Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pseudospin-doublet bands and Gallagher Moszkowski doublet bands in 100 Y

New transitions in neutron-rich 100 Y have been identified in a 9 Be + 238 U experiment with mass and Z gates to provide full fragment identification. These transitions and high spin levels of 100 Y have been investigated by analyzing the high statistics γ–γ–γ and γ–γ–γ–γ coincidence data from the spontaneous fission of 252 Cf at the Gammasphere detector array. Two new bands, 14 new levels, and 23 new transitions have been identified. The K π = 4 + new band decaying to a 1s isomeric state is assigned to be the high-K Gallagher-Moszkowski (GM) partner of the known K π = 1 + band, with the π5/2[522]Ⓧν3/2[411] configuration. This 4 + band is also proposed to be the pseudospin partner of the new K π = 5 + band with a 5 + π5/2[422] Ⓧ ν5/2[413] configuration, to form a π5/2[422] Ⓧ ν[3125/2,3/2] neutron pseudospin doublet. Here, constrained triaxial covariant density-functional theory and quantal particle rotor model calculations have been applied to interpret the band structure and available electromagnetic transition probabilities and are found to be in good agreement with experimental values.

100Y↗

Templates of expected measurement uncertainties for prompt fission neutron spectra

In this paper, we provide templates of uncertainty sources expected to appear for three measurement types of prompt fission neutron spectra (PFNS): (1) shape measurements, (2) clean-ratio shape, that is the monitor PFNS are measured in nearly exactly the same surrounding as the PFNS of interest, and (3) indirect ratios, where the detector efficiency is backed out from PFNS monitor measurements. Information is also listed that is needed to faithfully include PFNS in nuclear data evaluations to guide experimenters on how to best report data and metadata for their measurements. These templates also suggest a typical range of pertinent uncertainty values and their correlations in case realistic uncertainties cannot be estimated from information on the measurement itself. The templates were based on a literature review, information found in EXFOR for 252 Cf, 235, 238 U, and 239 Pu PFNS, and enhanced by expertise from experimenters contributing to these PFNS templates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gravitational wave physics and astronomy in the nascent era

The detections of gravitational waves (GW) by the LIGO/Virgo collaborations provide various possibilities for both physics and astronomy. We are quite sure that GW observations will develop a lot, both in precision and in number, thanks to the continuous work on the improvement of detectors, including the expected new detector, KAGRA, and the planned detector, LIGO-India. On this occasion, we review the fundamental outcomes and prospects of gravitational wave physics and astronomy. We survey the development, focusing on representative sources of gravitational waves: binary black holes, binary neutron stars, and supernovae. We also summarize the role of gravitational wave observations as a probe of new physics.

79 ASTRONOMY AND ASTROPHYSICS↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IceCube Search for Neutrinos Coincident with Gravitational Wave Events from LIGO/Virgo Run O3

Using data from the IceCube Neutrino Observatory, we searched for high-energy neutrino emission from the gravitational-wave events detected by the advanced LIGO and Virgo detectors during their third observing run. We did a low-latency follow-up on the public candidate events released during the detectors' third observing run and an archival search on the 80 confident events reported in the GWTC-2.1 and GWTC-3 catalogs. An extended search was also conducted for neutrino emission on longer timescales from neutron star containing mergers. Follow-up searches on the candidate optical counterpart of GW190521 were also conducted. We used two methods; an unbinned maximum likelihood analysis and a Bayesian analysis using astrophysical priors, both of which were previously used to search for high-energy neutrino emission from gravitational-wave events. No significant neutrino emission was observed by any analysis, and upper limits were placed on the time-integrated neutrino flux as well as the total isotropic equivalent energy emitted in high-energy neutrinos.

79 ASTRONOMY AND ASTROPHYSICS↗

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C 3 F 8 dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. Here, the PICO collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C 3 F 8 from calibration data taken with five distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov chain Monte Carlo routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be ≥ 50% for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be ≥ 50% for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated datasets are used to calculate a p value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comprehensive study of radon progeny attachment to surfaces

Low energy, low rate experiments, such as searches for neutrinoless double β decay and dark matter, require unprecedentedly low levels of background in order to deliver their full science potential. 210 Po driven, neutron induced background, caused by nuclear (α, n) reactions on low-Z materials, direct background contributions of the 210 Po α radiation and desorption of the 210 Pb progeny 210 Bi from surfaces into the detector medium are of particular of concern. These backgrounds depend on details of the components’ exposure to radon-loaded laboratory air and, thus, their handling history. The attachment rates of airborne radon progeny to surfaces, needed for the estimation of these background rates, are poorly understood. This article reports the results of a campaign comprising of more than 1200 attachment measurements, performed for nine different materials. Correlations of the attachment with environmental parameters such as air exchange rate, electrical surface potential, temperature, atmospheric pressure, and relative humidity have been studied and found to be significant only in case of the first two. Attachment modeling, using the Jacobi model, is compared to data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Potential absence of observed π2 linear-chain structures in 14O via 10C(α,α) resonances scattering

Background: The preference for light nuclear systems to coagulate into -particle clusters has been well-studied. The possibility of a linear chain configuration of -particles would allow for a new way to study this phenomenon. Purpose: A rotational band of states in C has been claimed showing a linear chain structure. The mirror system, O, has been studied here to examine how this linear chain structure is affected by replacing the valence neutrons with protons. Method: A beam of C was incident into a chamber filled with He:CO gas with the tracks recorded inside the TexAT Time Projection Chamber and the recoil -particles detected by a silicon detector array to measure the cross section. Results: The experimental cross section was compared with previous studies and fit using R-Matrix theory with the previously-observed O states being transformed to the C using mirror symmetry. The measured cross section does not replicate the claimed states, with the predicted cross section exceeding that observed at several energies and angles. Conclusion: A series of possibilities are highlighted with the most likely being that the originally-seen C states did not constitute a rotational band with a potentially incorrect spin assignment due to the limitations of the angular correlation method with non-zero spin particles. The work highlights the difficulties in measuring broad resonances corresponding to a linear chain state in a high level density.

Bishop, J.↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Generalized method for the optimization of pulse shape discrimination parameters

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and discriminated. In neutron measurements for nuclear security and non proliferation effective PSD is crucial, because a weak neutron signature needs to be detected in the presence of a strong gamma-ray background. Here, the most commonly used deterministic PSD technique is charge integration (CI). This method requires the optimization of specific parameters to obtain the best gamma-neutron separation. These parameters depend on the scintillating material and light readout device and typically require a lengthy optimization process and a calibration reference measurement with a mixed source. In this paper, we propose a new method based on the scintillation fluorescence physics that enables to find the optimum PSD integration gates using only a gamma-ray emitter. We demonstrate our method using three organic scintillation detectors: deuterated trans-stilbene, small-molecule organic glass, and EJ-309. In all the investigated cases, our method allowed finding the optimum PSD CI parameters without the need of iterative optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Capture and Transmission Measurements of 54 Fe at the RPI LINAC

54 Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54 Fe sample in the keV energy region. 54 Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54 Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C 6 D 6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54 Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54 Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54 Fe up to roughly 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

New NDA Methods for Thorium Fuel Cycle Safeguards (Mid-Project Report)

This project is developing new Non-Destructive Assay (NDA) safeguards techniques for emergent thorium fuel cycles based on Neutron Resonance Transmission Analysis (NRTA), which can assay 233 U and 235 U when they are present together in a sample with potentially high gamma-ray backgrounds from fission products and 232 U. Existing passive techniques face large challenges for this task so new active interrogation methods are needed. This effort is also exploring how gamma-ray signatures can complement NRTA for enhanced assayed performance. This project leverages an NRTA system being developed at PNNL in collaboration with MIT, which uses a commercially available deuterium-tritium neutron generator at short standoff (~2 m). We aim to assess the feasibility and performance of these new NDA techniques for the range of relevant samples in thorium fuel cycles. Key advancements described in this mid-project report include NRTA system design for thorium safeguards measurements, characterization of 233 U oxide powder at PNNL, a survey of detector technologies suitable for NRTA in high gamma background environments, successful preliminary demonstration of a quantitative isotopic estimation algorithm, and first NRTA measurements of a thorium sample.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity of future liquid argon dark matter search experiments to core-collapse supernova neutrinos

Future liquid-argon DarkSide-20k and Argo detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of ~50 t and ~360 t for DarkSide-20k and Argo respectively. Thanks to the low-energy threshold of ~0.5 keVnr achievable by exploiting the ionization channel, DarkSide-20k and Argo have the potential to discover supernova bursts throughout our galaxy and up to the Small Magellanic Cloud, respectively, assuming a 11-M progenitor star. In this work, we report also on the sensitivity to the neutronization burst, whose electron neutrino flux is suppressed by oscillations when detected via charged current and elastic scattering. Finally, the accuracies in the reconstruction of the average and total neutrino energy in the different phases of the supernova burst, as well as its time profile, are also discussed, taking into account the expected background and the detector response.

79 ASTRONOMY AND ASTROPHYSICS↗

$\mathcal{g}$ modes of neutron stars with hadron-to-quark crossover transitions

Here we perform the first study of the principal core g-mode oscillation in hybrid stars containing quark matter, utilizing a crossover model for the hadron-to-quark transition inspired by lattice QCD. The ensuing results are compared with our recent findings of g-mode frequencies in hybrid stars with a first-order phase transition using Gibbs constructions. We find that models using Gibbs construction yield g-mode amplitudes and the associated gravitational energy radiated that dominate over those of the chosen crossover model owing to the distinct behaviors of the equilibrium and adiabatic sound speeds in the various models. Based on our results, we conclude that were g modes to be detected in upgraded LIGO and Virgo detectors it would indicate a first-order phase transition akin to a Gibbs construction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗