Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Direct Power Control of Back to Back Modular Multilevel Converter with Advanced Grid Support Functions for Grid Forming Application

Possibility of using back-to-back modular multilevel converter system with a direct power control architecture has been investigated in this paper. The rectifier side is controlled to be in grid following mode whereas the inverter side is controlled in grid forming mode. Both the sides’ local controllers use Lyapunov energy function based architecture to accomplish the objective of active and reactive power control as well as maintaining a fixed user defined voltage over the dc bus on the rectifier side. Therefore, the proposed direct power control architecture has embedded dc bus control architecture to maintain fixed user defined value of the capacitors. Similar architecture is implemented on the inverter side to accomplish either voltage control during grid forming or power control during grid following. Advanced grid support functionalities based on IEEE-1547-2018 is implemented and utilized to generate the reference values for either the rectifier or the inverter sides. The overall system is modeled based on MATLAB/Simulink and PLECS domain and various important case studies to verify the efficacy of the overall system has been presented.

direct power control (DPC)↗

Vulnerability Assessments for Power-Electronics-Based Smart Grids

Here, in this paper, a novel method is proposed to evaluate the cyber security of the power-electronics-based smart grids (PESG). The proposed method considers the performance and stability of both the individual inverter and the grid. To our knowledge, this is a first attempt to evaluate the performance and stability of PESG due to cyber attacks. We first develop impedance-based modeling and cyber-attack modeling for PESG. Then we propose innovative two security criteria to evaluate the security of PESG, including stability-based and metrics-based. For metrics-based criteria, we propose to use both total harmonic distortion (THD) and space phasor model (SPM) to evaluate the inverter performance. The simulation results with a two-inverter-based power grid verify the validity and accuracy of the proposed security evaluation method. Results have shown that the performance and stability of PESG are significantly affected by cyber attacks, and thus there is indeed a need to further study cyber security issues of PESG.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cost-Effective Wave Energy Harvesting System with Maximum Power Point Tracking Capability

In this paper, we propose a low-cost bidirectional four-switch inverter that transfers three-phase energy between a permanent magnet synchronous generator (PMSG) driven by a wave energy collector and the power grid or a local ac load. To achieve high control performance, the machine-side inverter uses a high-gain observer for rotor position estimation and a Lyapunov-based approach for torque control. For the gridside inverter control, we estimate the filter capacitor voltage with a model reference adaptive system and control the dc-link voltage with a Lyapunov-based energy function. We also track the maximum power point from the sea waves with an integral control law that actively matches the generator impedance with that of the wave collection device. The proposed system supports both grid-following/forming modes. We validate our control design with simulation results on a 3-kW hardware setup.

wave energy, power systems integration, control de↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Artificial Intelligence-Driven Management of Sustainable Energy Resources: Visibility, Operation, and Control

The rapid global transition toward sustainable energy resources (SERs) is reshaping how modern power systems are observed, optimized, and controlled. While SERs have significantly advanced decarbonization, their weather dependence, variability, and inverter-dominated characteristics challenge traditional, centralized, and deterministic grid operation. At the same time, the proliferation of high-resolution data from inverters, smart meters, and sensors offers unprecedented visibility into system dynamics. Yet, it also exceeds the analytical capability of conventional model-based approaches. Artificial intelligence (AI) provides a new foundation for addressing these challenges by bridging physical laws with data-driven learning, enabling accurate state awareness, adaptive operation, and coordinated control across distributed assets. This article examines how AI transforms the management of SER-rich power systems along three critical dimensions: 1) enhancing visibility by inferring behind-the-meter (BTM) activities, assessing SER flexibility, and reconstructing system states from sparse or noisy measurements; 2) improving operation through AI-enhanced SER service provision, volt/var control (VVC), and dynamic operating envelopes (DOE) for efficiency and security; and 3) advancing control by embedding learning-based intelligence into inverter coordination, voltage and frequency regulation, and long-term dispatch. Together, these developments reveal how AI can convert the variability of SERs from an operational challenge into a source of flexibility, resilience, and intelligence, paving the way toward sustainable, adaptive, and self-optimizing power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Framework for Model Validation and Calibration of Microgrid Components Using PMU Data

This paper presents a framework for phasor measurement-based component model validation and calibration islanded microgrids, with emphasis on grid-forming inverters. Real measurements from the Plum Island microgrid facility are used to calibrate the model of a commercial inverter in the open-source phasor-based distribution system simulator GridLAB-D.Limitations of current distribution system simulators in replicating the behavior of commercial inverters are also identified.

microgrid, Synchrophasor data, model validation↗

Performance Index Assessment for the PV Fleet Performance Data Initiative

We report on 250 PV systems throughout the United States, comprising 157 MWdc of system capacity and more than 10,000 monthly performance index (PI) values. Loss factors were isolated including first-year start-up issues, snowfall, soiling and inverter downtime. Inverter availability was found to contribute significant system energy loss during the first six months of operation, with an average of 8% loss occurring during this period, and 2.3% on average thereafter. Other start-up issues beyond inverter downtime, such as partial string outage, contributed additional underperformance in the first year of operation across the fleet. Winter performance was also found to be below summer performance on average, likely due to snowfall. A relationship was found between monthly snowfall accumulation in centimeters and monthly under-performance, indicating a 6%-40% loss in months with measured snowfall, depending on climate. After correcting for availability, snow and startup loss, over 90% of systems were performing within 10% of monthly expectation based on satellite resource data and PVWatts production estimates.

loss factors↗

Impact of Aggregated PV on Subsynchronous Torsional Interaction: Preprint

This paper investigates induced oscillation (specifically subsynchronous torsional interactions) in power systems arising from photovoltaic (PV) power modulation. Time domain simulations of a modified IEEE first-benchmark system are presented and analyzed. In the IEEE benchmark system, a PV generator was added at the same bus where the synchronous generator is connected. The impact of different parameters of the PV inverters volt-volt-ampere reactive (volt-var) curve on SSTI is examined. The most severe impact found arises from the time response of the inverters reactive power change. A second-order time response with natural frequency matching the rotor speed deviation oscillation frequency and low-damping ratio quickly drives the system to an unstable region. Although it is highly unlikely that conditions necessary for distributed energy resource-induced oscillations would occur in the field, with knowledge of this vulnerability in mind, inverters' control parameters can be designed to avoid it.

aggregated↗

Developing a Reduced 240-Bus WECC Dynamic Model for Frequency Response Study of High Renewable Integration

The ongoing changes in the generation resource mix, driven by the rapid adoption of inverter-based resources (IBR) as well as the early retirement of synchronous generators, are bringing new challenges to the planning and operation of bulk electric power systems. Consequently, there is an increasing need to understand, design, and quantify the reliability service provision from IBRs by performing integrated scheduling and dynamic simulations. However, test systems that have consistent scheduling and dynamic models rarely exist largely because of the decoupled nature of the two simulations on a synchronous generator-dominated system. This paper develops the dynamic model of a reduced Western Electricity Coordinating Council (WECC) system. In conjunction with the existing scheduling model, it is suitable for integrating scheduling and dynamic simulations. The reduced 240-bus WECC model reflects the generation resource mix of the Western Interconnection as of 2018. Moreover, the developed dynamic model is validated against field frequency events measured by FNET/GridEye and preserves the dominant inter-area oscillation mode in WECC.

dynamic simulation↗

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Root Cause Analysis of AC Overcurrent in July 2020 San Fernando Disturbance

On July 7 2020, approximately 1,000 MW reduction in solar photovoltaic (PV) output was experienced by the bulk power system in Southern California after a three-phase fault. Disturbance analysis indicates that instantaneous AC current caused inverter tripping. The projection of the root cause of AC overcurrent from the NERC report is that inverter current control is not tight. This letter provides a quantitative analysis on ac overcurrent and addresses the following questions: (i) what type of current controls may lead to ac overcurrent; and (ii) how controller parameters and grid strength influence ac overcurrent. Here, the letter provides frequency-domain analysis and time-domain simulation results of a grid-integrated inverter to illustrate the effect of control parameters and grid strength on ac overcurrent.

14 SOLAR ENERGY↗

GIST (Grid Impedance Scan Tool) [SWR-22-73]

NREL has developed GIST (Grid Impedance Scan Tool) to scan the impedance response of inverter-based resources such as land-based and offshore wind power plants, solar power plants, etc., from their electromagnetic transient simulation models to evaluate their impact on grid stability. GIST can scan impedance response of inverter-based resources from vendor-supplied black-box simulation models without requiring internal proprietary details, enabling detailed stability analysis of power systems with high levels of inverter-based generation.

Shah, Shahil↗

EMT data generation

The integration of inverter-based resources (IBRs) in power systems is accelerating, bringing with it significant benefits such as reduced greenhouse gas emissions, improved grid resilience, and increased energy independence. Despite these advantages, the widespread adoption of IBRs introduces several challenges, including issues related to grid stability, increased operational complexity, and the need for updated regulatory frameworks. To address these challenges, IEEE released Standard 2800 in 2022, which sets forth the necessary interconnection capabilities and performance criteria for IBRs connected to transmission and sub-transmission systems. This standard outlines the performance requirements to ensure the reliable integration of IBRs into the bulk power system. Furthermore, in 2023, the North American Electric Reliability Corporation (NERC) published a reliability guideline for electromagnetic transient (EMT) modeling of BPS-connected IBRs. This guideline provides recommendations for developing EMT model requirements, performing model quality checks, and implementing verification practices specifically for EMT models representing BPS-connected inverter-based resources in reliability studies conducted by transmission planners and planning coordinators. These standards and guidelines have a profound impact on EMT studies for transmission networks, influencing system stability analyses, grid recovery and resynchronization processes, fault ride-through evaluations, protection and coordination strategies, advanced control methodologies, and the inclusion of IBRs in transient models of transmission networks. As a result, the generation of EMT data is crucial for conducting various transient-based studies to understand the impact of IBRs. EMT data generation use cases serve as the basis for scenarios in event detection and identification use cases, providing comprehensive details about EMT data generation for transmission grids with inverter-based resources. These use cases supply sufficient training and validation datasets for subsequent EMT analysis algorithms.

Xia, Qianxue↗

Implementing Admittance Relaying for Microgrid Protection

An earlier study evaluated issues with microgrid protection. This highlighted the difficulties with microgrid protection, which include: 1. lack of fault current from inverter-interfaced generation, 2. varying fault current between grid-connected and islanded modes, 3. potential for normally-meshed operation and 4. unbalanced operation due to single-phase loads. It is worth noting that not all microgrid designs will include all these challenges. For example, microgrids could choose to omit meshed operation. Previous work identified differential protection based on the discrete S-transform for line protection and admittance protection for load protection as possible solutions . However, some severe limitations were identified. This included the potential for blinding of the discrete S-transform protection when fault contribution on either end of the line is similar, and loss of protection selectivity for admittance protection in the case of upstream line-ground faults. This report investigates admittance protection as a solution for line and load protection in greater detail by comparing analytical and simulated results. Section 2 describes the protection schemes analyzed and the behavior of inverter-interfaced microgrids under faults in more detail. Section 3 derives sequence networks for the fault cases considered. Section 4 presents a transient model constructed to validate the impedances calculated from the sequence networks. Section 5 compares the results from the sequence networks and transient model. Last, Section 6 presents the conclusions of this study in terms of the suitability of admittance relaying for protection of inverter-interfaced microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Fleet Performance Data Initiative (March 2020 Methodology Report)

Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.

14 SOLAR ENERGY↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗