Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power distribution network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interconnection Cost Analysis in ISO-New England

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data for 194 projects in New England from interconnection studies performed between 2010 and 2021. Project-level cost summary data are available for download on this page. We find: -Interconnection costs have grown over time, especially for projects that withdraw. -Interconnection costs are highest for onshore wind, followed by solar and storage. Natural gas and offshore wind projects tend to cost less to interconnect, in comparison. -Economies of scale exist for solar and possibly storage projects, but not for other resource types. -Wind and solar projects requesting capacity network resource interconnection service have higher interconnection costs, despite being evaluated using the same interconnection standard in the analyzed studies. -Low and high interconnection costs can be found throughout the ISO-NE footprint. -Costs are split fairly evenly between investments at the point of interconnection and within the broader network for active and withdrawn projects, while complete projects incur most costs at the point of interconnection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronization of Electric Power Networks

Invited contribution to the ITU News Magazine – Special Edition on “Future use and applications of the Coordinated Universal Time (UTC)” a joint ITU-BIPM initiative. The ITU will produce a special edition of its ITU News Magazine that will feature the “Future use and applications of the Coordinated Universal Time (UTC)”, a joint ITU-BIPM initiative, planned for publication in March or April, 2023. The main objective of the magazine is to educate telecommunication society about existing status of UTC applications, objectives, and possible ways to resolve the leap second issues. This article on “Synchronization of electrical distribution networks” for this edition, highlighting some of the key issues that will help the understanding of the important issues that are related to the coordinated universal time (UTC) and its dissemination.

Dagle, Jeffery E.↗

Measurement-informed Dynamic Aggregation of Distribution Systems

This paper proposes a measurement-informed dynamic aggregation methodology in order to create equivalent representations of distribution systems that are compatible with large-scale transmission analysis. By optimizing an equivalent feeder parameters using time-series measurements of active power, reactive power, and voltage at the Point of Interconnection (POI), the approach yields simplified yet dynamically accurate equivalents. Implemented in PSCAD with models of photovoltaic–battery systems, three-phase motors, and static loads, the method employs hybrid differential evolution and bounded least-squares optimization laying the foundation for for real-time state estimation and optimized sensor placement in distribution networks.

Ahmed, Kazi Ishrak [University of Tennessee, Knoxv↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Game Theory Approaches for System-level Incentive Design

This report presents a generalized Stackelberg game framework for designing and evaluating financial incentives that enhance power system resilience through strategic deployment of distributed energy resources(DERs) under various contingencies. The proposed approach addresses the challenge of coordinating individual community investment decisions to meet system-wide resilience objectives. The framework is demonstrated in a three-community test system subjected to two transmission contingency scenarios: inter-community line failure (Case 1) and complete main grid disconnection (Case 2). In both cases, three incentive levels are compared: a Base case with no financial incentives, and low and high incentive cases. In Case 1, the Base case (no incentives) results in a total installed DER capacity of 217.2 MW, with no load shedding due to alternative routing, but community costs remain high. Increasing incentives raises DER deployment to 286.9 MW, lowers aggregate community costs by $22M annually, and completely avoids the need for costly new transmission line construction. In Case 2, the Base case results in 24.3 MWh of unserved load; introducing incentives eliminates all load shedding and ensures up to 89 MWh of battery storage is available for emergency reserve. These results demonstrate that targeted incentives can dramatically improve grid resilience and cost-effectiveness. The framework thus offers policymakers and system planners a robust tool to quantify and compare the effectiveness of incentive programs for multi-community transmission networks behavior, system resilience, and economic efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Northeast Freight Corridor Charging Plan

Medium- and heavy-duty freight rely on service plazas and truck stops to refuel their vehicles and meet their obligations. Creating a reliable fast-charging network across the Northeast is critical to provide security for fleets to electrify.

02 PETROLEUM↗

Role of Inverter-Based Resources (IBRs) in Energizing Remote Generating Stations

The increasing integration of Inverter-Based Resources (IBRs) into the system has brought significant focus on their role in blackstart and restoration procedures. Their advantageous features, such as low startup power requirements, operational flexibility across a wide range of power factors, rapid controllability, and the ability to energize a network at lower voltage levels necessitate a reassessment of existing restoration protocols. This paper seeks to showcase how IBRs can utilize their grid-forming capabilities to provide power to a remote generating station through detailed EMT simulation studies using data collected from an existing portion of a network.

blackstart procedure↗

Impact of Emergency Diesel Generator Reliability on Microgrids and Building-Tied Systems

Microgrids are an emerging alternative as an energy backup system for critical electric loads and have improved performance compared to the traditional architecture where a single emergency diesel generator is tied to an individual building. Both architectures are dependent on the reliability of their individual generators and a quantitative and realistic comparison of the overall system reliability of the two architectures is lacking. Using recently published work on emergency diesel generator finite reliability, a quantitative methodology is presented to compare the reliability of a microgrid architecture based on centralized emergency diesel generators to the traditional approach of generators tied to individual buildings. Three system reliability performance metrics are calculated as a function of outage duration: (1) probability to meet 100% of the critical load; (2) expected fraction of lost load; and (3) probability to meet the highest priority critical loads. It is shown that stand-alone building-tied emergency diesel generators systems, even when two emergency diesel generators are used per building, cannot provide the reliability required to sustain critical loads for a grid outage lasting multiple days. Due to their network configuration and ability to share load, diesel generator-based microgrid configurations are estimated to have = 93% probability of powering all buildings for a 2-week outage there the individual building-tied emergency diesel generator architecture has a =20% probability. Microgrids do present other susceptibilities that are site specific and should be considered including vulnerabilities associated with the on-campus distribution system and cybersecurity.

backup power↗

Cyber‐physical system testbed for power system monitoring and wide‐area control verification

The electric power system is intrinsically a cyber‐physical system (CPS) with power flowing inthe physical system and information flowing in the cyber‐network. Testbeds arecrucial for understanding the cyber‐physical interactions and provideenvironments for prototyping novel applications. This study proposes afour‐layer architecture for CPS testbeds with emphases on communication networkemulation and networked physical components. A configurable software‐definednetwork is employed to bridge physical components with wide‐area applicationsfor closed‐loop control. In order to distribute physically coupled devices intomultiple software simulations, this study proposes a data broker setup based ona distributed messaging environment to achieve low‐latency data streaming. Thedecoupled design with data streaming allows for building testbed components asmodules and running them in a distributed manner. Case studies verify the databroker setup for low‐latency sensing and actuation, as well as the communicationemulation setup for the desired network latency. Also illustrated is a replayattack scenario using synchrophasors in the Western Electricity CoordinatingCouncil (WECC) 181‐bus system for demonstrating the closed‐loop cyber‐physicalsimulation capability of the testbed.

Cui, Hantao↗

Probabilistic simulation of quantum circuits using a deep-learning architecture

The fundamental question of how to best simulate quantum systems using conventional computational resources lies at the forefront of condensed matter and quantum computation. It impacts both our understanding of quantum materials and our ability to emulate quantum circuits. Here we present an exact formulation of quantum dynamics via factorized generalized measurements which maps quantum states to probability distributions with the advantage that local unitary dynamics and quantum channels map to local quasistochastic matrices. This representation provides a general framework for using state-of-the-art probabilistic models in machine learning for the simulation of quantum many-body dynamics. Using this framework, we have developed a practical algorithm to simulate quantum circuits using an attention network based on a powerful neural network ansatz responsible for the most recent breakthroughs in natural language processing. We demonstrate our approach by simulating circuits that build Greenberger-Horne-Zeilinger and linear graph states of up to 60 qubits, as well as a variational quantum eigensolver circuit for preparing the ground state of the transverse field Ising model on several system sizes. Our methodology constitutes a modern machine learning approach to the simulation of quantum physics with applicability both to quantum circuits as well as other quantum many-body systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Designing an Intrusion Detection for an Adjustable Speed Drive System Controlling a Critical Process

In this article, we address the cyber-security problem of industrial control systems (ICSs) when their sensor measurements may be compromised due to an attacker who has intercepted those measurements via a network. We introduce a general-purpose method “Dynamic Watermarking (DW)” to detect potential cyber-intrusions on speed sensor measurements within industrial control systems, which deploy an adjustable speed drive (ASD) to control a critical process. The DW method is injecting a random private low-amplitude signal with a zero mean Gaussian distribution, “watermark”, into one of the input phase voltages powering the ASD system. The watermark signal propagates through the system including pulse width modulation (PWM) power conversion stage and motor, then ultimately appears in the speed sensor measurements. By deploying two statistical DW tests with two proper thresholds, the system can detect potential cyber-intrusions or unobservable cyber-attacks such as replay attacks and false data injection attacks (FDIA). The DW method tested on a laboratory-scale ASD system experimentally to protect the system against cyber-intrusions. This system, powered by a commercial PWM drive operating at 208 V, 3-phase, and 3.7 kW, served as our experimental platform.

42 ENGINEERING↗

Modeling of a Networked Community Microgrid with High Solar Penetration Considering Control Dynamics of Inverter-Based Resources

Microgrids help facilitate the integration of renewable energy in distribution-level grids and increase the resilience of the electric grid to extreme weather, especially in rural areas. Compared to traditional microgrids, a networked microgrid leverages multiple grid-forming sources to form a potential meshed grid and is more flexible in operation. This paper demonstrates the simulation modeling of an actual networked microgrid located in Adjuntas, Puerto Rico. The model contains representations of power inverters that connect the battery energy storage systems and photovoltaic generation systems to the networked microgrid and is capable of simulating fast grid transients as well as long-term operation of the networked microgrid. The modeling technique for power inverters allows the time-efficient simulation of the microgrid with a minimal penalty on model accuracy.

Li, Dingrui↗

Grid-Forming Storage Networks: Analytical Characterization of Damping and Design Insights

Grid-forming storage resources are critical to the operation of power grids with high renewable penetration. Over the years, there has been considerable emphasis on understanding the benefits these inverter-based storage resources bring towards managing volatility and enhancing grid reliability but little is studied about the supplementary advantages latent in their operation. This paper investigates one such application in which we explore the impact of grid-forming distributed storage in damping low-frequency inter-area oscillations. We present a detailed analysis characterizing the impact of inverter-droop and storage size on the slower eigenvalues, highlighting potential design considerations for enhancing system stability.

Chatterjee, Kaustav [BATTELLE (PACIFIC NW LAB)] (O↗

Computation-Efficient Algorithm for Distributed Feedback Optimization of Distribution Grids

Feedback-based optimization algorithms use real-time measurements to update the optimal control for the underlying system which may not be fully identified. Recently, we have developed a distributed feedback-based algorithm [1] that avoids the requirement of fast communication between central computing and local actuator/sensor agents. This paper extends the work by greatly reducing the number of copies of variables involved in the distributed feedback-based algorithm, which results in faster convergence and lower communication requirement. The main idea is to leverage the specific structural properties of the admittance matrix for distribution systems with tree network topology. We also show the effectiveness of the proposed algorithm in simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep Reinforcement Learning Based Volt-VAR Optimization in Smart Distribution Systems

This paper develops a model-free volt-VAR optimization (VVO) algorithm via multi-agent deep reinforcement learning (DRL) in unbalanced distribution systems. This method is novel since we cast the VVO problem in distribution networks to an intelligent deep Q-network (DQN) framework, which avoids solving a specific optimization model directly when facing time-varying operating conditions in the systems. We consider statuses/ratios of switchable capacitors, voltage regulators, and smart inverters installed at distributed generators as the action variables of the agents. A delicately designed reward function guides these agents to interact with the distribution system, in the direction of reinforcing voltage regulation and power loss reduction simultaneously. The forward-backward sweep method for radial three-phase distribution systems provides accurate power flow results within a few iterations to the DRL environment. The proposed method realizes the dual goals for VVO. We test this algorithm on the unbalanced IEEE 13-bus and 123-bus systems. Numerical simulations validate the excellent performance of this method in voltage regulation and power loss reduction.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Network Optimization of the Electrosynthesis of Chemicals from CO2

Carbon dioxide electroreduction (ECO2R) is gaining attention due to its capacity to mitigate CO2 emissions while using electricity that would otherwise be curtailed. Its foreseeable industrial implementation requires of holistic methods to assess the technological and economic performance of ECO2R processes and integrate them in current chemical supply chains and power systems. Here, we combine techno-economic assessment and mathematical programming to find the optimal paths to electroreduce CO2 into valuable chemicals under variable electricity prices. The proposed approach is tested with a case study addressing the CO2 capture from flue gas or direct air and its electricity-powered reduction into carbon monoxide, formic acid or multi-carbon compounds. The results obtained demonstrate the ability of the framework to build ECO2R networks and provide operation profiles that respond to fluctuating electricity prices.

carbon dioxide↗