Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Highly portable radial differential mobility analyzer

The present disclosure describes a compact and lightweight, radial-flow DMA designed to operate at low aerosol and sheath flowrates (on the order of 0.3 L/min aerosol flow, and 0.6-1.2 L/min sheath flow) and so as to classify aerosols including particles having sizes in the 10-500 nm range. Thus, the DMA is capable of operating at relatively low resolution (RND=2-4) to minimize both instrument volume and pumping/power requirements, while enabling size distribution measurement with the precision required for desired applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BeyondPlanck I. Global Bayesian analysis of the Planck Low Frequency Instrument data

We describe the BeyondPlanck project in terms of motivation, methodology and main products, and provide a guide to a set of companion papers that describe each result in fuller detail. Building directly on experience from ESA's Planck mission, we implement a complete end-to-end Bayesian analysis framework for the Planck Low Frequency Instrument (LFI) observations. The primary product is a joint posterior distribution P(omega|d), where omega represents the set of all free instrumental (gain, correlated noise, bandpass etc.), astrophysical (synchrotron, free-free, thermal dust emission etc.), and cosmological (CMB map, power spectrum etc.) parameters. Some notable advantages of this approach are seamless end-to-end propagation of uncertainties; accurate modeling of both astrophysical and instrumental effects in the most natural basis for each uncertain quantity; optimized computational costs with little or no need for intermediate human interaction between various analysis steps; and a complete overview of the entire analysis process within one single framework. As a practical demonstration of this framework, we focus in particular on low-l CMB polarization reconstruction, paying special attention to the LFI 44 GHz channel. We find evidence of significant residual systematic effects that are still not accounted for in the current processing, but must be addressed in future work. These include a break-down of the 1/f correlated noise model at 30 and 44 GHz, and scan-aligned stripes in the Southern Galactic hemisphere at 44 GHz. On the Northern hemisphere, however, we find that all results are consistent with the LCDM model, and we constrain the reionization optical depth to tau = 0.067 +/- 0.016, with a low-resolution chi-squared probability-to-exceed of 16%. The marginal CMB dipole amplitude is 3359.5 +/- 1.9 uK. (Abridged.)

Andersen, KJ↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

4. Geometry Data Storage

3D-printing begins with the design of an object using computer aided design (CAD) software. The geometry of the object must be exported and saved in a data file format that can be used in the slicing process to generate machine instructions for printing. The standard method of saving the data is to tessellate the object as a triangulated mesh stored as a .stl file. Due to the flat triangular faces used to store the data, this mesh is a low-resolution representation of the high-fidelity object designed in CAD. The STL has its limitations with respect to geometrical accuracy, material information, and instances of invalid mesh data, but can still be used for the 3D-printing process. New file variants, such as OBJ, AMF, and 3MF, are being developed to fix some of these issues and increase the capabilities of geometry data storage for 3D-printing.

Roschli, Alex↗

Poster for 12th World Conference for Neutron Radiography (WCNR-12)

Complimentary Relationships Between Neutron Computed Radiography and Digital X-ray Radiography of Radioactive Specimens The Transient Reactor Test (TREAT) Facility is a 19,000 MW reactor located at the Idaho National Laboratory which is used for transient testing of materials and experiments. A neutron radiography facility is installed which allows for low resolution neutron imaging with a capability of items up to 20 cm wide and 400 cm long. Along with the neutron radiography facility, a 370 kV digital X-ray system is located onsite for when X-ray imaging is more practical or when rapid imaging is requested. The X-ray facility can accommodate specimens up to 61 cm wide and 1000 cm long. This poster discusses the complimentary relationship between transfer-method Neutron Computed Radiography (nCR) and Digital X-ray Radiography (DR) imaging of radioactive specimens along with practical applications for nuclear fuels and materials testing programs. Both nCR and DR images were acquired of inert gas and water filled apparatus containing differing materials at varying radiation levels. Highly radioactive items have no effect on nCR image quality whereas radioactivity has varying degrees of effect in DR. Radioactive items as high as 20 mSv/h have been successfully imaged using X-ray DR methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative Insight to Fission Gas Bubble Distribution in Irradiated Annular U-10Zr Metallic Fuel Using Deep Learning

U-10Zr Metal fuel is a promising nuclear fuel candidate for next-generation sodium-cooled fast spectrum reactors. Porosity is one of the key facts to impact the performance of metallic fuel. Additionally, a mechanical understanding of fission gas bubbles evolution behavior is a prerequisite for fuel development and qualification. Previous study of fission gas bubbles relied on a simple threshold method working on low resolution optical microscopy images, which has challenges in recognizing bubble boundaries, and caused inaccurate statistics of bubble properties. In this paper, a pre-trained deep learning model on Scanning Electron Microscopy (SEM) images from an annular U-10Zr fuel (AF1), was applied to another U-10Zr annular fuel (AF2). More accurate fission gas bubble segmentation results were generated, which leads to more precise qualitative analysis on the morphology, size, density, and orientation of bubbles. Furthermore, we investigated the lanthanide movement along the radial temperature gradient and obtained conclusive findings.

36 MATERIALS SCIENCE↗

Analysis and Validation of PMT s Waveforms in ICARUS LArTPC Using Monte Carlo Simulations

ICARUS (Imaging Cosmic and Rare Underground Signals) serves as the Far Detector in the Short Baseline Neutrino (SBN) program at Fermilab, playing a central role in investigating the potential existence of sterile neutrinos in the eV squared mass range. The detector consists of two large Liquid Argon Time Projection Chambers (LArTPCs) with a total capacity of 760 tons of liquid Argon. A key component of the system is its array of 360 Photo-Multiplier Tubes (PMTs), which detect the scintillation light produced by charged particles in liquid Argon; the fast scintillation signal enables accurate event timing, triggering, and reconstruction. Together with the TPC and CRT systems, the PMTs ensure precise interaction time measurements, which are crucial for distinguishing neutrino interactions from cosmic-ray backgrounds. ICARUS uses Hamamatsu R5912-MOD PMTs, optimized for cryogenic temperatures, with high quantum efficiency, excellent timing resolution, low dark current (around 10 nA at 1500 V), and broad spectral sensitivity (300–650 nm). These characteristics are crucial for the efficient detection of scintillation light. Analyzing the waveforms of PMT signals allows for a detailed comparison between experimental data and Monte Carlo simulations. This analysis is fundamental for improving the accuracy of neutrino event reconstruction, enhancing detector calibration, and optimizing the detector's performance for current and future operations.

Brio, V. [Catania U.] (ORCID:0009000088807391)↗

Mirror Tech Days (11/02/2021)Next Generation Astronomical X-ray Optics:High Resolution, Light Weight, & Low Cost

We have demonstrated the basic elements of a technology to make high-resolution, light-weight, and low-cost X-ray optics. We continue to advance this technology to meet all requirements of Lynx: performance and programmatic. This technology uses only commercially available equipment and materials. It piggybacks on the semiconductor industry, avoiding obsolescence and ensuring continual advance. This technology can be used for missions of all sizes: sub-orbital, SmallSats, Pioneers, SMEX, MIDEX, Probes, and Flagships(Lynx).

X-Ray↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution observations of low contrast phenomena from an advanced geosynchronous platform

Present technology allows radiometric monitoring of the earth, ocean and atmosphere from a geosynchronous platform with good spatial, spectral and temporal resolution. The proposed system could provide a capability for multispectral remote sensing with a 50 m nadir spatial resolution in the visible bands, 250 m in the 4 micron band and 1 km in the 11 micron thermal infrared band. The diffraction limited telescope has a 1 m aperture, a 10 m focal length (with a shorter focal length in the infrared) and linear and area arrays of detectors. The diffraction limited resolution applies to scenes of any brightness but for a dark low contrast scenes, the good signal to noise ratio of the system contribute to the observation capability. The capabilities of the AGP system are assessed for quantitative observations of ocean scenes. Instrument and ground system configuration are presented and projected sensor capabilities are analyzed.

Maxwell, M. S.↗

High resolution observations of low contrast phenomena from an Advanced Geosynchronous Platform (AGP)

Present technology allows radiometric monitoring of the Earth, ocean and atmosphere from a geosynchronous platform with good spatial, spectral and temporal resolution. The proposed system could provide a capability for multispectral remote sensing with a 50 m nadir spatial resolution in the visible bands, 250 m in the 4 micron band and 1 km in the 11 micron thermal infrared band. The diffraction limited telescope has a 1 m aperture, a 10 m focal length (with a shorter focal length in the infrared) and linear and area arrays of detectors. The diffraction limited resolution applies to scenes of any brightness but for a dark low contrast scenes, the good signal to noise ratio of the system contribute to the observation capability. The capabilities of the AGP system are assessed for quantitative observations of ocean scenes. Instrument and ground system configuration are presented and projected sensor capabilities are analyzed.

Maxwell, M. S.↗

High resolution spectroscopy from low altitude satellites

The P 78 1 satellite to be placed in a synchronous polar orbit at an altitude of 550-660 km will carry two identical high resolution spectrometers each consisting of a single (approximately 85 cc) intrinsic germanium IGE detector. The payload also includes a pair of phoswitch scintillators, an array of CdTe detectors and several particle detectors, all of which are mounted on the wheel of the satellite. The intrinsic high purity IGE detectors receive cooling from two Stirling cycle refrigerators and facilitate the assembly of large and complex detector arrays planned for the next generation of high sensitivity instruments such as those planned for the gamma ray observatory. The major subsystems of the spectrometer are discussed as well as its capabilities.

Nakano, G. H.↗

Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept

This paper presents results that take a critical step toward proving 10 ps timing resolution’s feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 μm and 50 μm are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 μm thick LGADs at -30°C with a precision of 14.3 ± 1.5 ps.

Particle tracking detectors↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-cost, high-resolution, single-structure array telescopes for imaging of low-earth-orbit satellites

Telescopes that are designed for the unconventional imaging of near-earth satellites must follow unique design rules. The costs must be reduced substantially over those of the conventional telescope designs, and the design must accommodate a technique to circumvent atmospheric distortion of the image. Apertures of 12 m and more along with altitude-altitude mounts that provide high tracking rates are required. A novel design for such a telescope, optimized for speckle imaging, has been generated. Its mount closely resembles a radar mount, and it does not use the conventional dome. Costs for this design are projected to be considerably lower than those for the conventional designs. Results of a design study are presented with details of the electro-optical and optical designs.

Massie, N. A.↗

LAMOST Time-Domain survey: first results of four K2 plates

From Oct. 2019 to Apr. 2020, LAMOST performed a time-domain (TD) spectroscopic survey of four K2 plates with both low- and medium-resolution observations. The low-resolution spectroscopic survey acquired 282 exposures ( ≈ 46.6 h) over 25 nights, yielding a total of about 767 000 spectra, and the medium-resolution survey took 177 exposures ( ≈ 49.1 h) over 27 nights, collecting about 478 000 spectra. More than 70%/50% of low-resolution/medium-resolution spectra have signal-to-noise ratio higher than 10. We determine stellar parameters (e.g., T eff , log g, [Fe/H]) and radial velocity (RV) with different methods, including LASP, DD-Payne and SLAM. In general, these parameter estimations from different methods show good agreement, and the stellar parameter values are consistent with those of APOGEE. We use the Gaia DR2 RV values to calculate a median RV zero point (RVZP) for each spectrograph exposure by exposure, and the RVZP-corrected RVs agree well with the APOGEE data. The stellar evolutionary and spectroscopic masses are estimated based on the stellar parameters, multi-band magnitudes, distances and extinction values. Finally, we construct a binary catalog including about 2700 candidates by analyzing their light curves, fitting the RV data, calculating the binarity parameters from medium-resolution spectra and cross-matching the spatially resolved binary catalog from Gaia EDR3. In conclusion, the LAMOST TD survey is expected to represent a breakthrough in various scientific topics, such as binary systems, stellar activity, stellar pulsation, etc.

79 ASTRONOMY AND ASTROPHYSICS↗

An efficient low- and moderate-resolution spectrograph for the Hale telescope

A new low-to-moderate resolution spectrograph has been designed and built for the Cassegrain focus of the Hale 5.08-meter telescope. To maximize efficiency, resolution, and wavelength coverage the light is divided into two spectra regions by a dichroic filter behind the entrance slit, after which there are two completely separate spectrographs. The blue spectrograph operates from 3200 A to 5200 A while the red one goes from 5200 A to 10,000 A. The red detector is an 800 x 800 TI CCD while the blue detector is a 320 x 512 RCA CCD or a Shectrograph image pulse-counting system. A Boksenberg IPCS can also be mounted on the blue camera. The overall efficiency of the Cassegrain telescope, spectrographs, and CCD's combined, ranges from 5 percent to 13 percent between 3600 A and 8200 A. The spectrograph is usable from 3200 A to 10,400 A.

Oke, J. B.↗