Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

i RadMat: A thermo-mechanical testing system for in situ high-energy X-ray characterization of radioactive specimens

Here, we present an in situ Rad iated Mat erials (iRadMat) experimental module designed to interface with a servo-hydraulic load frame for X-ray measurements at beamline 1-ID at the Advanced Photon Source. This new capability allows in situ studies of radioactive specimens subject to thermo-mechanical loading using a suite of high-energy X-ray scattering and imaging techniques. The iRadMat is a radiation-shielded vacuum heating system with the sample rotation-under-load capability. We describe the design features and performances of the iRadMat and present a dataset from a 300 °C uniaxial tensile test of a neutron-irradiated pure Fe specimen to demonstrate its capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining Confounding Sensitivities In Eddy Current Thin Film Measurements

Determining Confounding Sensitivities In Eddy Current Thin Film Measurements Ethan Gros, Lalita Udpa, Electrical Engineering, Michigan State University, East Lansing MI 48824 James A. Smith, Experiment Analysis, Idaho National Laboratory, Idaho Falls ID 83415 Eddy current (EC) techniques are widely used in industry to measure the thickness of non-conductive films on a metal substrate. This is done using a system whereby a coil carrying a high-frequency alternating current is used to create an alternating magnetic field at the surface of the instrument's probe. When the probe is brought near a conductive surface, the alternating magnetic field will induce ECs in the conductor. The substrate characteristics and the distance of the probe from the substrate (the coating thickness) affect the magnitude of the ECs. The induced currents load the probe coil affecting the terminal impedance of the coil. The measured probe impedance is related to the lift off between coil and conductor as well as conductivity of the test sample. For a known conductivity sample, the probe impedance can be converted into an equivalent film thickness value. The EC measurement can be confounded by a number of measurement parameters. It is the goal of this research to determine which physical properties of the measurement set-up and sample can adversely affect the thickness measurement. The eddy current testing is performed using a commercially available, hand held eddy current probe (ETA3.3H spring loaded eddy probe running at 8 MHz) that comes with a stand to hold the probe. The stand holds the probe and adjusts the probe on the z-axis to help position the probe in the correct area as well as make precise measurements. The signal from the probe is sent to a hand held readout, where the results are recorded directly in terms of liftoff or film thickness. Understanding the effect of certain factors on the measurements of film thickness, will help to evaluate how accurate the ETA3.3H spring loaded eddy probe is at measuring film thickness under varying experimental conditions. This research will study the effects of a number of factors such as i) calibration, ii) conductivity, iii) edge effect, iv) surface finish of base material and v) cable condition and compare with the long term reproducibility of a standard measurement. This work was performed with support from the Department of Energy under the United States National Nuclear Security Administration (NNSA) at the Idaho National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (<10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from a diamond placed edge-on to the x-ray beam. Because of the high peak power density of the x-ray beams, this diamond experiences high temperatures and has to be clamped to a water-cooled heat spreader using thermal interface materials (TIMs), which play a key role in reducing the temperature of the diamond. To evaluate temperature changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This study presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

43 PARTICLE ACCELERATORS↗

Development of a hybrid molecular beam epitaxy deposition system for in situ surface x-ray studies

A portable metalorganic gas delivery system designed and constructed to interface with an existing molecular beam epitaxy chamber at beamline 33-ID-E of the Advanced Photon Source is described. This system offers the ability to perform in situ X-ray measurements of complex oxide growth via hybrid molecular beam epitaxy. The performance of the hybrid molecular beam epitaxy system while delivering metalorganic source materials is described. In conclusion, the high-energy X-ray scattering capabilities of the hybrid molecular beam epitaxy system are demonstrated both on oxide films grown solely from the metalorganic source and ABO 3 oxide perovskites containing elements from both the metalorganic source and a traditional effusion cell.

36 MATERIALS SCIENCE↗

Demonstration of a chamber for strain mapping of steel specimens under mechanical load in a hydrogen environment by synchrotron radiation

Here, we demonstrate a hydrogen gas chamber suitable for lattice strain measurements and capturing radiographs of a steel specimen under a mechanical load using high energy synchrotron x-rays. The chamber is suitable for static and cyclic mechanical loading. Experiments were conducted at the 1-ID-E end station of the Advanced Photon Source, Argonne National Laboratory. Diffraction patterns show a high signal-to-noise ratio suitable for lattice strain measurements for the specimen and with minimal scattering and overlap from the gas chamber manufactured from aluminum. In situ radiographs of a specimen in the hydrogen chamber show the ability to track a growing crack and to map the lattice strain around the crack with high spatial and strain resolution.

47 OTHER INSTRUMENTATION↗

Portable Vibro-acoustic Testing System for In Situ Microstructure Characterization and Metrology

Portable Vibro-acoustic Testing System for In situ Microstructure Characterization and Metrology James A. Smith, Corrie I. Nichol Idaho National Laboratory, Idaho Falls ID Mostafa Fatemi, Mayo Clinic, Rochester MN There is a need in research reactors like the INL to inspect irradiated materials and structures. The goal of this work is to develop a portable scanning infrastructure for a material characterization technique called vibro-acoustography (VA) that has been developed by INL [1] for nuclear applications to characterize fuel, cladding materials, and structures. The proposed VA technology is based on ultrasound and acoustic waves; however, it provides information beyond what is available from the traditional ultrasound techniques and can expand the knowledge on nuclear material characterization and microstructure evolution. VA is a three-dimensional (3D) imaging modality based on ultrasound-stimulated acoustic emission. VA uses the force caused by the beating of two frequencies to generate an acoustic emission signal. Due to absorption or reflection, the energy density in the object at an acoustic focal point changes to produce a “radiation force.” This force locally vibrates the object, which results in an acoustic field that depends on the characteristics of the object at that point. This acoustic field is detected for every point in the object; the resulting data is used to make an image of the object’s mechanical properties. This technology is fundamentally different from traditional ultrasound imaging. More specifically, VA is: (a) based on the “radiation force,” a nonlinear phenomenon in sound propagation, and (b) sensitive to both high and low frequency dynamic responses of the object. The combination of these two response types provides information about characteristics of the object beyond what is possible by traditional ultrasound imaging. High spatial resolution is achieved, since the radiation force is localized to the focal point of the ultrasound beam. Low-frequency information, which is a representative of structural characteristics, is gained through the radiation force mechanism at a low (beat) frequency. This paper will report on the development of a portable scanning that can be set up to characterize materials and component in open water reactors and canals in situ. We will show some initial laboratory results of images generated by vibro-acoustics of surrogate fuel plates and graphite structures and discus the design of the portable system. 1. Smith, J. A., and Kunerth, D. C., “Vibro-acoustic Sensors for Materials Characterization and Related Methods and Systems,” Patent Application 13226280, 09/06/2011.

36 MATERIALS SCIENCE↗

Temperature Sensitivity Study of Eddy Current and Digital Gauge Probes for Nuclear Fuel Rod Oxide Measurement

Temperature Sensitivity Study of Eddy Current and Digital Gauge Probes for Nuclear Fuel Rod Oxide Measurement Faith R. Beck, Department of Mechanical Engineering, Penn State University, State College, PA R. Paul Lind and James A. Smith, Idaho National Laboratory, Idaho Falls, ID Novel fuels are part of the nationwide effort to reduce the enrichment of Uranium for energy production. Performance of such fuels is determined by irradiating their surfaces. To test irradiated samples, the machinery must operate remotely. The plate checker used in this experiment at Idaho National Lab (INL) performs non-destructive testing on fuel rod and plate geometries with two different types of sensors: eddy current and digital thickness gauges. The sensors measure oxide growth and total sample thickness on research fuels, respectively. Sensor measurement accuracy is crucial because even 10 microns of error is significant when determining the viability of an experimental fuel. One parameter known to affect the eddy current and thickness gauge sensors is temperature. Since both sensor accuracies depend on the ambient temperature of the system, the plate checker has been characterized for these sensitivities. The eddy current probes were tested previously in a non-radioactive environment and are noted to have sensitivity to temperature. The manufacturer of the digital gauge probes has noted a rather large coefficient of thermal expansion for their linear scale. It should also be noted that the accuracy of the digital gauge probes are specified at 20°C, which is approximately 7°C cooler than the average hot-cell temperature. In this work, the effect of temperature on the eddy current and digital gauge probes is studied, and thickness measurements are given as empirical functions of temperature. Acknowledgement: This work was supported by the INL and the DOE office of NNSA (National Nuclear Safety Administration).

36 MATERIALS SCIENCE↗

Further Investigation of Surface Velocity Measurements for Material Characterization in Laser Shockwave Experiments

Further investigation of surface velocity measurements for material characterization in laser shockwave experiments James A. Smith, Jeffrey M. Lacy, Clark L. Scott, Bradley C. Benefiel Idaho National Laboratory, Idaho Falls ID Daniel Levesque, Jean-Pierre Monchalin and Martin Lord, National Research Council Canada, Boucherville, QC, Canada ---As part of the US High Performance Research Reactor program, a laser shockwave system is being developed by the Idaho National Laboratory (INL) to characterize interface strength in innovative plate fuel for research reactors around the world. The INL has been working with National Research Council Canada (NRC) on this project for the last five years. One of the concerns is the difficulty of calibrating and standardizing the laser shock technique. The generation of a stress wave by the laser impinging on the plate surface is dependent on the surface preparation, temporal and spatial power distribution of the laser spot, and material properties of the plate. Thus the resulting back surface velocity used to measure the time-varying stress field within the plate is difficult to reproduce across different measurement systems. ---A recent analytical study and testing support the use of the Hugoniot Elastic Limit (HEL) in materials as a robust and simple benchmark to compare stresses generated by different laser shock systems [1]. Using a non-contact laser velocimeter based on a solid Fabry-Perot etalon, the systems at NRC and INL showed that the velocity reached at the HEL is consistent, independent of the laser power used. In this work, the laser velocimeter of the NRC system is tested against a fast rotating wheel to verify accuracy and determine best operating conditions. A round robin test between the two laser shock systems on plates of different Al alloys is presented that shows the correct classification of the Al alloys based on the HEL as well as determining the bias between the systems. Also the effects of some setup parameters on other characteristics of the surface velocity and corresponding stress wave are discussed. 1. J.A. Smith, J.M. Lacy, D. Levesque, J.-P. Monchalin and M. Lord, "Use of the Hugoniot elastic limit in laser shockwave experiments to relate velocity measurements, 42nd Annual Review of Progress in Quantitative Nondestructive Evaluation, AIP Conf. Proc. 1706, pp. 080005-1-080005-10, 2016.

36 MATERIALS SCIENCE↗

Equation of state for 304L stainless steel

Here, a new equation of state for 304L stainless steel has been constructed and entered in the Los Alamos National Laboratory SESAME database with material ID 4273. The equation of state is based on a multiphase approach. The solid and liquid phases were fitted to available experimental data for thermal expansion, heat capacity, and shock Hugoniot, as well as to data from density functional theory calculations of the cold curve and quantum molecular dynamics of the liquid regime. The electronic thermal contribution over the entire equation of state range is based on Tartarus (Green’s functions) average atom calculations. For this low-carbon stainless steel both the density functional and electronic thermal calculations are comprised of 19 wt% Cr, 10 wt% Ni, and the remainder Fe.

36 MATERIALS SCIENCE↗

Bringing chemical structures to life with augmented reality, machine learning, and quantum chemistry

Visualizing 3D molecular structures is crucial to understanding and predicting their chemical behavior. However, static 2D hand-drawn skeletal structures remain the preferred method of chemical communication. Here, we combine cutting-edge technologies in augmented reality (AR), machine learning, and computational chemistry to develop MolAR, an open-source mobile application for visualizing molecules in AR directly from their hand-drawn chemical structures. Users can also visualize any molecule or protein directly from its name or protein data bank ID and compute chemical properties in real time via quantum chemistry cloud computing. MolAR provides an easily accessible platform for the scientific community to visualize and interact with 3D molecular structures in an immersive and engaging way.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

Here, we extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.

Shi, Xianbo [Argonne National Laboratory (ANL), Ar↗

A quantitative imaging framework for lithium morphology: Linking deposition uniformity to cycle stability in lithium metal batteries

Characterizing the morphology of lithium (Li) is crucial for developing long-lasting lithium metal batteries. It is well established that more uniform Li deposition correlates with better cell performance. Li morphology is often characterized through qualitative analysis of scanning electron microscopy (SEM) images; however, there are no widely accepted metrics to quantitatively describe deposition uniformity. Here, we propose a framework to quantify uniformity through SEM image analysis via the index of dispersion (ID) metric, which is defined and presented in the context of Li metal batteries. We also explore experimental impacts of sampling protocols onIDmeasurements. Our results demonstrate that theIDmetric is highly sensitive to variations in deposition uniformity, including the coexistence and uniformity of multiple morphologies, uniformity within a single morphology, and particle size distribution uniformity. Furthermore, it is demonstrated that uniformity, as measured by theID, can be related to the average potential of Li||Li symmetric cells over cycling. Higher capacity cycling leads to more pronounced changes in bothIDand average cell potential. Local minima/maxima are found consistently in bothIDand average cell potential immediately before cells short-circuit, which we suggest may indicate a collapse of the microstructure prior to failure. We put forward this framework as a more robust approach to quantify Li deposition uniformity, advancing the development of Li metal batteries that are safer and longer lasting.

Science & Technology - Other Topics↗

Structure-Function, Stability, and Chemical Modification of the Cyanobacterial Cytochrome b[subscript 6]f Complex from Nostoc sp. PCC 7120

The crystal structure of the cyanobacterial cytochrome b{sub 6}f complex has previously been solved to 3.0-{angstrom} resolution using the thermophilic Mastigocladus laminosus whose genome has not been sequenced. Several unicellular cyanobacteria, whose genomes have been sequenced and are tractable for mutagenesis, do not yield b{sub 6}f complex in an intact dimeric state with significant electron transport activity. The genome of Nostoc sp. PCC 7120 has been sequenced and is closer phylogenetically to M. laminosus than are unicellular cyanobacteria. The amino acid sequences of the large core subunits and four small peripheral subunits of Nostoc are 88 and 80% identical to those in the M. laminosus b{sub 6}f complex. Purified b{sub 6}f complex from Nostoc has a stable dimeric structure, eight subunits with masses similar to those of M. laminosus, and comparable electron transport activity. The crystal structure of the native b{sub 6}f complex, determined to a resolution of 3.0{angstrom} (PDB id: 2ZT9), is almost identical to that of M. laminosus. Two unique aspects of the Nostoc complex are: (i) a dominant conformation of heme b{sub p} that is rotated 180 deg. about the {alpha}- and {gamma}-meso carbon axis relative to the orientation in the M. laminosus complex and (ii) acetylation of the Rieske iron-sulfur protein (PetC) at the N terminus, a post-translational modification unprecedented in cyanobacterial membrane and electron transport proteins, and in polypeptides of cytochrome bc complexes from any source. The high spin electronic character of the unique heme cn is similar to that previously found in the b{sub 6}f complex from other sources.

36 MATERIALS SCIENCE↗

Development and Performance of Superconducting Undulators at the Advanced Photon Source

Several years ago, an article in SRN [1] with the same title as this article summarized the decade-long development of superconducting undulators (SCUs) at the Advanced Photon Source (APS). The article presented those developments leading to the point when the first prototype, called SCU0 and intended for installation at the APS, was under fabrication. SCU0 was built in 2012, its cryogenic performance has been extensively tested, and detailed magnet measurements of the device have been conducted. After verification that SCU0 met all of the technical requirements for APS insertion devices, it was installed in the APS storage ring in January 2013, commissioned in a record short time (two weeks), and became a routinely used source of hard X-rays at the APS Sector 6 ID beamline.

Gluskin, Efim↗

Investigating Powder Spreading Dynamics in Additive Manufacturing Processes by In-situ High-speed X-ray Imaging

The quality of the powder bed is known to be one of the main factors that influence the quality of the part being manufactured by powderbed- based additive manufacturing processes. For example, in the laser powder bed fusion process, it has been demonstrated that improving the powder bed density and homogeneity improves the final quality of the part. Understanding powder spreading dynamics in the powder-bed-based additive manufacturing processes is critical for designing spreading structures and spreading parameters, identifying defect formation mechanisms in the powder bed, and guiding the design of optimized feedstock powders. Extensive efforts have been devoted to understand the fundamental mechanism of the powder flow and spreading process. Various powder flow testers were used to study the flow behavior of powders used in additive manufacturing. However, the powder flow conditions in flow meters are different from those in real additive manufacturing conditions. Models have also been developed to simulate and study the spreading process. The discrete element method (DEM) is currently the main tool for computationally simulating the spreading process. However, these models are based on many physical assumptions. Visible light cameras have been used recently to conduct in-situ study of powder spreading in additive manufacturing. Due to the limited resolution and penetration depth of visible light, it is extremely difficulty to study the particle-scale powder spreading dynamics. Here, to overcome the challenges of studying powder spreading dynamics under real additive manufacturing conditions, we developed an experimental approach to study the particle-scale powder spreading process with high spatial and temporal resolution using the high-speed high-energy X-ray imaging facility at beamline 32-ID-B of the APS. Figure 1 shows an overview of the research setup. It is composed of a vacuum chamber (building environment), an automatic powder spreading system, a laser system, an X-ray source (X-ray outlet), and an X-ray detection/imaging system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-pressure studies of melamine

We performed the first high-pressure study of melamine using X-ray Raman spectroscopy (XRS) up to -17 GPa in a diamond anvil cell at ambient temperature. We utilized the 16 ID-D undulator beamline at the Advanced Photon Source for the X-ray source. The observed diminishment of the 1s {yields} {pi}* peak as well as other changes in the XRS spectra with pressure suggest the possibility of intra- and inter-molecular bonding changes due to two phase changes in the investigated pressure range or hybridization changes of atomic orbitals in the material with pressure. We also performed a complementary X-ray powder diffraction study of neat melamine up to 24 GPa observing at least two phase transitions with pressure. Pressure cycling indicated that the phase transitions were reversible. Density-functional theory calculations performed on the system at ambient and low pressure show a high level of agreement with the experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Durable Airtightness in Single-Family Dwellings - Field Measurementsand Analysis

Here, durability of the building envelope is important to new homes that are increasingly built with improved levels of airtightness. It is also important to weatherized homes such that energy savings from retrofit measures, such as air sealing, are persistent. This paper presents a comparison of air leakage measurements collected in November 2013 through March 2014, with two sets of prior data collected between 2001-2003 from 17 new homes located near Atlanta, GA, and 17 homes near Boise, ID that were weatherized in 2007- 2008. The purpose of the comparison is to determine if there are changes to the airtightness of building envelopes over time. The air leakage increased in all but one of the new homes, with a mean increase of about 25%. The weatherized homes also showed an increase in the mean air leakage (12%). A regression analysis was performed to describe the relationship between prior and current measurements in terms of normalized leakage (NL). The best estimate of the ageing factor predicts a 15% increase in NL over ten years. Further analysis using ResDB data (LBNL’s Residential Diagnostic Database) showed the expected changes in air leakage if ageing were modelled. These results imply the need to examine the causes of increased leakage and methods to avoid them. This increase in leakage with time should be accounted for in long-term population-wide energy savings estimates, such as those used in ratings or energy savings programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

KEPLER ECLIPSING BINARY STARS. I. CATALOG AND PRINCIPAL CHARACTERIZATION OF 1879 ECLIPSING BINARIES IN THE FIRST DATA RELEASE

The Kepler space mission is devoted to finding Earth-size planets orbiting other stars in their habitable zones. Its large, 105 deg{sup 2} field of view features over 156,000 stars that are observed continuously to detect and characterize planet transits. Yet, this high-precision instrument holds great promise for other types of objects as well. Here we present a comprehensive catalog of eclipsing binary stars observed by Kepler in the first 44 days of operation, the data being publicly available through MAST as of 2010 June 15. The catalog contains 1879 unique objects. For each object, we provide its Kepler ID (KID), ephemeris (BJD{sub 0}, P{sub 0}), morphology type, physical parameters (T{sub eff}, log g, E(B - V)), the estimate of third light contamination (crowding), and principal parameters (T{sub 2}/T{sub 1}, q, fillout factor, and sin i for overcontacts, and T{sub 2}/T{sub 1}, (R{sub 1} + R{sub 2})/a, esin {omega}, ecos {omega}, and sin i for detached binaries). We present statistics based on the determined periods and measure the average occurrence rate of eclipsing binaries to be {approx}1.2% across the Kepler field. We further discuss the distribution of binaries as a function of galactic latitude and thoroughly explain the application of artificial intelligence to obtain principal parameters in a matter of seconds for the whole sample. The catalog was envisioned to serve as a bridge between the now public Kepler data and the scientific community interested in eclipsing binary stars.

79 ASTRONOMY AND ASTROPHYSICS↗