Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Dosimetric characterization of the GammaClip™{sup 169}Yb low dose rate permanent implant brachytherapy source for the treatment of nonsmall cell lung cancer postwedge resection

Purpose: A novel {sup 169}Yb low dose rate permanent implant brachytherapy source, the GammaClip™, was developed by Source Production and Equipment Co. (New Orleans, LA) which is designed similar to a surgical staple while delivering therapeutic radiation. In this report, the brachytherapy source was characterized in terms of “Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTRO” by Perez-Calatayud et al. [Med. Phys. 39, 2904–2929 (2012)] using the updated AAPM Task Group Report No. 43 formalism.Methods: Monte Carlo calculations were performed using Monte Carlo N-Particle 5, version 1.6 in water and air, the in-air photon spectrum filtered to remove photon energies below 10 keV in accordance with TG-43U1 recommendations and previously reviewed {sup 169}Yb energy cutoff levels [D. C. Medich, M. A. Tries, and J. M. Munro, “Monte Carlo characterization of an Ytterbium-169 high dose rate brachytherapy source with analysis of statistical uncertainty,” Med. Phys. 33, 163–172 (2006)]. TG-43U1 dosimetric data, including S{sub K}, D-dot (r,θ), Λ, g{sub L}(r), F(r, θ), φ{sub an}(r), and φ{sub an} were calculated along with their statistical uncertainties. Since the source is not axially symmetric, an additional set of calculations were performed to assess the resulting axial anisotropy.Results: The brachytherapy source's dose rate constant was calculated to be (1.22 ± 0.03) cGy h{sup −1} U{sup −1}. The uncertainty in the dose to water calculations, D-dot (r,θ), was determined to be 2.5%, dominated by the uncertainties in the cross sections. The anisotropy constant, φ{sub an}, was calculated to be 0.960 ± 0.011 and was obtained by integrating the anisotropy factor between 1 and 10 cm using a weighting factor proportional to r{sup −2}. The radial dose function was calculated at distances between 0.5 and 12 cm, with a maximum value of 1.20 at 5.15 ± 0.03 cm. Radial dose values were fit to a fifth order polynomial and dual exponential regression. Since the source is not axially symmetric, angular Monte Carlo calculations were performed at 1 cm which determined that the maximum azimuthal anisotropy was less than 8%.Conclusions: With a higher photon energy, shorter half-life and higher initial dose rate {sup 169}Yb is an interesting alternative to {sup 125}I for the treatment of nonsmall cell lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-396: Dosimetric Accuracy of Proton Therapy for Patients with Metal Implants in CT Scans Using Metal Deletion Technique (MDT) Artifacts Reduction

Purpose: To evaluate the dosimetric accuracy for proton therapy patients with metal implants in CT using metal deletion technique (MDT) artifacts reduction. Methods: Proton dose accuracies under CT metal artifacts were first evaluated using a water phantom with cylindrical inserts of different materials (titanium and steel). Ranges and dose profiles along different beam angles were calculated using treatment planning system (Eclipse version 8.9) on uncorrected CT, MDT CT, and manually-corrected CT, where true Hounsfield units (water) were assigned to the streak artifacts. In patient studies, the treatment plans were developed on manually-corrected CTs, then recalculated on MDT and uncorrected CTs. DVH indices were compared between the dose distributions on all the CTs. Results: For water phantom study with 1/2 inch titanium insert, the proton range differences estimated by MDT CT were with 1% for all beam angles, while the range error can be up to 2.6% for uncorrected CT. For the study with 1 inch stainless steel insert, the maximum range error calculated by MDT CT was 1.09% among all the beam angles compared with maximum range error with 4.7% for uncorrected CT. The dose profiles calculated on MDT CTs for both titanium and steel inserts showed very good agreements with the ones calculated on manually-corrected CTs, while large dose discrepancies calculated using uncorrected CTs were observed in the distal end region of the proton beam. The patient study showed similar dose distribution and DVHs for organs near the metal artifacts recalculated on MDT CT compared with the ones calculated on manually-corrected CT, while the differences between uncorrected and corrected CTs were much pronounced. Conclusion: In proton therapy, large dose error could occur due to metal artifact. The MDT CT can be used for proton dose calculation to achieve similar dose accuracy as the current clinical practice using manual correction.

60 APPLIED LIFE SCIENCES↗

SU-E-T-602: Beryllium Seeds Implant for Photo-Neutron Yield Using External Beam Therapy

Purpose: To evaluate the Neutron yield obtained during prostate external beam irradiation. Methods: Neutrons, that are commonly a radiation safety concern for photon beams with energy above 10 MV, are induced inside a PTV from Beryllium implemented seeds. A high megavoltage photon beam delivered to a prostate will yield neutrons via the reaction Be-9(γ,n)2?. Beryllium was chosen for its low gamma,n reaction cross-section threshold (1.67 MeV) to be combined with a high feasible 25 MV photon beam. This beam spectra has a most probable photon energy of 2.5 to 3.0 MeV and an average photon energy of about 5.8 MeV. For this feasibility study we simulated a Beryllium-made common seed dimension (0.1 cm diameter and 0.5 cm height) without taking into account encapsulation. We created a 0.5 cm grid loading pattern excluding the Urethra, using Variseed (Varian inc.) A total of 156 seeds were exported to a 4cm diameter prostate sphere, created in Fluka, a particle transport Monte Carlo Code. Two opposed 25 MV beams were simulated. The evaluation of the neutron dose was done by adjusting the simulated photon dose to a common prostate delivery (e.g. 7560 cGy in 42 fractions) and finding the corresponding neutron dose yield from the simulation. A variance reduction technique was conducted for the neutrons yield and transported. Results: An effective dose of 3.65 cGy due to neutrons was found in the prostate volume. The dose to central areas of the prostate was found to be about 10 cGy. Conclusion: The neutron dose yielded does not justify a clinical implant of Beryllium seeds. Nevertheless, one should investigate the Neutron dose obtained when a larger Beryllium loading is combined with commercially available 40 MeV Linacs.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-41: A Method for Performing An In-House Batch Assay of I-125 Seeds Used for Prostate Implants

Purpose: The purpose of this work is to evaluate a method for confirming source strength of I-125 seeds in a bulk assay while maintaining sterility and time efficiency. Methods: The I-125 seeds used in this study (STM 1251, Bard Brachytherapy, Inc.) were available as loose seeds or linked in 3, 4, or 5 seed configurations. A third party 10% assay (NIST traceable) is provided. Source strengths ranging from 0.395 to 0.504 U were available for this study. A stand was built out of aluminum to hold an exposure meter (Inovision (Fluke) 451P) at 25 cm above the I-125 sources to measure the exposure rate. Three different seed configurations were measured: loose, linked, and loaded needles (Bard FastFil Seed Implant Needle). The measurements were made in an operating room, and a sterile sheet was used under the non-sterile aluminum stand. Seeds and needles were placed in a sterile tray. Results: One hundred forty-two loose seeds in 5 batches (0.395, 0.395, 0.409, 0.444, 0.444 U/seed) and 902 seeds in 7 batches containing various strands (0.444, 0.444,.0444, 0.466, 0.466, 0.504, 0.504 U/seed) were measured. The average exposure rate per unit activity was measured to be 0.593 mR per hr per U with a standard deviation of 0.016. The Result for loaded needles was 0.261 mR per hr per U with a standard deviation of 0.014. Once the apparatus is set up, measurements of 180 linked sources as supplied in the Bard package requires only a few minutes. Conclusion: The proposed method can confirm the activity of a batch of loose or stranded I-125 seeds within a range of 5%.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-43: Prediction of Dose Increments by Brain Metastases Resection Cavity Shrinkage Model with I-125 and Cs-131 LDR Seed Implantations

Purpose: This work aims to determine dose variability via a brain metastases resection cavity shrinkage model (RC-SM) with I-125 or Cs-131 LDR seed implantations. Methods: The RC-SM was developed to represent sequential volume changes of 95 consecutive brain metastases patients. All patients underwent serial surveillance MR and change in cavity volume was recorded for each patient. For the initial resection cavity, a prolate-ellipsoid cavity model was suggested and applied volume shrinkage rates to correspond to 1.7, 3.6, 5.9, 11.7, and 20.5 months after craniotomy. Extra-ring structure (6mm) was added on a surface of the resection volume and the same shrinkage rates were applied. Total 31 LDR seeds were evenly distributed on the surface of the resection cavity. The Amersham 6711 I-125 seed model (Oncura, Arlington Heights, IL) and the Model Cs-1 Rev2 Cs-131 seed model (IsoRay, Richland, WA) were used for TG-43U1 dose calculation and in-house-programed 3D-volumetric dose calculation system was used for resection cavity rigid model (RC-RM) and the RC-SM dose calculation. Results: The initial resection cavity volume shrunk to 25±6%, 35±6.8%, 42±7.7%, 47±9.5%, and 60±11.6%, with respect to sequential MR images post craniotomy, and the shrinkage rate (SR) was calculated as SR=56.41Xexp(−0.2024Xt)+33.99 and R-square value was 0.98. The normal brain dose as assessed via the dose to the ring structure with the RC-SM showed 29.34% and 27.95% higher than the RC-RM, I-125 and Cs-131, respectively. The dose differences between I-125 and Cs-131 seeds within the same models, I-125 cases were 9.17% and 10.35% higher than Cs-131 cases, the RC-RM and the RC-SM, respectively. Conclusion: A realistic RC-SM should be considered during LDR brain seed implementation and post-implement planning to prevent potential overdose. The RC-SM calculation shows that Cs-131 is more advantageous in sparing normal brain as the resection cavity volume changes with the LDR seeds implementation.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-01: A Simulation Study to Investigate Maximum Allowable Deformations of Implant Geometry Before Plan Objectives Are Violated in Prostate HDR Brachytherapy

Purpose: In prostate HDR brachytherapy dose distributions are highly sensitive to changes in prostate volume and catheter displacements. We investigate the maximum deformations in implant geometry before planning objectives are violated. Methods: A typical prostate Ir-192 HDR brachytherapy reference plan was calculated on the Oncentra planning system, which used CT images from a tissue equivalent prostate phantom (CIRS Model 053S) embedded inside a pelvis wax phantom. The prostate was deformed and catheters were displaced in simulations using a code written in MATLAB. For each deformation dose distributions were calculated, based on TG43 methods, using the MATLAB code. The calculations were validated through comparison with Oncentra calculations for the reference plan, and agreed within 0.12%SD and 0.3%SD for dose and volume, respectively. Isotropic prostate volume deformations of up to +34% to −27% relative to its original volume, and longitudinal catheter displacements of 7.5 mm in superior and inferior directions were simulated. Planning objectives were based on American Brachytherapy Society guidelines for prostate and urethra volumes. A plan violated the planning objectives when less than 90% of the prostate volume received the prescribed dose or higher (V{sub 100}), or the urethral volume receiving 125% of prescribed dose or higher was more than 1 cc (U{sub 125}). Lastly, the dose homogeneity index (DHI=1-V{sub 150}/V{sub 100}) was evaluated; a plan was considered sub-optimal when the DHI fell below 0.62. Results and Conclusion: Planning objectives were violated when the prostate expanded by 10.7±0.5% or contracted by 11.0±0.2%; objectives were also violated when catheters were displaced by 4.15±0.15 mm and 3.70±0.15 mm in the superior and inferior directions, respectively. The DHI changes did not affect the plan optimality, except in the case of prostate compression. In general, catheter displacements have a significantly larger impact on plan optimality than prostate volume changes.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Brachytherapy 03: Identifying the impact of seroma visualization on permanent breast seed implant brachytherapy

Purpose: Uncertainties in target identification can reduce treatment accuracy in permanent breast seed implant (PBSI) brachytherapy. This study evaluates the relationship between seroma visualization and seed placement accuracy. Methods: Spatially co-registered CT and 3D ultrasound (US) images were acquired for 10 patients receiving PBSI. Seromas were retrospectively contoured independently by 3 radiation oncologists on both CT and US and respective consensus volumes were defined, CTV{sub CT} and CTV{sub US}. The seroma clarity and inter-user conformity index (CI), as well as inter-modality CI, volume, and positional differences were evaluated. Correlations with seed placement accuracy were then assessed. CTVs were expanded by 1.25cm to create PTV{sub CT} and PTV{sub US} and evaluate the conformity with PTV{sub Clinical} (CTV{sub Clinical}+1.25cm) used in treatment planning. The change in PTV coincidence by expanding PTV{sub Clinical} by 0.25cm was determined. Results: CTV{sub US} were a mean 68 ± 12% smaller than CTV{sub CT} and generally had improved clarity and inter-user conformity. No correlations between seed displacement and CTV{sub US}-CTV{sub CT} positional difference or CI were observed. Greater seed displacements were associated with larger CTV{sub US}-CTV{sub CT} volume differences (r=−0.65) and inter-user CT CI (r=−0.74). A median (range) 88% (71–99%) of PTV{sub CT} and 83% (69–100%) of PTV{sub US} were contained within PTV{sub Clinical}. Expanding treatment margins to 1.5cm increased coincidence to 98% (86–100%) and 94% (82–100%), respectively. Conclusions: Differences in seroma visualization impacts seed displacement in PBSI. Reducing dependence on CT by incorporating 3DUS into target identification, or expanding CT-based treatment margins to 1.5cm may reduce or mitigate uncertainties related to seroma visualization.

60 APPLIED LIFE SCIENCES↗

Growth and electrical properties of the (Si/Ge)-on-insulator structures formed by ion implantation and subsequent hydrogen-assisted transfer

Systematic features of endotaxial growth of intermediate germanium layers at the bonding interface in the silicon-on-insulator structure consisting of buried SiO{sub 2} layer implanted with Ge{sup +} ions are studied in relation to the annealing temperature. On the basis of the results for high-resolution electron microscopy and thermodynamic analysis of the Si/Ge/SiO{sub 2} system it is assumed that the endotaxial growth of the Ge layer occurs via formation of a melt due to enhanced segregation and accumulation of Ge at the Si/SiO{sub 2} interface. Effect of germanium at the bonding interface on the Hall mobility of holes in silicon layers with nanometer-scale thickness is studied. It is found that the structures including the top silicon layer with the thickness 3-20 nm and incorporating germanium feature the hole mobility that exceeds by a factor of 2-3 the hole mobility in corresponding Ge-free silicon-on-insulator structures.

36 MATERIALS SCIENCE↗

The influence of a doping profile on the characteristics of an ion-implanted GaAs field-effect transistor with a Schottky barrier

A GaAs field-effect ion-implanted transistor with a Schottky barrier is simulated. The doping profile obtained when doping through an insulator mask is determined and the dependences of the static transistor characteristics on the parameters of the doping profile are calculated and analyzed. The physical processes controlling the transistor characteristics in the case of a variation in the parameters of its doping profile and the coefficient of compensation of the substrate are studied. Based on calculations, the optimal doping-profile parameters ensuring the best characteristics for transistors are predicted.

36 MATERIALS SCIENCE↗

Ion implantation of erbium into polycrystalline cadmium telluride

The specific features of the ion implantation of polycrystalline cadmium telluride with grains 20–1000 μm in dimensions are studied. The choice of erbium is motivated by the possibility of using rare-earth elements as luminescent “probes” in studies of the defect and impurity composition of materials and modification of the composition by various technological treatments. From the microphotoluminescence data, it is found that, with decreasing crystal-grain dimensions, the degree of radiation stability of the material is increased. Microphotoluminescence topography of the samples shows the efficiency of the rare-earth probe in detecting regions with higher impurity and defect concentrations, including regions of intergrain boundaries.

36 MATERIALS SCIENCE↗

Specific features of the current–voltage characteristics of SiO{sub 2}/4H-SiC MIS structures with phosphorus implanted into silicon carbide

The effect of phosphorus implantation into a 4H-SiC epitaxial layer immediately before the thermal growth of a gate insulator in an atmosphere of dry oxygen on the reliability of the gate insulator is studied. It is found that, together with passivating surface states, the introduction of phosphorus ions leads to insignificant weakening of the dielectric breakdown field and to a decrease in the height of the energy barrier between silicon carbide and the insulator, which is due to the presence of phosphorus atoms at the 4H-SiC/SiO{sub 2} interface and in the bulk of silicon dioxide.

36 MATERIALS SCIENCE↗

Semi-insulating 4H-SiC layers formed by the implantation of high-energy (53 MeV) argon ions into n-type epitaxial films

It is shown that 9-μm-thick semi-insulating surface layers can be formed in moderately doped n-type silicon carbide (donor concentration 2 × 10{sup 16} cm{sup –3}) via the comparatively low-dose (7 × 10{sup 11} cm{sup –2}) implantation of high-energy (53 MeV) argon ions. The free-carrier removal rate is estimated at ~10{sup 4} cm{sup –1}. The resistivity of the semi-insulator is no less than 7 × 10{sup 12} Ω cm. Analysis of the monopolar current of electron injection into the semi-insulator shows that the impurity-conductivity compensation is due to radiation induced defects pinning the equilibrium Fermi level at a depth of 1.16 eV below the conduction-band bottom. The density of defect states at the Fermi level is 2.7 × 10{sup 16} cm{sup 2} eV{sup –1}.

36 MATERIALS SCIENCE↗

Effect of H{sup +} implantation on the optical properties of semi-insulating GaAs crystals in the IR spectral region

The optical properties of semi-insulating GaAs crystals subjected to multienergy hydrogen-ion implantation and treatment in a high-frequency electromagnetic field are studied in the infrared spectral region. It is established that such combined treatment provides a means for substantially increasing the transmittance of GaAs crystals to values characteristic of crystals of high optical quality. On the basis of analysis of the infrared transmittance and reflectance data, Raman spectroscopy data, and atomic-force microscopy data on the surface morphology of the crystals, a physical model is proposed to interpret the effects experimentally observed in the crystals. The model takes into account the interaction of radiation defects with the initial structural defects in the crystals as well as the effect of compensation of defect centers by hydrogen during high-frequency treatment.

36 MATERIALS SCIENCE↗

Study of the distribution profile of iron ions implanted into silicon

Iron ions with energies of 90 and 250 keV and a dose of 10{sup 16} cm{sup –2} are implanted into a silicon single crystal with the (110) orientation. The method of Rutherford backscattering in combination with channeling is used to study the distribution profiles of the introduced impurity and also the profiles of the distribution of radiation-induced defects in the crystal lattice. Experimental data are compared with the results of simulation performed using the TRIM software package. It is shown that, at an energy of 4.6 keV/nucleon, the average projected ranges coincide; however, at an energy of 1.6 keV/nucleon, the difference amounts to 35%. In addition, it is shown that the calculation incorrectly takes into account the dose dependence at energies of 1.6–4.6 keV/nucleon.

36 MATERIALS SCIENCE↗

In situ Bandgap Determination of the GaAsN Nanolayer Prepared by Low-Energy N{sub 2}{sup +} Ion Implantation

An approach to solving the problem of the in situ bandgap determination in the extremely thin and chemically active nitride nanolayers fabricated in high vacuum on the n-GaAs surface has been suggested. The approach is based on measuring the interband transitions involving the quantum well states by the method of electron energy loss spectroscopy. The bandgap of the nitride layer formed on the GaAs surface by low-energy N{sub 2}{sup +} ion implantation was determined to be 0.2 eV less than that of GaAs, which evidenced for creation of the GaAsN dilute alloy on the GaAs surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffusion and Interaction of In and As Implanted into SiO{sub 2} Films

By means of Rutherford backscattering spectrometry, electron microscopy, and energy-dispersive X-ray spectroscopy, the distribution and interaction of In and As atoms implanted into thermally grown SiO{sub 2} films to concentrations of about 1.5 at % are studied in relation to the temperature of subsequent annealing in nitrogen vapors in the range of T = 800–1100°C. It is found that annealing at T = 800–900°C results in the segregation of As atoms at a depth corresponding to the As{sup +}-ion range and in the formation of As nanoclusters that serve as sinks for In atoms. An increase in the annealing temperature to 1100°C yields the segregation of In atoms at the surface of SiO{sub 2} with the simultaneous enhanced diffusion of As atoms. The corresponding diffusion coefficient is D{sub As} = 3.2 × 10{sup –14} cm{sup 2} s{sup –1}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Do Chemical Effects Affect the Accumulation of Structural Damage during the Implantation of Fluorine Ions into GaN?

The accumulation of structural damage in GaN under irradiation with accelerated F and Ne ions with energies of 1.3 and 3.2 keV/amu is investigated. It is shown that chemical effects during implantation of fluorine ions within the doses under consideration do not noticeably affect the formation of stable structural damage both in the bulk and on the surface of GaN.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase Separation in (Ga,Mn)As Layers Obtained by Ion Implantation and Subsequent Laser Annealing

In this paper, we present the results of studies of the spectral, temperature, and field dependences of the transversal Kerr effect in Ga{sub 1 –} {sub x}Mn{sub x}As (x = 0.0066–0.033) layers produced by ion implantation and subsequent pulsed laser annealing. The complicated nonmonotonous nature of the temperature dependences of the transversal Kerr effect and its dependence on the measurement range indicate a magnetic inhomogeneity of the layers. The reasons for the inhomogeneity can be the Gaussian distribution of Mn over the thickness of the layers and the electron phase separation in them. The appearance of new features in the spectra of the transversal Kerr effect is explained by the presence in the doped semiconductor matrix of nanoregions with a higher carrier concentration and a higher Curie temperature and a shift of the Fermi level into the valence band leading to an increase in the energy of optical transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗