Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Comparison of experimental rotor damping data-reduction techniques

The ability of existing data reduction techniques to determine frequency and damping from transient time-history records was evaluated. Analog data records representative of small-scale helicopter aeroelastic stability tests were analyzed. The data records were selected to provide information on the accuracy of reduced frequency and decay coefficients as a function of modal damping level, modal frequency, number of modes present in the time history record, proximity to other modes with different frequencies, steady offset in time history, and signal-to-noise ratio. The study utilized the results from each of the major U.S. helicopter manufacturers, the U.S. Army Aeroflightdynamics Directorate, and NASA Ames Research Center using their inhouse data reduction and analysis techniques. Consequently, the accuracy of different data analysis techniques and the manner in which they were implemented were also evaluated. It was found that modal frequencies can be accurately determined even in the presence of significant random and periodic noise. Identified decay coefficients do, however, show considerable variation, particularly for highly damped modes. The manner in which the data are reduced and the role of the data analyst was shown to be important. Although several different damping determination methods were used, no clear trends were evident for the observed differences between the individual analysis techniques. It is concluded that the data reduction of modal-damping characteristics from transient time histories results in a range of damping values.

Warmbrodt, William↗

Thermal Versus Impedance-Based Ablation of Renal Cell Carcinoma: A Meta-analysis

Background: Percutaneous radiofrequency ablation (RFA) of renal carcinoma has become an established treatment modality. However, thermal (TB) versus impedance-based (IB)-RF generators have not been previously compared. Methods: A literature search on the application of RFA for renal masses using TB or IB-RF generators was performed. The safety, efficacy, and long-term outcomes of TB versus IB-based RFA were assessed using the outcome measures of technical success, local recurrence rate, complications, and preservation of renal function. Results: Across the 27 included studies, pooled results suggested comparable results for technical success (TB-RFA 98.53 % vs. IB-RFA 98.78 %, P = 0.9813). Clinical efficacy results were also similar across both generators (91.0 % TB-RFA vs. 91.5 % IB-RFA; P = 0.73). At follow-up, no differences in renal function (relative risk [RR] 0.5, 95 % confidence interval [CI] 0.45–5.48), and local recurrence (RR 0.717, 95 % CI 0.49–1.50) were observed. The pooled proportion of overall complication rates was 13.1 % for TB-RFA and 11.5 % for IB-RFA. Conclusion: No differences in the observed parameters were found either during surgery or at follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multishaker Modal Testing

Report prepared for Marshall Space Flight Center summarizes recent advances in mathematical analysis of structural vibrations based on experimental data. Also includes summary of research by author as well as abstracts of technical reports and papers presented at meetings or otherwise published.

Graig, R. R., Jr.↗

Open Science for Life in Space: Data Sharing and Tools for Knowledge Discovery

The next era in human space exploration is rapidly approaching. The use of health countermeasures and biomonitoring systems for space missions are required to counteract space health hazards and to support life to thrive in deep space (e.g., humans, animals, plants, crops; entire ecosystems within spacecrafts/habitats/spacesuits). The development of these mission components will be highly dependent on our understanding of basic biological and health responses to myriad space hazards (ionizing radiation, altered gravitational fields, altered day-night cycles, confined isolation, hostile-closed environments, distance-duration from Earth, planetary dust-regolith, and extreme temperatures/atmospheres). The fast-growing array of space biological and mission telemetry data, which in the past was simply archived after minimal analysis, holds great potential once applied to these mission challenges if it can be reorganized and formatted for Open Science. Organizing the data for such analysis is a challenge because of its multi-hierarchical, multi-modal, and heterogenous nature (molecular, cellular, tissue, organ, whole organism, behavior, ecosystem, microbiome; tabular, omics, imaging, video, biospecimen, environmental physical-chemical telemetry). This session focuses on current approaches in this domain such as: making space biological data FAIR (findable, accessible, interoperable, reusable), effective data ingestion/dissemination, observational versus experimental data, Open Science collaborations, data analysis techniques, AI/ML/knowledge graph/modeling methods, and data integration/discovery tools.

open science↗

The Effect of Laser Cutting Heuristic Presentation Modality on Design Learning

Abstract The goal of this work is to study the way student designers use heuristics to effectively design for laser-cut manufacturing methods. With the recent advent of academic makerspaces, digital fabrication tools like laser cutters are relatively new additions to the classroom. Therefore, there is a gap in formal education or training on these tools, and students can find it challenging to design effectively for them. A study was performed to investigate the way students apply heuristics to redesign laser-cut assemblies when received in different modalities. All participants were given an identical lecture on laser cutting heuristics. Then, a redesign problem was presented to students, and three different experimental groups were given the heuristics in different modalities: Text-Only, text with Visual aids, and text with Tactile aids. The novelty and quality of each of the resulting redesigns were evaluated. It was hypothesized that participants would have more difficulty interpreting and applying the Text-Only heuristics, lowering the quality of their redesigned solutions relative to the other two conditions. It was also hypothesized that participants would experience fixation caused by interacting with the tactile aids, leading to the lower novelty of their redesigned solutions relative to the other two conditions. Results showed that modality played a significant role in participants’ feelings of self-efficacy after the intervention, as well as in their understanding of laser cutter design skills when responding to quiz-style questions. However, analysis of novelty and quality showed little significant impact of the intervention and varying modalities on participants’ designs.

Engineering↗

Management of Pediatric Myxopapillary Ependymoma: The Role of Adjuvant Radiation

Introduction: Myxopapillary ependymoma (MPE) is a rare tumor in children. The primary treatment is gross total resection (GTR), with no clearly defined role for adjuvant radiation therapy (RT). Published reports, however, suggest that children with MPE present with a more aggressive disease course. The goal of this study was to assess the role of adjuvant RT in pediatric patients with MPE. Methods: Sixteen patients with MPE seen at Johns Hopkins Hospital (JHH) between November 1984 and December 2010 were retrospectively reviewed. Fifteen of the patients were evaluable with a mean age of 16.8 years (range, 12-21 years). Kaplan-Meier curves and descriptive statistics were used for analysis. Results: All patients received surgery as the initial treatment modality. Surgery consisted of either a GTR or a subtotal resection (STR). The median dose of adjuvant RT was 50.4 Gy (range, 45-54 Gy). All patients receiving RT were treated at the involved site. After a median follow-up of 7.2 years (range, 0.75-26.4 years), all patients were alive with stable disease. Local control at 5 and 10 years was 62.5% and 30%, respectively, for surgery alone versus 100% at both time points for surgery and adjuvant RT. Fifty percent of the patients receiving surgery alone had local failure. All patients receiving STR alone had local failure compared to 33% of patients receiving GTR alone. One patient in the surgery and adjuvant RT group developed a distant site of recurrence 1 year from diagnosis. No late toxicity was reported at last follow-up, and neurologic symptoms either improved or remained stable following surgery with or without RT. Conclusions: Adjuvant RT improved local control compared to surgery alone and should be considered after surgical resection in pediatric patients with MPE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unimodal Imaging of Monovalent Metal-Chelator Complexes and Lipids by MALDI Imaging Mass Spectrometry

Careful regulation of monovalent metal ions (M + ) is necessary to maintain a functional cellular system. Of these ions, appropriate sodium (Na + ) and potassium (K + ) concentrations are particularly integral for electrochemical signaling, as well as the secondary transport of nutrients and waste. Dysregulation of M + homeostasis can disrupt these mechanisms, potentially influencing the metabolism of downstream biomolecules such as lipids. Thus, the relationship between M + abundances and related biomolecular distributions must be elucidated to better understand the physiology of healthy and disordered tissues. Traditional techniques for imaging biological metal distributions include SIMS, LA-ICP-MS, and XRF; however, these capabilities are limited to elemental analysis or the analysis of molecular fragments and must be paired with other modalities to visualize distributions of more complex biomolecules within the same or similar samples. Conversely, matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) is a powerful tool often used for mapping such biomolecular distributions, but current methods are unable to detect metals within tissue. This study illustrates a novel methodology that adds metal detection to the MALDI IMS repertoire through which the simultaneous detection of M + metals and lipids is achievable. Using a robotic sprayer for homogeneous application, on-tissue deposition of the chelator deferiprone (DEF) enables subsequent detection of the ionizable metal-chelator complex by MALDI without hindering lipid detection. Our work provides proof-of-concept data for the simultaneous detection of K + , Na + , and intact lipids using MALDI IMS.

59 BASIC BIOLOGICAL SCIENCES↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Size and Time-Resolved Automated Aerosol Sampling Field Campaign Report

To improve the understanding of the impacts of the vertical distribution of aerosol chemical composition on radiative forcing of aerosol, we performed a detailed physicochemical characterization of aerosol particles sampled during ARM deployment of the tethered balloon system at two ARM sites. We used multi-modal microscopy/spectroscopy techniques and advanced mass spectrometry platforms for the analysis of particles. We found variations in size-resolved aerosol composition at different altitudes. We also observed changes in aerosol composition during different seasons. Some of our observations at ARM’s Oliktok Point, Alaska site suggest cloud processing of aerosol while sampling in clouds, below clouds, and above clouds.

54 ENVIRONMENTAL SCIENCES↗

A DMAP Program for the Selection of Accelerometer Locations in MSC/NASTRAN

A new program for selecting sensor locations has been written in the DMAP (Direct Matrix Abstraction Program) language of MSC/NASTRAN. The program implements the method of Effective Independence for selecting sensor locations, and is executed within a single NASTRAN analysis as a "rigid format alter" to the normal modes solution sequence (SOL 103). The user of the program is able to choose among various analysis options using Case Control and Bulk Data entries. Algorithms tailored for the placement of both uni-axial and tri- axial accelerometers are available, as well as several options for including the model s mass distribution into the calculations. Target modes for the Effective Independence analysis are selected from the MSC/NASTRAN ASET modes calculated by the "SOL 103" solution sequence. The initial candidate sensor set is also under user control, and is selected from the ASET degrees of freedom. Analysis results are printed to the MSCINASTRAN output file (*.f06), and may include the current candidate sensors set, and their associated Effective Independence distribution, at user specified iteration intervals. At the conclusion of the analysis, the model is reduced to the final sensor set, and frequencies and orthogonality checks are printed. Example results are given for a pre-test analysis of NASA s five-segment solid rocket booster modal test.

Peck, Jeff↗

Ares I-X Launch Vehicle Modal Test Overview

The first test flight of NASA's Ares I crew launch vehicle, called Ares I-X, is scheduled for launch in 2009. Ares IX will use a 4-segment reusable solid rocket booster from the Space Shuttle heritage with mass simulators for the 5th segment, upper stage, crew module and launch abort system. Flight test data will provide important information on ascent loads, vehicle control, separation, and first stage reentry dynamics. As part of hardware verification, a series of modal tests were designed to verify the dynamic finite element model (FEM) used in loads assessments and flight control evaluations. Based on flight control system studies, the critical modes were the first three free-free bending mode pairs. Since a test of the free-free vehicle is not practical within project constraints, modal tests for several configurations in the nominal integration flow were defined to calibrate the FEM. A traceability study by Aerospace Corporation was used to identify the critical modes for the tested configurations. Test configurations included two partial stacks and the full Ares I-X launch vehicle on the Mobile Launcher Platform. This paper provides an overview for companion papers in the Ares I-X Modal Test Session. The requirements flow down, pre-test analysis, constraints and overall test planning are described.

Buehrle, Ralph D.↗

Advances in Spatial Data Infrastructure, Acquisition, Analysis, Archiving and Dissemination

The authors review recent contributions to the state-of-thescience and benign proliferation of satellite remote sensing, spatial data infrastructure, near-real-time data acquisition, analysis on high performance computing platforms, sapient archiving, multi-modal dissemination and utilization for a wide array of scientific applications. The authors also address advances in Geoinformatics and its growing ubiquity, as evidenced by its inclusion as a focus area within the American Geophysical Union (AGU), European Geosciences Union (EGU), as well as by the evolution of the IEEE Geoscience and Remote Sensing Society's (GRSS) Data Archiving and Distribution Technical Committee (DAD TC).

Ramapriyan, Hampapuran K.↗

Mode Projection Method for Target Mode Identification

A method for projecting flight configuration eigenvectors onto the vector space of the test configuration eigenvectors is proposed. The underlying concept of the proposed method is that any flight configuration eigenvectors that can be replicated by a linear combination of test configuration eigenvectors, is correlated, if the constituent test eigenvectors are themselves correlated. Therefore, the modal test target mode shapes should be those test modes that combine to form the important modes of the flight configurations. This approach also recognizes that it is the deformed shapes that dictate what sections of the structure are “highly strained” (in a relative sense, within each mode shape), and that it is these highly strained sections that require an accurate stiffness representation to achieve an accurate model correlation.

Modal Testing↗

Mode Projection for Target Mode Identification

A method for projecting flight configuration eigenvectors onto the vector space of the test configuration eigenvectors is proposed. The underlying concept of the proposed method is that any flight configuration eigenvectors that can be replicated by a linear combination of test configuration eigenvectors, is correlated, if the constituent test eigenvectors are themselves correlated. Therefore, the modal test target mode shapes should be those test modes that combine to form the important modes of the flight configurations. This approach also recognizes that it is the deformed shapes that dictate what sections of the structure are “highly strained” (in a relative sense, within each mode shape), and that these “highly strained” sections require an accurate stiffness representation to achieve an accurate model correlation.

modal testing↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Computational Aeroservoelastic Analysis with an Euler-Based Unsteady Flow Solver

The effectiveness of transpiration for simulation of structural deformations in steady and unsteady aeroelastic applications is examined. The majority of the investigations were performed using a highly integrated, finite-element code for the multidisciplinary analysis of flight vehicles. A supplement to this code, which allows for the generation of deflected meshes using modal superposition, was developed in this study. This research demonstrated that the transpiration boundary condition has strong potential for applications in unsteady aeroelastic analysis, such as in the prediction of flutter boundaries.

Arena, Andrew S., Jr.↗

Evaluating the feasibility of LA-ICP-TOF-MS for the analysis of environmental particle collections

Laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) was employed to rapidly analyze environmental particle samples collected using aerosol contaminate extractors (ACE). The ACE particle collectors were placed at various distances (0.5, 1.3, and 4.5 km) from a source that released Ru-bearing particles. Samples for measurement were then generated (as sub-samples) from the ACE collection plates via particle “lift off” with gunshot residue (GSR) tabs. The LA-ICP-TOF-MS method was employed such that 10+ samples could be analyzed in a single unattended analytical session. A 3 × 1 mm area of individual GSR tab samples were analyzed in less than 30 minutes. This provided spatially resolved elemental and isotopic measurements of the particulate content and confirmed the presence of Ru-bearing particles within the complex background environmental particle loading. As anticipated, measurements showed collectors closest to the source had the highest concentration of the released Ru-bearing particles, while all collectors, regardless of distance, contained similar levels of background particles (e.g., Fe and Sr). Sequential scanning electron microscopy – automated particle analysis (SEM-APA) and LA-ICP-TOF-MS analysis was employed for method validation and a demonstration of the multi-modal approach. The same 2-dimensional region was analyzed by both methods and the particles identified via SEM-APA were also detected using LA-ICP-TOF-MS, with 100% accuracy. Overall, LA-ICP-TOF-MS demonstrated its utility for rapid elemental and isotopic particle analysis from environmental air samples.

Manard, Benjamin T. [Oak Ridge National Laboratory↗