Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

The levelized cost of energy for distributed PV : a parametric study.

The maturation of distributed solar PV as an energy source requires that the technology no longer compete on module efficiency and manufacturing cost ($/Wp) alone. Solar PV must yield sufficient energy (kWh) at a competitive cost (c/kWh) to justify its system investment and ongoing maintenance costs. These metrics vary as a function of system design and interactions between parameters, such as efficiency and area-related installation costs. The calculation of levelized cost of energy includes energy production and costs throughout the life of the system. The life of the system and its components, the rate at which performance degrades, and operation and maintenance requirements all affect the cost of energy. Cost of energy is also affected by project financing and incentives. In this paper, the impact of changes in parameters such as efficiency and in assumptions about operating and maintenance costs, degradation rate and system life, system design, and financing will be examined in the context of levelized cost of energy.

14 SOLAR ENERGY↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

A Cooperative Multi-Agent Deep Reinforcement Learning Framework for Real-Time Residential Load Scheduling

Internet-of-Things (IoT) enabled monitoring and control capabilities are enabling increasing numbers of household users with controllable loads to actively participate in smart grid energy management. Realizing an efficient real-time energy management system that takes advantage of these developments requires novel techniques for managing the increased complexity of the control action space in resolving multiple challenges such as the uncertainty in energy prices and renewable energy output along with the need to satisy physical grid constraints such as transformer capacity. Addressing these challenges, we develop a multi-household energy management framework for residential units connected to the same transformer and containing DERs such as PV, ESS and controllable loads. The goal of our framework is to schedule controllable household appliances and ESS such that the cost of procuring electricity from the utility over a horizon is minimized while physical grid constraints are satisfied at each scheduling step. Traditional energy management frameworks either perform global optimization to satisfy grid constraints but suffer from high computational complexity (for example Integer Program, Mixed Integer Programming frameworks and centralized reinforcement learning) or perform decentralized real-time energy management without satisfying global grid constraints (for example multi-agent reinforcement learning with no cooperation). In contrast, we propose a cooperative multiagent reinforcement learning (MARL) framework that i) operates in real-time, and ii) performs explicit collaboration to satisfy global grid constraints. The novelty in our framework is two fold. Firstly, our framework trains multiple independent learners (IL) for each household in parallel using historical data and performs real-time inferencing of control actions using the most recent system state. Secondly, our framework contains a low complexity knapsack based cooperation agent which combines the outputs of ILs to minimize cost while satisfying grid constraints. Simulation results show that our cooperative MARL approach achieves significant cost improvement over centralized reinforcement learning and day-ahead planning baselines. Moreover, our approach strictly satisfies physical constraints with no apriori knowledge of system dynamics while the baseline approaches have occasional violations. We also measure the training and inference time by ranging the number of households from 1 to 25. Results show that our cooperative MARL approach scales best among various approaches.

14 SOLAR ENERGY↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Bulk‐Heterojunction Electrocatalysts in Confined Geometry Boosting Stable, Acid/Alkaline‐Universal Water Electrolysis

Abstract Alkaline water splitting electrocatalysts have been studied for decades; however, many difficulties remain for commercialization, such as sluggish hydrogen evolution reaction (HER) kinetics and poor catalytic stability. Herein, by mimicking the bulk‐heterojunction morphology of conventional organic solar cells, a uniform 10 nm scale nanocube is reported that consists of subnanometer‐scale heterointerfaces between transition metal phosphides and oxides, which serves as an alkaline water splitting electrocatalyst; showing great performance and stability toward HER and oxygen evolution reaction (OER). Interestingly, the nanocube electrocatalyst reveals acid/alkaline independency from the synergistic effect of electrochemical HER (cobalt phosphide) and thermochemical water dissociation (cobalt oxide). From the spray coating process, nanocube electrocatalyst spreads uniformly on large scale (≈6.6 × 5.6 cm 2 ) and is applied to alkaline water electrolyzers, stably delivering 600 mA cm −2 current for >100 h. The photovoltaic‐electrochemical (PV‐EC) system, including silicon PV cells, achieves 11.5% solar‐to‐hydrogen (STH) efficiency stably for >100 h.

Chemistry↗

Improvements to PVWatts for Fixed and One-Axis Tracking Systems

This work presents improvements to the widely used NREL PVWatts photovoltaic system energy model to improve modeling accuracy for typical fixed and one axis system designs. The aim is to calculate losses in the PV system assuming typical modern system design practices, while maintaining simplicity by keeping the required set of input parameters small. These improvements allow users to more credibly and quickly evaluate competing system designs in early stage feasibility. Common submodels for module cover, spectral, snow, tracker, transformer, plant controller, and self-shading losses, in addition to a bifacial gain option, are incorporated into the PVWatts model, and are shown to improve PVWatts' system performance prediction capabilities without major impact to ease of use. We anticipate including these improvements in a future release of NREL's open source PVWatts code, and some of the features may become available in the System Advisor Model (SAM) desktop software as well as the popular PVWatts web application.

14 SOLAR ENERGY↗

The Impacts of Changes to Nevada’s Net Metering Policy on the Financial Performance and Adoption of Distributed Photovoltaics

Net energy metering (NEM) is a billing mechanism that has historically compensated owners of distributed generation systems at retail rates for any electricity that they export back to the grid rather than consume on-site. NEM can significantly enhance the financial performance of distributed generation systems from the owner’s perspective. The following analysis was designed to illustrate the potential impact of NEM policy and tariff changes implemented in early 2016 in Nevada.

14 SOLAR ENERGY↗

Distributed Wind Energy Futures Study

To better understand distributed wind opportunities in the United States, researchers at the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory explored cost, performance, and valuation benchmarks necessary for distributed wind to achieve widespread commercial viability in the United States by 2035. Building on DOE's prior benchmark report "Assessing the Future of Distributed Wind: Opportunities for Behind-the-Meter Projects", the new Distributed Wind Futures Study employs higher-resolution data and new modeling techniques to highlight geographic trends in technical and economic potential and to compare the cost and performance of distribution-connected, megawatt-scale wind applications (referred to as "front-of-the-meter" applications) and behind-the-meter systems, thereby informing the case for investment. The report identifies the best locations and sectors for behind-the-meter and front-of-the-meter applications and provides data to inform the trade-offs consumers face when deciding between distributed wind and solar photovoltaic (PV).

17 WIND ENERGY↗

Distributed Wind Energy Futures Study [Slides]

To better understand distributed wind opportunities in the United States, researchers at the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory explored cost, performance, and valuation benchmarks necessary for distributed wind to achieve widespread commercial viability in the United States by 2035. Building on DOE's prior benchmark report "Assessing the Future of Distributed Wind: Opportunities for Behind-the-Meter Projects", the new Distributed Wind Futures Study employs higher-resolution data and new modeling techniques to highlight geographic trends in technical and economic potential and to compare the cost and performance of distribution-connected, megawatt-scale wind applications (referred to as "front-of-the-meter" applications) and behind-the-meter systems, thereby informing the case for investment. The report identifies the best locations and sectors for behind-the-meter and front-of-the-meter applications and provides data to inform the trade-offs consumers face when deciding between distributed wind and solar photovoltaic (PV).

17 WIND ENERGY↗

International Photovoltaic Modeling Intercomparison [Slides]

Irradiance transposition models seem to perform well, except the Isotropic with -11.25 W/m 2 underestimation. Most temperature models could not capture behavior when ΔΤ between module and ambient is negative. Uncertainties due to derate factors: modelers overbudgeted resulting in significant power underestimation; maybe ~10% is appropriate for commercial systems but not lab-scale? Most software and models cluster together showing good reproducibility among participants. Modeler’s skills seem to be more important than the PV model itself (flat efficiency with irradiance, positive power temperature coefficients, etc.). Results and best practices will be communicated in a journal article.

14 SOLAR ENERGY↗

Development of Prototypical District-Scale Models

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANopt platform workflows. A case study was performed to demonstrate the model application.

building energy modeling↗

Investigation of Correlation between Field Performance and Indoor Acceleration Measurements of Potential Induced Degradation (PID) for c-Si PV Modules

The correlation between outdoor field testing and indoor chamber measurement for potential-induced degradation in crystalline silicon PV modules is unclear. The motivation of this work is to build up a direct comparison and investigate the correlation between indoor and outdoor performance. First of all, four PID indoor tests were defined from basic to premium, based on the difficulty of the test. Six groups of modules were designed and fabricated in Trina Solar, with different grades of PID resistance from weak to strong. The outdoor field test systems were built in three different climates: tropical, subtropical, and semi-arid climates in Singapore, Changzhou (China) and Golden (CO, USA) respectively, in a collaborative testing campaign involving Trina, SERIS and NREL. The system in Golden has been on-sun for more than 13 months where <4% power loss which includes PID and other reliability losses was detected and power loss of <2% is shown for all six groups of modules after 21 weeks in the field in the subtropical climate in Changzhou. However, PID of 23% was observed after 18 weeks in Singapore for the most PID-susceptible module, while the other PID module types showed degradation of only less than 5%.

14 SOLAR ENERGY↗

Improvements to PVWatts for Fixed and One-Axis Tracking Systems: Preprint

This work presents improvements to the widely used NREL PVWatts photovoltaic system energy model to improve modeling accuracy for typical fixed and one axis system designs. The aim is to calculate losses in the PV system assuming typical modern system design assumptions, while maintaining simplicity by keeping the required set of input parameters small. These improvements allow users to more credibly and quickly evaluate competing system designs in early stage feasibility. Common submodels for module cover, spectral, snow, tracker, transformer, plant controller, and self-shading losses, in addition to a bifacial gain option, are incorporated into the PVWatts model, and are shown to improve PVWatts' system performance prediction capabilities without major impact to ease of use.

14 SOLAR ENERGY↗

Development of Prototypical District-Scale Models: Preprint

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANoptTM platform workflows. A case study was performed to demonstrate the model application.

district↗

Tailoring automatic exposure control toward constant detectability in digital mammography

Purpose: The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. Methods: The default “OPDOSE” AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d′), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (T{sub t}) in the European guidelines for the 0.1 mm diameter disc (i.e., T{sub t} ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (T{sub t}), calculated detectability (d′), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. Results: The default OPDOSE AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d′ 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d′), respectively. Threshold gold thickness (0.1 mm diameter disc) for the default AEC mode in the homogeneous background increased by 62% in going from 20 to 70 mm PMMA thickness; in the structured background, the increase was 39%. Implementation of the modified mode entailed an increase in mAs at PMMA thicknesses >40 mm; the modified AEC held threshold gold thickness constant above 40 mm PMMA with a maximum deviation of 5% in the homogeneous background and 3% in structured background. SDNR was also held constant with a maximum deviation of 4% and 2% for the homogeneous and the structured background, respectively. These results were obtained with an increase of MGD between 15% and 73% going from 40 to 70 mm PMMA thickness. Conclusions: This work has proposed and implemented a modified AEC mode, tailored toward constant detectability at larger breast thickness, i.e., above 40 mm PMMA equivalent. The desired improvement in object detectability could be obtained while maintaining MGD within the European guidelines achievable dose limit. (A study designed to verify the performance of the modified mode using more clinically realistic data is currently underway.)

60 APPLIED LIFE SCIENCES↗

Integrated and Optimized Energy-Efficient Construction Package for a Community of Production Homes in the Mixed-Humid Climate

This research high performance home analyzes how a set of advanced technologies can be integrated into a durable and energy-efficient house in the mixed-humid climate while remaining affordable to homeowners. The technical solutions documented in this report are the cornerstone of the builder's entire business model based on delivering high-performance homes on a production basis as a standard product offering to all price segments of the residential market. Home Innovation Research Labs partnered with production builder Nexus EnergyHomes (CZ 4) and they plan to adopt the successful components of the energy solution package for all 55 homes in the community. The research objective was to optimize the builder's energy solution package based on energy performance and construction costs. All of the major construction features, including envelope upgrades, space conditioning system, hot water system, and solar electric system were analyzed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient Stability Assessment of Multi-Machine Multi-Converter Power Systems

Transmission faults caused by recent wildfires in California induced the disconnection of utility-scale converters in photovoltaic (PV) power plants. Postmortem investigations reported that tripping commands were caused by phase-locked loops (PLLs) and dc-side dynamics, which are typically unmodeled in transient stability studies. Since existing simulation packages rely on simplified models that neglect these dynamics, they have a limited capability to predict converter behavior during faults. To address this shortcoming, we set forth a positive-sequence model for PV power plants that is derived from physics and controls first principles. As seen on utility-scale three-phase converters, the model includes PLLs, dc-side dynamics, and closed-loop controllers. Instances of the developed model are integrated into illustrative power systems containing also conventional generators. Numerical simulations of the obtained multi-machine multi-converter power systems are assessed via a suitable set of stability and performance metrics.

14 SOLAR ENERGY↗

NREL RSF Measured Data 2011

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance. This submission includes the Measured Energy Data from the RSF Systems Model. The data includes a csv with measured data from NREL's Research and Support Facility (RSF) for 2011. The dataset contains hourly data for: Total Cooling (kW)- Total Heating (kW)- Total Mechanical (kW)- Total Lighting (kW)- Total Plug Loads (kW)- Total Data Center (kW)- Total Building (kW)- PV (kW)- Building Net (kW). Energy Model data and Weather data related to the RSF Systems Model can be found in the "Related Datasets" section of this submission.

2011↗