At least 1,027 records · Page 57

Simulated Lunar Gravity Testing of VIPER Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) mission consists of a rover designed to explore the lunar south pole. One of the main challenges faced by the rover during the lunar polar exploration is the adverse thermal environment. Temperatures can fluctuate more than a 100°C between day and night; potentially dropping to −246°C in permanent shadow regions. To maintain the rover components within temperature limits, VIPER’s Thermal Management System (TMS) relies heavily on Loop Heat Pipes (LHPs). To assist the design of the thermal management system, an Engineering Design Unit (EDU) LHP has been tested in several opportunities under thermal vacuum (TVAC) environment. Of particular interest was the LHP performance in lunar gravity. To that end, the EDU LHP was tested at the nominal orientation within the rover assembly, vertical, and inclined such that the gravitational component acting on the LHP evaporator and condenser was 1/6g (lunar gravity is 1/6 of Earth gravity) when compared to the vertical configuration. This paper will examine the LHP conductance as one the key parameters to assess the effect of the gravity on the LHP performance.

Loop Heat Pipe↗

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe↗

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe↗

SIMULATED BUILDING ENERGY PERFORMANCE OF SINGLE-FAMILY DETACHED RESIDENCES DESIGNED FOR OFF-GRID, OFF-PIPE OPERATION

This paper presents the analysis of energy performance of single-family detached homes in three U.S. climates, in order to determine energy-efficiency measures for minimizing the loads and sizing requirements of renewable energy systems that are essential for its offgrid, off-pipe (i.e., utility-independent) operation. The analysis used a DOE-2.1e simulation model of a 2000/2001 IECC (International Energy Conservation Code) standard house as a base case in three climate locations: Minneapolis, MN, Atlanta, GA, and Phoenix, AZ. This selection of measures and determination of loads for renewable energy systems were accomplished by analyzing the energy use using DOE-2.1e simulations and heating/cooling load components using the Manual J Average Load Procedure. The analysis showed several aspects of building energy performance during different times of the year in terms of available energy resources that are critical for the sizing, utilization, and cost effectiveness of renewable energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rigid-plug elastic-water model for transient pipe flow with entrapped air pocket

Pressure transients in a rapidly filling pipe with an entrapped air pocket are investigated analytically. A rigid-plug elastic water model is developed by applying elastic water hammer to the majority of the water column while applying rigid water analysis to a small portion near the air-water interface, which avoids effectively the interpolation error of previous approaches. Moreover, another two simplified models are introduced respectively based on constant water length and by neglecting water elasticity. Verification of the three models is confirmed by experimental results. Calculations show that the simplification of constant water length is feasible for small air pockets. The complete rigid water model is appropriate for cases with large initial air volume. The rigid-plug elastic model can predict all the essential features for the entire range of initial air fraction considered in this study, and it is the effective model for analysis of pressure transients of entrapped air.

42 ENGINEERING↗

Silicon Carbide Multilayer Piping for High Temperature sCO 2 Brayton Cycle

Efficiencies of greater than 50% in supercritical carbon dioxide (sCO 2 ) Brayton power cycle systems can be achieved only at turbine inlet temperatures of above 700°C. In support of the push to higher temperatures, a finite element model was developed by Materials Research & Design, Inc. (MR&D) with support from Ceramic Tubular Products, LLC. (CTP) to guide the refinement of CTP’s high temperature ceramic multilayer piping. The multilayer technology combines the advantages of a monolithic silicon carbide (SiC) tube and a SiOC f /SiOC ceramic matrix composite (CMC), the result of which is a material with high-temperature strength and stability, high mechanical and thermal shock resistance, and high corrosion resistance. In addition to fabricating test specimens to refine the finite element model, long-duration, high temperature CO 2 exposure tests were performed by Sandia National Laboratories (SNL) on two varieties of inner monolithic SiC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Decontamination Process of Internal Part Pipes - 13442

The Marcoule Site, created in 1955 is one of the first nuclear sites in France. It combines the activities of the Research Centre of the French Atomic Energy Commission (CEA) and AREVA industrial operations. Today, a large part of the operations on this site consists of the cleaning and the dismantling of nuclear Installations, once the end of their life cycle has been reached. An example can be the reprocessing plant UP1. This unit, started in 1958 has been stopped in 1997 and its dismantling started quickly thereafter. Technical challenges of the UP1 dismantling are mainly linked to a very high risk of exposure due to a large variety of contaminated equipments and residuals of fission products, potential sources of irradiation. The dismantling of Hall 71 is a typical example of such challenge. This paper will present a solution developed by AREVA Clean-Up business unit, in collaboration with COFIM Industry, to remove contamination incrusted inside the pipes before starting the cutting operations, thus reducing irradiation risk. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operation and Security Considerations for Heat Pipe Cooled Microreactors

Microreactors and small modular reactors (SMRs) are anticipated to be key elements in the United States' carbon-free energy portfolio, serving as reliable power sources for remote communities, disaster relief zones, extraterrestrial deployments, and backup power needs. Microreactors employ technologies that are substantially more advanced and recent compared to conventional reactors. Furthermore, they are of a drastically smaller scale and are designed to be operated in a diverse set of locations, offering operational flexibility and mobility. In addition, the autonomous or semi-autonomous operation of microreactors with minimal or no on-site staff is anticipated. These factors give rise to specific challenges with regards to their safety and security. The present work investigates considerations related to heat pipe operation, reactor transport, and cyber/cyberphysical security to ensure the indirect and direct consequences of nefarious actors’ actions are understood and can be mitigated by design or through physical security measures. In addition, future directions are proposed for consideration by both HPMR designers and for regulators.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Pipe Modeling with Sockeye

This presentation gives an overview of the models in the heat pipe code Sockeye, as well as the current status of its validation.

42 ENGINEERING↗

Heat Pipe Modeling Capabilities in Sockeye

Presentation to be given in a meeting with stakeholders of the Nuclear Energy Advanced Modeling and Simulation program for modeling related to microreactors. This presentation gives an overview of the capabilities and status of the heat pipe code Sockeye.

97 MATHEMATICS AND COMPUTING↗

Surrogates for Valve-Controlled Pipe Flow: Accelerating Nuclear Reactor Design

Neural surrogate models are developed to replace expensive steady-state RANS CFD simulations for valve-controlled pipe flow in nuclear reactor design. Using parametric CFD data generated with MOOSE Pronghorn across a range of valve geometry and flow conditions, three approaches are compared: a POD-based reduced-order model, a structured UNet on a cylindrical grid, and unstructured models (DeepONet and BiStride MeshGraphNet) on nondimensionalized point clouds. POD achieves the highest accuracy (99%) with fast inference but requires storing all solution snapshots, while the DeepONet and BSMS-GNN both achieve ~89% accuracy at sub-second inference, with the BSMS-GNN offering superior geometric generalizability. These surrogates enable rapid ranking of candidate valve designs and can warm-start CFD solvers to accelerate convergence, supporting agentic design iteration on the Prometheus platform.

42 - ENGINEERING↗

Method for evaluating the technical state of boilers and piping in thermal power plants

An approach for evaluating the current technical state of thermal equipment in thermal power plants is discussed. A system of parameters and corresponding criteria are developed for the technical state of groups of essential components of boilers and piping. Ascale for evaluation of safety factors is proposed in terms of the relationship between state parameters and the corresponding criteria. Analytic expressions are given for an approximate evaluation of the maximum lifetime limit for operation of an object in terms of an integral safety factor and an evaluation of this type is illustrated for the case of the live steam pipeline in a 300-MW unit. An algorithm is set up for actions to be taken by equipment owners in organizing monitoring of the technical state of the equipment.

20 FOSSIL-FUELED POWER PLANTS↗

Effect of Tempered Martensite and Ferrite/Bainite on Corrosion Behavior of Low Alloy Steel Used for Flexible Pipe Exposed to High-Temperature Brine Environment

Immersion experiments and electrochemical measurements were carried out to study the effect of tempered martensite and ferrite/bainite on corrosion behavior of low alloy steel used for flexible pipe exposed to high-temperature brine environment in terms of microstructure morphology, corrosion rate, corrosion products characteristics, potentiodynamic polarization curves and electrochemical impedance spectroscopy. The experimental results indicated that the proportion of high-angle grain boundaries of tempered martensite steel was greater than ferrite/bainite steel. The corrosion rate of ferrite/bainite steel was lower than tempered martensite steel. With increasing immersion time, the structure of corrosion products formed on the surface of ferrite/bainite steel was more compact and denser than tempered martensite steel. In addition, the current density of ferrite/bainite steel was lower than tempered martensite steel. The charge transfer resistance and total impedance of ferrite/bainite steel were larger than tempered martensite steel. Thus, the corrosion resistance of ferrite/bainite steel exposed to high-temperature brine environment was excellent compared to the tempered martensite steel.

36 MATERIALS SCIENCE↗

Corrosion Resistances of Steel Pipe Coated with Two Types of Enamel by Two Coating Processes

The corrosion behaviors of uncoated, enamel-coated, and epoxy-coated steel samples were evaluated in 3.5 wt.% NaCl solution with open-circuit potential, electrochemical impedance spectroscopy and potentiodynamic polarization tests. Two types of enamel (powder and slurry) were coated on steel samples in electrostatic and wet spraying processes, respectively. Twelve 25 mm × 25 mm steel samples were cut from an API 5L X65 pipe of 323.850 mm in outer diameter and 9.525 mm in wall thickness. They were divided into four groups of three identical samples. Each group represents one of the four conditions: uncoated, powder enamel-coated, slurry enamel-coated and epoxy-coated. Scanning electron microscopy images revealed that the powder and slurry enamel coatings were approximately 180 and 235 µm thick, respectively. The powder enamel coating has fewer but larger isolated pores than the slurry enamel coating. Electrochemical tests consistently indicated that the powder and slurry enamel coatings provided slightly better and worse corrosion protection to the coated steel samples, respectively, than the epoxy coating. The charge transfer resistances of all the coated samples are approximately 10{sup 8} times larger than that of the uncoated samples. All the coated samples were unlikely corroded within 2 h of immersion.