Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Molecular dynamics simulations of concentration-dependent defect production in Fe-Cr and Fe-Cu alloys

Molecular dynamics simulations are conducted to study the effects of alloying elements on the primary damage behaviors in three Fe-based ferritic alloy systems: (1) a Fe-Cr system in which the heat of mixing changes its sign with the Cr concentration; (2) a Fe-Cu system that has a positive heat of mixing; and (3) an ideal but artificial Fe-Cr system that has a zero heat of mixing, which is used as a reference system to investigate solute interstitial formation based on probability. It is found that in these alloys, the solute type and concentration do not have a significant effect on the total number of surviving Frenkel pairs. However, the fraction of solute interstitials has distinct behaviors. In Fe-Cr, the Cr interstitial fraction is much higher than the Cr solute concentration and the Cr interstitial production efficiency decreases with the increasing Cr concentration. By contrast, in Fe-Cu, Cu interstitials are barely produced. In the ideal alloy, the solute interstitial fraction is close to the solute concentration. The defect formation energies in both dilute and concentrated alloys, interstitial binding energies, liquid diffusivities of Fe and solute atoms, and heat of mixing have been calculated for both Fe-Cr and Fe-Cu alloys. Among them, we find that the relative thermodynamic stability between Fe self-interstitials and solute interstitials plays the most important role in the solute interstitial production behaviors. The decrease of Cr interstitial production efficiency with increasing Cr concentration can be explained by the probability distribution functions of solute interstitial formation energy in concentrated alloys.

Zhang, Yaxuan↗

Economic Assessment of Hydrogen Technologies Participating in California Electricity Markets

As the electric sector evolves and increasing amounts of variable renewable generation are installed on the system, there are greater needs for system flexibility and sufficient capacity, and greater concern for overgeneration from renewable sources not well matched in time with electric loads. Hydrogen systems have the potential to support the grid in each of these areas. However, limited information is available about the economic competitiveness of hydrogen system configurations. This paper quantifies the value for hydrogen energy storage and demand response systems to participate in select California wholesale electricity markets using 2012 data. For hydrogen systems and conventional storage systems (e.g., pumped hydro, batteries), the yearly revenues from energy, ancillary service, and capacity markets are compared to the yearly cost to establish economic competitiveness. Hydrogen systems can present a positive value proposition for current markets. Three main findings include: (1) For hydrogen systems participating in California electricity markets, producing and selling hydrogen was found to be much more valuable than producing and storing hydrogen to later produce electricity; therefore systems should focus on producing and selling hydrogen and opportunistically providing ancillary services and arbitrage. (2) Tighter integration with electricity markets generates greater revenues (i.e., systems that participate in multiple markets receive the highest revenue). (3) More storage capacity, in excess of what is required to provide diurnal shifting, does not increase competitiveness in current California wholesale energy markets. As more variable renewable generation is installed, the importance of long duration storage may become apparent in the energy price or through additional markets, but currently, there is not a sufficiently large price differential between days to generate enough revenue to offset the cost of additional storage. Future work will involve expanding to consider later year data and multiple regions to establish more generalized results.

25 ENERGY STORAGE↗

Coaxial coupling scheme for fundamental and higher order modes in superconducting cavities

Higher Order Modes generated by a particle beam passing through a superconducting accelerating cavity have to be damped to avoid beam instabilities. A coaxial coupler located in the beam pipes of the cavities provides for better propagation of HOMs and strong damping in appropriate HOM dampers. The whole damping device can be designed as a detachable system. If appropriately dimensioned, the RF currents can be minimized at the flange position. Additionally, the coaxial system also provides efficient coupling of fundamental mode RF power into the superconducting cavity. Compared to presently available solutions for HOM damping, this scheme provides for several advantages: stronger HOM damping, attachable solution, and exchangeability of the HOM damping device on a cavity, less complexity of the superconducting cavity, possible cost advantages. This contribution discusses modeling, which lead to an optimized layout of a cavity-coupler system and describes results from the room temperature and first cryogenic temperature measurements .

Sekutowicz, Jacek↗

Coaxial coupling scheme for fundamental and higher order modes in superconducting cavities

Higher Order Modes generated by a particle beam passing through a superconducting accelerating cavity have to be damped to avoid beam instabilities. A coaxial coupler located in the beam pipes of the cavities provides for better propagation of HOMs and strong damping in appropriate HOM dampers. The whole damping device can be designed as a detachable system. If appropriately dimensioned, the RF currents can be minimized at the flange position. Additionally, the coaxial system also provides efficient coupling of fundamental mode RF power into the superconducting cavity. Compared to presently available solutions for HOM damping, this scheme provides for several advantages: stronger HOM damping, attachable solution, and exchangeability of the HOM damping device on a cavity, less complexity of the superconducting cavity, possible cost advantages. This contribution discusses modeling, which lead to an optimized layout of a cavity-coupler system and describes results from the room temperat

43 PARTICLE ACCELERATORS↗

Real-time Awake Animal Motion Tracking System for SPECT Imaging

Enhancements have been made in the development of a real-time optical pose measurement and tracking system that provides 3D position and orientation data for a single photon emission computed tomography (SPECT) imaging system for awake, unanesthetized, unrestrained small animals. Three optical cameras with infrared (IR) illumination view the head movements of an animal enclosed in a transparent burrow. Markers placed on the head provide landmark points for image segmentation. Strobed IR LED s are synchronized to the cameras and illuminate the markers to prevent motion blur for each set of images. The system using the three cameras automatically segments the markers, detects missing data, rejects false reflections, performs trinocular marker correspondence, and calculates the 3D pose of the animal s head. Improvements have been made in methods for segmentation, tracking, and 3D calculation to give higher speed and more accurate measurements during a scan. The optical hardware has been installed within a Siemens MicroCAT II small animal scanner at Johns Hopkins without requiring functional changes to the scanner operation. The system has undergone testing using both phantoms and live mice and has been characterized in terms of speed, accuracy, robustness, and reliability. Experimental data showing these motion tracking results are given.

59 BASIC BIOLOGICAL SCIENCES↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Study of ITER plasma position reflectometer using a two-dimensional full-wave finite-difference time domain code

The EU will supply the plasma position reflectometer for ITER. The system will have channels located at different poloidal positions, some of them obliquely viewing a plasma which has a poloidal density divergence and curvature, both adverse conditions for profile measurements. To understand the impact of such topology in the reconstruction of density profiles a full-wave two-dimensional finite-difference time domain O-mode code with the capability for frequency sweep was used. Simulations show that the reconstructed density profiles still meet the ITER radial accuracy specifications for plasma position (1 cm), except for the highest densities. Other adverse effects such as multireflections induced by the blanket, density fluctuations, and MHD activity were considered and a first understanding on their impact obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection efficiency measurement and operational tests of the X-Arapuca for the first module of DUNE far detector

The Deep Underground Neutrino Experiment (DUNE) is a dual-site experiment for long-baseline neutrino oscillation studies, able to resolve the neutrino mass hierarchy and measure δ$_{CP}$. DUNE will also have sensitivity to supernova neutrinos and to processes beyond the Standard Model, such as nucleon decay searches. The Far Detector (FD) will consist of four liquid argon TPC (17.5 kt total mass) with systems for the detection of charge and scintillation light produced by an ionization event. The charge detection system permits both calorimetry and position determination. In addition, the photon-detection system (PDS) enhances the detector capabilities for all DUNE physics drivers. The PDS of the first FD module consists of light collector modules placed in the inactive space between the innermost wire planes of the TPC anode. The light collectors, the so-called X-ARAPUCAS, are functionally a light trap that captures wavelength-shifted photons inside boxes with highly reflective internal surfaces where they are guided to Silicon Photo-multipliers (SiPM) by wavelength-shifting (WLS) bars. Functionality and operational tests of the X-ARAPUCAS to be installed in ProtoDUNE-SP phase II (FD DUNE prototype at the scale 1:20), as well as the measurement of their absolute detection efficiency is reported in this publication.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

What Questions Would a Systems Engineer Ask to Assess Systems Engineering Models as Credible

Digital Systems Engineering strategies typically call for digital Systems Engineering models to be retained in repositories and certified as an authoritative source of truth (enabling model reuse, qualification, and collaboration). In order for digital Systems Engineering models to be certified as authoritative (credible), they need to be assessed - verified and validated - and with the amount of uncertainty in the model quantified (consider reusing someone else's model without knowing the author). Due to this increasing model complexity, the authors assert that traditional human-based methods for validating, verifying, and uncertainty quantification - such as human-based peer-review sessions - cannot sufficiently establish that a digital Systems Engineering model of a complex system is credible. Digital Systems Engineering models of complex systems can contain millions of nodes and edges. The authors assert that this level of detail is beyond the ability of any group of humans - even working for weeks at a time - to discern and catch every minor model infraction. In contrast, computers are highly effective at discerning infractions with massive amounts of information. The authors suggest that a better approach might be to focus the humans at what model patterns should be assessed and enable the computer to assess the massive details in accordance with those patterns - by running through perhaps 100,000 test loops. In anticipation of future projects to implement and automate the assessment of models at Sandia National Laboratories, a study was initiated to elicit input from a group of 25 Systems Engineering experts. The authors positioning query began with - 'What questions would a Systems Engineer ask to assess Systems Engineering models for credibility?" This report documents the results of that survey.

42 ENGINEERING↗

Nonlinear waves in an array of zigzag waveguides with alternating positive and negative refractive indices

Interaction of coupled waves propagating in a system of waveguides with alternating positive and negative refractive indices is studied theoretically. The zigzag configuration of the waveguides in the array allows communication not only between the nearest neighbours, but also with the waveguides beyond them. It is shown that the spectrum of linear waves in such a waveguide system has a bandgap. Partial solutions are found to the system of coupled waves corresponding to a stationary electromagnetic field pulse that propagates along the array of tunnel-coupled waveguides as a whole. Investigation of the interaction of nonlinear solitary waves has demonstrated numerically the stability of their relatively weak disturbances and collisions with each other. (nanogradient dielectric coatings and metamaterials)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fielding the NIF Cryogenic Ignition Target

The United States Department of Energy has embarked on a campaign to conduct credible fusion ignition experiments on the National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory in 2010. The target assembly specified for this campaign requires the formation of a deuterium/tritium (DT) fuel ice layer on the inside of a 2 millimeter diameter capsule positioned at the center of a 9 millimeter long by 5 millimeter diameter cylinder, called a hohlraum. The ice layer requires micrometer level accuracy and must be formed and maintained at temperatures below 19 K. At NIF shot time, the target must be positioned at the center of the NIF 10 meter diameter target chamber, aligned to the laser beam lines and held stable to less than 7 micrometers rms. We have completed the final design and are integrating the systems necessary to create, characterize and field the cryogenic target for ignition experiments. These designs, with emphasis on the challenges of fielding a precision cryogenic positioning system will be presented.

42 ENGINEERING↗

Mu2e Solenoid Field Mapping System Design

The Mu2e experiment at Fermilab plans to search for charged-lepton flavor violation by looking for neutrino-less muon to electron conversion in the field of the nucleus. A complex solenoid system and precise knowledge of its magnetic field play a major role in the experimental approach Mu2e has chosen. It is essential to map the solenoid field up to 10 -4 accuracy. This article describes the design of the Field Mapping System Mu2e will use to measure the magnetic field. Two different mechanical mapper systems, a survey based position determination of the in-house calibrated 3D Hall probes, a motion control system, and a data acquisition and readout system are presented.

43 PARTICLE ACCELERATORS↗

Active optics null test system based on a liquid crystal programmable spatial light modulator

We present an active null test system adapted to test lenses and wavefronts with complex shapes and strong local deformations. This system provides greater flexibility than conventional static null tests that match only a precisely positioned, individual wavefront. The system is based on a cylindrical Shack-Hartmann wavefront sensor, a commercial liquid crystal programmable phase modulator (PPM), which acts as the active null corrector, enabling the compensation of large strokes with high fidelity in a single iteration, and a spatial filter to remove unmodulated light when steep phase changes are compensated. We have evaluated the PPM's phase response at 635 nm and checked its performance by measuring its capability to generate different amounts of defocus aberration, finding root mean squared errors below {lambda}/18 for spherical wavefronts with peak-to-valley heights of up to 78.7{lambda}, which stands as the limit from which diffractive artifacts created by the PPM have been found to be critical under no spatial filtering. Results of a null test for a complex lens (an ophthalmic customized progressive addition lens) are presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NRC technical basis for evaluation of its position on protection against common cause failure in digital systems used in nuclear power plants - 378

Digital technology has advantages over analog systems, including automated monitoring and alerts for standby safety functions, and predictive algorithms to maintain critical safety systems. Additionally, digital technology generally has higher reliability and can be designed to reduce single point vulnerabilities. For these reasons many nuclear plants have applied digital technology to safety and non-safety related applications, including reactor protection system, feedwater and turbine controls, etc. with a corresponding significant improvement in trip reduction. Nonetheless, digital instrumentation and control (I and C) systems also present potential new vulnerabilities that need to be assessed, including potential failures due to increased complexity of digital systems, the introduction of unique failure modes due to software (including software common cause failure (CCF)), and limited operating history of digital systems in nuclear safety related applications compared to analog systems. The fact that software is intangible means that common methods, such as analysis or testing, used for detecting CCF may not be effective when applied to software. Consequently, digital technology is perceived to pose a potential risk from the introduction of undetected systematic faults that could result in CCF. Despite the I and C system upgrades and modifications performed to date, the U.S. Nuclear Regulatory Commission (NRC) and industry stakeholders have identified the need to modernize the regulatory infrastructure to efficiently address risks associated with the use of digital technology for nuclear safety applications and address regulatory uncertainties. The NRC's current position on CCF is guided by the staff requirements memorandum (SRM) on SECY 93-087. The SRM provides specific acceptance criteria for the evaluation of CCF, which the staff implemented in the Branch Technical Position (BTP) 7-19. However, industry stakeholders have proposed using methods to characterize the likelihood of software CCF and eliminate it from further consideration in a defense-in-depth and diversity analysis. The NRC's current position does not consider these alternatives, and thus corresponding acceptance criteria is not currently available. The work discussed in this paper assesses the underlying technical basis associated with CCF, provides technical support for updating the NRC position and considers proposed methods for addressing potential CCF in digital systems while enhancing efficiency, clarity, and confidence. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Linac-based on-board imaging feasibility and the dosimetric consequences of head roll in head-and-neck IMRT plans

Kilovoltage imaging systems on linear accelerators are used for patient localization in many clinics. The purpose of this work is to assess on-board imaging (OBI) detection of systematic setup errors and in particular, the dosimetric consequences of undetected head roll in head-and-neck intensity modulated radiation therapy (IMRT) plans when using these systems. The system used in this study was the Trilogy linear accelerator and associated software (Varian Medical Systems, Palo Alto, CA). Accuracy of OBI localization was evaluated using an anthropomorphic head phantom. The head phantom is rigidly attached to a specially designed positioning device with 5 deg. of freedom, 3 translational and 2 rotational in the axial and coronal planes. Simulated setup errors were 3 deg. and 5 deg. rotations in the axial plane and displacements of 5 mm in the left-right, anterior-posterior, and superior-inferior directions. The coordinates set by the positioning device were compared with the coordinates obtained as measured by using the image matching tools of paired 2-dimensional (2D) orthogonal image matching, and 3D cone-beam computed tomography (CT) volume matching. In addition, 6 physician-approved IMRT plans of nasopharynx and tonsil carcinoma were recalculated to evaluate the impact of undetected 3 deg. and 5 deg. head roll. Application of cone-beam CT (CBCT) for patient localization was superior to 2D matching techniques for detecting rotational setup errors. The use of CBCT allowed the determination of translational errors to within 0.5 mm, whereas kV planar was within 1 to 2 mm. Head roll in the axial plane was not easily detected with orthogonal image sets. Compared to the IMRT plans with no head roll, dose-volume histogram analysis demonstrated an average increase in the maximal spinal cord dose of 3.1% and 6.4% for 3 deg. and 5 deg. angles of rotation, respectively. Dose to the contralateral parotid was unchanged with 3 deg. roll and increased by 2.7% with 5 deg. roll. The results of this study show that volumetric setup verification using CBCT can improve bony anatomy setup detection to millimeter accuracy, and is a reliable method to detect head roll. However, the magnitude of possible dose errors due to undetected head roll suggests that CBCT does not need to be performed on a daily basis but rather weekly or bi-weekly to ensure fidelity of the head position with the immobilization system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Spot characteristic stability for proton pencil beam scanning

Purpose: The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. Methods: A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0–226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to the beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. Results: Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. Conclusions: For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New printed circuit boards magnetic coils in the vacuum vessel of J-TEXT tokamak for position measurement

Four sets of magnetic diagnostic coils, which are printed on machinable ceramic printed circuit boards (PCB), are designed, fabricated, installed, and tested in the Joint Texas Experimental Tokamak (J-TEXT) vacuum vessel for detecting the plasma radial and vertical displacements relative to the geometric center of the vacuum vessel in Ohmic discharges. Each coordinate is determined by a pair of variable cross-section Rogowski and saddle coils, which measure the tangential and normal magnetic fields (relative to the coil surface). These coils are suitable for mass production and offer advantages in vacuum compatibility and temperature tolerance that are important for J-TEXT. Position measurements using PCB coils are compared with those from soft x-ray image system and match the position well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precessing Jet and Large Dust Grains in the V380 Ori NE Star-forming Region

The V380 Ori NE bipolar outflow was imaged in the SiO and CO J=1→0 lines, and dense cores in L1641 were observed in the 2.0–0.89 mm continuum. The highly collimated SiO jet shows point-symmetric oscillation patterns in both position and velocity, which suggests that the jet axis is precessing and the driving source may belong to a non-coplanar binary system. By considering the position and velocity variabilities together, accurate jet parameters were derived. The protostellar system is viewed nearly edge-on, and the jet has a flow speed of ∼35 km s{sup −1} and a precession period of ∼1600 years. The CO outflow length gives a dynamical timescale of ∼6300 years, and the protostar must be extremely young. The inferred binary separation of 6–70 au implies that this protobinary system may have been formed through the disk instability process. The continuum spectra of L1641 dense cores indicate that the emission comes from dust, and the fits with modified blackbody functions give emissivity power indices of β = 0.3–2.2. The emissivity index shows a positive correlation with the molecular line width, but no strong correlation with bolometric luminosity or temperature. V380 Ori NE has a particularly low value of β = 0.3, which tentatively suggests the presence of millimeter-sized dust grains. Because the dust growth takes millions of years, much longer than the protostellar age, this core may have produced large grains in the starless core stage. HH 34 MMS and HH 147 MMS also have low emissivity indices.

79 ASTRONOMY AND ASTROPHYSICS↗