At least 1,027 records · Page 57

An investigation of the failure modes in U-10Mo monolithic fuel irradiated to high burnup

Here, this study investigated possible failure mode sequences in U-10Mo monolithic fuel irradiated to very-high-burnup. The U-Mo fuel plate used in this study was characterized using scanning electron microscopy (SEM), wavelength dispersive spectroscopy (WDS), and image analysis techniques to investigate how microstructural features may initiate crack formation and propagation through the microstructure, potentially leading to blistering. Distinctly large fission gas pores (FGPs) were observed to preferentially align 5-15µm away from the U-10Mo/Zr interface, parallel to the Zr diffusion barrier. Preferential growth, alignment, and interconnection of FGP could initiate blistering in the fuel plate by creating a fission gas channel, parallel to the U-Mo/Zr interface. FGP alignment in the fuel phase near the U-Mo/Zr interface is believed to be one of the precursors to crack and Type 2 blister formation in monolithic U-Mo fuels. The chemical maps revealed differences in fission product behavior near the U-Mo/Zr interface such that Nd remains in the fuel matrix at the FGP sites. On the other hand, other fission products like Xe and Cs can get trapped in FGPs by Nd in the fuel phase and/or diffuse toward the Zr diffusion barrier.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mix and match light absorbers

Here, perovskite and organic semiconductors can be combined to make tandem solar cells but, to date, their efficiency has hovered around 20%. Now, researchers demonstrate a 23.6% tandem by reducing interfacial defects to improve the perovskite cell's voltage and developing an ultrathin interconnection layer.

14 SOLAR ENERGY↗

Solution techniques for transient stability-constrained optimal power flow – Part II

Transient stability-constrained optimal power flow is an important emerging problem with power systems pushed to the limits for economic benefits, dense and larger interconnected systems, and reduced inertia due to expected proliferation of renewable energy resources. In this study, two more approaches: single machine equivalent and computational intelligence are presented. Also discussed are various application areas, and future directions in this research area. In conclusion, a comprehensive resource for the available literature, publicly available test systems, and relevant numerical libraries is also provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Open Source Modeling Framework for Interdependent Energy-Transportation-Communication Infrastructure in Smart and Connected Communities

Infrastructure in future smart and connected communities is envisioned as an aggregate of public services, including energy, transportation, and communication systems, all intertwined with each other. The intrinsic interdependency among these systems may exert the underlying influence on both design and operation of the heterogeneous infrastructures. Yet, few prior studies have tapped into the interdependency among these systems in order to quantify their potential impacts during standard operation. In response to this, this paper proposes an open-source, flexible, integrated modeling framework suitable for designing coupled energy, transportation, and communication systems and for assessing the impact of their interdependencies. First, a novel multi-level, multi-layer, multi-agent approach is proposed to enable flexible modeling of the interconnected systems. Then, for the framework's proof of concept, preliminary component and system-level models for different systems are designed and implemented using Modelica, an equation-based object-oriented modeling language. Finally, three case studies of gradually increasing complexity are presented (energy, energy + transportation, and energy + transportation + communication) to evaluate the interdependencies among the three systems. Quantitative analyses show that the deviation of the average velocity on the road can be 10.5% and the deviation of the power drawn from the grid can be 7% with or without considering the transportation and communication system at the peak commute time, indicating the presence of notable interdependencies. The proposed modeling framework also has the potential to be further extended for various modeling purposes and use cases, such as dynamic modeling and optimization, resilience analysis, and integrated decision making in future connected communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The DOE Next-Generation Drivetrain for Wind Turbine Applications: Gearbox, Generator, and Advanced Si/SiC Hybrid Inverter System: Preprint

This paper reports on the design and testing results from the U.S. Department of Energy Next-Generation Wind Turbine Drivetrain Project. The drivetrain design reduces the cost of energy by increasing energy capture through drivetrain efficiency improvements; by reducing operation and maintenance costs through reducing gearbox failures; and by lowering capital costs through weight reduction and a series of mechanical and electronic innovations. The paper provides an overview of the drivetrain gearbox and generator and provides a deeper look into the power converter system. The power converter has a number of innovations including the use of hybrid silicon (Si)/silicon carbide (SiC) isolated baseplate switching modules. Switching energies are compared between SiC and Si PIN diodes. The efficiency improvement by use of the SiC diode in a three-level converter is also described. Finally, a brief discussion covering utility interconnect requirements for turbines is provided with a particular focus on utility events that lead to high transient torque loads on drivetrain mechanical elements.

17 WIND ENERGY↗

Module-OT: A Hardware Security Module for Operational Technology

Increased penetration levels of renewable energy and other types of distributed energy resources (DERs) on the modern electric grid-combined with technological advancements for electric system monitoring and control-introduce new cyberattack vectors and increase the cyberattack surface of energy systems. According to the IEEE Std. 1547-2018, DERs must use Modbus, Distributed Network Protocol 3 (DNP3), or Smart Energy Profile 2.0 (SEP2) as their communication protocol. Previous research identified several vulnerabilities and security breaches in each one of these communication protocols; despite this, existing standards for DERs do not recommend cybersecurity measures. In order to reduce vulnerabilities in power distribution systems, this paper presents a novel open-source hardware security module that improves both information and operational security to better protect data and communications on the distribution grid. The security hardware is called “module for operational technology,” or simply Module-OT, and it has been validated and tested in an emulated distribution system application. Module-OT is integrated within a communication system in the transport layer of the Open Systems Interconnection (OSI) model. It improves system security through encryption, authentication, authorization, certificate management, and user access control. The main advancement of Module-OT is the addition of hardware cryptographic acceleration that improves the overall communication performance in terms of end-to-end latency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Frontier (HPE Cray EX) Exascale Supercomputer at the Oak Ridge Leadership Computing Facility

Frontier is the HPE Cray EX exascale supercomputer deployed and operated by the Oak Ridge Leadership Computing Facility (OLCF) at Oak Ridge National Laboratory (ORNL). Frontier is designed for large-scale modeling, simulation, and AI workloads and is built from HPE Cray EX system architecture with AMD CPUs and AMD Instinct GPU accelerators connected by the HPE Slingshot interconnect. System composition (representative production configuration): Frontier is composed of approximately 74 cabinets with 128 compute nodes per cabinet (~9,400 compute nodes total). Each compute node contains one 64-core AMD EPYC CPU and four AMD Instinct MI250X GPUs. Nodes are connected using HPE Slingshot (Slingshot-200 class) networking with multiple NIC ports per node providing high injection bandwidth. Frontier is connected to the Orion parallel file system (multi-tier Lustre) providing a large, center-wide high-performance storage namespace. Operational context: Frontier entered public prominence as the first system to reach No. 1 on the TOP500 list in May 2022 (HPL benchmark), establishing the first widely recognized exascale-era performance milestone. The system supports DOE Office of Science mission workloads and enables leadership-class computational science and AI for open science users.

AMD EPYC↗

Eastern Renewable Generation Integration Study

The Eastern Interconnection (EI) is one of the largest power systems in the world, and its size and complexity have historically made it difficult to study in high levels of detail in a modeling environment. In order to understand how this system might be impacted by high penetrations (30% of total annual generation) of wind and solar photovoltaic (PV) during steady state operations, the National Renewable Energy Laboratory (NREL) and the U.S. Department of Energy (DOE) conducted the Eastern Renewable Generation Integration Study (ERGIS). This study investigates certain aspects of the reliability and economic efficiency problem faced by power system operators and planners. Specifically, the study models the ability to meet electricity demand at a 5-minute time interval by scheduling resources for known ramping events, while maintaining adequate reserves to meet random variation in supply and demand, and contingency events. To measure the ability to meet these requirements, a unit commitment and economic dispatch (UC&ED) model is employed to simulate power system operations. The economic costs of managing this system are presented using production costs, a traditional UC&ED metric that does not include any consideration of long-term fixed costs. ERGIS simulated one year of power system operations to understand regional and sub-hourly impacts of wind and PV by developing a comprehensive UC&ED model of the EI. In the analysis, it is shown that, under the study assumptions, generation from approximately 400 GW of combined wind and PV capacity can be balanced on the transmission system at a 5-minute level. In order to address the significant computational burdens associated with a model of this detail we apply novel computing techniques to dramatically reduce simulation solve time while simultaneously increasing the resolution and fidelity of the analysis. Our results also indicate that high penetrations of wind and PV (collectively variable generation (VG)), significantly impact the operation of traditional generating resources and cause these resources to be used less frequently and operate across a broader output range because wind and PV have lower operating costs and variable output levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of Chromium Impurity Effects and Degradation in Solid Oxide Fuel Cells: The Roles of Reactive Transport and Thermodynamics

The principal objectives of this project were to understand the combined role of transport and thermodynamics in chromium poisoning of solid oxide fuel cell (SOFC) cathodes. Specifically, the differences in the chromium poisoning phenomena in predominantly electronic conducting cathodes such as strontium-doped lanthanum manganite (LSM) and mixed conducting cathodes such as strontium-doped lanthanum ferrite (LSF) and lanthanum nickelate (LNO) have been experimentally elucidated. The voltage-current density curves obtained from single cells featuring these cathode materials in the presence of chromium impurity have been analyzed using a suitable electrochemical model. The results clearly show the higher chromium tolerance of LSF and LNO cathodes compared to LSM cathodes. Further, dense protective coatings of copper-manganese spinel oxide applied via electrophoretic deposition (EPD) conformally on ferritic stainless steel current collectors that simulate the interconnection in SOFC stacks have been applied to SOFCs featuring LSM cathodes. Operation over a period of ten days of SOFCs featuring bare and spinel–coated ferritic stainless steel mesh current collectors show that the coatings are highly effectiveto protect against chromium poisoning.

03 NATURAL GAS↗

Grid Ready, Flexible Large Power Transformer

GE Research and its partner Prolec GE have proposed a novel and breakthrough concept to improve the flexibility and interchangeability of large power transformers (LPTs). LPTs refer in this report to transformers with a power rating equal or greater than 100 MVA. The concept consists of a 3-phase autotransformer bank having one specified high voltage side (HV) voltage and three configurable low voltage side (LV) voltage taps. Moreover, the leakage impedance is adjustable offline using taps which allows to accommodate short-circuit requirements for a wide range of LPTs applications. The research performed aimed to develop and validate a cost-effective design of a flexible LPT and to demonstrate its competitiveness with the LPT fleet currently in operation in the U.S. The concept is intended for the long-term replacement of existing LPTs. In this project, the U.S based population of LPTs was analyzed to determine their commonality in power, voltage classes, and impedance range. Up to 9,700 units, currently deployed in the NERC’s Eastern and Western interconnection regions, were evaluated. This analysis yielded the specifications of two flexible LPTs to be designed to demonstrate the manufacturability and competitiveness of the concept: a 345 kV, 230 MVA and a 230 kV, 100 MVA LPTs. The two LPTs are both configurable to 161 kV, 138 kV, and 115 kV on the LV side and allow leakage impedance variation between 4% and 14%. The design output showed that the flexible LPT is manufacturable and competitive with conventional LPT. The proposed design has a power efficiency of 99.5% and a total active part weight increase ranging only between 15% and 28% relative to conventional LPTs it can be substituted with. Indeed, for the flexible LPT, the higher the LV side voltage is, the higher is its power rating. Hence, flexible LPTs are more competitive when compared with the largest conventional LPT they can replace. Power systems analyses were carried out to evaluate the performance of the flexible LPT when replacing an existing conventional LPT. These analyses showed that short-circuit and inrush currents will remain respectively within 15% and 9.4% of their original levels suggesting that no substations equipment is likely to be replaced due the installation of the flexible LPT. In addition, the analyses showed that the transient overvoltage anticipated at the impedance configuration switch will be manageable and will not pose any particular risk during lightning or switching events. This research proved that the deployment of flexible LPTs in the U.S power grid can greatly improve the grid reliability and its resiliency especially in the event of the loss of multiple LPTs. Moreover, the concept can significantly help reduce LPTs’ spare inventory by providing a high spare coverage level. The performed analysis showed that the designed 345 kV flexible LPT can serve as a spare for up to 34 units currently in operation in the U.S while the designed 230 kV flexible LPT can replace up to 101 units. Flexible LPTs offer new opportunities to U.S utilities to improve interchangeability of LPTs in the transmission system and to better strategize the upcoming renewal of about 70% of the population of LPTs anticipated to retire within the next two decades.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clause-by-Clause Summary of Requirements in IEEE Standard 1547-2018

The revised IEEE 1547 standard (IEEE Std 1547-2018) contains eleven chapters (clauses) and eight annexes that comprise 136 pages. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of distributed energy resources to the electric power system. Implementation of the requirements needs a careful study of the underlying technical concept and also needs the appropriate information that may be required to calculate various settings and configurations. This document aims to provide an introductory text to assist users of IEEE Std 1547-2018 in identifying the following questions: what is the primary audience of the clause/subclause? What knowledge is required to understand the technical subject matter? What information is required to apply/implement the requirements specified? What level of fluency with the subject matter is required to apply/implement the requirements?

24 POWER TRANSMISSION AND DISTRIBUTION↗

Minnesota Solar Pathways: Illuminating Pathways to 10% Solar (Final Technical Report)

The Minnesota Solar Pathways project, funded in part by the Department of Energy’s Solar Energy Technologies Office, was a three-year project designed to explore least-risk, best-value strategies for meeting the State of Minnesota’s solar goals. As part of this aim, the Pathways Team modeled renewable generation costs, examined ways to streamline interconnection, and evaluated technologies that can increase solar hosting capacity on the distribution grid. Midway through the project period, the Pathways Team expanded the scope of study using the same modeling framework from the Minnesota Solar Potential Analysis to estimate and compare generation costs for high renewables penetration scenarios across the Midcontinent Independent System Operator (MISO) region. The analysis concludes that it can be cheaper to overbuild solar + wind and curtail surplus than to store all generation. In addition, the analysis of individual MISO subregions compared with the whole region highlights the opportunities of enabling market potential compared with impact of ongoing transmission constraints. Beyond the analysis of future scenarios, the partnerships initiated and supported through this project underscored the ongoing need for work with stakeholders to address key issues, particularly around siting, and leverage symbiotic strategies to meet state goals.

14 SOLAR ENERGY↗

Key Considerations for Adoption of Technical Codes and Standards for Battery Energy Storage Systems in Thailand

Battery storage is “technology that enables power system operators and utilities to store energy for later use. A battery energy storage system (BESS) is an electrochemical device that charges (or collects energy) from the grid or a power plant and then discharges that energy at a later time to provide electricity or other grid services when needed”. As countries in Asia consider the inclusion of BESS in their power systems to meet policy objectives, renewable energy goals, increase resilience, and expand energy access, there is an opportunity to learn from the experiences of other regions and jurisdictions that have developed more advanced storage markets and deployment methodologies. This report presents global best practices of codes, standards, and interconnection procedures developed to support the safe and reliable deployment of BESS. Several relevant case studies highlight current efforts to ensure safe operation of BESS and showcase potential pathways for adoption of relevant codes and standards. Specifically, this report is intended to support the Thailand Office of Energy Regulatory Commission (OERC) and other stakeholders in their efforts to develop technical codes and standards to govern the installation and operation of BESS; it may also be utilized as a guide for other countries as interest in the deployment of BESS technologies continues to grow.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ribbons Affect Movement of Cracked Solar Cells [Poster]

Cracking of crystalline silicon photovoltaic cells remains a challenging topic in accurately assessing the long-term reliability and performance of affected modules. Cells can be damaged in every stage throughout the lifetime of a photovoltaic module, ranging from manufacturing, transportation, and installation to operation. Initially, the metallization can be able to bridge the gap of fractured cells and keep individual cell fragments electrically connected. However, photovoltaic modules and cells experience thermo-mechanical stresses during operation from temperature changes and pressure cycles of wind and snow loads. This causes the cell fragments to move, which, in turn, can lead to the wear out of the metallization and, consequently, to power loss or a safety hazard. The rate at which this degradation mechanism proceeds is currently unknown. Hence, in this work, we quantify the cell fragment movement of polycrystalline and monocrystalline mini-modules. By using digital image correlation, we were able to extract the normal crack opening and tangential sliding distances of adjacent cell fragments during heating of the mini-modules. Those distances are essential to develop wear-out models for the metallization and determine the rate of the degradation mechanism. We found that the interconnect technology has a significant impact on the direction and quantity of the cell fragment movements.

14 SOLAR ENERGY↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2025 Large Load Literature Review

This literature review catalogs more than 90 publications focused on large loads, and groups the documents and resources thematically into 12 categories, (listed below). The 2026 Large Load Literature Review and Data Sources summary reports are available here: https://emp.lbl.gov/publications/2026-large-load-literature-review -Load forecasting -Data sources -Reliability and resource adequacy -Large load interconnection -Demand flexibility -Generation -Co-location -Data center location/infrastructure -Large load tariffs -Policy options -Maps and tools -Design and operations

97 MATHEMATICS AND COMPUTING↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗