Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PUMPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Scenario Documentation: Laboratory-Informed Modeling of Standard Performance Heat Pump Rooftop Units

This measure scenario replaces gas and electric resistance RTUs in the U.S. commercial building stock with standard efficiency commercial off the shelf heat pump rooftop units. This study uses performance data informed by NREL laboratory testing of a standard efficiency 7.5-ton heat pump RTU. This is the key distinction between this measure scenario and a similar ComStock measure scenario - Standard Performance Heat Pump Rooftop Units - that uses published manufacturer data tables to inform performance. These two scenarios are compared in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

99 GENERAL AND MISCELLANEOUS↗

Performance of Gas-Engine Driven Heat Pump Unit

Air-conditioning (cooling) for buildings is the single largest use of electricity in the United States (U.S.). This drives summer peak electric demand in much of the U.S. Improved air-conditioning technology thus has the greatest potential impact on the electric grid compared to other technologies that use electricity. Thermally-activated technologies (TAT), such as natural gas engine-driven heat pumps (GHP), can provide overall peak load reduction and electric grid relief for summer peak demand. GHP offers an attractive opportunity for commercial building owners to reduce electric demand charges and operating expenses. Engine-driven systems have several potential advantages over conventional single-speed or single-capacity electric motor-driven units. Among them are variable speed operation, high part load efficiency, high temperature waste heat recovery from the engine, and reduced annual operating costs (SCGC 1998). Although gas engine-driven systems have been in use since the 1960s, current research is resulting in better performance, lower maintenance requirements, and longer operating lifetimes. Gas engine-driven systems are typically more expensive to purchase than comparable electric motor-driven systems, but they typically cost less to operate, especially for commercial building applications. Operating cost savings for commercial applications are primarily driven by electric demand charges. GHP operating costs are dominated by fuel costs, but also include maintenance costs. The reliability of gas cooling equipment has improved in the last few years and maintenance requirements have decreased (SCGC 1998, Yahagi et al. 2006). Another advantage of the GHP over electric motor-driven is the ability to use the heat rejected from the engine during heating operation. The recovered heat can be used to supplement the vapor compression cycle during heating or to supply other process loads, such as water heating. The use of the engine waste heat results in greater operating efficiency compared to conventional electric motor-driven units (SCGC 1998). In Japan, many hundreds of thousands of natural gas-driven heat pumps have been sold (typically 40,000 systems annually) (Yahagi et al. 2006). The goal of this program is to develop dependable and energy efficient GHPs suitable for U.S. commercial rooftop applications (the single largest commercial product segment). This study describes the laboratory performance evaluation of an integrated 10-ton GHP rooftop unit (a 900cc Daihatsu-Aisin natural gas engine) which uses R410A as the refrigerant (GEDAC No.23). ORNL Thermally-Activated Heat Pump (TAHP) Environmental Chambers were used to evaluate this unit in a controlled laboratory environment.

03 NATURAL GAS↗

Eliminating Liquid Entrapment between the Teeth of a Gear-Driven Pump

Entrapment of liquid in the intertooth space of a gear-driven pump is considered. A method is proposed for its elimination. The influence of annular channels on the volume losses in the pump is shown. The decrease in pump efficiency in the presence of annular channels is assessed.

42 ENGINEERING↗

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Experimental Protocol for Femtosecond NIR/UV - XUV Pump-Probe Experiments with Free-Electron Lasers

This protocol describes key steps in performing and analyzing femtosecond pump-probe experiments that combine a femtosecond optical laser with a free-electron laser. This includes methods to establish the spatial and temporal overlap between the optical and free-electron laser pulses during the experiment, as well as important aspects of the data analysis, such as corrections for arrival time jitter, which are necessary to obtain high-quality pump-probe data sets with the best possible temporal resolution. These methods are demonstrated for an exemplary experiment performed at the FLASH (Free-electron LASer Hamburg) free-electron laser in order to study ultrafast photochemistry in gas-phase molecules by means of velocity map ion imaging. However, most of the strategies are also applicable to similar pump-probe experiments using other targets or other experimental techniques.

47 OTHER INSTRUMENTATION↗

BABCOCK–LEIGHTON SOLAR DYNAMO: THE ROLE OF DOWNWARD PUMPING AND THE EQUATORWARD PROPAGATION OF ACTIVITY

The key elements of the Babcock–Leighton dynamos are the generation of poloidal field through decay and the dispersal of tilted bipolar active regions and the generation of toroidal field through the observed differential rotation. These models are traditionally known as flux transport dynamo models as the equatorward propagations of the butterfly wings in these models are produced due to an equatorward flow at the bottom of the convection zone. Here we investigate the role of downward magnetic pumping near the surface using a kinematic Babcock–Leighton model. We find that the pumping causes the poloidal field to become predominately radial in the near-surface shear layer, which allows the negative radial shear to effectively act on the radial field to produce a toroidal field. We observe a clear equatorward migration of the toroidal field at low latitudes as a consequence of the dynamo wave even when there is no meridional flow in the deep convection zone. Both the dynamo wave and the flux transport type solutions are thus able to reproduce some of the observed features of the solar cycle including the 11-year periodicity. The main difference between the two types of solutions is the strength of the Babcock–Leighton source required to produce the dynamo action. A second consequence of the magnetic pumping is that it suppresses the diffusion of fields through the surface, which helps to allow an 11-year cycle at (moderately) larger values of magnetic diffusivity than have previously been used.

79 ASTRONOMY AND ASTROPHYSICS↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗

Bleed Cycle Propellant Pumping in a Gas-Core Nuclear Rocket Engine System

The performance of ideal and real staged primary propellant pumps and bleed-powered turbines was calculated for gas-core nuclear rocket engines over a range of operating pressures from 500 to 5000 atm. This study showed that for a required engine operating pressure of 1000 atm the pump work was about 0.8 hp/(lb/sec), the specific impulse penalty resulting from the turbine propellant bleed flow as about 10 percent; and the heat required to preheat the propellant was about 7.8 MW/(lb/sec). For a specific impulse above 2400 sec, there is an excess of energy available in the moderator due to the gamma and neutron heating that occurs there. Possible alternative pumping cycles are the Rankine or Brayton cycles.

Gas-core↗

Design of Accumulators and Liquid/Gas Charging of Single Phase Mechanically Pumped Fluid Loop Heat Rejection Systems

For single phase mechanically pumped fluid loops used for thermal control of spacecraft, a gas charged accumulator is typically used to modulate pressures within the loop. This is needed to accommodate changes in the working fluid volume due to changes in the operating temperatures as the spacecraft encounters varying thermal environments during its mission. Overall, the three key requirements on the accumulator to maintain an appropriate pressure range throughout the mission are: accommodation of the volume change of the fluid due to temperature changes, avoidance of pump cavitation and prevention of boiling in the liquid. The sizing and design of such an accumulator requires very careful and accurate accounting of temperature distribution within each element of the working fluid for the entire range of conditions expected, accurate knowledge of volume of each fluid element, assessment of corresponding pressures needed to avoid boiling in the liquid, as well as the pressures needed to avoid cavitation in the pump. The appropriate liquid and accumulator strokes required to accommodate the liquid volume change, as well as the appropriate gas volumes, require proper sizing to ensure that the correct pressure range is maintained during the mission. Additionally, a very careful assessment of the process for charging both the gas side and the liquid side of the accumulator is required to properly position the bellows and pressurize the system to a level commensurate with requirements. To achieve the accurate sizing of the accumulator and the charging of the system, sophisticated EXCEL based spreadsheets were developed to rapidly come up with an accumulator design and the corresponding charging parameters. These spreadsheets have proven to be computationally fast and accurate tools for this purpose. This paper will describe the entire process of designing and charging the system, using a case study of the Mars Science Laboratory (MSL) fluid loops, which is en route to Mars for an August 2012 landing.

HRS↗

Progress Towards Modeling a Rapid Cycle Adsorption Pump for CO2 Compression

A Rapid Cycle Adsorption Pump (RCAP) is a competitive technology for capturing and pressuring CO2 within a Martian In-Situ Resource Utilization (ISRU) system. In an ISRU plant, CO2 from the Martian atmosphere at ~0.69-0.925kPa must first be pressured to ~101-500kPa to produce O2 and/or CH4. A RCAP pressurizes CO2 by imposing fast temperature swings on an adsorbent bed low pressure CO2 is adsorbed onto the cooled bed, and higher pressure CO2 is desorbed from the heated bed. To aid the design of a RCAP for NASA's Advanced Exploration Systems (AES) ISRU project, a finite difference thermal model of a single stack RCAP was developed in Thermal Desktop. The stack consists of one gas passage sandwiched between two sorbent beds and two cold plates (for heating/cooling each bed). The model implements adsorption/desorption physics via a linear driving force approximation in order to predict both temperature and pressure swings in the pump. The modeling approach is presented along with a discussion of its results and the current design. The model was also used to trade cooling speed when constructing the RCAP with 3D printed high thermal conductivity copper (GRCop-84) verses 3D printed aluminum (AlSi10mg). A wide assembly was modeled to predict the performance of multiple stacks in parallel. Major performance drivers were identified to be 1) the contact heat transfer to the sorbent bed, and 2) the pump's thermal mass.

Modeling↗

Integrated Pump Assembly - An Active Cooling System for Mars Pathfinder Thermal Control

The Mars Pathfinder spacecraft which will be launched in December 1996 features an active cooling system for controlling the temperature of the spacecraft. This will be the first time that such a mechanical pump cooling system is used on an interplanetary or long duration flight (over two weeks) in space. The major element of the cooling system is the Integrated Pump Assembly (IPA). It uses centrifugal pumps to circulate liquid Freon to transfer heat from spacecraft electronics to an external radiator. This paper describes the design, fabrication, assembly, and testing of the IPA.

cooling↗

Mechanical Pumped Cooling Loop for Spacecraft Thermal Control

The Mars Pathfinder (MPF) spacecraft, scheduled for a December '96 launch to Mars, uses a mechanically pumped loop to transfer dissipated heat from the insulated lander electronics to an external radiator. This paper discusses the tradeoffs performed before choosing a mechanically pumped loop as the thermal control system for MPF. It describes the analysis, design, and predicted performance of this system. The various development tests performed are discussed along with the current status of this cooling system. Finally, some thoughts on the development of mechanically pumped loops for future spacecraft are presented.

Mars↗

(abstract) Mars Pathfinder Active Thermal Control System: Ground and Flight Performance of a Mechanically Pumped Cooling Loop

A key element of the Mars Pathfinder thermal control system is the Heat Rejection System (HRS). The HRS of Mars Pathfinder is designed to actively control the temperatures of the various parts of the spacecraft.This is achieved by mechanically circulating single-phase Freon 11 liquid through the lander and cruise electronics box heat exchangers and transferring the heat to an external radiator on the cruise stage. This is the first time in spacecraft history that a mechanically pumped cooling loop has been used on a long duration spacecraft mission. Many lessons have been learned during the testing and ground and flight operation of the HRS. This paper will present the performance of the mechanically pumped cooling loop during the ground and flight operations. Based on the lessons learned from this experience, recommendations on the design and operation of the pumped cooling loops for future space missions will be made.

Mars↗

Experimental Results of a Rapidly Cycled Temperature Swing Adsorption Pump in a Terrestrial Environment

To improve the increasing CO 2 levels on Earth, technology for carbon capture and utilization must be efficient and cost effective. One major contributor of atmospheric CO 2 is post-combustion flue gas, which can contain up to 20% CO 2 . Scrubbing this CO 2 could reduce the environmental impact of this common industrial process. In off-Earth environments, capturing and utilizing CO 2 from space resources is useful for crewed spaceflight life support. Specifically, the Bosch process, which produces water and carbon powder by reacting CO 2 and hydrogen, is a possible in-situ resource utilization (ISRU) architecture for the Moon and Mars. The Rapid Cycle Temperature Swing Adsorption (RC-TSA) pump is an innovative technology designed to capture CO 2 efficiently. The RC-TSA leverages a stacked plate geometry to cycle multiple zeolite-coated beds. The thin layers allow for rapid heat transfer of the zeolite coating, which improves performance over previously tested pump designs. The design is favorable for scalability and manufacturability, which are forward work. Initial testing of the sorption pump using a simulated flue gas environment shows favorable breakthrough capacities and reduced cycle times. Results show promise for on- and off-Earth applications, such as a Martian surface and crewed spaceflight environments.

adsorption pump↗