Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid Extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

A new approach to the isolation of milligram amounts of significant geochemical compounds.

The modification of an automatic preparative collection system for gas-liquid chromatography is described that is designed to make the system operational for milligram-scale high-efficiency separations of selected components in a geological sample. The sample in question is an organic extract from the Green River Formation Oil Shale, and the compounds selected are the sterane and triterpane hydrocarbons.

Wszolek, P. C.↗

Thiophenes as Indicators of Aqueous Alteration in Carbonaceous Meteorites

A common class of organic compound in low petrographic type meteorites is the sulfur-containing thiophenes. The presence of this compound class in organic-rich meteorites which have experienced substantial levels of aqueous alteration is relatively unexplored. Early reports of these compounds attributed them to artifacts brought about by reactions between elemental sulfur and organic matter during high temperature extraction and analysis steps. Subsequent investigations confirmed their indigeneity, yet their environment of formation remained unconstrained. Here we present data which suggests that thiophenes are parent body alteration products that reflect the role of liquid water on asteroids in the early solar system.

Sephton, Mark A.↗

Extraterrestrial Amino Acids in the Almahata Sitta Meteorite

Amino acid analysis of a meteorite fragment of asteroid 2008 TC3 called Almahata Sitta was carried out using reverse-phase liquid chromatography coupled with UV fluorescence detection and time-of-flight mass spectrometry (LC-FD/ToF-MS) as part of a sample analysis consortium. LC-FD/ToF-MS analyses of hot-water extracts from the meteorite revealed a complex distribution of two- to seven-carbon aliphatic amino acids and one- to three-carbon amines with abundances ranging from 0.5 to 149 parts-per-billion (ppb). The enantiomeric ratios of the amino acids alanine, R-amino-n-butyric acid (beta-ABA), 2-amino-2-methylbutanoic acid (isovaline), and 2-aminopentanoic acid (norvaline) in the meteorite were racemic (D/L approximately 1), indicating that these amino acids are indigenous to the meteorite and not terrestrial contaminants. Several other non-protein amino acids were also identified in the meteorite above background levels including alpha-aminoisobutyric acid (alpha-AIB), 4-amino-2- methylbutanoic acid, 4-amino-3-methylbutanoic acid, and 3-, 4-, and 5-aminopentanoic acid. The total abundances of isovaline and alpha-AIB in Almahata Sitta are 1000 times lower than the abundances of these amino acids found in the CM carbonaceous chondrite Murchison. The extremely low abundances and unusual distribution of five carbon amino acids in Almahata Sitta compared to Cl, CM, and CR carbonaceous chondrites may reflect extensive thermal alteration of amino acids on the parent asteroid by partial melting during formation or subsequent impact shock heating. It is also possible that amino acids were synthesized by catalytic reactions on the parent body after asteroid 2008 TC3 cooled to lower temperatures.

Glavin, Daniel P.↗

Initial in Situ Measurements of Perennial Meltwater Storage in the Greenland Firn Aquifer

A perennial storage of water in a firn aquifer was discovered in southeast Greenland in 2011. We present the first in situ measurements of the aquifer, including densities and temperatures. Water was present at depths between approx. 12 and 37m and amounted to 18.7 +/- 0.9 kg in the extracted core. The water filled the firn to capacity at approx. 35m. Measurements show the aquifer temperature remained at the melting point, representing a large heat reservoir within the firn. Using model results of liquid water extent and aquifer surface depth from radar measurements, we extend our in situ measurements to the Greenland ice sheet. The estimated water volume is 140 +/- 20 Gt, representing approx. 0.4mm of sea level rise (SLR). It is unknown if the aquifer temporary buffers SLR or contributes to SLR through drainage and/or ice dynamics.

measurements↗

HD gas purification for polarized HDice targets production at Jefferson Lab

Solid, frozen-spin targets of molecular HD were rst developed for nuclear physics by a collaboration between Syracuse University and Brookhaven National Lab. They have been successfully used in measurements with photon beams, rst at the Laser-Electron-Gamma-Source [1] and most recently at Je erson Lab during the running of the E06-101 (g14) experiment [2]. Preparations are underway to utilize the targets in future electron experiments after the completion of the 12 GeV JLab upgrade [3]. HD is an attractive target since all of the material is polarizable, of low Z, and requires only modest holding elds. At the same time, the small contributions from the target cell can be subtracted from direct measurements. Reaching the frozen-spin state with both high polarization and a signi cant spin relaxation time requires careful control of H2 and D2 impurities. Commercially available HD contains 0.5 - 2% concentrations of H2 and D2. Low-temperature distillation is required to reduce these concentrations to the 104 level to enable useful target production. This distillation is done using a column lled with heli-pack C [4] to give good separation e ciency. Approximately 12 moles of commercial HD is condensed into the mechanically refrigerated system at the base temperature of 11K. The system is then isolated and the temperature stabilized at 18K producing liquid HD, which is boiled by a resistive heater. The circulation established by the boil-o condensing throughout the column then ltering back down produces a steady-state isotopic separation permitting the extraction of HD gas with very low H2 and D2 content. A residual gas analyzer initially monitors distillation. Once the H2 concentration falls below its useful operating range, samples are periodically collected for analysis using gas chromatography [5] and Raman scattering. Where the measurement techniques overlap, good agreement is obtained. The operation of the distillery and results of gas analysis will be discussed. References [1] Phy. Rev. Lett. 101 (2009) 172002. [2] www.jlab.org/exp_prog/proposals/06/PR-06-101.pdf [3] www.jlab.org/exp_prog/proposals/12/PR12-12-009.pdf, www.jlab.org/exp_prog/proposals/12/PR12-12-010.pdf, and www.jlab.org/exp_prog/proposals/11/PR12-11-111.pdf [4] Nucl. Inst. Meth. 664 (2012) 347, www.wilmad-labglass.com/Products/LG-6730-104/ [5] Rev. Sci. Instrum. 82, 024101 (2011).

Whisnant, Charles↗

A New Neural Network Approach Including First-Guess for Retrieval of Atmospheric Water Vapor, Cloud Liquid Water Path, Surface Temperature and Emissivities Over Land From Satellite Microwave Observations

The analysis of microwave observations over land to determine atmospheric and surface parameters is still limited due to the complexity of the inverse problem. Neural network techniques have already proved successful as the basis of efficient retrieval methods for non-linear cases, however, first-guess estimates, which are used in variational methods to avoid problems of solution non-uniqueness or other forms of solution irregularity, have up to now not been used with neural network methods. In this study, a neural network approach is developed that uses a first-guess. Conceptual bridges are established between the neural network and variational methods. The new neural method retrieves the surface skin temperature, the integrated water vapor content, the cloud liquid water path and the microwave surface emissivities between 19 and 85 GHz over land from SSM/I observations. The retrieval, in parallel, of all these quantities improves the results for consistency reasons. A data base to train the neural network is calculated with a radiative transfer model and a a global collection of coincident surface and atmospheric parameters extracted from the National Center for Environmental Prediction reanalysis, from the International Satellite Cloud Climatology Project data and from microwave emissivity atlases previously calculated. The results of the neural network inversion are very encouraging. The r.m.s. error of the surface temperature retrieval over the globe is 1.3 K in clear sky conditions and 1.6 K in cloudy scenes. Water vapor is retrieved with a r.m.s. error of 3.8 kg/sq m in clear conditions and 4.9 kg/sq m in cloudy situations. The r.m.s. error in cloud liquid water path is 0.08 kg/sq m . The surface emissivities are retrieved with an accuracy of better than 0.008 in clear conditions and 0.010 in cloudy conditions. Microwave land surface temperature retrieval presents a very attractive complement to the infrared estimates in cloudy areas: time record of land surface temperature will be produced.

Aires, F.↗

Subcritical-Water Extraction of Organics from Solid Matrices

An apparatus for extracting organic compounds from soils, sands, and other solid matrix materials utilizes water at subcritical temperature and pressure as a solvent. The apparatus, called subcritical water extractor (SCWE), is a prototype of subsystems of future instrumentation systems to be used in searching for organic compounds as signs of past or present life on Mars. An aqueous solution generated by an apparatus like this one can be analyzed by any of a variety of established chromatographic or spectroscopic means to detect the dissolved organic compound( s). The apparatus can be used on Earth: indeed, in proof-of-concept experiments, SCWE was used to extract amino acids from soils of the Atacama Desert (Chile), which was chosen because the dryness and other relevant soil conditions there approximate those on Mars. The design of the apparatus is based partly on the fact that the relative permittivity (also known as the dielectric constant) of liquid water varies with temperature and pressure. At a temperature of 30 C and a pressure of 0.1 MPa, the relative permittivity of water is 79.6, due to the strong dipole-dipole electrostatic interactions between individual molecular dipoles. As the temperature increases, increasing thermal energy causes increasing disorientation of molecular dipoles, with a consequent decrease in relative permittivity. For example, water at a temperature of 325 C and pressure of 20 MPa has a relative permittivity of 17.5, which is similar to the relative permittivities of such nonpolar organic solvents as 1-butanol (17.8). In the operation of this apparatus, the temperature and pressure of water are adjusted so that the water can be used in place of commonly used organic solvents to extract compounds that have dissimilar physical and chemical properties.

Amashukeli, Xenia↗

Production of Oxygen from Lunar Regolith by Molten Oxide Electrolysis

This paper describes the use of the molten oxide electrolysis (MOE) process for the extraction of oxygen for life support and propellant, and silicon and metallic elements for use in fabrication on the Moon. The Moon is rich in mineral resources, but it is almost devoid of chemical reducing agents, therefore, molten oxide electrolysis is ideal for extraction, since the electron is the only practical reducing agent. MOE has several advantages over other extraction methods. First, electrolytic processing offers uncommon versatility in its insensitivity to feedstock composition. Secondly, oxide melts boast the twin key attributes of highest solubilizing capacity for regolith and lowest volatility of any candidate electrolytes. The former is critical in ensuring high productivity since cell current is limited by reactant solubility, while the latter simplifies cell design by obviating the need for a gas-tight reactor to contain evaporation losses as would be the case with a gas or liquid phase fluoride reagent operating at such high temperatures. Alternatively, MOE requires no import of consumable reagents (e.g. fluorine and carbon) as other processes do, and does not rely on interfacing multiple processes to obtain refined products. Electrolytic processing has the advantage of selectivity of reaction in the presence of a multi-component feed. Products from lunar regolith can be extracted in sequence according to the stabilities of their oxides as expressed by the values of the free energy of oxide formation (e.g. chromium, manganese, Fe, Si, Ti, Al, magnesium, and calcium). Previous work has demonstrated the viability of producing Fe and oxygen from oxide mixtures similar in composition to lunar regolith by molten oxide electrolysis (electrowinning), also called magma electrolysis having shown electrolytic extraction of Si from regolith simulant. This paper describes recent advances in demonstrating the MOE process by a joint project with participation by NASA KSC and MSFC, and Ohio State University and MIT. Progress in measuring cell efficiency for oxygen production, development of non reacting electrodes, and cell feeding and withdrawal will be discussed.

Curreri, Peter A.↗

Determining aromatic and aliphatic carboxylic acids in biomass-derived oil samples using 2,4-dinitrophenylhydrazine and liquid chromatography-electrospray injection-mass spectrometry/mass spectrometry

Converting biomass to a useful fuel commonly incorporates the pyrolysis of the biomass feed stock. The base liquid fraction usually contains high concentrations of ketones, aldehydes and carboxylic acids, of which each can cause detrimental issues related to the storage and upgrading process. Knowing the carbonyl species and the concentration of each will provide value information to the pyrolysis researchers, specifically as that community branches into more targeted end-products such as jet fuel or biogenic-derived oxygenate-containing fuel products. The analysis of aldehydes, ketones and small alkyl carboxylic acids using 2,4-dinitrophenylhydrazine (DNPH) derivation method has been well documented and the method is commonly used the analytical community. By using liquid chromatograph coupled to tandem mass spectrometry, biomass sample analysis can be complete with identification of most carbonyl species. The issue of identifying isobaric ketone and aldehyde compounds can be resolved by utilizing differences in retention time or characteristic fragment ions of ketones and aldehydes. One issue which could not resolved using published methods was identifying aromatic or large non-aromatic carboxylic acids from their corresponding hydroxyl aldehyde or ketone analogs. By modifying the current method for determining carbonyls in biomass samples, carboxylic and hydroxyl-carbonyl can be determined. A careful adjustment of the pH during the extraction procedure and extended heating time of the DNPH solution allowed for the successful derivation of aromatic carboxylic acids. Like other dinitrophenylhydrazones, carboxylic acid derivatives also produce a unique secondary ion pattern, which was useful to distinguish these species from the non-acid analogs.

bio-oil↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

Measuring bio-oil upgrade intermediates and corrosive species with polarity-matched analytical approaches

Integrating biofuels with conventional petroleum products requires improvements in processing to increase blendability with existing fuels. This work demonstrates analysis techniques for more hydrophilic bio-oil liquids that give improved quantitative and qualitative description of the total acid content and organic acid profiles. To protect infrastructure from damage and reduce the cost associated with upgrading, accurate determination of acid content and representative chemical compound analysis are central imperatives to assessing both the corrosivity and the progress toward removing oxygen and acidity in processed biomass liquids. Established techniques form an ample basis for bio-liquids evaluation. However, early in the upgrading process, the unique physical phases and varied hydrophilicity of many pyrolysis liquids can render analytical methods originally designed for use in petroleum-derived oils inadequate. In this work, the water solubility of the organic acids present in bio-oils is exploited in a novel extraction and titration technique followed by analysis on the water-based capillary electrophoresis (CE) platform. The modification of ASTM D664, the standard for Total Acid Number (TAN), to include aqueous carrier solvents improves the utility of that approach for quantifying acid content in hydrophilic bio-oils. Termed AMTAN (modified Total Acid Number), this technique offers 1.2% relative standard deviation and dynamic range comparable to the conventional ASTM method. Furthermore, the results of corrosion product evaluations using several different sources of real bio-oil are discussed in the context of the unique AMTAN and CE analytical approaches developed to facilitate those measurements.

09 BIOMASS FUELS↗

Evaluation of light collection from highly scattering media using wavelength-shifting fibers

Opaque scintillators are designed to have a short scattering length such that scintillation photons are probabilistically confined to a small region of space about their origin. The benefit of this feature is that information on the interaction event topology can be recorded with greater fidelity than in traditional highly transparent media with sensors at large distances from the light production region. Opaque scintillator detectors rely on wavelength-shifting fibers to extract the scintillation light; however, the efficiency of light collection has not yet been directly measured in experiment. We measured the efficiency of light collection as a function of the optical parameters of an opaque liquid and the distance from the origin of the light to the fiber. We use the experimental data to validate a Monte Carlo model of light transport and collection and discuss a simple diffusion model that reproduces the results of Monte Carlo simulation with high fidelity. Furthermore, this combination of validated models has the potential for use in predictions of performance in various designs of future opaque scintillator detectors such as LiquidO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the half-life of 79 Se with accelerator mass spectrometry

The accelerator mass spectrometry (AMS) is an effective method for the determination of the half-life of long-lived radionuclides. In this paper, we report a method for measurement of the half-life of 79 Se. The number of 79 Se atoms was determined from measured 79 Se/Se absolute ratios with the AMS system at the China Institute of Atomic Energy and the decay rate of 79 Se was determined by counting the emitted β-rays with a liquid scintillation spectrometer. The major improvements of our measurements include using the high abundance of an 79 Se sample which was cooled for many years to exclude the interference of short-lived nuclides, the extraction of SeO 2 - molecular ions, that results in a suppression of the 79 Br background by as much as about five orders of magnitude. Also, an AMS measurement of the absolute ratio of 79 Se/Se was developed to avoid systematic errors. The results show that 79 Se/Se is (2.35±0.12)×10 -7 in the reference sample and the radioactivity of 79 Se is (1.24±0.05) Bq/g, so the half-life of 79 Se is (2.78±0.18)×10 5 a.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A rapid thioacidolysis method for biomass lignin composition and tricin analysis

Abstract Background Biomass composition varies from plant to plant and greatly affects biomass utilization. Lignin is a heterogeneous phenolic polymer derived mainly from p -coumaryl, coniferyl, and sinapyl alcohols and makes up to 10–25% of lignocellulosic biomass. Recently, tricin, an O -methylated flavone, was identified as a lignin monomer in many grass species. Tricin may function as a nucleation site for lignification and is advocated as a novel target for lignin engineering to reduce lignin content and improve biomass digestibility in grasses. Thioacidolysis is an analytical method that can be adapted to analyze both lignin monomeric composition and tricin content in the lignin polymer. However, the original thioacidolysis procedure is complex, laborious, and time consuming, making it difficult to be adopted for large-scale screening in biomass research. In this study, a modified, rapid higher throughput thioacidolysis method was developed. Results In combination with gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–mass spectrometry (LC–MS), the modified thioacidolysis method can be used to simultaneously characterize the lignin composition and tricin content using 2–5 mg of dry samples. The modified method eliminates the solvent extraction and drastically improves the throughput; 80 samples can be processed in one day per person. Our results indicate that there is no significant difference in the determination of lignin S/G ratio and tricin content between the original and modified methods. Conclusions A modified thioacidolysis protocol was established. The results demonstrate that the modified method can be used for rapid, high-throughput, and reliable lignin composition and tricin content analyses for screening transgenic plants for cell wall modifications or in large-scale genome-wide association studies (GWAS).

09 BIOMASS FUELS↗

Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method’s LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method’s main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Energy Critical Material Waste Minimization Enabled by AM Techniques

This project provides evidence of the successful recycling of solid waste offcuts resulting from conventional manufacturing processes from three relevant alloys to next-generation nuclear reactor developers, providing a potentially upscalable circular process where no critical elements will be lost. Furthermore, iMOF-based adsorbents were successfully designed for CM extraction from aqueous solution, thereby providing a pathway for future upscaling for salvaging dissolved Ni ions. This research has achieved its goal of showing the impact of novel applications of recycling technologies for solid and liquid wastes that can be upscaled for application.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vortex-Shedding Meters For Liquid And Liquid/Gas Flows

Flowmeters without moving parts developed as replacements for conventional turbine flowmeters. No maintenance required so meters installed permanently. In vortex-shedding flowmeter, piezoelectric or other suitable transducer probe senses changes of pressure caused by passage of vortices. Electronic circuitry processes pressure-change signals to extract vortex-passage frequency representing rate of flow.

Howard, Robert H.↗

Thermal Extraction Modeling within HYBRID: Nominal and Extraction Conditions in Advanced Reactor Systems

This document details continuing development of thermal extraction modeling within the HYBRID repository, the modeling repository of the Integrated Energy Systems program at Idaho National Laboratory. The focus of the thermal extraction work is setting up template energy conversion systems for advanced reactor systems. Based on these nominal conditions, the IES team is developing extraction capability maps that present the system thermal-to-electric efficiency of the remaining system and the mass extraction fraction capability of these systems when extracting steam at various pressures to send steam to applications at a lower given pressure. These curves are mapped on what has become termed “whale chart” due to the appearance of the results. Multiple advanced reactor systems are complete, and it is anticipated that all four of the main advanced reactor types: advanced light-water reactors, high temperature gas reactors, liquid metal fast reactors, and molten salt reactors, will be complete by the end of the fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗