Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiple Errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

BayFlux: A Bayesian method to quantify metabolic Fluxes and their uncertainty at the genome scale

Metabolic fluxes, the number of metabolites traversing each biochemical reaction in a cell per unit time, are crucial for assessing and understanding cell function. 13 C Metabolic Flux Analysis ( 13 C MFA) is considered to be the gold standard for measuring metabolic fluxes. 13 C MFA typically works by leveraging extracellular exchange fluxes as well as data from 13 C labeling experiments to calculate the flux profile which best fit the data for a small, central carbon, metabolic model. However, the nonlinear nature of the 13 C MFA fitting procedure means that several flux profiles fit the experimental data within the experimental error, and traditional optimization methods offer only a partial or skewed picture, especially in “non-gaussian” situations where multiple very distinct flux regions fit the data equally well. Here, we present a method for flux space sampling through Bayesian inference (BayFlux), that identifies the full distribution of fluxes compatible with experimental data for a comprehensive genome-scale model. This Bayesian approach allows us to accurately quantify uncertainty in calculated fluxes. We also find that, surprisingly, the genome-scale model of metabolism produces narrower flux distributions (reduced uncertainty) than the small core metabolic models traditionally used in 13 C MFA. The different results for some reactions when using genome-scale models vs core metabolic models advise caution in assuming strong inferences from 13 C MFA since the results may depend significantly on the completeness of the model used. Based on BayFlux, we developed and evaluated novel methods (P- 13 C MOMA and P- 13 C ROOM) to predict the biological results of a gene knockout, that improve on the traditional MOMA and ROOM methods by quantifying prediction uncertainty.

59 BASIC BIOLOGICAL SCIENCES↗

Solving Inverse Radiation Transport Problems with Multi-Sensor Data in the Presence of Correlated Measurement and Modeling Errors

Inverse radiation transport focuses on identifying the configuration of an unknown radiation source given its observed radiation signatures. The inverse problem is traditionally solved by finding the set of transport model parameter values that minimizes a weighted sum of the squared differences by channel between the observed signature and the signature predicted by the hypothesized model parameters. The weights are inversely proportional to the sum of the variances of the measurement and model errors at a given channel. The traditional implicit (often inaccurate) assumption is that the errors (differences between the modeled and observed radiation signatures) are independent across channels. Here, an alternative method that accounts for correlated errors between channels is described and illustrated using an inverse problem based on the combination of gamma and neutron multiplicity counting measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

Multi-calculation rate simulations

It is common in real time simulations of large aerospace systems to separate the high and low frequency subsystems within the simulation and perform the integrations of the subsystems at different calculation rates. This is done to strike a balance between accuracy of calculation and capacity of the digital computer. Questions arising as to the accuracy of this structure compared to single calculation rates were studied using a linear aircraft model. Also investigated were interactions arising to cause errors worse than those expected. Problems are specifically identified and guidelines are given for selection of sample rates for multiple rate simulations.

Powell, J. D.↗

Monthly mean simulation experiments with a course-mesh global atmospheric model

Substitution of observed monthly mean sea-surface temperatures (SSTs) as lower boundary conditions, in place of climatological SSTs, failed to improve the model simulations. While the impact of SST anomalies on the model output is greater at sea level than at upper levels the impact on the monthly mean simulations is not beneficial at any level. Shifts of one and two days in initialization time produced small, but non-trivial, changes in the model-generated monthly mean synoptic fields. No improvements in the mean simulations resulted from the use of either time-averaged initial data or re-initialization with time-averaged early model output. The noise level of the model, as determined from a multiple initial state perturbation experiment, was found to be generally low, but with a noisier response to initial state errors in high latitudes than the tropics.

Spar, J.↗

Documentation for the machine-readable version of the SAO-HD-GC-DM cross index version 1983

An updated and extended machine readable version of the Smithsonian Astrophysical Observatory star catalog (SAO) is described. A correction of all errors which were found since preparation of the original catalog which resulted from misidentifications and omissions of components in multiple star systems and missing Durchmusterung numbers (the common identifier) in the SAO Catalog are included and component identifications from the Index of Visual Double Stars (IDS) are appended to all multiple SAO entries with the same DM numbers, and lower case letter identifiers for supplemental BD stars are added. A total of 11,398 individual corrections and data additions is incorporated into the present version of the cross index.

Roman, N. G.↗

A reliable pipelining protocol for the message service of the Mobile Satellite Experiment

This paper describes and analyzes a pipelining protocol for the data message communications of MSAT-X, a proposed experimental satellite-based mobile communications network. A demand assigned multiple access protocol using pure ALOHA for making reservation requests has been developed for MSAT-X under error-free assumptions. Preliminary propagation studies indicate that the short term bit error rate of satellite channels in a mobile environment can be as high as 0.001. Therefore, error-control schemes must be developed to ensure reliable transmissions. A retransmission scheme using selective repeat to minimize the end-to-end delay is proposed. Slotted ALOHA for making reservation requests is used to increase the overall system throughput. Since the number of channels available for reservation and data channels is essentially fixed for a given voice call blocking probability and a fixed call arrival rate, the analysis presented in this paper is also applicable to the integrated voice and data services of MSAT-X. Various operational scenarios have been investigated.

Li, V. O. K.↗

Satellite altimeter calibration techniques

This paper examines calibration techniques which can most effectively satisfy the requirements of future satellites carrying high-accuracy radar altimeters, such as the ESA ERS-1 and the NASA/CNES Topex/Poseidon satellites scheduled for launch during the next five years. The calibration accuracies and the advantages and disadvantages of the four currently proposed calibration techniques for over-water calibration are discussed: (1) a tide gauge on a tower at-sea and a nearby laser, (2) a laser and a tide gauge on an island with an offshore satellite pass and a geoid tie between the satellite ground track and the laser, (3) a tide gauge on a tower at-sea with satellite positioning from multiple lasers and a GPS, and (4) a laser and a tide gauge on a tower at-sea. Error budgets for these techniques, developed on the basis of state-of-the-art tracking systems, were found to have one sigma height uncertainties in the 2.8 to 4.9 cm range.

Kolenkiewicz, R.↗

Satellite mapping of Nile Delta coastal changes

Multitemporal, multispectral scanner (MSS) landsat data have been used to monitor erosion and sedimentation along the Rosetta Promontory of the Nile Delta. These processes have accelerated significantly since the completion of the Aswan High Dam in 1964. Digital differencing of four MSS data sets, using standard algorithms, show that changes observed over a single year period generally occur as strings of single mixed pixels along the coast. Therefore, these can only be used qualitatively to indicate areas where changes occur. Areas of change recorded over a multi-year period are generally larger and thus identified by clusters of pixels; this reduces errors introduced by mixed pixels. Satellites provide a synoptic perspective utilizing data acquired at frequent time intervals. This permits multiple year monitoring of delta evolution on a regional scale.

Blodget, H. W.↗

Two wavelength satellite laser ranging using SPAD

When ranging to satellites with lasers, there are several principal contributions to the error budget: from the laser ranging system on the ground, from the satellite retroarray geometry, and from the atmosphere. Using a single wavelength, we have routinely achieved a ranging precision of 8 millimeters when ranging to the ERS-1 and Starlette satellites. The systematic error of the atmosphere, assuming the existing dispersion models, is expected to be of the order of 1 cm. Multiple wavelengths ranging might contribute to the refinement of the existing models. Taking into account the energy balance, the existing picosecond lasers and the existing receiver and detection technology, several pairs or multiple wavelengths may be considered. To be able to improve the atmospheric models to the subcentimeter accuracy level, the differential time interval (DTI) has to be determined within a few picoseconds depending on the selected wavelength pair. There exist several projects based on picosecond lasers as transmitters and on two types of detection techniques: one is based on photodetectors, like photomultipliers or photodiodes connected to the time interval meters. Another technique is based on the use of a streak camera as an echo signal detector, temporal analyzer, and time interval vernier. The temporal analysis at a single wavelength using the streak camera showed the complexity of the problem.

Prochazka, Ivan↗

Five-Hole Flow Angle Probe Calibration for the NASA Glenn Icing Research Tunnel

A spring 1997 test section calibration program is scheduled for the NASA Glenn Research Center Icing Research Tunnel following the installation of new water injecting spray bars. A set of new five-hole flow angle pressure probes was fabricated to properly calibrate the test section for total pressure, static pressure, and flow angle. The probes have nine pressure ports: five total pressure ports on a hemispherical head and four static pressure ports located 14.7 diameters downstream of the head. The probes were calibrated in the NASA Glenn 3.5-in.-diameter free-jet calibration facility. After completing calibration data acquisition for two probes, two data prediction models were evaluated. Prediction errors from a linear discrete model proved to be no worse than those from a full third-order multiple regression model. The linear discrete model only required calibration data acquisition according to an abridged test matrix, thus saving considerable time and financial resources over the multiple regression model that required calibration data acquisition according to a more extensive test matrix. Uncertainties in calibration coefficients and predicted values of flow angle, total pressure, static pressure. Mach number. and velocity were examined. These uncertainties consider the instrumentation that will be available in the Icing Research Tunnel for future test section calibration testing.

Gonsalez, Jose C.↗

New Integrated Modeling Capabilities: MIDAS' Recent Behavioral Enhancements

The Man-machine Integration Design and Analysis System (MIDAS) is an integrated human performance modeling software tool that is based on mechanisms that underlie and cause human behavior. A PC-Windows version of MIDAS has been created that integrates the anthropometric character "Jack (TM)" with MIDAS' validated perceptual and attention mechanisms. MIDAS now models multiple simulated humans engaging in goal-related behaviors. New capabilities include the ability to predict situations in which errors and/or performance decrements are likely due to a variety of factors including concurrent workload and performance influencing factors (PIFs). This paper describes a new model that predicts the effects of microgravity on a mission specialist's performance, and its first application to simulating the task of conducting a Life Sciences experiment in space according to a sequential or parallel schedule of performance.

Gore, Brian F.↗

Single-Command Approach and Instrument Placement by a Robot on a Target

AUTOAPPROACH is a computer program that enables a mobile robot to approach a target autonomously, starting from a distance of as much as 10 m, in response to a single command. AUTOAPPROACH is used in conjunction with (1) software that analyzes images acquired by stereoscopic cameras aboard the robot and (2) navigation and path-planning software that utilizes odometer readings along with the output of the image-analysis software. Intended originally for application to an instrumented, wheeled robot (rover) in scientific exploration of Mars, AUTOAPPROACH could be adapted to terrestrial applications, notably including the robotic removal of land mines and other unexploded ordnance. A human operator generates the approach command by selecting the target in images acquired by the robot cameras. The approach path consists of multiple legs. Feature points are derived from images that contain the target and are thereafter tracked to correct odometric errors and iteratively refine estimates of the position and orientation of the robot relative to the target on successive legs. The approach is terminated when the robot attains the position and orientation required for placing a scientific instrument at the target. The workspace of the robot arm is then autonomously checked for self/terrain collisions prior to the deployment of the scientific instrument onto the target.

Huntsberger, Terrance↗

GOES-17 Magnetometer On-Orbit Calibration Design and Results

The Geostationary Operational Environmental Satellite-R (GOES-R) is a series of four NOAA weather satellites. Each spacecraft flies a Magnetometer instrument which includes two boom mounted fluxgate sensors located 6.3 and 8.5 meters from the spacecraft. Sensor readings are corrupted by both internal (bias and scale factor) and external (spacecraft emitted fields and misalignments) error sources. In order to estimate the bias, an on-orbit calibration is performed, slewing the spacecraft about multiple axes and then performing a fit of the data to determine zero offset and misalignment terms. The first satellite in the series, GOES-16 was launched in November 2016. Its magnetometer calibration maneuver was found to be inadequate providing insufficient rotation about orthogonal axes. The uncertainty in the estimated biases was found to be in the 3-5 nanotesla range, exceeding the magnetometer accuracy requirement of 1.0 nanotesla. Based on lessons learned, the maneuver was redesigned to provide multiple 360 degree rotations about two orthogonal axes, providing optimal visibility into bias and misalignment. Varying ambient fields over the duration of the calibration maneuvers, corrupts the ability to accurately determine parameters of interest. To address this issue, rather than assuming a constant field for the duration of the maneuver, a non-linear least squares filter was employed that uses a series of spline functions to better fit the ambient field. The number of splines can be varied to minimize the least squares filter residuals. Simulations were performed using 360 days of GOES-16 data to bound the uncertainty in the biases for given residuals of the fit to the ambient field. Following the launch of the second satellite in the series, GOES-17 in March 2018, the new calibration maneuver and enhanced bias estimation algorithm were exercised twice. Based on the residuals of the fit, the uncertainty of the estimated zero offset was reduced by an order of magnitude from 3-5 nanotesla to approximately 0.4 nanotesla per axis. This paper provides details of the maneuver design and the innovative algorithm used to estimate the GOES-17 biases and misalignments.

GOES-17↗

SORCE and TSIS-1 SIM Comparison: Absolute Irradiance Scale Reconciliation

The Solar Radiation and Climate Experiment (SORCE) and Total and Spectral Irradiance Sensor (TSIS-1) conducted an intercomparison for the two Spectral Irradiance Monitors (SIM) spanning 704 days from 23 March 2018 to 25 February 2020 and permitted 554 time-matched pairs of observations. This comparison was conducted during the extremely quiescent Solar Cycle 24 minimum, so all observed differences and drifts between the two sensors are instrumental in nature. The TSIS-1 SIM benefitted from advanced calibration capabilities based on SI standards that were not available during the preflight calibration time period of SORCE. For this reason, a revision of the SORCE SIM absolute scale is appropriate. As expected, wavelength dependent differences in absolute agreement are a function of detector sensitivity and local changes in spectral slope. At the time of the comparison SORCE SIM has been on-orbit for 17 years while TSIS-1 observations commenced immediately after a 100-day outgassing and commissioning period. Peak-to-peak absolute scale differences are about 12% with a mean fractional difference of 0.7% ± 2.9%. The greatest scale differences occur at the change-over between the UV and visible photodiodes in the 310 nm region, and a systematic disagreement is present in the 850–1,600 nm range. A multiplicative scale correction factor has been developed to reconcile the TSIS-1 and SORCE difference with a wavelength dependent error on the mean typically less than 0.01% derived from every matched pair of observations.

Jerald Harder↗

Advanced Power-Hardware-in-the-Loop Evaluation of Inverter-Based Resources (IBRs)

Power-hardware-in-the-loop evaluation of IBRs has become more and more important as it provides reliable testing results to investigate the real responses of inverters with interconnected systems. A successful laboratory PHIL testing gives confidence of the hardware system to be deployed and de-risk technology integration prior to field deployment. So far, there are two important applications for PHIL evaluation: (1) test stability and functionality of large utility inverters into the system when it interconnects to the distribution systems/microgrids; and (2) test the collective grid service that inverters can provide to the grid. For the first application, the PHIL evaluation has high requirements for the stability and accuracy of the PHIL interface as the close-loop in digital real time simulator (DRTS) should replicate the actual current and voltage dynamics in the inverter. This is challenging because of the delays, sensing errors, nonlinearities of inverters, and hardware bandwidth limitations of the elements in the HIL loop. For the second application, multiple inverters will be tested resulting in multiple PCCs, which naturally causes competing dynamics and oscillations among hardware inverters if traditional PHIL interface is used. Therefore, new PHIL interface should be developed to compromise between stability and accuracy and represent the dispatched grid services for the hardware inverters. In this presentation, we will share our latest work in developing PHIL interface in these two applications to address the two key challenges.

DERMS↗

Analyzing the Calibration History of Radiometers for Determining Optimal Calibration Day(s)

This study investigates the effects of calibrating radiometers using one day or multiple cloudless days as recommended by ASTM and ISO standards. The results demonstrate good responsivity agreement with estimated uncertainty error bars over the years for various radiometers under various Broadband Outdoor Radiometer Calibration (BORCAL) events at both the National Renewable Energy Laboratory and the Southern Great Plains facility. The BORCAL method appears to justify the use of a single calibration day with enough data points to attain repeatable calibration results.

BORCAL↗

Reactivity Coefficient Measurements to Aid in Reducing Compensating Errors in Plutonium Nuclear Data

Compensating errors between several nuclear data observables in a nuclear data library can adversely impact application simulations. The primary goal of the EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) is to reduce compensating errors between fast (0.1–5 MeV) 239Pu nuclear data for prompt fission neutron spectra (PFNS), average prompt fission neutron multiplicities, and neutron induced fission, capture, elastic, and inelastic cross sections. This work will focus on the design and execution of void reactivity coefficient measurements in the EUCLID experiment, performed on the Planet vertical lift critical assembly machine at the National Criticality Experiments Research Center (NCERC). Two different base configurations were designed and measured, one with high neutron leakage, and one with low neutron leakage. Both were primarily made up of plutonium metal (Zero Power Physics Reactor plates) without interstitial moderators and reflected by half-inch aluminum. Design optimization showed that void reactivity coefficient measurements in three locations per configuration was most impactful to reduce nuclear data uncertainties due to the varying impacts from elastic and inelastic scattering, as well as fission and capture. The locations for measurements were chosen based on preliminary studies which balanced measurement uncertainty and measurement practicality. The measurements were also selected to have sensitivities maximally complementary to previous arrangements. Comparisons across nuclear data libraries highlight the potential impact.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗