Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Homogenization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

The propagation of particulate gravity currents in a V-shaped triangular cross section channel: Lock-release experiments and shallow-water numerical simulations

In this study, we investigate the motion of particulate gravity currents in a horizontal V-shaped channel. The particulate currents consisted of particles whose size varied between 0 and 100 μm but whose mean size increased. Particles were poorly sorted as the variance of the grain size distributions varied between 50 and 200. While the phases of propagation of homogeneous currents in such a geometry have been studied in the literature, this study considers the effects of the grain size on the propagation. The distance of propagation and front velocity of full-depth high-Reynolds-number lock-release experiments and shallow-water equation simulations were analyzed as the mean grain size of the initial particle distributions, defined by mass, was increased from 19 to 58 μm. Similar to the homogeneous currents, three consecutive phases of the front velocity could be identified but their characteristics and extent depend on the particle size. The initial phase, in particular, depends on a dimensionless settling number β that is defined as the ratio of two characteristic time scales, the propagation time x{sub 0}/U, where U is the scale for the front speed and x{sub 0} the lock length, and the settling time h{sub 0}/v{sub s}, where v{sub s} is the scale for the settling velocity and h{sub 0} the initial height of the current. For dimensionless settling numbers less than 0.001, the initial phase is characterized by a constant velocity for over about 6-7 lock lengths that is alike the initial slumping phase of perfectly constant velocity of the homogeneous currents. For dimensionless settling numbers greater than 0.001 and less than 0.015, the initial phase is no longer characterized by a constant velocity but an almost constant velocity for over about a similar 6-7 lock lengths. For dimensionless settling numbers greater than 0.015, however, as such, this phase is no longer seen. This initial phase is followed by a continuous decrease of the front advance, which results from the sedimentation of the particles. Unlike the homogeneous currents, this phase is a non-self-similar propagation. This phase is ended by a viscosity-dominated phase appearing to vary as ∼t{sup 1/7}. The good agreement between the front advance of the experiments and shallow-water equation simulations demonstrates that the mean size by mass is a fairly good proxy of poorly sorted particles.

42 ENGINEERING↗

Design of experiments to spectroscopically characterize radiation flow in stochastic media

Precise characterization of experimental radiation flow is required to validate the high energy density physics models, numerical methods, and codes that are used to simulate radiation-hydrodynamics phenomena such as thermal radiation transport in stochastic media. The Cassio code is used to simulate thermal radiation flow through inhomogeneous, stochastic-media-foam configurations containing optically thick clumps dispersed within an optically thin background aerogel. Cassio can model small inhomogeneous problems directly, but most problems require approximations to meet computer limitations on run-times and memory usage. Various examples of these approximations are methods that produce, in one calculation, an ensemble-averaged solution and associated standard deviation; reduced spatial dimensionality with approximate geometries; and full material homogenization with no geometric detail. Cassio simulations are used to design experiments at the OMEGA-60 Laser Facility that can measure the radiation flow using the spatially resolved COAX absorption spectroscopy diagnostic. The experimental platforms flow radiation through foam targets ranging from a background-only aerogel, to a single configuration of a specified stochastic medium, to a fully homogenized foam of the background and clump materials. Under constant total clump mass, larger clumps (here, larger than 10 μm diameter) will mix more slowly with the background such that the bulk radiation flow is faster than it would be in a fully homogenized material. The COAX platform can be used to infer temperature and density profiles in both the background material and clumps, simultaneously, and therefore to differentiate radiation flow in a range of stochastic and homogeneous media.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heterogeneous Seeding of a Prion Structure by a Generic Amyloid Form of the Fungal Prion-forming Domain HET-s(218-289)

The fungal prion-forming domain HET-s(218–289) forms infectious amyloid fibrils at physiological pH that were shown by solid-state NMR to be assemblies of a two-rung β-solenoid structure. Under acidic conditions, HET-s(218–289) has been shown to form amyloid fibrils that have very low infectivity in vivo, but structural information about these fibrils has been very limited. We show by x-ray fiber diffraction that the HET-s(218–289) fibrils formed under acidic conditions have a stacked β-sheet architecture commonly found in short amyloidogenic peptides and denatured protein aggregates. At physiological pH, stacked β-sheet fibrils nucleate the formation of the infectious β-solenoid prions in a process of heterogeneous seeding, but do so with kinetic profiles distinct from those of spontaneous or homogeneous (seeded with infectious β-solenoid fibrils) fibrillization. Several serial passages of stacked β-sheet-seeded solutions lead to fibrillization kinetics similar to homogeneously seeded solutions. Our results directly show that structural mutation can occur between substantially different amyloid architectures, lending credence to the suggestion that the processes of strain adaptation and crossing species barriers are facilitated by structural mutation.

Wan, William↗

SPECTROSCOPIC ABUNDANCES AND MEMBERSHIP IN THE WOLF 630 MOVING GROUP

The concept of kinematic assemblages evolving from dispersed stellar clusters has remained contentious since Eggen's initial formulation of moving groups in the 1960s. With high-quality parallaxes from the Hipparcos space astrometry mission, distance measurements for thousands of nearby, seemingly isolated stars are currently available. With these distances, a high-resolution spectroscopic abundance analysis can be brought to bear on the alleged members of these moving groups. If a structure is a relic of an open cluster, the members can be expected to be monolithic in age and abundance in as much as homogeneity is observed in young open clusters. In this work, we have examined 34 putative members of the proposed Wolf 630 moving group using high-resolution stellar spectroscopy. The stars of the sample have been chemically tagged to determine abundance homogeneity and confirm the existence of a homogeneous subsample of 19 stars. Fitting the homogeneous subsample with Yale-Yonsei isochrones yields a single evolutionary sequence of {approx}2.7 {+-} 0.5 Gyr. It is concluded that this 19 star subsample of the Wolf 630 moving group sample of 34 stars could represent a dispersed cluster with an ([Fe/H]) = -0.01 {+-} 0.02 and an age of 2.7 {+-} 0.5 Gyr. In addition, chemical abundances of Na and Al in giants are examined for indications of enhancements as observed in field giants of old open clusters; overexcitation/ionization effects are explored in the cooler dwarfs of the sample; and oxygen is derived from the infrared triplet and the forbidden line at {lambda}6300.

74 ATOMIC AND MOLECULAR PHYSICS↗

Incorporation of Ti in epitaxial Fe2TiO4 thin films

The titanomagnetites (Fe2-xTixO4, x = 1) are a family of reducible spinel-structure oxides of interest for their favorable magnetic, catalytic, and electrical transport properties. To understand the stability of the system during low temperature deposition, epitaxial thin films of Fe2TiO4 were deposited by molecular beam epitaxy on MgO(001) at 250 – 375°C. The homogeneous incorporation of Ti, Fe valence, and film morphology were all found to be strongly dependent on the oxidation conditions at the low substrate temperatures employed. More oxidizing conditions led to phase separation into epitaxial, faceted Fe3O4 and rutile TiO2. Less oxidizing conditions resulted in polycrystalline films that exhibited Ti segregation to the film surface, as well as mixed Fe valence (Fe3+, Fe2+, Fe0). A narrow window of intermediate oxygen partial pressure during deposition yielded nearly homogeneous Ti incorporation and a large fraction of Fe2+. However, these films were poorly crystallized, and no occupation of tetrahedral sites in the spinel lattice by Fe2+ was detected by x-ray magnetic circular dichroism at the Fe L-edge. After vacuum annealing, a small fraction of Fe2+ was found to occupy tetrahedral sites. Comparison of these results with previous work suggests that the restriction of the deposition conditions to low temperature by the MgO substrate limits the incorporation of Ti into the spinel lattice. This work suggests a path towards obtaining stoichiometric, well-crystallized Fe2TiO4 by MBE by utilizing high substrate temperature and low oxygen partial pressure during deposition on temperature-stable substrates.

Kaspar, Tiffany C.↗

A large scale coherent magnetic field: interactions with free streaming particles and limits from the CMB

We study a homogeneous and nearly-isotropic Universe permeated by a homogeneous magnetic field. Together with an isotropic fluid, the homogeneous magnetic field, which is the primary source of anisotropy, leads to a plane-symmetric Bianchi I model of the Universe. However, when free-streaming relativistic particles are present, they generate an anisotropic pressure which counteracts the one from the magnetic field such that the Universe becomes isotropized. We show that due to this effect, the CMB temperature anisotropy from a homogeneous magnetic field is significantly suppressed if the neutrino masses are smaller than 0.3 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Inhomogeneous anisotropic cosmology

In homogeneous and isotropic Friedmann-Robertson-Walker cosmology, the topology of the universe determines its ultimate fate. If the Weak Energy Condition is satisfied, open and flat universes must expand forever, while closed cosmologies can recollapse to a Big Crunch. A similar statement holds for homogeneous but anisotropic (Bianchi) universes. Here, we prove that arbitrarily inhomogeneous and anisotropic cosmologies with “flat” (including toroidal) and “open” (including compact hyperbolic) spatial topology that are initially expanding must continue to expand forever at least in some region at a rate bounded from below by a positive number, despite the presence of arbitrarily large density fluctuations and/or the formation of black holes. Because the set of 3-manifold topologies is countable, a single integer determines the ultimate fate of the universe, and, in a specific sense, most 3-manifolds are “flat” or “open”. Our result has important implications for inflation: if there is a positive cosmological constant (or suitable inflationary potential) and initial conditions for the inflaton, cosmologies with “flat” or “open” topology must expand forever in some region at least as fast as de Sitter space, and are therefore very likely to begin inflationary expansion eventually, regardless of the scale of the inflationary energy or the spectrum and amplitude of initial inhomogeneities and gravitational waves. Our result is also significant for numerical general relativity, which often makes use of periodic (toroidal) boundary conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Epitaxial Fe-Ge thin films on Ge(111): Morphology, structure, and magnetic properties versus stoichiometry

We have studied the growth and magnetic properties of thin Fe-Ge films synthesized (codeposited at room temperature and postannealed at 250 deg. C) on Ge(111) wafers versus stoichiometry. Morphology and crystal structure have been investigated in situ by means of scanning tunneling microscopy, low-energy electron diffraction, and x-ray photoelectron diffraction and ex situ with x-ray diffraction. The magnetic properties were characterized ex situ by conventional polar and longitudinal magneto-optical Kerr effect and transverse biased initial inverse susceptibility and torque measurements. It is found that the growth is epitaxial for Ge content up to approx48 at. % (approxFe{sub 1.1}Ge composition). In particular, the film is homogeneous and flat and adopts a crystalline structure of hexagonal symmetry derived from the B8{sub 2} (Ni{sub 2}In) structure over a wide stoichiometry range extending from Fe{sub 2}Ge to Fe{sub 1.1}Ge. The epitaxial orientation between the Ge substrate and the germanide layer is (0001)Fe-Ge||(111)Ge with [1120]Fe-Ge||110]Ge. We found however that the surface periodicity and the out-of-plane lattice parameter c evolve within this stoichiometry range and two distinct stoichiometry regimes appear on both sides of a critical stoichiometry (approxFe{sub 1.5}Ge). Indeed, from Fe{sub 2}Ge to Fe{sub 1.5}Ge the surface periodicity is p(2x2) and c continuously decreases with Fe content, whereas from Fe{sub 1.5}Ge to Fe{sub 1.1}Ge the surface periodicity is (sq root(3)xsq root(3))R30 deg. and c remains constant. These features have been interpreted as a clear fingerprint of a minor transformation of the crystalline structure but without any change in symmetry. This structural order transformation is discussed in relation to previous results reported in the case of macroscopic single-crystal Fe-Ge ingots. On both sides of the wide [Fe{sub 2}Ge,Fe{sub 1.1}Ge] composition range the layer is no more homogeneous. More precisely, for higher Fe content the film contains both the above mentioned Ni{sub 2}In-derived phase and a Fe-richer phase (probably bcc Fe) whereas for higher Ge content the layer is amorphous. Magnetic characterization showed in particular that the homogeneous Ni{sub 2}In-derived epilayers are ferromagnetic with a Curie temperature that varies drastically with the stoichiometry, rising up to a high T{sub C} value of approx450 K for the Fe-rich Fe{sub 1.9}Ge composition. Finally, whatever the stoichiometry, the magnetic easy axis of the homogeneous phase lies in the film plane and a small uniaxial anisotropy is superimposed on a sixfold order one that results from the hexagonal symmetry of the crystallographic structure.

36 MATERIALS SCIENCE↗

Stability of dynamic coherent states in intrinsic Josephson-junction stacks near internal cavity resonance.

Stacks of intrinsic Josephson junctions in the resistive state can by efficiently synchronized by the internal cavity mode resonantly excited by the Josephson oscillations. We study the stability of dynamic coherent states near the resonance with respect to small perturbations. Three states are considered: the homogeneous and alternating-kink states in zero magnetic field and the homogeneous state in the magnetic field near the value corresponding to half flux quantum per junction. We found two possible instabilities related to the short-scale and long-scale perturbations. The homogeneous state in modulated junction is typically unstable with respect to the short-scale alternating phase deformations unless the Josephson current is completely suppressed in one half of the stack. The kink state is stable with respect to such deformations and homogeneous state in the magnetic field is only stable within a certain range of frequencies and fields. Stability with respect to the long-range deformations is controlled by resonance excitations of fast modes at finite wave vectors and typically leads to unstable range of the wave vectors. This range shrinks with approaching the resonance and increasing the in-plane dissipation. As a consequence, in finite-height stacks the stability frequency range near the resonance increases with decreasing the height.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{alpha} particles and the ''pasta'' phase in nuclear matter

The effects of the {alpha} particles in nuclear matter at low densities are investigated within three different parametrizations of relativistic models at finite temperature. Both homogeneous and inhomogeneous matter (pasta phase) are described for neutral nuclear matter with fixed proton fractions and stellar matter subject to {beta} equilibrium and trapped neutrinos. In homogeneous matter, {alpha} particles are present only at densities below 0.02 fm{sup -3} and their presence decreases with increase of the temperature and, for a fixed temperature, the {alpha} particle fraction decreases for smaller proton fractions. A repulsive interaction is important to mimic the dissolution of the clusters in homogeneous matter. The effect of the {alpha} particles on the pasta structure is very small except close to the critical temperatures and/or proton fractions, when it may still predict a pasta phase while no pasta phase would occur in the absence of light clusters. It is shown that for densities above 0.01 fm{sup 3} the {alpha}-particle fraction in the pasta phase is much larger than that in homogeneous matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct numerical simulations of premixed and stratified flame propagation in turbulent channel flow

Here, direct numerical simulations are performed to investigate the transient upstream flame propagation (flashback) through homogeneous and fuel-stratified hydrogen-air mixtures transported in fully developed turbulent channel flows. Results indicate that, for both cases, the flame maintains steady propagation against the bulk flow direction, and the global flame shape and the local flame characteristics are both affected by the occurrence of fuel stratification. Globally, the mean flame shape undergoes an abrupt change when the approaching reactants transition from an homogeneous to a stratified mixing configuration. A V-shaped flame surface, whose leading-edge is located in the near-wall region, characterizes the nonstratified, homogeneous mixture case, while a U-shaped flame surface, whose leading edge propagates upstream at the channel centerline, distinguishes the case with fuel stratification (fuel-lean in the near-wall region and fuel-rich away from the wall). The characteristic thickness, wrinkling, and displacement speed of the turbulent flame brush are subject to considerable changes across the channel due to the dependence of the turbulence and mixture properties on the distance from the channel walls. More specifically, the flame transitions from a moderately wrinkled, thin-flamelet combustion regime in the homogeneous mixture case to a strongly wrinkled flame brush more representative of a thickened-flame combustion regime in the near-wall region of the fuel-stratified case. The combustion regime may be related to the Karlovitz number, and it is shown that a nominal channel-flow Karlovitz number, Ka ch in , based on the wall-normal variation of canonical turbulence ( t η =(ν/ε) 1/2 ) and chemistry ( t l = δ l / S l ) timescales in fully developed channel flow, compares well with an effective Karlovitz number, Ka ch fl , extracted from the present DNS datasets using conditionally sampled values of t η and t l in the immediate vicinity of the flame (0.1 < C < 0.3).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two key features influencing community assembly processes at regional scale: Initial state and degree of change in environmental conditions

Belowground microbial communities strongly influence ecosystem function such that predicting function may rely on understanding ecological processes that assemble communities. Uncertainty remains, however, in what governs the relative contributions of different ecological processes. To help fill this knowledge gap we test the general hypothesis that both initial state and degree of change in environmental conditions govern the relative contributions of different ecological assembly processes. To do so we leveraged regional-scale nutrient and organic matter addition experiments and used soil organic matter (SOM) as a proxy of integrated soil environmental conditions. Consistent with our hypothesis, we found that both the initial amount of SOM and the degree of change in SOM—in response to nutrient addition—influenced the relative contributions of different ecological assembly processes. These influences were most clearly observed at the regional scale, suggesting potential scale dependence. More specifically, nutrient additions homogenized bacterial community composition due to enhanced influences of homogenizing dispersal when SOM content was initially high. In contrast, nutrient additions led to divergence in community composition due to variable selection when initial SOM was low and/or when SOM increased significantly in response to nutrient additions. Our findings indicate important connections among initial conditions, degree of change in environmental variables, and microbial community assembly processes that may influence ecosystem processes. These conceptual inferences highlight a need to strengthen connections between ecological theory and biogeochemical modeling.

Feng, Youzhi↗

Sample-morphology effects on x-ray photoelectron peak intensities. II. Estimation of detection limits for thin-film materials

The authors show that the National Institute of Standards and Technology database for the simulation of electron spectra for surface analysis (SESSA) can be used to determine detection limits for thin-film materials such as a thin film on a substrate or buried at varying depths in another material for common x-ray photoelectron spectroscopy (XPS) measurement conditions. Illustrative simulations were made for a W film on or in a Ru matrix and for a Ru film on or in a W matrix. In the former case, the thickness of a W film at a given depth in the Ru matrix was varied so that the intensity of the W 4d{sub 5/2} peak was essentially the same as that for a homogeneous RuW{sub 0.001} alloy. Similarly, the thickness of a Ru film at a selected depth in the W matrix was varied so that the intensity of the Ru 3p{sub 3/2} peak matched that from a homogeneous WRu{sub 0.01} alloy. These film thicknesses correspond to the detection limits of each minor component for measurement conditions where the detection limits for a homogeneous sample varied between 0.1 at. % (for the RuW{sub 0.001} alloy) and 1 at. % (for the WRu{sub 0.01} alloy). SESSA can be similarly used to convert estimates of XPS detection limits for a minor species in a homogeneous solid to the corresponding XPS detection limits for that species as a thin film on or buried in the chosen solid.

36 MATERIALS SCIENCE↗

Differential dose volume histograms of Gamma Knife in the presence of inhomogeneities using MRI-polymer gel dosimetry and MC simulation

Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose volume histograms (DVHs) for single-shot irradiations of the Gamma Knife (GK) unit were used to investigate the effects of the presence of inhomogeneities on 3D dose distribution. The head phantom was a custom-built 16 cm diameter Plexiglas sphere. Inside the phantom, there is a cubic cutout for inserting the gel vials and another cutout for inserting the inhomogeneities. Following irradiation with the GK unit, the polymer gel phantoms were scanned with a 1.5 T MRI scanner. Comparing the results of measurement in homogeneous and heterogeneous phantoms revealed that inserting inhomogeneities inside the homogeneous phantom did not cause considerable disturbances on dose distribution in irradiation with 8 mm collimator within low isodose levels (<50%), which is essential for the dose sparing of sensitive structures. The results of simulation for homogeneous and inhomogeneous phantoms in irradiation with 18 mm collimator of the GK unit showed 23.24% difference in DVH within 90%-100% relative isodose level and also revealed that a significant part of the target (28.56%) received relative doses higher than the maximum dose, which exceeds the acceptance criterion (5%). Based on these results it is concluded that the presence of inhomogeneities inside the phantom can cause considerable errors in dose calculation within high isodose levels with respect to LGP prediction which assumes that the target is a homogeneous material. Moreover, it is demonstrated that the applied MC code is an accurate and stand-alone tool for 3D evaluation of dose distribution in irradiation with the GK unit, which can provide important, 3D plan evaluation criteria used in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation doses in cone-beam breast computed tomography: A Monte Carlo simulation study

Purpose: In this article, we describe a method to estimate the spatial dose variation, average dose and mean glandular dose (MGD) for a real breast using Monte Carlo simulation based on cone beam breast computed tomography (CBBCT) images. We present and discuss the dose estimation results for 19 mastectomy breast specimens, 4 homogeneous breast models, 6 ellipsoidal phantoms, and 6 cylindrical phantoms. Methods: To validate the Monte Carlo method for dose estimation in CBBCT, we compared the Monte Carlo dose estimates with the thermoluminescent dosimeter measurements at various radial positions in two polycarbonate cylinders (11- and 15-cm in diameter). Cone-beam computed tomography (CBCT) images of 19 mastectomy breast specimens, obtained with a bench-top experimental scanner, were segmented and used to construct 19 structured breast models. Monte Carlo simulation of CBBCT with these models was performed and used to estimate the point doses, average doses, and mean glandular doses for unit open air exposure at the iso-center. Mass based glandularity values were computed and used to investigate their effects on the average doses as well as the mean glandular doses. Average doses for 4 homogeneous breast models were estimated and compared to those of the corresponding structured breast models to investigate the effect of tissue structures. Average doses for ellipsoidal and cylindrical digital phantoms of identical diameter and height were also estimated for various glandularity values and compared with those for the structured breast models. Results: The absorbed dose maps for structured breast models show that doses in the glandular tissue were higher than those in the nearby adipose tissue. Estimated average doses for the homogeneous breast models were almost identical to those for the structured breast models (p=1). Normalized average doses estimated for the ellipsoidal phantoms were similar to those for the structured breast models (root mean square (rms) percentage difference=1.7%; p=0.01), whereas those for the cylindrical phantoms were significantly lower (rms percentage difference=7.7%; p<0.01). Normalized MGDs were found to decrease with increasing glandularity. Conclusions: Our results indicate that it is sufficient to use homogeneous breast models derived from CBCT generated structured breast models to estimate the average dose. This investigation also shows that ellipsoidal digital phantoms of similar dimensions (diameter and height) and glandularity to actual breasts may be used to represent a real breast to estimate the average breast dose with Monte Carlo simulation. We have also successfully demonstrated the use of structured breast models to estimate the true MGDs and shown that the normalized MGDs decreased with the glandularity as previously reported by other researchers for CBBCT or mammography.

60 APPLIED LIFE SCIENCES↗

A novel lateral disequilibrium inclusive (LDI) pencil-beam based dose calculation algorithm: Evaluation in inhomogeneous phantoms and comparison with Monte Carlo calculations

Purpose: Pencil-beam (PB) based dose calculation for treatment planning is limited by inaccuracies in regions of tissue inhomogeneities, particularly in situations with lateral electron disequilibrium as is present at tissue/lung interfaces. To overcome these limitations, a new ''lateral disequilibrium inclusive'' (LDI) PB based calculation algorithm was introduced. In this study, the authors evaluated the accuracy of the new model by film and ionization chamber measurements and Monte Carlo simulations. Methods: To validate the performance of the new LDI algorithm implemented in Corvus 09, eight test plans were generated on inhomogeneous thorax and pelvis phantoms. In addition, three plans were calculated with a simple effective path length (EPL) algorithm on the inhomogeneous thorax phantom. To simulate homogeneous tissues, four test plans were evaluated in homogeneous phantoms (homogeneous dose calculation). Results: The mean pixel pass rates and standard deviations of the gamma 4%/4 mm test for the film measurements were (96{+-}3)% for the plans calculated with LDI, (70{+-}5)% for the plans calculated with EPL, and (99{+-}1)% for the homogeneous plans. Ionization chamber measurements and Monte Carlo simulations confirmed the high accuracy of the new algorithm (dose deviations {<=}4%; gamma 3%/3 mm {>=}96%)Conclusions: LDI represents an accurate and fast dose calculation algorithm for treatment planning.

60 APPLIED LIFE SCIENCES↗

Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with {sup 125}I seeds (model I25.S16)

Purpose: (1) To measure absolute dose distributions in eye phantom for COMS eye plaques with {sup 125}I seeds (model I25.S16) using radiochromic EBT film dosimetry. (2) To determine the dose correction function for calculations involving the TG-43 formalism to account for the presence of the COMS eye plaque using Monte Carlo (MC) method specific to this seed model. (3) To test the heterogeneous dose calculation accuracy of the new version of Plaque Simulator (v5.3.9) against the EBT film data for this seed model. Methods: Using EBT film, absolute doses were measured for {sup 125}I seeds (model I25.S16) in COMS eye plaques (1) along the plaque's central axis for (a) uniformly loaded plaques (14-20 mm in diameter) and (b) a 20 mm plaque with single seed, and (2) in off-axis direction at depths of 5 and 12 mm for all four plaque sizes. The EBT film calibration was performed at {sup 125}I photon energy. MC calculations using MCNP5 code for a single seed at the center of a 20 mm plaque in homogeneous water and polystyrene medium were performed. The heterogeneity dose correction function was determined from the MC calculations. These function values at various depths were entered into PS software (v5.3.9) to calculate the heterogeneous dose distributions for the uniformly loaded plaques (of all four sizes). The dose distributions with homogeneous water assumptions were also calculated using PS for comparison. The EBT film measured absolute dose rate values (film) were compared with those calculated using PS with homogeneous assumption (PS Homo) and heterogeneity correction (PS Hetero). The values of dose ratio (film/PS Homo) and (film/PS Hetero) were obtained. Results: The central axis depth dose rate values for a single seed in 20 mm plaque measured using EBT film and calculated with MCNP5 code (both in ploystyrene phantom) were compared, and agreement within 9% was found. The dose ratio (film/PS Homo) values were substantially lower than unity (mostly between 0.8 and 0.9) for all four plaque sizes, indicating dose reduction by COMS plaque compared with homogeneous assumption. The dose ratio (film/PS Hetero) values were close to unity, indicating the PS Hetero calculations agree with those from the film study. Conclusions: Substantial heterogeneity effect on the {sup 125}I dose distributions in an eye phantom for COMS plaques was verified using radiochromic EBT film dosimetry. The calculated doses for uniformly loaded plaques using PS with heterogeneity correction option enabled were corroborated by the EBT film measurement data. Radiochromic EBT film dosimetry is feasible in measuring absolute dose distributions in eye phantom for COMS eye plaques loaded with single or multiple {sup 125}I seeds. Plaque Simulator is a viable tool for the calculation of dose distributions if one understands its limitations and uses the proper heterogeneity correction feature.

60 APPLIED LIFE SCIENCES↗

Four-dimensional Monte Carlo simulations demonstrating how the extent of intensity-modulation impacts motion effects in proton therapy lung treatments

Purpose: To compare motion effects in intensity modulated proton therapy (IMPT) lung treatments with different levels of intensity modulation.Methods: Spot scanning IMPT treatment plans were generated for ten lung cancer patients for 2.5Gy(RBE) and 12Gy(RBE) fractions and two distinct energy-dependent spot sizes (σ∼8–17 mm and ∼2–4 mm). IMPT plans were generated with the target homogeneity of each individual field restricted to <20% (IMPT{sub 20%}). These plans were compared to full IMPT (IMPT{sub full}), which had no restriction on the single field homogeneity. 4D Monte Carlo simulations were performed upon the patient 4DCT geometry, including deformable image registration and incorporating the detailed timing structure of the proton delivery system. Motion effects were quantified via comparison of the results of the 4D simulations (4D-IMPT{sub 20%}, 4D-IMPT{sub full}) with those of a 3D Monte Carlo simulation (3D-IMPT{sub 20%}, 3D-IMPT{sub full}) upon the planning CT using the equivalent uniform dose (EUD), V{sub 95} and D{sub 1}-D{sub 99}. The effects in normal lung were quantified using mean lung dose (MLD) and V{sub 90%}.Results: For 2.5Gy(RBE), the mean EUD for the large spot size is 99.9%± 2.8% for 4D-IMPT{sub 20%} compared to 100.1%± 2.9% for 4D-IMPT{sub full}. The corresponding values are 88.6%± 8.7% (4D-IMPT{sub 20%}) and 91.0%± 9.3% (4D-IMPT{sub full}) for the smaller spot size. The EUD value is higher in 69.7% of the considered deliveries for 4D-IMPT{sub full}. The V{sub 95} is also higher in 74.7% of the plans for 4D-IMPT{sub full}, implying that IMPT{sub full} plans experience less underdose compared to IMPT{sub 20%}. However, the target dose homogeneity is improved in the majority (67.8%) of plans for 4D-IMPT{sub 20%}. The higher EUD and V{sub 95} suggests that the degraded homogeneity in IMPT{sub full} is actually due to the introduction of hot spots in the target volume, perhaps resulting from the sharper in-target dose gradients. The greatest variations between the IMPT{sub 20%} and IMPT{sub full} deliveries are observed for patients with the largest motion amplitudes. These patients would likely be treated using gating or another motion mitigation technique, which was not the focus of this study.Conclusions: For the treatment parameters considered in this study, the differences between IMPT{sub full} and IMPT{sub 20%} are only likely to be clinically significant for patients with large (>20 mm) motion amplitudes.

61 RADIATION PROTECTION AND DOSIMETRY↗