Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Two-path plasmonic interferometer with integrated detector

An electrically tunable terahertz two-path plasmonic interferometer with an integrated detection element can down convert a terahertz field to a rectified DC signal. The integrated detector utilizes a resonant plasmonic homodyne mixing mechanism that measures the component of the plasma waves in-phase with an excitation field that functions as the local oscillator in the mixer. The plasmonic interferometer comprises two independently tuned electrical paths. The plasmonic interferometer enables a spectrometer-on-a-chip where the tuning of electrical path length plays an analogous role to that of physical path length in macroscopic Fourier transform interferometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of neutrino oscillations using neutrino and antineutrino beams in the NOvA experiment

NOvA is a long-baseline accelerator neutrino oscillation experiment using the NuMIneutrino beam from Fermilab. Its main physics goals are to probe the 3-flavour oscillationparameters: neutrino mass hierarchy, CP-violating phase dcp and octant of .23 mixingangle by observing electron neutrino appearance and muon neutrino disappearance. Twofunctionally identical detectors are placed off-axis from the centre of the NuMI beam.The near detector at Fermilab is 100 m underground, and the far detector is locatedon the surface at Ash River, 810 km away from the beam source. The initial neutrinobeam spectra are measured using the near detector data and the oscillation parametersare extracted by fitting the observed data to the predicted neutrino spectrum in the fardetector.This thesis is centered around how to improve the sensitivity of |.m232| and .23 measurementsin the muon neutrino disappearance analysis. NOvA will take data for about12 years. The operation of the NOvA experiment for each year costs tens of millions ofdollars, thus it is valuable to maximise the sensitivity of the analysis. Three samples ofmuon neutrino events are studied in this thesis to improve the analysis sensitivities. First,higher energy muon neutrinos are investigated by extending the energy range in NOvA’scurrent standard analysis. Second, for the sample of events used in NOvA’s existing analysis,a new energy estimator which has been developed to improve the neutrino energy resolution is considered. Furthermore, in addition to binning the events as function ofenergy and hadronic energy fraction, three particle identifiers are introduced to separateneutrino events by signal purity to reduce the effects from backgrounds. Third, an additionallower purity sample of muon neutrino charged current (CC) events that look similarto neutral current events and have not been included in NOvA’s existing analyses havebeen studied.This thesis reanalyses NOvA’s data used in the 2020 analysis, corresponding to anexposure of 13.60×1020 protons on target (POT) in the neutrino beam mode recordedfrom February 6, 2014 to March 20, 2020, and 12.50×1020 protons on target in theantineutrino beam mode recorded between June 29, 2016 to February 26, 2019. Thisthesis has implemented a fit to Asimov fake data, generated where sin2 .23 = 0.59 and.m232 = 2.5 × 10-3 eV2. These sensitivity studies show that the uncertainty range of|.m232| at 1 s in the new analysis is reduced by 5.5% and the significance of maximaldisappearance rejection improves by 7.7%, compared to the standard analysis. This isequivalent to adding 11-16% more data. The best fit values of the oscillation parametersfrom fitting to the far detector (FD) data with the new analysis are found to besin2 .23 = 0.568+0.025-0.043 (sin2 .23 = 0.454+0.046-0.026) and .m232 = 2.399+0.055-0.070 × 10-3 eV2 (.m232= -2.427+0.055-0.067 × 10-3 eV2) for the normal (inverted) hierarchy. The difference in thebest fit for sin2 .23 (.m232) between the new analysis and NOvA’s 2020 analysis is around2% (1.4%). The uncertainty range at 1 s for .m232 decrease by 8% (4%) for the normalhierarchy (inverted hierarchy) compared to the standard analysis. The uncertainty rangefor sin2 .23 is close to the standard analysis. This thesis also implements the fit from combiningelectron neutrino appearance and muon neutrino disappearance. The combinedanalysis shows that the best fit values are very close to the standard analysis. However,the uncertainty range of .m232 at 1 s is reduced by 3.7% using the new analysis. The maximaldisappearance significance is not improved in the new analysis, but the new analysisslightly improves the rejection of the disfavoured octant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Isoscalar Resonances in yp ¿ wnp AT GLUEX

The GlueX experiment has produced the world?s largest statistics for peripheral photoproduction of mesons with a goal to search for exotic mesons. This document presents results on the search for possible intermediate resonances which decay to ??. Little is known for the states seen in this decay channel such as the ?(1420) and ?(1650). This channel also allows to search for the never seen exotics JPC = 0??, 2+?, and the elusive 2??. The ?, in this reaction, is identified via the ?+???0 decay mode and the ? and ?0 are identified via the decay to 2?. Data from the GlueX Phase I was analyzed. This data was obtained at the Thomas Jefferson National Accelerator Facility utilizing the GlueX detector and a tagged linearly polarized photon beam incident on a liquid hydrogen target. A model using the expected major wave contributors, 1+? and 1??, shows two structure in the region where the ?(1420) and ?(1650) are expected. A third structure is seen at threshold with the quantum numbers of an h1 resonance, however, more studies are needed to assert the nature of this structure. Instabilities on the m = ±1 were shown to come from mathematical ambiguities. This only occurs between the m = 1 and m = ?1 projections when both reflectivities are present in close amount. Expanding the intensity equation for a single wave allows to extract coefficients that can help describe the data. A tangent study is also presented in this document which consists on a direct fit to the lineshape of an isolated N(1535). This baryonic resonance is well established, but its Breit-Wigner parameters have only been obtained from partial wave analysis. In contrast, this study obtained the Breit-Wigner parameters using a direct fit and finds the value of the width to be 70.5± 9.2 MeV; this is half of the accepted value.

Barriga, Edmundo↗

High-speed, multi-channel detector readout electronics for fast radiation detectors

In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps, MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications.The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the SHARC DSP has been booted with preliminary code. All new ICs and circuitry on the prototype are working properly, however some of the planned firmware and software functions have not yet been completely implemented and debugged. Overall, due to the unanticipated complexity of the PCI Express interface, some aspects of the project could not be completed with the time and funds available in Phase II. These aspects will be completed in self-funded Phase III.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS were found to be different due to the difference in the tomosynthesis image reconstruction algorithms. Conclusions: It is feasible to simultaneously generate x-ray differential phase contrast, phase contrast, and absorption contrast tomosynthesis images using a grating-based data acquisition setup. The method shows promise in improving the visibility of several low-density materials and therefore merits further investigation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal Structure Evolution of U-Si Nuclear Fuel Phases as a Function of Temperature

The crystal structure of the U 3 Si 2 line compound in the U-Si system was investigated as a function of temperature from room temperature t o1373 K using high temperature neutron time-of-flight diffraction on the HIPPO diffractometer at LANSCE. The U-Si system is actively researched due to its promise as an accident tolerant nuclear fuel. The simultaneous Rietveld refinement of five histograms from the five HIPPO detector rings provided fundamental datasets for the lattice parameters, anisotropic atomic displacement parameters, and atomic positions as a function of temperature. To explore the possibility of minority phases as a result of the synthesis route and especially due to hyper-stoichiometry, a stoichiometric U 3 Si 2.00 sample and a hyper-stoichiometric U 3 Si 2.01 sample were studied. While minor differences in the anisotropic atomic displacement parameters between the two samples were observed, over the entire investigated temperature range no additional phases were observed. However, significant differences in the thermal expansion behavior were identified between the two compositions that warrant future investigations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cherenkov Counters

When a charged particle passes through an optically transparent medium with a velocity greater than the phase velocity of light in that medium, it emits prompt photons, called Cherenkov radiation, at a characteristic polar angle that depends on the particle velocity. Cherenkov counters are particle detectors that make use of this radiation. Uses include prompt particle counting, the detection of fast particles, the measurement of particle masses, and the tracking or localization of events in very large, natural radiators such as the atmosphere, or natural ice fields, like those at the South Pole in Antarctica. Cherenkov counters are used in a number of different fields, including high energy and nuclear physics detectors at particle accelerators, in nuclear reactors, cosmic ray detectors, particle astrophysics detectors and neutrino astronomy, and in biomedicine for labeling certain biological molecules.

43 PARTICLE ACCELERATORS↗

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{cos θ}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-84: Measurement and Monte-Carlo Simulation of Electron Phase Spaces Using a Wide Angle Magnetic Electron Spectrometer

Purpose: To measure and simulate well-defined electron spectra using a linear accelerator and a permanent-magnetic wide-angle spectrometer to test the performance of a novel reconstruction algorithm for retrieval of unknown electron-sources, in view of application to diagnostics of laser-driven particle acceleration. Methods: Six electron energies (6, 9, 12, 15, 18 and 21 MeV, 40cm × 40cm field-size) delivered by a Siemens Oncor linear accelerator were recorded using a permanent-magnetic wide-angle electron spectrometer (150mT) with a one dimensional slit (0.2mm × 5cm). Two dimensional maps representing beam-energy and entrance-position along the slit were measured using different scintillating screens, read by an online CMOS detector of high resolution (0.048mm × 0.048mm pixels) and large field of view (5cm × 10cm). Measured energy-slit position maps were compared to forward FLUKA simulations of electron transport through the spectrometer, starting from IAEA phase-spaces of the accelerator. The latter ones were validated against measured depth-dose and lateral profiles in water. Agreement of forward simulation and measurement was quantified in terms of position and shape of the signal distribution on the detector. Results: Measured depth-dose distributions and lateral profiles in the water phantom showed good agreement with forward simulations of IAEA phase-spaces, thus supporting usage of this simulation source in the study. Measured energy-slit position maps and those obtained by forward Monte-Carlo simulations showed satisfactory agreement in shape and position. Conclusion: Well-defined electron beams of known energy and shape will provide an ideal scenario to study the performance of a novel reconstruction algorithm using measured and simulated signal. Future work will increase the stability and convergence of the reconstruction-algorithm for unknown electron sources, towards final application to the electrons which drive the interaction of TW-class laser pulses with nanometer thin target foils to accelerate protons and ions to multi-MeV kinetic energy. Cluster of Excellence of the German Research Foundation (DFG) “Munich-Centre for Advanced Photonics”.

07 ISOTOPE AND RADIATION SOURCES↗

Improved Measurement of B^ \to\rho^ \rho^0 and Determination of the Quark-Mixing Phase Angle~\alpha

The authors present improved measurements of the branching fraction {Beta}, the longitudinal polarization fraction f{sub L}, and the direct CP asymmetry A{sub CP} in the B meson decay channel B{sup +} {yields} {rho}{sup +}{rho}{sup 0}. The data sample was collected with the BABAR detector at SLAC. The results are {Beta}(B{sup +} {yields} {rho}{sup +}{rho}{sup 0}) = (23.7 {+-} 1.4 {+-} 1.4) x 10{sup -6}, f{sub L} = 0.950 {+-} 0.015 {+-} 0.006, and A{sub CP} = -0.054 {+-} 0.055 {+-} 0.010, where the uncertainties are statistical and systematic, respectively. Based on these results, they perform an isospin analysis and determine the CKM weak phase angle {alpha} to be (92.4{sub -6.5}{sup +6.0}){sup 0}.

43 PARTICLE ACCELERATORS↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Sub-Ångstrom electric field measurements on a universal detector in a scanning transmission electron microscope

Scanning transmission electron microscopy (STEM) excels in accessing atomic-scale structure and chemistry. Enhancing our ability to directly image the functionalities of local features in materials has become one of the most important topics in the future development of STEM. Recently, differential phase contrast (DPC) imaging has been utilized to map the internal electric and magnetic fields in materials from nanoscale features such as p–n junctions, skyrmions, and even from individual atoms. Here, we use an ultra-low noise SCMOS detector in as the diffraction plane camera to collect four-dimensional (4D) datasets. The high angular resolution, efficient high-SNR acquisition, and modifiability of the camera allow it to function as a universal detector, where STEM imaging configurations, such as DPC, bright field, annular bright field, and annular dark field can all be reconstructed from a single 4D dataset. By examining a distorted perovskite, DyScO3, which possesses projected lattice spacings as small as 0.83 Å, we demonstrate DPC spatial resolution almost reaching the information limit of a 100 keV electron beam. In addition, the perovskite has ordered O-coordinations with alternating octahedral tilts, which can be quantitatively measured with single degree accuracy by taking advantage of DPC’s sensitivity to light atoms. The results, acquired on a standard Ronchigram camera as opposed to a specialized DPC detector, open up new opportunities to understand and design functional materials and devices that involve lattice and charge coupling at nano- and atomic-scales.

47 OTHER INSTRUMENTATION↗

ON DISCOVERING ELECTROMAGNETIC EMISSION FROM NEUTRON STAR MERGERS: THE EARLY YEARS OF TWO GRAVITATIONAL WAVE DETECTORS

We present the first simulation addressing the prospects of finding an electromagnetic (EM) counterpart to gravitational wave (GW) detections during the early years of only two advanced detectors. The perils of such a search may have appeared insurmountable when considering the coarse ring-shaped GW localizations spanning thousands of square degrees using time-of-arrival information alone. Leveraging the amplitude and phase information of the predicted GW signal narrows the localization to arcs with a median area of only a few hundred square degrees, thereby making an EM search tractable. Based on the locations and orientations of the two LIGO detectors, we find that the GW sensitivity is limited to only two of the four sky quadrants. Thus, the rates of GW events with two interferometers is only ≈40% of the rate with three interferometers of similar sensitivity. Another important implication of the sky quadrant bias is that EM observatories in North America and Southern Africa would be able to systematically respond to GW triggers several hours sooner than Russia and Chile. Given the larger sky areas and the relative proximity of detected mergers, 1 m class telescopes with very wide-field cameras are well-positioned for the challenge of finding an EM counterpart. Identification of the EM counterpart amidst the larger numbers of false positives further underscores the importance of building a comprehensive catalog of foreground stellar sources, background active galactic nucleus and potential host galaxies in the local universe. This initial study is based on a small sample of 17 detected mergers; future works will expand this sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Light Meson Spectroscopy with GlueX and Beyond

The GlueX experiment at Jefferson Lab was specifically designed for precision studies of the light-meson spectrum. For this purpose, a photon beam with energies up to 12 GeV is directed onto a liquid hydrogen target contained within a hermetic detector with near-complete neutral and charged particle coverage. Linear polarization of the photon beam with a maximum around 9 GeV provides additional information about the production process. In 2018, the experiment completed its first phase, recording data with a total integrated luminosity above 400 pb?1. We highlight a selection of results from this world-leading data set with emphasis on the search for light hybrid mesons. In the mean time, the detector underwent significant upgrades and is currently recording data with an even higher luminosity. The future plans of the GlueX experiment to explore the meson spectrum with unprecedented precision are summarized.

Austregesilo, Alexander↗

Performance of the reconstruction of large impact parameter tracks in the inner detector of ATLAS

Searches for long-lived particles (LLPs) are among the most promising avenues for discovering physics beyond the Standard Model at the Large Hadron Collider (LHC). However, displaced signatures are notoriously difficult to identify due to their ability to evade standard object reconstruction strategies. In particular, the ATLAS track reconstruction applies strict pointing requirements which limit sensitivity to charged particles originating far from the primary interaction point. To recover efficiency for LLPs decaying within the tracking detector volume, the ATLAS Collaboration employs a dedicated large-radius tracking (LRT) pass with loosened pointing requirements. During Run 2 of the LHC, the LRT implementation produced many incorrectly reconstructed tracks and was therefore only deployed in small subsets of events. In preparation for LHC Run 3, ATLAS has significantly improved both standard and large-radius track reconstruction performance, allowing for LRT to run in all events. This development greatly expands the potential phase-space of LLP searches and streamlines LLP analysis workflows. This paper will highlight the above achievement and report on the readiness of the ATLAS detector for track-based LLP searches in Run 3.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of 83m Kr prompt scintillation signals in the PIXeY detector

Prompt scintillation signals from 83m Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because 83m Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a signal sizes in the Particle Identification in Xenon at Yale (PIXeY) experiment and its dependence on the time separation between the two signals (Δ t), notably its increase at low Δ t. Finally, in PIXeY data, the Δ t dependence of S1b/S1a is observed to exhibit two exponential components: one with a time constant of 0.05 ± 0.02 μ s, which can be attributed to processing effects and pulse overlap and one with a time constant of 10.2 ± 2.2 μs that increases in amplitude with electric drift field, the origin of which is not yet understood.

47 OTHER INSTRUMENTATION↗