A Comparison of Lumpectomy Cavity Delineations Between Use of Magnetic Resonance Imaging and Computed Tomography Acquired With Patient in Prone Position for Radiation Therapy Planning of Breast Cancer

Purpose: To compare lumpectomy cavity (LC) and planning target volume (PTV) delineated with the use of magnetic resonance imaging (MRI) and computed tomography (CT) and to examine the possibility of replacing CT with MRI for radiation therapy (RT) planning for breast cancer. Methods and Materials: MRI and CT data were acquired for 15 patients with early-stage breast cancer undergoing lumpectomy during RT simulation in prone positions, the same as their RT treatment positions. The LCs were delineated manually on both CT (LC-CT) and MRI acquired with 4 sequences: T1, T2, STIR, and DCE. Various PTVs were created by expanding a 15-mm margin from the corresponding LCs and from the union of the LCs for the 4 MRI sequences (PTV-MRI). Differences were measured in terms of cavity visualization score (CVS) and dice coefficient (DC). Results: The mean CVSs for T1, T2, STIR, DCE, and CT defined LCs were 3.47, 3.47, 3.87, 3.50. and 2.60, respectively, implying that the LC is mostly visible with a STIR sequence. The mean reductions of LCs from those for CT were 22%, 43%, 36%, and 17% for T1, T2, STIR, and DCE, respectively. In 14 of 15 cases, MRI (union of T1, T2, STIR, and DCE) defined LC included extra regions that would not be visible from CT. The DCs between CT and MRI (union of T1, T2, STIR, and DCE) defined volumes were 0.65 ± 0.20 for LCs and 0.85 ± 0.06 for PTVs. There was no obvious difference between the volumes of PTV-MRI and PTV-CT, and the average PTV-STIR/PTV-CT volume ratio was 0.83 ± 0.23. Conclusions: The use of MRI improves the visibility of LC in comparison with CT. The volumes of LC and PTV generated based on a MRI sequence are substantially smaller than those based on CT, and the PTV-MRI volumes, defined by the union of T1, T2, STIR, and DCE, were comparable with those of PTV-CT for most of the cases studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Timing of Radiation Therapy and Chemotherapy After Breast-Conserving Surgery for Node-Positive Breast Cancer: Long-Term Results From International Breast Cancer Study Group Trials VI and VII

Purpose: To update the previous report from 2 randomized clinical trials, now with a median follow-up of 16 years, to analyze the effect of radiation therapy timing on local failure and disease-free survival. Patients and Methods: From July 1986 to April 1993, International Breast Cancer Study Group trial VI randomly assigned 1475 pre-/perimenopausal women with node-positive breast cancer to receive 3 or 6 cycles of initial chemotherapy (CT). International Breast Cancer Study Group trial VII randomly assigned 1212 postmenopausal women with node-positive breast cancer to receive tamoxifen for 5 years, or tamoxifen for 5 years with 3 early cycles of initial CT. For patients who received breast-conserving surgery (BCS), radiation therapy (RT) was delayed until initial CT was completed; 4 or 7 months after BCS for trial VI and 2 or 4 months for trial VII. We compared RT timing groups among 433 patients on trial VI and 285 patients on trial VII who received BCS plus RT. Endpoints were local failure, regional/distant failure, and disease-free survival (DFS). Results: Among pre-/perimenopausal patients there were no significant differences in disease-related outcomes. The 15-year DFS was 48.2% in the group allocated 3 months initial CT and 44.9% in the group allocated 6 months initial CT (hazard ratio [HR] 1.12; 95% confidence interval [CI] 0.87-1.45). Among postmenopausal patients, the 15-year DFS was 46.1% in the no-initial-CT group and 43.3% in the group allocated 3 months initial CT (HR 1.11; 95% CI 0.82-1.51). Corresponding HRs for local failures were 0.94 (95% CI 0.61-1.46) in trial VI and 1.51 (95% CI 0.77-2.97) in trial VII. For regional/distant failures, the respective HRs were 1.15 (95% CI 0.80-1.63) and 1.08 (95% CI 0.69-1.68). Conclusions: This study confirms that, after more than 15 years of follow-up, it is reasonable to delay radiation therapy until after the completion of standard CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions

Purpose: To determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. Methods and Materials: Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. Results: Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57 (95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52 (95% CI 0.48-0.56) for MRI supine, 0.56 (95% CI 0.53-0.59) for CT prone and 0.55 (95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41 (95% CI 0.36-0.46) for supine and 0.38 (0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. Conclusions: Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Verification of a High-Dose-Rate Iridium 192 Source Position Using a Modified C-Arm Fluoroscope

Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Geriatric Assessment Tools in Selecting Therapies in Women Aged ≥70 Years With Hormone Receptor–Positive Early-Stage Breast Cancer: Preliminary Experience With a Quality Improvement Initiative

Purpose: To develop a multidisciplinary algorithmic approach to management of women aged ≥70 years with clinically staged T1N0 hormone receptor–positive breast cancer, including geriatric assessments predicting life expectancy and the likelihood of functional decline in the near future, in the context of a program-wide quality improvement initiative, to better select patients for therapeutic interventions. Methods and Materials: Two geriatric assessment tools, the Combined Lee-Schonberg Index and the Vulnerable Elderly Scale, were introduced into our clinical workflow to predict long-term mortality and likelihood of functional decline. Scores from these tools, along with patient preferences and clinical features, were incorporated into a preoperative algorithm addressing the use of sentinel lymph node biopsy (SLNB), and a postoperative algorithm addressing the use of adjuvant radiation therapy (RT). Results: The algorithms were approved for use in August 2015. Twenty-four patients were identified by in-clinic screening and have been managed using the algorithms as a guide. Mean patient age was 80 years (range, 71-89 years). Per the preoperative algorithm, consideration of omission of SLNB was an option in 11 of 24 patients (46%), and in total 18 of 24 (75%) opted against SLNB. Per the postsurgical algorithm, consideration of omission of adjuvant RT was an option for 19 of 24 patients (79%), and in total 17 of 24 (71%) opted to forego RT. Conclusion: Incorporation of simple geriatric assessments seems to have had a marked impact on decision making regarding both surgical and adjuvant therapies for women aged ≥70 years with early-stage hormone-positive breast cancer compared with historical patterns, with ≥71% omission of both SLNB and adjuvant RT in patients managed according to an institutional quality improvement initiative.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Negative to positive magnetoresistance and magnetocaloric effect in Pr 0.6 Er 0.4 Al 2

We report on the magnetic, magnetocaloric and magnetotransport properties of Pr 0.6 Er 0.4 Al 2 . The title compound exhibits a large positive magnetoresistance (MR) for H ≥ 40 kOe and a small but non negligible negative MR for H ≤ 30 kOe. The maximum positive MR reaches 13% at H = 80 kOe. The magnetic entropy and adiabatic temperature changes as functions of temperature each show two anomalies: a broad dome-like maximum below 20 K and a relatively sharp peak at higher temperature. As a result, observed behaviors are unique among other binary and mixed lanthanide compounds.

36 MATERIALS SCIENCE↗

Optimum Positioning for Anteroposterior Pelvis Radiography: A Literature Review

Pelvic radiography is used for the identification of hip joint changes, including pathologies such as osteoarthritis. Several studies have recommended that the position for this radiological procedure should be standing, not supine, to reflect the functional appearances of the hip joint. The aim of this review was to evaluate pelvis radiography positioning with respect to the image appearances and information provided for clinical decision-making. Aside from this, potential recommendations to the radiographic technique for an erect pelvis projection will be considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A spin-wave magnetometer with a positive feedback

In this work, we demonstrate experimentally the operation of a spin-wave magnetometer integrated into a circuit with a positive feedback. The circuit consists of the passive magnetic and active electric parts. The magnetic part includes a sensing element, which is a magnetic cross junction made of Y 3 Fe 2 (FeO 4 ) 3 . The electric part includes a non-linear amplifier and a phase shifter. The electric and magnetic parts are connected via micrometer size antennae. Spin waves are excited by two of these antennae while the output inductive voltage produced by the interfering spin waves is detected by the third antenna. Spin waves propagating in the orthogonal arms of the cross can accumulate significantly different phase shifts, depending on the direction and the strength of the external magnetic field. The output inductive voltage reaches its maximum in the case of constructive spin wave interference. The positive feedback provides further signal amplification. It appears possible to enhance the response function, compared to the passive circuits without a feedback, by a factor of ×100 without an increase in the noise level. The experimental data show a prominent response to the external magnetic field variation, exceeding 5 x 10 3 V/T. The intrinsic noise spectral density of the device can be as low as 10 -16 V 2 /Hz. The estimated sensitivity of the prototype device is 2 x 10 -12 T/√Hz at room temperature. We argue that spin-wave magnetometers can potentially be as sensitive as SQUIDs while operating at room temperature.

36 MATERIALS SCIENCE↗

Evaluation of commercial lithium-ion cells based on composite positive electrode for plug-in hybrid electric vehicle applications. Part I: Initial characterizations

Evaluating commercial Li-ion batteries presents some unique benefits. One of them is to use cells made from established fabrication process and form factor, such as those offered by the 18650 cylindrical configuration, to provide a common platform to investigate and understand performance deficiency and aging mechanism of target chemistry. Such an approach shall afford us to derive relevant information without influence from processing or form factor variability that may skew our understanding on cell-level issues. A series of 1.9 Ah 18650 lithium ion cells developed by a commercial source using a composite positive electrode comprising (LiMn1/3Ni1/3Co1/3O2 + LiMn2O4) is being used as a platform for the investigation of certain key issues, particularly path-dependent aging and degradation in future plug-in hybrid electric vehicle (PHEV) applications, under the US Department of Energy's Applied Battery Research (ABR) program. Here we report in Part I the initial characterizations of the cell performance and Part II some aspects of cell degradation in 2C cycle aging. The initial characterizations, including cell-to-cell variability, are essential for life cycle performance characterization in the second part of the report when cell-aging phenomena are discussed. Due to the composite nature of the positive electrode, the features (or signature) derived from the incremental capacity (IC) of the cell appear rather complex. In this work, the method to index the observed IC peaks is discussed. Being able to index the IC signature in details is critical for analyzing and identifying degradation mechanism later in the cycle aging study.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of commercial lithium-ion cells based on composite positive electrode for plug-in hybrid electric vehicle applications. Part II. Degradation mechanism under 2 C cycle aging

Degradation phenomena and inference of their underlying mechanisms during 2 C cycle aging in a cell design comprising {l_brace}LiMn1/3Ni1/3Co1/3O2 + LiMn2O4{r_brace} composite positive electrode are studied and reported in this work. We describe how aging phenomena in the cells were studied and incremental capacity analysis applied to infer cell degradation mechanisms in the cycle aging process. Two stages of degradation were observed in the life cycle under this aging regime. In the first stage, we conclude that loss of lithium inventory was the cause of capacity fade. As a result of such parasitic loss, the cell further suffered from loss of active materials in the second stage, in which the positive electrode kinetics was hampered and the capacity loss accelerated.

33 ADVANCED PROPULSION SYSTEMS↗

Positive and negative effects of dielectric breakdown in transformer oil based magnetic fluids

The transformer oil based magnetic fluids can be considered as the next-generation insulation fluids because they offer exciting new possibilities to enhance dielectric breakdown voltage as well as heat transfer performance compared to pure transformer oils. In this study, we have investigated the dielectric breakdown strength of the fluids with the various volume concentrations of nanoparticles in accordance with IEC 156 standard and have tried to find the reason for changing the dielectric breakdown voltage of the fluids from the magnetic field analysis. It was found that the dielectric breakdown voltage of pure transformer oil is around 12 kV with the gap distance of 1.5 mm. In the case of our transformer oil-based magnetic fluids with 0.08% < Φ < 0.6% (Φ means the volume concentration of magnetic nanoparticles), the dielectric breakdown voltage shows above 40 kV, which is 3.3 times higher positively than that of pure transformer oil. Negatively in the case when the volume concentration of magnetic nanoparticles is above 0.65%, the dielectric breakdown voltage decreases reversely. From the magnetic field analysis, the reason might be considered as two situations: the positive is for the conductive nanoparticles dispersed well near the electrodes, which play an important role in converting fast electrons to slow negatively charged particles, and the negative is for the agglomeration of the particles near the electrodes, which leads to the breakdown initiation.

36 MATERIALS SCIENCE↗

Spectrally-dependent positive and negative photo-plastic effects in CdZnTe and CdZnTeSe

We studied the Vickers microhardness HV0.025 of CdZnTe and CdZnTeSe samples upon illumination with quasi-monochromatic light with wavelengths ranging between 750 and 1540 nm. We observed that light with a wavelength close to or above the bandgap of the samples results in a positive photo-plastic effect (hardening), and light in the spectral range well below the band gap can lead both to positive or negative effects depending on the parameters of deep levels in the bandgap. We performed measurements of spectrally dependent photoconductivity and compared them with HV0.025. Based on the analysis, we propose a complex qualitative model explaining the spectral dependence of HV0.025 by the charging and neutralization of deep levels by optical transitions between the valence and conduction bands and between the bands and deep levels in the band gap. Tuning of parameters of deep levels could be used to control the sign and magnitude of the photo-plastic effect.

36 MATERIALS SCIENCE↗

A position and pulse shape discriminant p -terphenyl detector module

We present the development of a neutron detector array module made with para-terphenyl, a bright, fast, n/γ discriminating crystalline organic scintillator. The module is comprised of 2 cm × 2 cm × 2 cm p-terphenyl crystals that have been optically coupled together to create a pseudo-bar module. While only relying on two photo detectors, the module is capable of distinguishing interactions between up to eight crystals. Furthermore, the module retains the p-terphenyl’s pulse shape discrimination (PSD) capability. Together this makes the pseudo-bar module a promising position-sensitive neutron detector. Here we present characteristics of the pseudo-bar module - its timing resolution as well as its pulse shape and position discrimination capabilities, and briefly discuss future plans for utilizing an array of pseudo-bar modules in a useful neutron detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Positive-ion accelerator mass spectrometry at ATLAS: Peaks and pits

Electron Cyclotron Resonance (ECR) ion sources and the production of multiple-charge positive ions with high efficiency in combination with a heavy-ion accelerator have opened the way to an alternative and complementary version of accelerator mass spectrometry (AMS). A notable strength of positive-ion over traditional AMS is the capability of ultra-high sensitivity detection of radioactive isotopes of noble gases, in particular 37 Ar (t 1/2 = 35 d) and 39 Ar (269 y). The complete dissociation of molecular ions in the ECR and in particular of hydride ions of neighboring stable isotopes results in superior isotopic separation. However, the use of high charge states, necessary for acceleration to high energy, entails the existence of severe transmission degeneracies with stable ions having nearly equal mass-to-charge ratios, in addition to that of stable isobaric ions. Separation or discrimination of these parasitic ions require powerful and sophisticated dispersive systems at detection stage. In conclusion, we review here work performed and in progress at the ATLAS facility of Argonne National Laboratory (ANL) where an ECR ion source, a Radio-Frequency Quadrupole (RFQ), a superconducting linear accelerator and a Gas-Filled Magnet (GFM) are used as an AMS setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expansion of CD26 positive fibroblast population promotes keloid progression

Background: Keloid is a skin fibrosis disease that characterised by invasive growth of fibroblasts and aberrant deposition of extracellular matrix. Studies indicated that keloid fibroblasts (KFs) is a class of ‘activated’ fibroblasts, which show accelerated proliferation and excessive extracellular matrix formation as compared with normal fibroblasts (NFs). However, the mechanism underlying keloid fibroblasts dysfunction is still unknown. Objective: To verify CD26 expression difference between KFs and NFs, and investigate the function of CD26 positive fibroblasts in keloid progression. Methods: KFs and NFs were isolated from Keloid tissues and normal skin tissues respectively. Flow cytometry was performed to isolate CD26+/CD26- fibroblasts from KFs and NFs. Proliferation of different fibroblasts were analyzed by CCK8 assay and Ki 67 straining. Profibrotic phenotype difference was detected by qRT-PCR, western blot, ELISA and immunofluorescence. Scratching experiment and transwell assay were used to assess invasion ability of CD26+/CD26- fibroblasts. Diprotin A was used as a CD26 inhibitor to further investigated the function of CD26 fibroblasts in keloid disease. Result: CD26 expression was increased in KFs, and the proportion of CD26+ fibroblasts was significantly increased in KFs. Cell viability analysis showed that CD26+ fibroblasts was more active in proliferation. Furthermore, the expression of profibrotic genes were increased in CD26+ fibroblasts, including TGF-β1, IGF-1, IL6, collagen 1, collagen 3 and fibronectin. And meanwhile, CD26+ fibroblasts showed stronger invasion ability as compared to CD26- fibroblasts. Moreover, Diprotin A significantly suppressed proliferation and extracellular matrix secretion of CD26+ fibroblasts isolated from keloid tissues. Conclusion: Our findings suggest that CD26+ fibroblasts possess proliferation advantage in compare to CD26- fibroblasts, and the advantage caused expansion of CD26 positive fibroblast population promotes keloid progression.

60 APPLIED LIFE SCIENCES↗

STING positively regulates human ORMDL3 expression through TBK1-IRF3-STAT6 complex mediation

Highlights: • STING and ORMDL3 genes expression was increased in patients with recurrent wheeze. • STING upregulates ORMDL3 expression and promoter activity in cells. • ORMDL3 is positively associated with the STING-TBK1-IRF3/STAT6 signaling pathway. • STING increases the ORMDL3 expression in asthma and recurrent wheeze by promoting both the expression and activity of the TBK1-IRF3-STAT6 complex. Orosomucoid 1-like protein 3 (ORMDL3) is an asthma candidate gene associated with virus-triggered recurrent wheeze. Stimulator of interferon gene (STING) controls TLR-independent cytosolic responses to viruses. However, the association of STING with ORMDL3 is unclear. Here, we have shown that ORMDL3 expression shows a linear correlation with STING in recurrent wheeze patients. In elucidating the molecular mechanisms of the ORMDL3-STING relationship, we found that STING promoted the transcriptional activity of ORMDL3, which was significantly associated with increased levels of interferon regulatory factor 3 (IRF3) and signal transducer and activator of transcription 6 (STAT6). Further study showed that via activation of TANK binding kinase 1 (TBK1), STING enhanced the phosphorylation and binding of IRF3 and STAT6, which upregulated ORMDL3 by binding to the promoter. Our results showed that STING positively regulated ORMDL3 through the TBK1-IRF3-STAT6 complex.

60 APPLIED LIFE SCIENCES↗

Quantification of the Electrostatic Effect on Redox Potential by Positive Charges in a Catalyst Microenvironment

Charged functional groups in the secondary coordination sphere (SCS) of a heterogeneous nanoparticle or homogeneous electrocatalyst are of growing interest due to enhancements in reactivity that derive from specific interactions that stabilize substrate binding or charged intermediates. At the same time, accurate benchmarking of electrocatalyst systems most often depends on the development of linear free-energy scaling relationships. Furthermore, the thermodynamic axis in those kinetic–thermodynamic correlations is most often obtained by a direct electrochemical measurement of the catalyst redox potential and might be influenced by electrostatic effects of a charged SCS. In this report, we systematically probe positive charges in a SCS and their electrostatic contributions to the electrocatalyst redox potential. A series of 11 iron carbonyl clusters modified with charged and uncharged ligands was probed, and a linear correlation between the ν CO absorption band energy and electrochemical redox potentials is observed except where the SCS is positively charged.