Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Ion temperature anisotropy in the tokamak scrape-off layer

Understanding tokamak exhaust-power heat loads on divertor plates depends critically on having a realistic model of the scrape-off layer (SOL) plasma. The Braginskii fluid model is often solved to understand the SOL plasma behavior. This model is based on the collisional limit for transport along the magnetic field B → . The ions and electron gyrofrequencies are assumed to be much larger than the Coulomb collision frequencies, which are nonetheless, sufficiently large to yield common parallel and perpendicular temperatures for each species, i.e. the temperatures are assumed to be isotropic. Additionally, in certain circumstances such as encountered for the tokamak H-mode, the ion temperature can be quite anisotropic. In this work, the anisotropy effects are implemented in the two-dimensional (2D) transport code UEDGE. Various geometries (1D slab, 2D slab and a toroidal tokamak geometry) are used to study the 2D structure of ion temperature anisotropy and its effects on plasma transport in detail. Results show that the effects of ion temperature anisotropy on the plasma parallel transport are substantial near the magnetic X-point, which leads to different steady state density profiles in the divertor regions. The extra mirror force introduced by ion temperature anisotropy can be one of the main forces contributing to the plasma flow in the SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotherm Modeling and Techno-Economic Analysis of Contactor Technologies for New Tetraamine-Appended MOF for NGCC Applications

Recently, a family of tetraamine-functionalized metal-organic frameworks (MOF) has been reported as promising sorbent materials for capturing CO2 from flue gas conditions relevant to natural gas combined cycle (NGCC) applications. The main advantages of these materials are their two-step cooperative CO2 adsorption, which gives rise to unusual two step-shaped CO2 adsorption profiles and their high thermal stability. This work presents the modelling of the two-transition isotherm of the tetraamine-appended MOF, N,N'-bis(3-aminopropyl)-1,4-diaminobutane (3-4-3)-appended Mg2(dobpdc), and the techno-economic analysis (TEA) of carbon capture processes utilizing this sorbent. Due to the unusual isotherm shapes of the experimental CO2 adsorption data for tetraamine-appended Mg2(dobpdc) and the strong nonlinearity of CO2 loading with respect to temperature and pressure, we tested two different models which use logistic functions for representing the different isotherm behaviors in the different pressure ranges. The first model uses the quadratic isotherm model in the low-pressure region, the Langmuir isotherm model in the middle pressure range, and the dual site Langmuir isotherm model in the high-pressure range. To model the transition between regions we used the arctangent functions independent of temperature and the thermal effect was accounted by using the Clausius-Clapeyron relation]. The second model is an extension of the weighted dual-site Langmuir isotherm model presented by Hughes et al.. In this extended model, the dual-site Langmuir isotherm is employed in the three transition regions, using temperature-dependent logistic functions to activate or deactivate the isotherm model in the low, middle, and high-pressure ranges. Both models fit the experimental data quite well with root mean squared errors (RMSE’s) of 0.41 and 0.17 for model 1 and model 2, respectively. Since model 2 resulted in a lower RMSE, it was leveraged for the development of the gas/solid contactor models used by the TEA. Specifically, two different contactor models, an axial-flow fixed bed and moving bed contactor, were developed as part of this work. These models are dynamic, pressure-driven, and consist of mass, energy, and momentum conservation equations. A kinetic model was also developed by performing parameter estimation using experimental fixed bed breakthrough data. These models are then used to simulate CO2 capture processes from the flue gas generated from a ~600 gross MW NGCC power plant. A cost model was developed which considers the capital cost of the reactors and the significant operating costs such as steam and electricity. Using NETL’s Framework for the Optimization and Quantification of Uncertainty of Uncertainty and Surrogates tool (FOQUS), which has the capability of linking models built using numerous modelling platforms with derivative-free optimization solvers, a techno-economic optimization of the carbon capture processes was performed which minimizes the cost of capture.

Caballero, Daison↗

Nitrate Removal Across Ecogeomorphic Zones in Wax Lake Delta, Louisiana (USA)

Human activities have increased nitrate export from rivers, degrading coastal water quality. At deltaic river mouths, the flow of water through wetlands increases nitrate removal, and the spatial organization of removal rates influences coastal water quality. To understand the spatial distribution of nitrate removal in a river-dominated delta, in this study we deployed 23 benthic chambers across ecogeomorphic zones with varying elevation, vegetation, and sediment properties in Wax Lake Delta (Louisiana, USA) in June 2018. Regression analyses indicate that normalized difference vegetation index is a useful predictor of summertime nitrate removal. Mass transfer velocity were approximately three times greater on a vegetated submerged levee (13 mm hr –1 ), where normalized difference vegetation index was greatest, compared to other locations (4.6 mm hr –1 ). Two methods were developed to upscale nitrate removal across the delta. The flooded-delta method integrates spatially explicit potential removal rates across submerged portions of the delta and suggests that intermediate elevations on the delta—including submerged levees—are responsible for 70% of potential nitrate removal despite covering only 33% of the flooded area. The channel network method treats the delta as a network of river channels and suggests that although secondary channels are more efficient than primary channels at removing received nitrate, primary channels collectively contribute more to overall removal because they convey more of the total nitrate load. The two upscaling methods predict similar rates of nitrate removal, equivalent to less than 4% of nitrate entering the delta. To protect coastal waters against high nitrate loads, management policies should aim to reduce upstream nutrient loads.

54 ENVIRONMENTAL SCIENCES↗

Operation and performance of VRF systems: Mining a large-scale dataset

The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period April 2023 – September 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This fourth semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY23. As a part of the RCCS design task, recent efforts have been made to complete a conceptual design of the RCCS for the HC-HTGR, including the design update of the water panel and system configuration favorable in point of view of fabrication and system operation. Design calculations were conducted under various heat load conditions to validate the system design. Transient simulations using RELAP5-3D were conducted to investigate system dynamics under transients of interest and to evaluate the system performance in the design condition. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat sink. In the primary system thermal hydraulics task, the preliminary analysis was performed for a long term pressurized conduction cooldown (PCC) transient. This analysis used a combination of a fully resolved and coarse homogenized mesh to predict the temperature distribution for the steady-state initial condition and the PCC transient. The steady-state initial condition was determined using a fully resolved full core model with 3D solid to 1D fluid coupling. The fully resolved mesh was also used to model the first 20 seconds of the PCC. The temperature difference between fuel pins and the graphite matrix becomes minimal and the dominant heat transfer shifts to a larger scale radially towards the RCCS. After 20 seconds, a homogenized coarse mesh is used, greatly reducing the computational costs of the model. These results demonstrate that the core is designed to passively remove enough decay heat in a protected loss of primary coolant flow to prevent an unsafe rise of core temperatures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PANDEMIC: Occupancy driven predictive ventilation control to minimize energy consumption and infection risk

During the SARS-CoV-2 (COVID-19) pandemic, governments around the world have formulated policies requiring ventilation systems to operate at a higher outdoor fresh air flow rate for a sufficient time, which has led to a sharp increase in building energy consumption. Therefore, it is necessary to identify an energy-efficient ventilation strategy to reduce the risk of infection. In this study, we developed an occupant-number-based model predictive control (OBMPC) algorithm for building ventilation systems. First, we collected the occupancy and Heating, ventilation, and air conditioning system (HVAC) data from March to July 2021. Then, four different models (Auto regression moving average-based multilayer perceptron (ARMA_MLP), Recurrent neural networks (RNN), Long short-term memory networks (LSTM), and Nonhomogeneous Markov with change points detection (NH_Markov)) were used to predict the number of room occupants from 15 min to 24 h ahead with an interval output. We found that each model could predict the number of occupants with 85% accuracy using a one-person offset. Furthermore, the accuracy of 15 min of the ahead prediction could reach 95% with a one-person offset, but none of them could track abrupt changes. The occupancy prediction results were used to calculate the ventilation demand using the Wells-Riley equation, and the upper bound can maintain an infection risk lower than 2% for 93% of the day. This OBMPC model could reduce the coil load by 52.44% and shift the peak load by 3 h up to 5 kW compared with 24 × 7 h full outdoor air (OA) system when people wear masks in the space. The occupancy prediction uncertainty could cause a 9% to 26% difference in demand ventilation, a 0.3°C to 2.4°C difference in zone temperature, a 28.5% to 44.5% difference in outdoor airflow rate, and a 10.7% to 28.2% difference in coil load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electron Dynamics Within a MITL Containing a Load

In this paper, we derive the vacuum electric fields within specific cylindrically symmetric magnetically insulated transmission lines (MITLs) in the limit of an infinite speed of light for an arbitrary time-dependent current. We focus our attention on two types of MITLs: the radial MITL and a spherically curved MITL. We then simulate the motion of charged particles, such as electrons, present in these MITLs due to the vacuum fields. In general, the motion of charged particles due to the vacuum fields is highly nonlinear since the fields are nonlinear functions of spatial coordinates and depend on an arbitrary time-dependent current drive. Using guiding center theory, however, one can describe the gross particle kinetics using a combination of $\textbf {E} \times \textbf {B}$ and $\nabla B$ drifts. In addition, we compare our approximate inner MITL field models and particle kinetics with those from a fully electromagnetic simulation code. We find that the agreement between the approximate model and the electromagnetic simulations is excellent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Supported-Single Nickel Atom Catalysts for the Methanation of Carbon Dioxide

Synthesis of twenty-seven bimetallic catalysts consisting of nickel and one of nine different dopants (B, Co, Cu, Fe, Mg, Mn, Sn, V, and Zn) supported on three different metal oxides (Al 2 O 3 , CeO 2 , and SiO 2 ) is carried out via organometallic grafting. The catalysts are evaluated for their activity and selectivity for the CO 2 methanation reaction at a feed ratio of H 2 /CO 2 of 4 at 300 °C in a high-throughput flow reactor system. After in situ pre-activation (500 °C in H 2 ), Ni/Co/CeO 2 exhibited high conversion (84.3%) and selectivity for methane (99.6%). Ni/Co/CeO 2 was characterized by high-resolution transmission electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS), X-ray diffraction, H 2 -temperature-programmed reduction (H 2 -TPR), and CO 2 -temperature-programmed desorption (CO 2 -TPD). HRTEM showed the presence of single Ni and Co atoms on ceria after pre-reduction at 500 °C and after the methanation reaction at 300 °C for 15 h. XPS determined that the strong interaction between Ni, Co, and ceria increased after the reduction, leading to a charge transfer between Ni and Ce that created oxygen vacancies in ceria. Nickel was found to be Ni 2+ in the as-prepared material and was partially reduced in the presence of cobalt and after the activation in H 2 at 500 °C. The DFT results show that both nickel and cerium exhibit lower Bader charges in the Ni/Co/CeO 2 system, confirming that the presence of cobalt enhances the reduction of both Ni and Ce through electronic interactions. This indicates that single cationic Ni atoms are highly effective for the methanation reaction. In conclusion, the organometallic grafting technique is found to be efficient for synthesizing catalysts with highly homogeneous dispersed species at low metal loadings (0.16 wt % Ni–0.15 wt % Co), which leads to high turnover frequency (up to 248.7 h –1 ) and durability for methanation.

CO2 conversion↗

Results from a wake-steering experiment at a commercial wind plant: investigating the wind speed dependence of wake-steering performance

Wake steering is a wind farm control strategy in which upstream wind turbines are misaligned with the wind to redirect their wakes away from downstream turbines, thereby increasing the net wind plant power production and reducing fatigue loads generated by wake turbulence. In this paper, we present results from a wake-steering experiment at a commercial wind plant involving two wind turbines spaced 3.7 rotor diameters apart. During the 3-month experiment period, we estimate that wake steering reduced wake losses by 5.6% for the wind direction sector investigated. After applying a long-term correction based on the site wind rose, the reduction in wake losses increases to 9.3%. As a function of wind speed, we find large energy improvements near cut-in wind speed, where wake steering can prevent the downstream wind turbine from shutting down. Yet for wind speeds between 6–8 m/s, we observe little change in performance with wake steering. However, wake steering was found to improve energy production significantly for below-rated wind speeds from 8–12 m/s. By measuring the relationship between yaw misalignment and power production using a nacelle lidar, we attribute much of the improvement in wake-steering performance at higher wind speeds to a significant reduction in the power loss of the upstream turbine as wind speed increases. Additionally, we find higher wind direction variability at lower wind speeds, which contributes to poor performance in the 6–8 m/s wind speed bin because of slow yaw controller dynamics. Further, we compare the measured performance of wake steering to predictions using the FLORIS (FLOw Redirection and Induction in Steady State) wind farm control tool coupled with a wind direction variability model. Although the achieved yaw offsets at the upstream wind turbine fall short of the intended yaw offsets, we find that they are predicted well by the wind direction variability model. When incorporating the expected yaw offsets, estimates of the energy improvement from wake steering using FLORIS closely match the experimental results.

17 WIND ENERGY↗

A cell-centered AMR-ALE framework for 3D multi-material hydrodynamics. Part I: Lagrangian and indirect Euler AMR algorithms

Many applications of physics and engineering involve wide ranges of time and spatial scales. The numerical simulation of localized small scales such as shock waves and material interfaces requires a large number of computational cells in these regions. For these applications, Lagrangian and Arbitrary-Lagrangian-Eulerian (ALE) related methods are engaging since the moving mesh feature naturally brings mesh cells on shock discontinuities and material interfaces are carefully captured. In addition, Adaptive-Mesh-Refinement (AMR) strategies aim to optimize computational resources by concentrating finer mesh cells only in areas of interest while using coarser cells elsewhere. A key but challenging AMR requirement consists in efficiently distributing the computational effort to achieve high accuracy without the prohibitive computational costs associated with uniformly fine grids. Here, in this document, the coupling of the p4est AMR library with a cell-centered Lagrangian scheme is presented with the goal to perform reliable 3D Lagrangian-AMR and indirect Euler-AMR multi-material simulations. In particular, it is shown that starting from a 3D indirect ALE code, the memory management and load balancing requirements can be delegated to an external library (here the p4est library) to unlock ALE-AMR capabilities. First, we present a strategy to transcribe the octant-based connectivity of the 3D AMR framework with that of an unstructured mesh of polygonal cells used in Lagrangian hydrodynamics. Then, we show how refinement and coarsening operations must be adapted to the particular Lagrangian framework to ensure the conservation of volume during those steps. Finally, several numerical test cases are presented that demonstrate the capabilities of the Lagrangian-AMR and indirect Euler-AMR algorithms.

3D cell-centered Lagrangian numerical scheme↗

Scale bridging damage model for quasi-brittle metals informed with crack evolution statistics

Computationally efficient methods for bridging length scales, from highly resolved micro/meso-scale models that can explicitly model crack growth, to macro-scale continuum models that are more suitable for modeling large parts, have been of interest to researchers for decades. In this work, an improved brittle damage model is presented for the simulation of dynamic fracture in continuum scale quasi-brittle metal components. Crack evolution statistics, including the number, length, and orientation of individual cracks, are extracted from high-fidelity, finite discrete element method (FDEM) simulations and used to generate effective material moduli that reflect the material’s damaged state over time. This strategy allows for the retention of small-scale physical behaviors such as crack growth and coalescence in continuum scale hydrodynamic simulations. However, the high-fidelity simulations required to generate the crack statistics are computationally expensive. Thus, steps were taken to produce a flexible constitutive model to reduce the number of costly high-fidelity simulations needed to produce accurate results. A new stress based degradation criterion is introduced for the degradation of individual material zones. This allows for the development of a heterogeneous damage distribution within the bulk material. Then a flow stress model is added to the hydrodynamic simulation to account for plasticity in quasi-brittle materials. As a result, the effective moduli model can be applied to a larger range of materials. The effective moduli constitutive model is used to simulate beryllium flyer plate experiments. The results from the continuum scale simulations using statistics from a single high-fidelity simulation are found to be in excellent agreement with numerical and experimental velocity interferometer data. The same set of crack statistics are used to extrapolate the results of a higher rate flyer plate case using the effective moduli model. In conclusion, the extension of this model to higher rate cases shows promise for further reducing the number of costly high-fidelity simulations needed to generate crack statistics.

36 MATERIALS SCIENCE↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

The Role of Regional Connections in Planning for Future Power System Operations Under Climate Extremes

Identifying the sensitivity of future power systems to climate extremes must consider the concurrent effects of changing climate and evolving power systems. We investigated the sensitivity of a Western U.S. power system to isolated and combined heat and drought when it has low (5%) and moderate (31%) variable renewable energy shares, representing historic and future systems. We used an electricity operational model combined with a model of historically extreme drought (for hydropower and freshwater-reliant thermoelectric generators) over the Western U.S. and a synthetic, regionally extreme heat event in Southern California (for thermoelectric generators and electricity load). We found that the drought has the highest impact on summertime production cost (+10% to +12%), while temperature-based deratings have minimal effect (at most +1%). The Southern California heat wave scenario impacting load increases summertime regional net imports to Southern California by 10-14%, while the drought decreases them by 6-12%. Combined heat and drought conditions have a moderate effect on imports to Southern California (-2%) in the historic system and a stronger effect (+8%) in the future system. Southern California dependence on other regions decreases in the summertime with the moderate increase in variable renewable energy (-34% imports), but hourly peak regional imports are maintained under those infrastructure changes. By combining synthetic and historically driven conditions to test two infrastructures, we consolidate the importance of considering compounded heat wave and drought in planning studies and suggest that region-to-region energy transfers during peak periods are key to optimal operations under climate extremes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Optimization of Advanced Energy Plants with Integrated Thermal, Mechanical, and Electro-Chemical Storage (Final Report)

The increasing use of renewable energy sources is leading to increased cycling of fossil-fueled power plants (FFPP) that are designed to operate at base-loaded conditions. Integrating energy storage facilities with the FFPPs can be helpful in reducing load-following operation of FFPPs. Decentralized deployment of energy storage facilities at the FFPP level has considerable advantages due to possibilities of smaller storage capacities, immediate benefits realized by the host power plant due to the increase in the efficiency, cleaner emission and higher plant life to name a few. Most importantly, deployment at the FFPP level can exploit the existing equipment items and facilities at the host power plant, thus reducing the CAPEX and reducing the storage capacity. However, realization of these benefits will critically depend on novel configuration/integration strategies with the least impact on the power plant operation and its configuration. Furthermore, dynamics of the entire integrated system including both the FFPP and the storage technologies must be taken into account to obtain the cost-optimal solution. With these motivations, the objective of this project was to complete a focused evaluation of decentralized deployments of energy storage facilities at the FFPP level. Promising thermal, chemical, mechanical, and electro-chemical storage technologies were evaluated with due consideration of their transient response to obtain various optimal system concepts that can minimize the levelized cost of storage. For thermal storage, cryogenic energy storage along with high temperature heat storage in molten salt as well as phase change material were evaluated. For mechanical storage, cryogenic air storage and pumped hydro storages were evaluated. For chemical storage, hydrogen storage was evaluated. For electrochemical storage, the team evaluated sodium sulfur, vanadium redox flow battery as well as Li-ion batteries. Integration of these storage technologies with the natural gas combined cycle (NGCC) and supercritical pulverized coal (SCPC) plants was considered. Six technologies, namely molten salt, cryogenics, compressed air, pumped hydro, H2 storage and Li-ion battery storage, were downselected based on their levelized cost of storage. It was observed that the ranking of the optimal storage technology can differ based on the host power plant technology even when same demand/supply/price profile for electricity are considered. It was also observed that as the variability in power demand varies, the ranking of the optimal storage technologies vary. However, for the same demand and LMP profile, top six optimal storage technologies for NGCC vs SCPC plants did not differ much even though LCOS for the same technology and optimal size of a given storage technology did differ. Detailed techno-economic assessment of these six technologies was undertaken.

01 COAL, LIGNITE, AND PEAT↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lignin molecular weights of Populus trichocarpa residues after CELF pretreatment

Here we present a dataset of molecular weights of lignin from a woody energy crop (Populus trichocarpa) residues after a series of co-solvent enhanced lignocellulosic fractionation (CELF) pretreatment. The natural poplar variant GW-9947 from the Center for Bioenergy Innovation (CBI) was used. The poplar was knife milled and passed through a 1 mm sieve and CELF pretreatment was performed in a Parr autoclave reactor with 7.5 wt % solids loading, 0.5 wt% H2SO4 as catalyst at 150°C with various time. Tetrahydrofuran was added in a 1:1 mass ratio with water as the pretreatment solvent. Lignin was isolated from the pretreated samples after ball-milling in a porcelain jar with ceramic balls via Retsch PM 200 at 580 rpm for 2.5 h followed by enzymatic hydrolysis in acetate buffer (pH 4.8, 50 °C) for 48 h. The solid residue was isolated by centrifugation and hydrolyzed again with freshly added buffer and enzymes for another 48 h. After filtration, the solid residue was extracted twice with 96% (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover lignin. The lignin samples were then derivatized in an acetic anhydride/pyridine (1:1, v/v) mixture and stirred at room temperature for 24 h. Ethanol was added to the reaction mixture, left for 30 min and then removed with a rotary evaporator. The addition and removal of ethanol was repeated at least 3 times until all traces of acetic acid were removed. Acetylated lignin samples were then dissolved in tetrahydrofuran (THF) at a concentration of 1.0 mg/mL. The molecular weight of acetylated lignin was measured by a gel permeation chromatography (GPC) on a PSS-Polymer Standards Service (Warwick, RI, USA) GPC SECurity 1200 system featuring Agilent HPLC 1200 components equipped with four Waters Styragel columns (HR1, HR2, HR4 and HR6) and an UV detector (270 nm). Tetrahydrofuran was used as the mobile phase and flow rate was 0.3 mL/min. The Polymer Standards Service WinGPC Unity software (Build 6807) was used for data processing for all the samples. The data provides information about the effects of CELF pretreatment time at 150 ºC on lignin molecular weights.

09 BIOMASS FUELS↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗