Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Power allocation by load aggregator with heterogeneous loads using weighted projection

With the recently increasing adoption of transactive energy markets, the role of a load aggregator is becoming increasingly important. Among the many tasks of an aggregator, the task of managing the electricity consumption among a group of grid-interactive efficient buildings according to the demand on the grid is taken up. Specifically, here, the task of allocating a certain amount of power among the participating customers while respecting their preferences and comfort is considered. Modeling this as an aggregate flexibility, the virtual battery conditions that are employed to verify the feasibility of a candidate power profile are derived. A feasible power profile, when allocated, satisfies specified comfort bands. To determine the ideal power requirement of the loads, the model-free control method is employed. The feasible power profile is allocated by embedding the customers’ preferences through weights, posing the power constraint as a hyperplane, and employing a weighted projection from the ideal power requirements onto the constraint plane to solve the considered task. The proposed method is computationally efficient and scalable to any number of heterogeneous thermostatically controlled loads in buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing plasma face component thermal response to rotating 3D magnetic fields for SPARC tokamak

Thermal response simulations of plasma-facing components (PFCs) in the SPARC tokamak, performed with the HEAT code, show that three-dimensional (3D) heat loads resulting from stationary n=1 perturbations require highly radiative scenarios, with up to 95% of the power crossing the separatrix (P SOL ) being radiated, to maintain PFC temperatures within acceptable operational limits, whereas the application of slowly rotating 3D fields substantially reduces the thermal loads. The HEAT module, developed to predict heat loads from non-axisymmetric plasmas, is extended to model time-dependent heat flux patterns generated by rotating 3D fields, and a comprehensive thermal analysis is performed on PFCs subjected to both the maximum and minimum power loads, as well as to rotating heat flux distributions, to evaluate the temperature evolution for varying perturbation amplitudes and rotation frequencies. The extension of this analysis to 3D fields with toroidal mode number n=2 shows that this configuration leads to weaker localized heat flux peaks relative to the n=1 case, enabling safe operation with less than 80% of the power radiated when static 3D fields of low amplitude are applied, while using slowly rotating fields at higher amplitudes. These results indicate that n=2 perturbations are generally less detrimental to divertor power exhaust, emphasizing the strong dependence of divertor power exhaust on the characteristics of the applied 3D fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wind Turbine Main Bearing Rating Lives as Determined by IEC 61400-1 and ISO 281

This presentation studies the rating lives of wind turbine main bearings, as determined by the IEC 61400-1 and ISO 281 standards. A brief review of relevant bearing life theory and turbine design requirements is provided. This includes a discussion on possible shortcomings, including the existence (or not) of the bearing fatigue load limit and the validity of assuming linear damage accumulation. A detailed study is then undertaken to determine rating lives for two models of main bearing in a 1.5 MW wind turbine. Rating life assessment is carried out under different conditions, including various combinations of main bearing temperature, wind field characteristics, lubricant viscosity and contamination levels. Rating lives are found to be sufficiently above the desired 20 year design life for both bearing models under expected operating conditions. For the larger bearing, operational loads are shown to be below or close to the bearing fatigue load limit a vast majority of the time. Key sensitivities for rating life values are shown to be the temperature and contamination. Overall, the results of this study suggest that rating life assessment does not account for reported rates of main bearing failures in 1 to 3 MW wind turbines. In future work, it is recommended that efforts be undertaken to identify principal root causes of main bearing failures, possibly leading to a new application standard specific to this component. It is also recommended that impacts of partial wake impingement on main bearing rating lives are investigated.

ENGINEERING,WIND ENERGY↗

Broadband Characterization and Circuit Model Development of Transmission-Scale Transformers

This report describes broadband measurements of transmission-scale transformers typical in the electric power grid. This work was performed as part of the EMP Resilient Grid LDRD project at Sandia National Laboratories to generate circuit models that can be used for high-altitude electromagnetic pulse (HEMP) coupling simulations and response predictions. The objective of the work was to obtain characterization data of substation yard equipment across a frequency range relevant to HEMP. Vector network analyzer measurements up to 100 MHz were performed on two power transformers at ABB-Hitachi and a single ITEC potential transformer. Custom cable breakouts were designed to interface with the transformer terminals and provide ground connections to the chassis at the base of the transformer bushings. The three-phase terminals of the power transformers were measured as a common mode impedance using a parallel resistive splitter, and the single-phase terminals of the potential transformer were measured directly. A vector fitting algorithm was used to empirically fit circuit models to the resulting two-port networks and input impedances of the measured objects. Simplified circuit representations of the input impedances were also generated to assess the degree of precision needed for high-altitude electromagnetic pulse response predictions, which were performed in Sandia's XYCE circuit simulator platform. HEMP coupling simulations using the transformer models showed significant reduction in the voltage peak and broadening in the pulse width seen at the power transformer compared to the traveling wave voltage. This indicated the importance of the load condition when defining the coupled insult in an electric power substation. Simplified circuit models showed a similar voltage at the transformer with a smoothed waveform. The presence of potential transformers in the simulation did not significantly change the simulated voltage at the power transformer. Single-port input impedance models were also developed to define load conditions when transfer characteristics were not necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Molecular Dynamics Simulation of Pore-Size Effects on Gas Adsorption Kinetics in Zeolites

Strong gas-mineral interactions or slow adsorption kinetics require a molecular-level understanding of both adsorption and diffusion for these interactions to be properly described in transport models. In this combined molecular simulation and experimental study, noble gas adsorption and mobility is investigated in two naturally abundant zeolites whose pores are similar in size (clinoptilolite) and greater than (mordenite) the gas diameters. Simulated adsorption isotherms obtained from grand canonical Monte Carlo simulations indicate that both zeolites can accommodate even the largest gas (Rn). However, gas mobility in clinoptilolite is significantly hindered at pore-limiting window sites, as seen from molecular dynamics simulations in both bulk and slab zeolite models. Further, experimental gas adsorption isotherms for clinoptilolite confirm the presence of a kinetic barrier to Xe uptake, resulting in the unusual property of reverse Kr/Xe selectivity. Finally, a kinetic model is used to fit the simulated gas loading profiles, allowing a comparison of trends in gas diffusivity in the zeolite pores.

74 ATOMIC AND MOLECULAR PHYSICS↗

ATTNChecker: Highly-Optimized Fault Tolerant Attention for Large Language Model Training

Large Language Models (LLMs) have demonstrated remarkable performance in various natural language processing tasks. However, the training of these models is computationally intensive and susceptible to faults, particularly in the attention mechanism, which is a critical component of transformer-based LLMs. In this paper, we investigate the impact of faults on LLM training, focusing on INF, NaN, and near-INF values in the computation results with systematic fault injection experiments. We observe the propagation patterns of these errors, which can trigger non-trainable states in the model and disrupt training, forcing the procedure to load from checkpoints. To mitigate the impact of these faults, we propose ATTNChecker, the first Algorithm-Based Fault Tolerance (ABFT) technique tailored for the attention mechanism in LLMs. ATTNChecker is designed based on fault propagation patterns of LLM and incorporates performance optimization to adapt to both system reliability and model vulnerability while providing lightweight protection for fast LLM training. Evaluations on four LLMs show that ATTNChecker on average incurs on average 7% overhead on training while detecting and correcting all extreme errors. Compared with the state-of-the-art checkpoint/restore approach, ATTNChecker reduces recovery overhead by up to 49×.

Liang, Yuhang [University of Alabama - Birmingham]↗

Enhancing power grid resilience to winter storms via generator winterization with equity considerations

Here we develop two-stage stochastic programming models for generator winterization that enhance power grid resilience while incorporating social equity. The first stage in our models captures the investment decisions for generator winterization, and the second stage captures the operation of a degraded power grid, with the objective of minimizing load shed and social inequity. To incorporate equity into our models, we propose a concept called adverse effect probability that captures the disproportionate effects of power outages on communities with varying vulnerability levels. Grid operations are modeled using DC power flow, and equity is captured through mean or maximum adverse effects experienced by communities. We apply our models to a synthetic Texas power grid, using winter storm scenarios created from the generator outage data from the 2021 Texas winter storm. Our extensive numerical experiments show that more equitable outcomes, in the sense of reducing adverse effects experienced by vulnerable communities during power outages, are achievable with no impact on total load shed through investing in winterization of generators in different locations and capacities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust Solution Approach for Bilevel Demand Response Game at Distribution Level

In this paper, a bilevel electricity pricing and demand response game between a distribution system operator (DSO) and load aggregators (LAs) is considered, and a robust decision model is proposed for the DSO to deal with the uncertainties from the wholesale market prices and demand consumptions of LAs. With the max-min objective at the upper level, the robust bilevel model is converted into a single level model by the Karush-Kuhn-Tucker (KKT) conditions and prime-dual transformation. Several groups of experiments have been conducted based on different preferences on uncertainty gaps and peak load reductions to show its effectiveness. After-the-fact scenario analysis has indicated that the robust solution is more beneficial in reducing the risk of inaccurate predictions as compared to the risk neutral strategy.

Chen, Yang↗

Nuclear microreactor transient and load-following control with deep reinforcement learning

The economic feasibility of nuclear microreactors will depend on minimizing operating costs through advancements in autonomous control, especially when these microreactors are operating alongside other types of energy systems (e.g., renewable energy). This study explores the application of deep reinforcement learning (RL) for real-time drum control in microreactors, exploring performance in regard to load-following scenarios. By leveraging a point kinetics model with thermal and xenon feedback, we first establish a baseline using a single-output RL agent, then compare it against a traditional proportional–integral–derivative (PID) controller. This study demonstrates that RL controllers, including both single- and multi-agent RL (MARL) frameworks, can achieve similar or even superior load-following performance as traditional PID control across a range of load-following scenarios. In short transients, the RL agent was able to reduce the tracking error rate in comparison to PID by one half to one third. Over extended 300-minute load-following scenarios in which xenon feedback becomes a dominant factor, PID maintained better accuracy, but RL still remained within a 1% error margin despite being trained only on short-duration scenarios. This highlights RL’s strong ability to generalize and extrapolate to longer, more complex transients, affording substantial reductions in training costs and reduced overfitting. Furthermore, when control was extended to multiple drums, MARL enabled independent drum control as well as maintained reactor symmetry constraints without sacrificing performance---an objective that standard single-agent RL could not learn. We also found that, as increasing levels of Gaussian noise were added to the power measurements, the RL controllers were able to maintain lower error rates than PID, and to do so with at least 10% and upwards of 150% less control effort. These findings illustrate RL's potential for autonomous nuclear reactor control, laying the groundwork for future integration into high-fidelity simulations and experimental validation efforts.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗

Environmentally Assisted Fatigue in Light Water Reactor Environment

This report summarizes the Environmentally Assisted Fatigue (EAF) research conducted at ANL under the US DOE Light Water Reactor Sustainability (LWRS) program. Starting from a rich background in theoretical and experimental EAF, ANL previously developed an approach to evaluate fatigue performance of reactor materials in light water reactor environments with the correction factor F en . The approach was based on a large body of experimental work performed at ANL and elsewhere, and was consistent with American Society of Mechanical Engineers (ASME)’s methodology governing the design and construction of reactor components. In recent years, the program was focused on component fatigue prediction and made several major and fundamental contributions in this area. These accomplishments help meet the needs identified by the industry concerning component level fatigue predictions in complex, transient conditions. The main contribution of the ANL program involved the development of a system-level model for estimating residual strain and life of nuclear reactor coolant system components under connected-system-thermal-mechanical boundary conditions. The goal was to predict the stress hotspots, strain residuals, strain amplitudes and the resulting fatigue lives. Thermal-mechanical stress analysis was performed considering thermal stratification and a design-basis reactor loading cycle. Based on the finite element (FE) model results, the strain residuals, strain amplitudes and resulting fatigue lives of reactor coolant system (RCS) components were predicted. The results show that some of the RCS components can have significantly different strain amplitudes, residual strain, and fatigue lives, despite having similar geometry and material. In addition, the simulated component-level strain profile can guide the selection of appropriate test inputs for conducting laboratory-scale EAF tests. Building upon the system-level model, ANL developed a digital twin (DT) framework to predict the structural states and associated fatigue life of components in real-time. This framework is a comprehensive system designed to predict the structural states and fatigue lives of reactor components. It includes multiple models and integrates artificial intelligence (AI), machine learning (ML), and FE based modeling tools to evaluate the structural states and fatigue lives.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Short-term nodal load forecasting based on machine learning techniques

This paper introduces an advanced Short-term Nodal Load Forecasting (STNLF) method that forecasts nodal load profiles for the next day in power systems, based on the combined use of three machine learning techniques. Least Absolute Shrinkage and Selection Operator (LASSO) is employed to reduce the number of features for a single nodal load forecasting. Principal Component Analysis (PCA) is used to capture the features of historical loads in low-dimensional space compared to the original high-dimensional load space where features are barely possible to depict. Additionally, Bayesian Ridge Regression (BRR) is utilized to decide the parameters of the prediction model from a statistics perspective. Tests based on modified PJM load data demonstrate the effectiveness of the proposed STNLF method compared to the state-of-the-art General Regression Neural Network (GRNN) method. Moreover, the reliability of the day-ahead Unit Commitment (UC) solution is shown to have been improved, based on the forecasted load data using the proposed STNLF method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Constraining Black Carbon Aging in Global Models to Reflect Timescales for Internal Mixing

The radiative effects of black carbon depend critically on its atmospheric lifetime, which is controlled by the rate at which freshly emitted combustion particles become internally mixed with other aerosol components. Global aerosol models strive to represent this process, but the timescale for aerosol mixing is not easily constrained using observations. In this study, we apply a timescale parameterization derived from particle‐resolved simulations to quantify, in a global aerosol model, the timescale for internal mixing. We show that, while highly variable, the average timescale for internal mixing is approximately 3 hr, which is much shorter than the 24‐hr aging timescale traditionally applied in bulk aerosol models. We then use the mixing timescale to constrain the aging criterion in the Modal Aerosol Module. Our analysis reveals that, to best reflect timescales for internal mixing, modal models should assume that particles transition from the hydrophobic (fresh) to the hydrophilic (aged) class once they accumulate a coating thickness equal to four monolayers of sulfuric acid, as opposed to the model's current aging criterion of eight monolayers. We show that, in remote regions like the Arctic and Antarctic, predictions of black carbon loading and its seasonal variation are particularly sensitive to the model representation of aging. By constraining aging in global models to reflect mixing timescales simulated by the particle‐resolved model, we eliminate one of the free parameters governing black carbon's long‐range transport and spatiotemporal distribution.

54 ENVIRONMENTAL SCIENCES↗

Restoration Strategy for Active Distribution Systems Considering Endogenous Uncertainty in Cold Load Pickup

Cold load pickup (CLPU) phenomenon is identified as the persistent power inrush upon a sudden load pickup after an outage. Under the active distribution system (ADS) paradigm, where distributed energy resources (DERs) are extensively installed, the decreased outage duration can induce a strong interdependence between CLPU pattern and load pickup decisions. In this paper, we propose a novel modelling technique to tractably capture the decision-dependent uncertainty (DDU) inherent in the CLPU process. Subsequently, a two-stage stochastic decision-dependent service restoration (SDDSR) model is constructed, where first stage searches for the optimal switching sequences to decide step-wise network topology, and the second stage optimizes the detailed generation schedule of DERs as well as the energization of switchable loads. Further, to tackle the computational burdens introduced by mixed-integer recourse, the progressive hedging algorithm (PHA) is utilized to decompose the original model into scenario-wise subproblems that can be solved in parallel. The numerical test on modified IEEE 123-node test feeders has verified the efficiency of our proposed SDDSR model and provided fresh insights into the monetary and secure values of DDU quantification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonizing all-electric communities via carbon-responsive control of behind-the-meter resources

The progression of electrification in the building and transportation sectors brings new opportunities for energy decarbonization. With higher dependence on the grid power supply, the variation of the grid carbon emission intensity can be utilized to reduce the carbon emissions from the two sectors. Existing coordinated control methods for buildings with distributed energy resources (DERs) either consider electricity price or renewable energy generation as the input signal, or adopt optimization in the decision-making, which is difficult to implement in the real-world environment. This paper aims to propose and validate an easy-to-deploy rule-based carbon responsive control framework that facilitates coordination between all-electric buildings and electric vehicles (EVs). The signals of the grid carbon emission intensity and the local photovoltaics (PV) generation are used for shifting the controllable loads. Extensive simulations were conducted using a model of an all-electric mixed-use community in a cold climate to validate the control performance with metrics such as emissions, energy consumption, peak demand, and EV end-of-day state-of-charge (SOC). Our study identifies that 4.5% to 27.1% of annual emission reduction can be achieved with limited impact on energy costs, peak demand, and thermal comfort. Additionally, up to 32.7% of EV emission reduction can be obtained if the EV owners reduce the target SOC by less than 21.2%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of thermal treatment on structure and catalytic performance of ceria-zirconia supported copper oxide (CuO x /Ce y Zr 1-y O 2 ) catalysts for CO oxidation

Copper oxide (CuO x ) supported on ceria-zirconia (Ce y Zr 1-y O 2 , y = 1.0, 0.5, 0.0) catalysts were investigated to elucidate the effects of thermal treatment on their physicochemical properties and catalytic performance in carbon monoxide (CO) oxidation. Here, the catalysts were synthesized via a one-pot chemical vapor deposition (OP-CVD) method at 700˚C and 900˚C with controlled Cu loading. Characterization techniques, including synchrotron X-ray diffraction (S-XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), inductively coupled plasma spectroscopy (ICP), and N 2 adsorption-desorption, were implemented to probe the crystalline structure, molecular and electronic structure, oxygen vacancies, specific surface area (SSA) and metal loading. CO oxidation was chosen as a model reaction to explore the structure-catalytic performance relationship. A ∼100% CO conversion was achieved at < 150˚C, particularly with the CuO x /CeO 2 catalyst calcined at 700˚C. In contrast, calcination at 900˚C caused a ∼90% decrease in SSA and a ∼24% increase in T 50 . Activity tests revealed that increasing ZrO 2 content lowered CO oxidation activity despite generating more defect sites. In-situ measurement of the 700 °C calcined samples revealed the presence of stable and unstable defects in CuO x /Ce 0.5 Zr 0.5 O 2 and CeO 2 respectively, which play a key role in the activity of the catalysts. The results highlight that catalytic performance is closely related to the SSA. Furthermore, an optimum calcination temperature favor significant oxygen vacancy formation with required CuO x -support interactions, enhancing redox properties and catalytic performance.

36 MATERIALS SCIENCE↗

Probabilistic impact of electricity tariffs on distribution grids considering adoption of solar and storage technologies

This study models the role of electricity tariffs on the long-term adoption of photovoltaic and storage technologies as well as the consequent impact on the distribution grid. An adoption model that captures the economic rationality of tariff-driven investments and considers the stochastic nature of individual consumers’ decisions is proposed. This model is then combined with a probabilistic load flow to evaluate the long-term impacts of the adoption on the voltage profiles of the distribution grid. To illustrate the methodology, different components of the electricity tariffs, including solar compensation mechanisms and time differentiation of Time-of-Use (ToU) rates, are evaluated, using a case study involving a section of a medium-voltage network with 118 nodes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗