a standard protocol that ignores individual patient anatomy and tumor characteristic variations. In recent years, developments of knowledge models for clinical IMRT/VMAT planning guidance have shown promising clinical potentials. These knowledge models extract past expert clinical experience into mathematical models that predict dose sparing references at patient-specific level. For physicians and planners, these references provide objective values that reflect best achievable dosimetric constraints. For quality assurance, applying patient-specific dosimetry requirements will enable more quantitative and objective assessment of protocol compliance for complex IMRT planning. Learning Objectives: Modeling and representation of knowledge for knowledge-guided treatment planning. Demonstrations of knowledge-guided treatment planning with a few clinical caanatomical sites. Validation and evaluation of knowledge models for cost and quality effective standardization of plan optimization.

60 APPLIED LIFE SCIENCES↗

Model for the 5 March 1979 gamma-ray transient

A model is proposed for the March 5, 1979 gamma-ray transient. A small lump of strange matter, previously ejected from a supernova explosion, struck a slowly rotating strange star. This resulted in a high-intensity flash of radiation from a hot spot produced by the impact. The high-intensity radiation blew open a crater in the crust; the energy released as this crater refilled was responsible for the longer-duration, lower-intensity phase. The 8-s modulation is due to the rotation of the star. A plausible scenario for the production of this event is discussed.

Alcock, Charles↗

Infrared dust and millimeter-wave carbon monoxide emission in the Orion region

The far-infrared dust emission seen by the IRAS satellite in the Orion region is analyzed as a function of the local radiation field intensity, and the dust temperature and opacity are compared with (C-12)O and (C-13)O emission. The infrared radiation is interpreted within the framework of a single-component large grain model and a multicomponent grain model consisting of subpopulations of grains with size-dependent temperatures. A strong dependence of the 100-micron optical depth derived is found using the large grain model on the average line-of-sight dust temperature and radiation field. In the hot environment surrounding high-luminosity sources and H II regions, all dust along the line-of-sight radiates at 100 microns, and the dust-to-gas ratio, based on the 100-micron opacity and I(/C-13/O), appears to be in agreement with the standard value, about 1 percent by mass. A relationship is found between the inferred dust-to-gas ratio and the radiation field intensity responsible for heating the dust which can be used to estimate the gas column density from the dust opacity derived from the 60- and 100-micron IRAS fluxes.

Bally, John↗

Computed Tomography Number Changes Observed During Computed Tomography–Guided Radiation Therapy for Head and Neck Cancer

Purpose: To investigate CT number (CTN) changes in gross tumor volume (GTV) and organ at risk (OAR) according to daily diagnostic-quality CT acquired during CT-guided intensity modulated radiation therapy for head and neck cancer (HNC) patients. Methods and Materials: Computed tomography scans acquired using a CT-on-rails during daily CT-guided intensity modulated radiation therapy for 15 patients with stage II to IVa squamous cell carcinoma of the head and neck were analyzed. The GTV, parotid glands, spinal cord, and nonspecified tissue were generated on each selected daily CT. The changes in CTN distributions and the mean and mode values were collected. Pearson analysis was used to assess the correlation between the CTN change, organ volume reduction, and delivered radiation dose. Results: Volume and CTN changes for GTV and parotid glands can be observed during radiation therapy delivery for HNC. The mean (±SD) CTNs in GTV and ipsi- and contralateral parotid glands were reduced by 6 ± 10, 8 ± 7, and 11 ± 10 Hounsfield units, respectively, for all patients studied. The mean CTN changes in both spinal cord and nonspecified tissue were almost invisible (<2 Hounsfield units). For 2 patients studied, the absolute mean CTN changes in GTV and parotid glands were strongly correlated with the dose delivered (P<.001 and P<.05, respectively). For the correlation between CTN reductions and delivered isodose bins for parotid glands, the Pearson coefficient varied from −0.98 (P<.001) in regions with low-dose bins to 0.96 (P<.001) in high-dose bins and were patient specific. Conclusions: The CTN can be reduced in tumor and parotid glands during the course of radiation therapy for HNC. There was a fair correlation between CTN reduction and radiation doses for a subset of patients, whereas the correlation between CTN reductions and volume reductions in GTV and parotid glands were weak. More studies are needed to understand the mechanism for the radiation-induced CTN changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transversely diode-pumped alkali metal vapour laser

We have studied theoretically the operation of a transversely diode-pumped alkali metal vapour laser. For the case of high-intensity laser radiation, we have obtained an analytical solution to a complex system of differential equations describing the laser. This solution allows one to exhaustively determine all the energy characteristics of the laser and to find optimal parameters of the working medium and pump radiation (temperature, buffer gas pressure, and intensity and width of the pump spectrum). (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗