Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Understanding and controlling capsule symmetry in near vacuum hohlraums at the National Ignition Facility

The near vacuum hohlraum platform is an inertial confinement fusion design at the National Ignition Facility (NIF) that uses the lowest practical density of helium gas of 30 μg/cc to fill the hohlraum, which is ten times lower than now used routinely. This has several advantages, such as high laser coupling; however, the inability to understand and simulate the symmetry of the imploded capsule has limited the use of this platform. This work presents the first simulations that are able to accurately capture the highly prolate implosion seen experimentally without unphysical, ad hoc model changes. While previous investigations attributed this asymmetry to multi-species interpenetration in the hohlraum, we find that this alone has little effect on symmetry. Instead, it is the presence of crossed-beam energy transfer (CBET), occurring with no applied wavelength shift between the laser beams, that increases the laser power to the inner cones and causes a more prolate implosion. The effect of CBET is increased in the simulation model when the hohlraum laser entrance hole hardware is included. Using this understanding, CBET is exploited by shifting the inner-beam wavelength by –0.75 Å (at 1ω) with respect to the outer-beams. This transfers laser power to the outer-beams in contrast to positive wavelength shifts as done routinely on NIF and produces a round capsule implosion in our simulations. Furthermore, this work shows the possibility of the near vacuum hohlraum as a viable experimental platform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an x-ray radiography platform to study laser-direct-drive energy coupling at the National Ignition Facility

A platform has been developed to study laser-direct-drive energy coupling at the National Ignition Facility (NIF) using a plastic sphere target irradiated in a polar-direct-drive geometry to launch a spherically converging shock wave. To diagnose this system evolution, eight NIF laser beams are directed onto a curved Cu foil to generate Heα line emission at a photon energy of 8.4 keV. These x rays are collected by a 100-ps gated x-ray imager in the opposing port to produce temporally gated radiographs. The platform is capable of acquiring images during and after the laser drive launches the shock wave. A backlighter profile is fit to the radiographs, and the resulting transmission images are Abel inverted to infer radial density profiles of the shock front and to track its temporal evolution. Here, the measurements provide experimental shock trajectories and radial density profiles that are compared to 2D radiation-hydrodynamic simulations using cross-beam energy transfer and nonlocal heat-transport models.

47 OTHER INSTRUMENTATION↗

High-yield magnetic recoil neutron spectrometer on the National Ignition Facility for operation up to 60 MJ

We report that recent progress at the National Ignition Facility (NIF), with neutron yields of order 1 x 10 17 , places new constraints on diagnostics used to characterize implosion performance. The Magnetic Recoil neutron Spectrometer (MRS), which is routinely used to measure yield, ion temperature (T ion ), and down-scatter ratio (dsr), has been adapted to allow measurements of dsr up to 5 x 10 17 , and yield and T ion up to 2 x 10 18 in the near term with new data processing techniques and conversion foil solutions. This paper presents a solution for extending MRS operation up to a yield of 2 x 10 19 (60 MJ) by moving the spectrometer outside of the NIF shield wall. This will not only enhance the upper yield limit by 10x but also improve signal-to-background by 5x.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray source characterization and sample heating on x-ray diffraction experiments at the National Ignition Facility

X-ray diffraction is a powerful measurement technique for determining material properties, and it is now possible to perform these experiments at pressures exceeding 1 TPa [Rygg et al., Rev. Sci. Instrum. 91, 043902 (2020)] at the National Ignition Facility (NIF). The x-ray source for these experiments is the quasi-monochromatic Heα emission from metal foils heated to multi-keV temperatures. A critical aspect for understanding the sample's thermodynamic state is the amount of heating caused by absorption of the probe x-rays. In this work, we characterize the performance of the Ge foil x-ray source over more than 60 NIF x-ray diffraction experiments. We use this information to constrain the level of diffraction sample heating from the x-ray source and discuss the impact on the thermodynamic state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

The Vacuum Cherenkov Detector (VCD) for γ-ray measurements in inertial confinement fusion experiments

Inertial confinement fusion experiments at both the National Ignition Facility (NIF) and the Laboratory for Laser Energetics OMEGA laser facility currently utilize Cherenkov detectors, with fused silica as the Cherenkov medium. At the NIF, the Quartz Cherenkov Detectors improve the precision of neutron time-of-flight measurements; and at OMEGA, the Diagnostic for Areal Density provides measurements of capsule shell areal densities. An inherent property of fused silica is the radiator’s relatively low energy threshold for Cherenkov photon production (E threshold < 1 MeV), making it advantageous over gas-based Cherenkov detectors for experiments requiring low-energy γ detection. The Vacuum Cherenkov Detector (VCD) has been specifically designed for efficient detection of low energy γ’s. Its primary use is in implosion experiments, which will study reactions relevant to stellar and big-bang nucleosynthesis, such as T( 4 He,γ) 7 Li, 4 He( 3 He,γ) 7 Be, and 12 C(p,γ) 13 N. Further, the VCD is compatible with LLE’s standard Ten-Inch Manipulator diagnostic insertion module. This work will outline the design and characterization of the VCD as well as provide results from recent experiments conducted at the OMEGA laser facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of a 1D-imaging high-energy x-ray backlighter driven by the National Ignition Facility Advanced Radiographic Capability laser

Plastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al., Rev. Sci. Instrum. 89, 10G118 (2018) and C. M. Huntington et al., Rev. Sci. Instrum. 89, 10G121 (2018)]. Alternatively, a dysprosium “micro-flag” target driven by the Advanced Radiographic Capability laser (~2 kJ, 10 ps) can deliver significantly higher spatiotemporal resolution [M. P. Hill et al., Rev. Sci. Instrum. 92, 033535 (2021)], especially in high-opacity samples. Here, initial experiments revealed problematic brightness and spectral gradients from this source, but by radiographing a set of diamond-turned, 105 µm-thick Pb test objects and supported by simulations using the 3D Monte Carlo code GEANT4, these geometry-dependent gradients across the field of view are quantified and mitigation strategies are assessed. In addition to significantly enhancing the modulation transfer function compared to the existing system, image stacking from multiple layers of image plate is shown to almost double the signal to noise ratio that will reduce uncertainties in future dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Optimized x-ray emission from 10 ns long germanium x-ray sources at the National Ignition Facility

This study investigates methods to optimize quasi-monochromatic, ~10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 10 15 W/cm 2 , optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. Here, we discuss methods to optimize the source to maintain a uniform XRS for ~10 ns, mitigating cold plasma and higher energy x-ray emission lines.

47 OTHER INSTRUMENTATION↗

First bromine doped cryogenic implosion at the National Ignition Facility

We report on the first experiment dedicated to the study of nuclear reactions on dopants in a cryogenic capsule at the National Ignition Facility (NIF). This was accomplished using bromine doping in the inner layers of the CH ablator of a capsule identical to that used in the NIF shot N140520. The capsule was doped with 3 × 1016 bromine atoms. The doped capsule shot, N170730, resulted in a DT yield that was 2.6 times lower than the undoped equivalent. The Radiochemical Analysis of Gaseous Samples (RAGS) system was used to collect and detect 79Kr atoms resulting from energetic deuteron and proton ion reactions on 79Br. RAGS was also used to detect 13N produced dominantly by knock-on deuteron reactions on the 12C in the ablator. High-energy reaction-in-flight neutrons were detected via the 209Bi(n,4n)206Bi reaction, using bismuth activation foils located 50 cm outside of the target capsule. The robustness of the RAGS signals suggests that the use of nuclear reactions on dopants as diagnostics is quite feasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven ramp-compression experiments on the national ignition facility

This report details the analyses and related uncertainties in measuring longitudinal-stress–density paths in indirect laser-driven ramp equation-of-state (EOS) experiments. Experiments were conducted at the National Ignition Facility (NIF) located at the Lawrence Livermore National Laboratory. The NIF can deliver up to 2 MJ of laser energy over 30 ns and provide the necessary laser power and control to ramp compress materials to TPa pressures (1 TPa = 10 × 10 6 atmospheres). These data provide low-temperature solid-state EOS data relevant to the extreme conditions found in the deep interiors of giant planets. In these experiments, multi-stepped samples with thicknesses in the range of 40–120 µm experience an initial shock compression followed by a time-dependent ramp compression to peak pressure. Interface velocity measurements from each thickness combine to place a constraint on the Lagrangian sound speed as a function of particle velocity, which in turn allows for the determination of a continuous stress–density path to high levels of compressibility. In this report, we present a detailed description of the experimental techniques and measurement uncertainties and describe how these uncertainties combine to place a final uncertainty in both stress and density. Here, we address the effects of time-dependent deformation and the sensitivity of ramp EOS techniques to the onset of phase transformations.

47 OTHER INSTRUMENTATION↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

Measurement of mix at the fuel–ablator interface in indirectly driven capsule implosions on the National Ignition Facility

The interface between the capsule ablator and fuel ice layer is susceptible to hydrodynamic instabilities. The subsequent mixing of hot ablator material into the ice reduces fuel compression at stagnation and is a candidate for reduced capsule performance. The ability to diagnose ice–ablator mix is critical to understanding and improving stability at this interface. Combining the crystal backlighter imager with the single line of sight camera on the National Ignition Facility (NIF) allows direct measurement of ice–ablator mix by providing multiple quasi-monochromatic radiographs of layered capsule implosions per experiment with high spatial (∼12 μm) and temporal (∼35 ps) resolution. The narrow bandwidth of this diagnostic platform allows radiography of the inner edge of the capsule limb close to stagnation without capsule self-emission contaminating the data and removes opacity uncertainties typically associated with the spectral content of the radiograph. Analysis of radiographic data via a parameterized forward-fitting Abel inversion technique provides measurements of the distribution of mix mass inwards from the ice–ablator interface. The sensitivity of this mix measurement technique was demonstrated by applying it to layered experiments in which the stability of the ice–ablator interface was expected to vary significantly. Additional experiments suggest that high-density carbon capsules that employ a buried-layer dopant profile suffer from mixing at the innermost doped–undoped interface. Data from these experiments suggest that opacity models used in hydrodynamic simulations of NIF experiments can potentially over-predict the opacity of doped capsules. LLNL-JRNL-850535-DRAFT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling stimulated Brillouin backscatter from outer-cone quads across multiple inertial confinement fusion hohlraum designs

Stimulated Brillouin scattering (SBS) is a potential risk for laser damage in the experiments carried out at the National Ignition Facility (NIF), and by altering the energy deposition pattern in hohlraums, it affects the symmetry of indirect-drive inertial confinement fusion implosions. We have surveyed backward SBS on outer-cone quads across NIF integrated hohlraums of various platforms numerically, using three-dimensional (3D) simulations with the backscatter code pF3D [Berger et al. Phys. Plasmas 5, 4337 (1998)] and ray-based gain calculations. Simulated reflected powers and energies, as well as the spectrum of reflected light all compare favorably with measurements. Ray-based calculations of exponential SBS amplification (“gain”), which assume a strongly damped plasma wave and steady-state response, are performed using a novel method that includes the 3D speckled field of the laser that drives SBS. This approach is useful for understanding qualitative differences between hohlraum designs and identifying regions susceptible to SBS within hohlraums. Quantitatively, gains are not found to correlate with SBS reflectivities in 3D, necessitating fully wave-based calculations that naturally include diffraction and various temporal dependencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of alpha-ion stopping on ignition and ignition criteria in inertial confinement fusion experiments

With the advent of ignited plasmas at the National Ignition Facility (NIF), alpha physics has become a driving factor in theoretical understanding and experimental behavior. In this communication, we explore aspects of direct alpha-ion heating through comparison of the consequences from the one-fluid and two-fluid models in the hydrodynamic approach. We show that the case with all alpha energy deposited in electrons raises the ignition criteria by ∼4 keV or ∼0.2 g/cm2 in the hotspot relative to the case with all alpha energy deposited in ions. In the case of the recently ignited NIF implosion, 30% of the 3.5 MeV α energy is deposited into the DT fuel ions, for which there is negligible difference between the one-fluid and two-fluid ignition criteria. However, changes in the ion stopping fraction through profile effects and alternate stopping power models could lead to ignition curve shifts of ∼1 keV.

Physics↗

Optimization of the gamma reaction history diagnostic for double-shell pusher areal density and reaction history measurements on the National Ignition Facility

The double-shell inertial confinement fusion campaign, which consists of an aluminum ablator, a foam cushion, a high-Z pusher (tungsten or molybdenum), and liquid deuterium–tritium (DT) fuel, aims for its first DT filled implosions on the National Ignition Facility (NIF) in 2024. The high-Z, high density pusher does not allow x-rays to escape the double-shell capsule. Therefore, nuclear diagnostics such as the Gamma Reaction History (GRH) diagnostic on the NIF are crucial for understanding high-Z implosion performance. To optimize the GRH measurement of fusion reaction history and the pusher’s areal density, the MCNP6.3-based forward model of the detector was built. When calculating the neutron-induced inelastic gamma ray production, the interaction of neutrons with the compressed fuel was additionally included. By folding the calculated gamma ray spectrum output and the previously calibrated GRH detector responses, the optimum set of GRH energy thresholds for measuring the pusher areal density is determined to be 2.9 and 6.3 MeV for DT double-shell experiments. In addition, the effect of the down-scattering of neutrons on the gamma ray spectrum, the minimum required yield for measurements, and the attenuation of the gamma rays through the pusher are analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling ablator defects as a source of mix in high-performance implosions at the National Ignition Facility

Recent indirect drive inertial confinement fusion implosions on the National Ignition Facility (NIF) [Spaeth et al., Fusion Sci. Technol. 69, 25 (2016)] have crossed the threshold of ignition. However, performance has been variable due to several factors. One of the leading sources of variability is the quality of the high-density carbon (HDC) shells used as ablators in these experiments. In particular, these shells can have a number of defects that have been found to correlate with the appearance of ablator mix into the hot spot and a degradation in nuclear yield. These defects include pits on the ablator surface, voids in the ablator bulk, high-Z debris from the Hohlraum wall that adheres to the capsule surface, and finally the inherent granular micro-structure of the crystalline HDC itself. This paper summarizes high-resolution modeling of each of these mix sources in two recent high-performance NIF implosion experiments. The simulated impact from a range of individual capsule defects is found to be broadly consistent with the trends seen in experiment, lending credence to the modeling results and the details of the mixing process that they reveal. Interestingly, modeling of the micro-structure inherent to HDC shows that this perturbation source results in considerable mixing of the deuterium–tritium fuel with ablator material during the implosion. The reduction in fuel compression from this mix results in an approximately factor of two reduction in neutron yield in current implosions and emphasizes the importance of mitigating this significant performance degradation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulated signatures of ignition

Ignition on the National Ignition Facility (NIF) provides a novel opportunity to evaluate past data to identify signatures of capsule failure mechanisms. We have used new simulations of high-yield implosions as well as some from past studies in order to identify unique signatures of different ignition failure mechanisms: jetting due to the presence of voids or defects, jetting due to the capsule fill tube, interfacial mixing due to instabilities or due to plasma transport, radiative cooling due to the presence of contaminant in the hot spot, long-wavelength drive asymmetry, and preheat. Many of these failure mechanisms exhibit unique trajectories that can be distinguished through variations in experimental observables such as neutron yield, down-scattered ratio (DSR), and burn width. Our simulations include capsules using both plastic and high-density carbon ablators and span all high-yield designs considered since the beginning of the National Ignition Campaign in 2011. We observe that the variability in trajectories through the space of neutron yield, DSR, and burn width varies little across capsule design yet are unique to the failure mechanism. The experimental trajectories are most consistent with simulated preheat and jetting due to voids and defects, which are the only failure mechanisms that are indistinguishable in our analysis. This suggests that improvements to capsule compression due to improved capsule quality or reduced preheat have played a primary role in enabling high yields on NIF. Furthermore, our analysis suggests that further improvements have the potential to increase yields further.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗