Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Implementational Aspects for the Characterization of Low-Inertia in Power Systems

The replacement of conventional generating units with non-conventional renewable energy resources impacts the stability of the power system. While the general goal of supplying demand could be achieved from both generation resources, inverter-based energy resources are different from traditional synchronous machines in the sense that they do not inherently provide inertia to the system. The latter obviously worsen the system ability to maintain the balance between supply and demand after certain contingencies such as generator outages. With high integration of renewable-based generation resources, there is a reduction in total system inertia, which could lead to systems with less time to react for frequency restoration in case of such unexpected unit failures. While conceptually it is true, there is a missing gap in the field of power system stability community in terms of test-bed power systems for characterizing low-inertia conditions. In this paper, a framework for low-inertia power systems is presented. The purpose of the test-bed is to establish an environment for testing and conducting research on power systems experiencing low-inertia issues. The frequency nadir, the rate of change of frequency, and the under-frequency load shedding scheme are used as a measure of the healthiness of power grids.

Baquedano-Aguilar, Mario D.↗

Electromagnetic Transient Simulation of Photovoltaic Inverter Using Implicit-Explicit Solver

This paper introduces the implementation of electromagnetic transient (EMT) simulations of a photovoltaic (PV) inverter module using the Implicit-Explicit (ImEx) solver in the Suite of Nonlinear and Differential/Algebraic Equation Solvers (SUNDIALS). This study demonstrates the effectiveness of the ImEx solver in overcoming the challenges inherent in simulating the complex dynamics of PV inverter modules. Furthermore, using SUNDIALS’ ImEx solver module ARKODE for EMT simulation automates key aspects of the process, such as numerical integration, providing substantial benefits including enhanced consistency, faster implementation, reduced human error, and the capability to handle the complexities of advanced numerical integration. By conducting comparative simulations with an implicit method used in commercial software, the research showcases the ImEx solver’s capability in achieving high accuracy and reliability. Results indicate that leveraging the ImEx approach significantly enhances modeling fidelity and reduces simulation setup times, offering a promising tool for the EMT analysis of PV inverter systems in power electronics-dominated power grids.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

Regional Inertia Estimation Using Actual Event Measurements: Florida Case

As inverter-based resources’ integration in power grids increases, their uneven distribution across the electrical network leads to the formation of local regions that are weakly coupled to the larger interconnection. This signifies the necessity of regional frequency dynamics investigation and analyzing various inertia metrics. This paper presents a practical methodology for estimating regional rate-of-change of frequency (RoCoF) using actual event recordings, which is then used to evaluate regional inertia. Florida (FL) is selected as the region of interest due to its distinct regional frequency dynamics and the rising levels of solar generation. We identify and analyze confirmed events from 2017 to 2024 that occurred in FL. The results indicate that FL contributes about 14% to the total inertia of the US Eastern Interconnection, which approximately matches its share of generation capacity. Results also highlight seasonal fluctuations in energy generation, which play a significant role in influencing inertia and thus the RoCoF levels. This emphasizes the importance of estimating regional inertia to enhance grid operations for a future that focuses on distributed generation.

Dulal, Saurav [University of Tennessee, Knoxville ↗

A Semi-Analytical Approach for State-Space Electromagnetic Transient Simulation

Here, this paper proposes a semi-analytical approach for efficient and accurate electromagnetic transient (EMT) simulation of a power grid. The approach first derives a high-order semi-analytical solution (SAS) of the grid’s state-space EMT model using the differential transformation (DT), and then evaluates the solution over enlarged, variable time steps to significantly accelerate the simulations while maintaining its high accuracy on detailed fast EMT dynamics. The approach also addresses switches during large time steps by using a limit violation detection algorithm with a binary search-enhanced quadratic interpolation. Case studies are conducted on EMT models of the IEEE 39-bus system and large-scale systems to demonstrate the merits of the new simulation approach against traditional numerical methods.

electromagnetic transient↗

Electromagnetic Transient Simulation of Large-Scale Inverter-Based Resources With High-Granularity

The power grid is undergoing a significant transformation with the rapid increase in inverter-based resources (IBRs), including large-scale photovoltaic (PV) plants. Ensuring reliable and resilient grid operation in this new paradigm necessitates high-granularity electromagnetic transient (EMT) modeling that accurately captures the behavior of individual inverters and their interactions within IBR plants. Central to this approach is the detailed representation of both the IBR plant’s collector system and the dynamics of individual inverters. To achieve this, a high-granularity EMT model of a large-scale PV plant has been developed using advanced simulation algorithms, including matrix splitting and the Schur complement. These proposed techniques significantly enhance simulation speed, numerical stability, and accuracy while improving the modularity and efficiency of the collector system’s representation. The effectiveness of the proposed methods is validated through simulations of a representative large-scale PV plant consisting of 125 individual PV inverters, 25 IBR unit transformers, and a 52-bus collector system.

Choi, Jongchan [Oak Ridge National Laboratory (ORN↗

Optimal Complementarity Analysis of Potential Floating Solar Co-Located With Existing Hydropower Assets Across the Contiguous United States

The U.S. is expected to double its rate of renewable capacity from 2024 to 2030. However, the stochastic nature of renewable energy poses challenges to the operation and reliability of our power grid. The combined generation from renewable energy sources, with dispatchable sources (such as hydropower) operating as a hybrid energy plant, could mitigate this variability. In this paper, the complementarity analysis of selected U.S. reservoirs with existing hydropower assets (EHAs) and potential floating photovoltaics (FPVs) is conducted for the continuous U.S. (CONUS). The optimal FPV capacity for each site is determined by minimizing the variability of the combined output, while adhering to the FPV potential. Our results indicate that over 50% of the analyzed reservoirs achieve a stability coefficient exceeding 0.5, leading to a less-variable output after optimization. Finally, we analyze the complementary hydro-FPV hybrid reservoirs by considering both the Pearson correlation coefficient and the stability coefficient on daily, monthly, and yearly scales. Summaries are included of locations of theoretical FPVs co-located with hydropower plants that exhibit high complementarity based on the selected metrics.

13 - HYDRO ENERGY↗

Open-Source Architecture for Multi-Party Update Verification for Data Acquisition Devices

Power grids are integral parts of modern daily life and are increasingly under cyberattack. Common software update processes for grid control devices rely on only one organization to provide verification. This paper roposes a multi-signature software update process to help better secure data acquisition devices from malicious actions by using standard cryptosystems such as TLS. A prototype system build on Linux and off-the-shelf hardware has shown successful update and attack prevention with our customized multi-party update software.

Newberg, Benjamin↗

Stochastic Home Energy Management Systems with Varying Controllable Resources

This paper studies the performance of a model predictive control (MPC) algorithm in a home energy management system (HEMS) as the set of controllable resources varies and under both a constant and a time-of-use (TOU) electricity price structure. The set of controllable resources includes residentially-owned photovoltaic (PV) panels, a home battery system (HBS), an electric vehicle (EV), and a home heating, ventilation, and air conditioning (HVAC) system. The HEMS optimally schedules the set of controllable resources given user preferences such as indoor thermal comfort and electricity cost sensitivity. The home energy management system is built on a chance constrained, MPC-based algorithm, where the chance constraint ensures the indoor thermal comfort is satisfied with a high probability given uncertainty in the outdoor temperature and solar irradiance forecasts. Simulation results for varying sets of controllable resources under two different electricity price structures demonstrate the variation in the HEMS control with respect to HBS operation, electricity cost, and grid power usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Battery Equivalent Model for Residential HVAC

Flexible loads, especially heating, ventilation, and air-conditioning (HVAC) systems can be used to provide a battery-like service to the power grid by varying their demand up and down over a baseline. Recent work has reported that the round-trip efficiency for providing grid services with HVAC systems can be close to 1. Inspired by this promising result, in this work, we rigorously develop a battery equivalent model (BEM) for residential HVAC systems. Relying only on typically available data, the proposed BEM will bridge the observability and controllability gaps between utility companies and customers. The proposed BEM will enable the utility companies to manage the flexible HVAC devices as easy as charging/discharging the conventional energy storage devices. Validated physics-based models are used to train the BEM, whose prediction accuracy is illustrated through a simulation study.

Dong, Jin↗

Distributed Solution Approach for a Stackelberg Pricing Game of Aggregated Demand Response

Demand-side management is a fundamental up-to-date strategy that transforms the traditional power grid to a modern smart grid where the flexible pricing mechanisms play a critical role in its successful implementation. In this paper, the pricing-demand response between a distribution system operator (DSO) and load aggregators (LAs) is modeled as a Stackelberg game, where the DSO is the price maker that adjusts its strategy based on observed responses from LAs. With the concerns of computational cost and privacy protection, two distributed solution approaches, particle swarm optimization and pattern search algorithm, are conducted and compared with the classical centralized backward induction approach. Numerical results on a small case study demonstrate the effectiveness of the proposed distributed solution approaches in leveraging flexible demand response potential.

Chen, Yang↗

Transactive HVAC Agent - Design and Performance Evaluation

Transactive energy systems are playing an increasingly important role in the efficient and reliable marketbased operation of the power grid. Since a significant portion of the residential building energy consumption is from heating ventilation and air conditioning (HVAC) systems, HVAC is one of the most promising resources to provide load flexibility. However, utilizing HVAC flexibility to provide various grid services while simultaneously maintaining consumer comfort and cost-reductions is challenging. This paper presents a design of a transactive HVAC agent (T-HVAC) to be used as a supervisory control for the HVAC system that can simultaneously ensure comfort and cost-reduction. In particular, the T-HVAC a) estimates HVAC thermal dynamics, b) ensures optimal operations of the HVAC system, and c) participates into markets, and d) implements a market-based control via controlling the thermostat temperature set-point. The T-HVAC performance is demonstrated through multiple scenarios and illustrations.

Demand flexibility, distribution system, HVAC, Tra↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the PJM Interconnection. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure to a multitude of cybersecurity threats. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a hydropower-integrated BESS topology, specifically analyzing the slow regulation signal (Reg A) coming from the PJM market. Our simulation results demonstrate that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's transient instability during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

ByzSec — A Multi-layered Byzantine Resilient Architecture for Bulk Power System Protective Relays

Reliability, selectivity, and sensitivity are the fundamental attributes of any protection system, acting as the main drivers in the selection of schemes, and equipment. In high-voltage systems, microprocessor-based relays represent the industry’s preferred solution, providing engineers with a vast array of benefits. However, they remain vulnerable to cybersecurity events that may compromise their functionality. To help mitigate against potential cybersecurity risks, this paper presents a fault-tolerant, Byzantine Resilient (BR) architecture that significantly increases the cybersecurity attributes of a protection system while minimizing the amount of performance impacts and integration overheads introduced. The solution relies on an array of independent relays that utilize robust consensus methods (based on Spire [1], [2]) to ensure correct system behavior is achieved even when a relay has been compromised. Furthermore, the solution has been complemented with a custom-built Situational Awareness engine that can be used to detect and identify potential threats. The implemented solution has been developed in consultation with three hardware vendors and has been tested to comply with the performance requirements of a 345kV differential protection scheme (87T). The results indicate that the proposed architecture is a comprehensive solution that: supports the strict correctness and performance requirements of the bulk power grid while providing a cost-effective alternative that offers a seamless, long-term solution.

byzantine security, Fault Tolerant Application Sof↗

Power System Recovery Coordinated with (Non-)Black-Start Generators

Power restoration is an urgent task after a black-out, and recovery efficiency is critical when quantifying system resilience. Multiple elements should be considered to restore the power system quickly and safely. This paper proposes a recovery model to solve a direct-current optimal power flow (DCOPF) based on mixed-integer linear programming (MILP). Since most of the generators cannot start independently, the interaction between black-start (BS) and non-black-start (NBS) generators must be modeled appropriately. The energization status of the NBS is coordinated with the recovery status of transmission lines, and both of them are modeled as binary variables. Also, only after an NBS unit receives the cranking power through connected transmission lines, will it be allowed to participate in the following system dispatch. The amount of cranking power is estimated as a fixed proportion to the maximum generation capacity. The proposed model is validated on several test systems, as well as a 1393-bus representation system of the Puerto Rican electric power grid. Test results demonstrate how the recovery of NBS units and damaged transmission lines can be optimized, resulting in an efficient and well-coordinated recovery procedure.

Zhao, Meng↗

Distributed Control and Optimization of Virtual Inertia in Power Systems

The integration of renewable energy sources into power grids through inverter-based resources (IBRs) reduces system inertia, leading to faster frequency dynamics and potential grid instability. This paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources during system disturbances, enhancing both system stability and economic performance. Furthermore, we integrate this approach with the traditional inertia placement problem, demonstrating its suitability for existing frameworks. We validate its effectiveness in a 4-bus test system and a two-area 8-bus test system, showcasing its potential for scalable, dynamic inertia management in low-inertia grids.

Yadav, Ajay [ORNL] (ORCID:000000016111881X)↗

A Randomization-Based, Zero-Trust Cyberattack Detection Method for Hierarchical Systems

This paper demonstrates a novel randomization-based approach for verifying power system control signals with application to detecting cyberattacks. We consider fully connected hierarchical systems containing multiple local agents and a global "trust" agent. The global agent uses a time-varying randomized assignment scheme to identify corrupt network links based on principles of zero trust and majority rule. To evaluate the performance of this detection approach, we implement our algorithm in MATLAB and run it against nearly 43 million unique attack scenarios spanning a range of system sizes. For each scenario, the algorithm determines whether the identified corruptions satisfy a set of validity constraints reflecting network topology and uses that result to say whether the recovered state value for one or more local agents is malicious. We compare the algorithm's determination to the true state of the system to assess performance and find that classification accuracy converges to 100% as system size increases, suggesting that the validity constraints become more difficult to satisfy for larger systems. We further explore the scenarios that evade detection to understand practical implications for employing this detection approach.

cybersecurity↗

OpenSAMPL: An Open Source Library for Timing and Synchronization Measurements and Analytics

Today's power grid operators are implementing timing and synchronization solutions that provide resilience to Global Navigation Satellite System (GNSS) vulnerabilities. These vendor-specific solutions often come with additional software applications that are designed to monitor that vendor's synchronization performance data. However, resilient timing architectures often resulting in multi-vendor solutions, including approaches that blend terrestrial clocks with space-based subscription services. In such an environment, collecting, analyzing, and visualizing data from a variety of sources within a single platform was heretofore not possible. To address this need, the US Department of Energy's Center for Alternative Synchronization and Timing (CAST) developed OpenSAMPL, the Open Synchronized Analytics and Monitoring Platform, an open-source Python framework for processing, loading, and observing clock measurement data from distributed devices. OpenSAMPL enables the ingestion of diverse clock-probe sources into a scalable time-series database and applies robust analytics. OpenSAMPL currently supports two vendor data pipelines, and will be extended to more in the near future, enabling seamless monitoring of a variety of timing and synchronization devices in a common environment.

Grant, Josh [ORNL] (ORCID:0000000163475060)↗

Losing Control of Your Linear Network? Try Resilience Theory

Resilience of cyber-physical networks to unexpected failures is a critical need widely recognized across domains. For instance, power grids, telecommunication networks, transportation infrastructures, and water treatment systems have all been subject to disruptive malfunctions and catastrophic cyberattacks. Following such adverse events, we investigate scenarios where a node of a linear network suffers a loss of control authority over some of its actuators. These actuators are not following the controller's commands and are instead producing undesirable outputs. The repercussions of such a loss of control can propagate and destabilize the whole network despite the malfunction occurring at a single node. To assess system vulnerability, we establish resilience conditions for networks with a subsystem enduring a loss of control authority over some of its actuators. Furthermore, we quantify the destabilizing impact on the overall network when such a malfunction perturbs a nonresilient subsystem. We illustrate our resilience conditions on two academic examples, on an islanded microgrid and on the linearized IEEE 39-bus system.

97 MATHEMATICS AND COMPUTING↗