Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Performance Building Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Autonomous Energy Grids

Current frameworks to monitor, control, and optimize large-scale energy systems are becoming increasingly inadequate because of significantly high penetration levels of variable generation and distributed energy resources being integrated into electric power systems; the deluge of data from pervasive metering of energy grids; and a variety of new market mechanisms, including multilevel ancillary services. This paper outlines the concept of autonomous energy grids (AEGs). These systems are supported by a scalable, reconfigurable, and self-organizing information and control infrastructure, are extremely secure and resilient (self-healing), and can self-optimize in real time to ensure economic and reliable performance while systematically integrating energy in all forms. AEGs rely on cellular building blocks that can self-optimize when isolated from a larger grid and participate in optimal operation when interconnected to a larger grid. This paper describes the key concepts and research necessary in the broad domains of optimization theory, control theory, big data analytics, and complex system theory and modeling to realize the AEG vision.

autonomous energy grids↗

Clemson University Wind Turbine Drivetrain Test Facility

In November of 2009, Clemson University was awarded a competitive grant from the U.S. Department of Energy to design, build and operate a facility for full-scale, highly accelerated mechanical testing of next-generation wind turbine drivetrain technologies. The primary goal of the project was to design, construct, commission, and operate a state-of-the-art sustainable facility that permits full-scale highly accelerated testing of advanced drivetrain systems for large wind turbines. The secondary goal was to meet the objectives of the American Recovery and Reinvestment Act of 2009, especially in job creation, and provide a positive impact on economically distressed areas in the United States, and preservation and economic recovery in an expeditious manner. The project was executed according to a managed cooperative agreement with the Department of Energy and was an extraordinary success. The resultant new facility is located in North Charleston, SC, providing easy transportation access by rail, road or ship and operates on an open access model such that it is available to the U.S. Wind Industry for research, analysis, and evaluation activities. The 72 m by 97 m facility features two mechanical dynamometer test bays for evaluating the torque and blade dynamic forces experienced by the rotors of wind turbine drivetrains. The dynamometers are rated at 7.5 MW and 15 MW of low speed shaft power and are configured as independent test areas capable of simultaneous operation. All six degrees of freedom, three linear and three rotational, for blade and rotor dynamics are replicated through the combination of a drive motor, speed reduction gearbox and a controllable hydraulic load application unit (LAU). This new LAU setup readily supports accelerated lifetime mechanical testing and load analysis for the entire drivetrain system of the nacelle and easily simulates a wide variety of realistic operating scenarios in a controlled laboratory environment. The development of these two dynamometer test rigs is the first significant achievement for the project. These test rigs embody a new manner of test due to the system configuration and completely new design with a free floating loading hub in the LAU. This project provided the catalyst for the advancement to this new test rig configuration that has been adopted by every significant wind turbine test rig constructed since the inception of this project. There are currently two different vendors supplying these new systems. Catalyzing this new design is the second major success of the project. With the increased market penetration of wind energy over the past decade, many regions and countries have developed specific electrical grid specifications and performance codes for large wind farms to ensure operational reliability and stability. These grid codes provide requirements for interconnection with the grid during low or high voltage phenomena, typically encountered during and after system fault events. Given the installed infrastructure of the Wind Turbine Drivetrain Testing Facility (WTDTF), a natural expansion of facility capability was to include the necessary equipment for performing fault ride-through evaluations of wind turbines to the Low Voltage Ride Through (LVRT) codes. Once the decision was made to expand the scope of the original grant into fault ride-through testing, it was clear that there are several markets, not just wind, which could benefit from this type of test and that simple fault ride-through testing could be extended into a broader scope of electrical testing capabilities. It was at this point that Clemson University was awarded a second grant to build a 15 MW Hardware-In-the-Loop (HIL) Grid Simulator in order to establish world class electrical testing capabilities to compliment the mechanical testing at the WTDTF. This third significant achievement resulted in the 15 MW HIL Grid Simulator as the corner stone of the Duke Energy eGRID Center and is collocated with the WTDTF in the SCE&G Energy Innovation Center at the new Facility in North Charleston, SC, USA. Before the eGRID was completed, it was recognized that the ability to test solar farm equipment was but a small step away thru the addition of enhanced equipment to provide for DC testing. In yet another expansion/success, a 2.5 MW rectifier system was designed and implemented by Clemson staff to enhance the Center’s capabilities. The program required over 250,000 man-hours of on-site construction labor reworking the brownfield facility on the former Navy Base, clearly satisfying one of the major goals of the Reinvestment Act. This was done while winning numerous awards for design and construction of the facility, including the Top US Project for 2014 from the Trade Journal Engineering News Record. The project was a major collaborative developmental activity managed by Clemson University staff that involved the DOE and many partners and organizations.

17 WIND ENERGY↗

Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations

Purpose: This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue in building a stationary system is to provide sufficient projection view-angles. Methods: A GATE (GEANT4 application for tomographic emission) Monte Carlo model was developed to simulate a two-detector stationary cardiac SPECT that uses segmented slant-hole collimators. Each detector contains seven segmented slant-hole sections that slant to a common volume at the rotation center. Consequently, 14 view-angles over 180° were acquired without any gantry rotation. The NCAT phantom was used for data generation and a tailored maximum-likelihood expectation-maximization algorithm was used for image reconstruction. Effects of limited number of view-angles and data truncation were carefully evaluated in the paper. Results: Simulation results indicated that the proposed segmented slant-hole stationary cardiac SPECT system is able to acquire sufficient data for cardiac imaging without a loss of image quality, even when the uptakes in the liver and kidneys are high. Seven views are acquired simultaneously at each detector, leading to 5-fold sensitivity gain over the conventional dual-head system at the same total acquisition time, which in turn increases the signal-to-noise ratio by 19%. The segmented slant-hole SPECT system also showed a good performance in lesion detection. In our prototype system, a short hole-length was used to reduce the dead zone between neighboring collimator segments. The measured sensitivity gain is about 17-fold over the conventional dual-head system. Conclusions: The GATE Monte Carlo simulations confirm the feasibility of the proposed stationary cardiac SPECT system with segmented slant-hole collimators. The proposed collimator consists of combined parallel and slant holes, and the image on the detector is not reduced in size.

60 APPLIED LIFE SCIENCES↗

Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery

Hydronic distribution systems have a long history, and are widely used in commercial buildings. As with mini-split heat pumps, hydronic systems using small terminal fan coils have the potential to provide high-quality comfort to homes that have small heating and cooling loads, but at a lower cost and with greater flexibility. These “ductless hydronic” distribution systems eliminate space requirements needed for ducting, eliminate duct thermal losses, and are easy to zone. Since heat pump chiller-heaters can be charged with refrigerant at the factory, hydronic systems also avoid refrigerant system faults such as incorrect charge and inadequate evacuation of lines that can lead to sub-standard performance. Other advantages include: reduction in the amount of energy required to deliver heating and cooling, reduced equipment cycling, and the potential for incorporating energy storage for peak load avoidance and demand response. Ductless hydronic systems are best suited for new homes, but with the relative ease of installing piping in attic spaces (for example under attic insulation), they are also suitable for existing homes that have old, leaky, and poorly insulated ducts. With a broader and more affordable product offering from manufacturers, installation guidelines, and contractor training, this method of distribution has significant potential to meet the space conditioning needs of high performance homes. The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers. The analysis focuses on ductless hydronic delivery systems that use water-to-air terminal units in each zone. This system type is applicable in all climate regions and can provide sensible and latent cooling and/or heating using a single hot and chilled water source such as a heat pump, or a separate water heater and chiller. Results of TRNSYS modeling indicate that annual heating and cooling energy use (site and source) can be reduced by up to 22% when substituting pipes, pump, small distributed fan coils, and a water-to-air heat pump for the ducts, air handler, indoor coil, and conventional air-to-air heat pump unit of similar rating as the air-to-water unit. Of the 22% savings, on average 36% is attributable to the lower energy required by pumps and small fans vs. air handler blowers, and 64% to the reduced losses from pipes as compared to ducts. Using the modeled energy savings and estimated costs, hydronic distribution appears to be economically viable in three of the four climates evaluated. Other current field studies of air-to-water heat pumps coupled to radiant floor systems are demonstrating heat pump performance that exceeds seasonal performance calculated using a standard heat pump performance map (German, 2011a, German, 2011b). Hydronic distribution systems can meet sensible and latent cooling needs in all climates. Major barriers to widespread application include the lack of low-cost, small, ceiling-mounted fan coils, and the limited availability and higher cost of air-to-water heat pumps. The latter could be overcome by the production of an add-on refrigerant-to-water conversion kit that could be used to adapt any heat pump to serve as a water chiller-heater. Development of accurate performance maps and additional data on field performance are areas that should be targeted by future research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fort Benning Indianhead Townhome Renovations

The NAHB Research Center partnered with production builder Winchester/Camberley Homes to build a DOE Building America New Construction Test House (NCTH). This single family, detached house, located in the mixed-humid climate zone of Silver Spring, MD, was completed in June 2011. The primary goal for this house was to improve energy efficiency by 30% over the Building America B10 benchmark by developing and implementing an optimized energy solutions package design that could be cost effectively and reliably constructed on a production basis using quality management practices. The intent of this report is to outline the features of this house, discuss the implementation of the energy efficient design, and report on short-term testing results. During the interactive design process of this project, numerous iterations of the framing, air sealing, insulation, and space conditioning systems were evaluated for energy performance, cost, and practical implementation. The final design featured numerous advanced framing techniques, high levels of insulation, and the HVAC system entirely within conditioned space. Short-term testing confirmed a very tight thermal envelope and efficient and effective heating and cooling. In addition, relevant heating, cooling, humidity, energy, and wall cavity moisture data will be collected and presented in a future long-term report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temporal and Spatial Comparison of Gridded TMY, TDY, and TGY Data Sets

Typical Meteorological Year (TMY) data sets provide industry standard resource information for building designers and are commonly used by the solar industry to estimate photovoltaic and concentrating solar power system performance. Historically, TMY data sets were only available for certain station locations, but current TMY data sets are available on the same grid as the National Solar Radiation Database data and are referred to as the gridded TMY. In this report, a comparison of TMY, typical direct (normal irradiance) year (TDY), and typical global (horizontal irradiance) year (TGY) data sets were performed to better understand the impact of ancillary weather variables upon them. These analyses identified geographical areas of high and low temporal and spatial variability, thereby providing insight into the representativeness of a particular TMY data set for use in renewable energy as well as other applications.

14 SOLAR ENERGY↗

Harnessing Relativistic Laser Plasmas to Generate Intense Ion Beams: A Plasma Science Frontier White Paper

Optical lasers with high intensity (> 10 19 W/cm 2 ), high power (> 100 TW) and high energy (> 50 J) are enabling research that is expanding the frontiers of physics. Some of the research opportunities and importance are described in several reports. Here we highlight a prominent one: harnessing relativistic laser plasmas to generate intense ion beams, much more intense than it is possible with conventional particle-acceleration technology. This topic is important in two ways. On the one hand, it represents exceedingly exciting science in plasma physics and extreme electrodynamics (i.e., “high-field” physics). On the other hand, it enables advanced technology for advancing other fields of science, for societal applications (e.g., fast ignition8) and for national defense. There are tremendous opportunities for continued progress in existing laser facilities in the US (with laser intensities up to ~ 10 21 W/cm 2 , such as the Trident Laser Facility) provided modest funding support and reorientation of these lasers as national user facilities. Longer term, there are also great scientific opportunities for the US by extending our capabilities to intensities of ~ 10 22 W/cm 2 and beyond with shaped laser pulses of intermediate duration (~ 100 fs), to complement high intensity, shorter pulse length lasers planned worldwide. Such a complementary US facility would in fact excel in the ion-beam generation mission proposed here. At ~ 10 22 W/cm 2 and beyond, besides meeting the requirements for important societal applications of intense ion beams, novel high-field physics becomes important and amenable to study. That includes e.g., radiation self-force for electrons, and direct coupling of the laser to the ions (not just to electrons and then indirectly to the ions). These new physics in turn may open new technological opportunities, such as x-ray and gamma-ray-beam sources and new ion-acceleration mechanisms. It is hard to overstate the impact of particle accelerators starting in the last century to the present. Accelerators have had profound impact in society, both as a key enabling experimental tool for the modern scientific edifice, as well as for societal applications such as cancer therapy. Conventional accelerator technology is bumping against two main limitations. One is particle energy (at a reasonable size and cost) rooted in the ~ 25 MeV/m gradient limit from electrical breakdown of conventional accelerator structures. The second is beam intensity, limited by current and space-charge stability of conventional (non-neutral) particle beams. The former issue is being addressed in ingenious ways by “dielectric accelerators” which use high-power, low-energy lasers to set up transient-high fields in dielectric microstructures. These devices promise to advance the state of the art in acceleration gradients, but of course cannot address the intensity limitations. Ultimately, the highest performance is going to require a plasma as the acceleration medium. Plasmas can support the highest accelerating potential gradients and the highest currents. Moreover, by delivering neutralized beams (ions co-moving with unbound electrons), the usual current and space-charge limits can be circumvented. Realizing the highest ion energies and intensities requires a high-power density source to drive the system. Intense, high-power, high-energy lasers represent an ideal drive source, provided the physics can be understood and controlled, i.e., a challenge proposed here. To meet that challenge, the science community can build on the significant progress over the last decade, experimentally, computationally and theoretically.

43 PARTICLE ACCELERATORS↗

Fort Benning Indianhead Townhome Renovations

The NAHB Research Center partnered with production builder Winchester/Camberley Homes to build a DOE Building America New Construction Test House (NCTH). This single family, detached house, located in the mixed-humid climate zone of Silver Spring, MD, was completed in June 2011. The primary goal for this house was to improve energy efficiency by 30% over the Building America B10 benchmark by developing and implementing an optimized energy solutions package design that could be cost effectively and reliably constructed on a production basis using quality management practices. The intent of this report is to outline the features of this house, discuss the implementation of the energy efficient design, and report on short-term testing results. During the interactive design process of this project, numerous iterations of the framing, air sealing, insulation, and space conditioning systems were evaluated for energy performance, cost, and practical implementation. The final design featured numerous advanced framing techniques, high levels of insulation, and the HVAC system entirely within conditioned space. Short-term testing confirmed a very tight thermal envelope and efficient and effective heating and cooling. In addition, relevant heating, cooling, humidity, energy, and wall cavity moisture data will be collected and presented in a future long-term report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

Performance Evaluation of Liquid-Cooled Open Stand-Alone Refrigerated Cases

This project is part of a joint effort between Commonwealth Edison Company (ComEd) and the National Renewable Energy Laboratory (NREL) to evaluate the energy and demand savings potential of emerging efficient buildings technologies. This project quantifies the energy efficiency benefits from retrofitting an air-cooled, constant-speed compression, self-contained medium-temperature open-vertical display case with a high efficiency water-cooled condensing unit. In addition to a water-cooled heat rejection mechanism, the high-efficiency condensing unit utilizes a variable-speed compressor, electronic expansion valve and advanced controls system. The focus of this project, however, was mainly on capturing the energy savings potentials of the water-cooled condenser, variable-speed compression and electronic expansion valve, and not on the advanced controls. The results of this evaluation will be considered by ComEd and CLEAResult for future energy efficiency rebate offerings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new event builder for CMS Run II

The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider (LHC) assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of 100 GB/s to the high-level trigger (HLT) farm. The DAQ system has been redesigned during the LHC shutdown in 2013/14. The new DAQ architecture is based on state-of-the-art network technologies for the event building. For the data concentration, 10/40 Gbps Ethernet technologies are used together with a reduced TCP/IP protocol implemented in FPGA for a reliable transport between custom electronics and commercial computing hardware. A 56 Gbps Inniband FDR CLOS network has been chosen for the event builder. This paper discusses the software design, protocols, and optimizations for exploiting the hardware capabilities. In conclusion, ee present performance measurements from small-scale prototypes and from the full-scale production system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributing Power Grid State Estimation on HPC Clusters A System Architecture Prototype

The future power grid is expected to further expand with highly distributed energy sources and smart loads. The increased size and complexity lead to increased burden on existing computational resources in energy control centers. Thus the need to perform real-time assessment on such systems entails efficient means to distribute centralized functions such as state estimation in the power system. In this paper, we present our early prototype of a system architecture that connects distributed state estimators individually running parallel programs to solve non-linear estimation procedure. The prototype consists of a middleware and data processing toolkits that allows data exchange in the distributed state estimation. We build a test case based on the IEEE 118 bus system and partition the state estimation of the whole system model to available HPC clusters. The measurement from the testbed demonstrates the low overhead of our solution.

Distributed architecture↗

Wyandotte Neighborhood Stabilization Program: Retrofit of Two Homes

The Wyandotte NSP2 project aims to build 20 new houses and retrofit 20 existing houses in Wyandotte, MI. Wyandotte is part of a Michigan State Housing Development Authority-led consortium that is funded by HUD under the NSP2 program. The City of Wyandotte has also been awarded DOE EE&CBG funds that are being used to develop a district ground source heat pump (GSHP) system to service the project. This report details the retrofit of two existing houses in the program, and examines the energy efficiency recommendations for the homes. The report will be of interest to anyone planning an affordable, high performance retrofit of an existing home in a cold climate zone. Information from this report will also be useful to retrofit or weatherization program staff as some of the proposed retrofit solutions will apply to a wide range of projects. Preliminary results from the first complete house suggest that the technology package employed (which includes spray foam insulation and insulating sheathing) does meet the specific whole house water, air, and thermal control requirements, as well as, the project’s affordability goals. Monitoring of the GSHP system has been recommended and analysis of this information is not yet available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WIPP - February 2014 operational events and the compliance re-certification application (CRA) 2014 - 15293

On Wednesday, February 5, 2014, an underground mine fire involving a salt haul truck occurred at the Waste Isolation Pilot Plant (WIPP). There were 86 workers in the mine when the fire occurred. All workers were evacuated. Nine days later, on Friday, February 14, 2014, there was an incident in the underground repository at WIPP which resulted in the release of americium and plutonium from one or more transuranic (TRU) waste containers into the environment. The release was detected by an underground continuous air monitor and then directed through high-efficiency particulate air (HEPA) filter banks located in the surface exhaust building. However, a measurable portion bypassed the HEPA filters via leakage through two ventilation system dampers and was discharged directly to the environment from an exhaust duct. No personnel were determined to have received external contamination; however, some individuals that were on site were identified through bioassay to have initially tested positive for low level amounts of internal contamination. Trace amounts of americium and plutonium were detected off-site.While significant to day-to-day operations, these events have no impact to the long-term performance of the repository. Because WIPP's re-certification is based solely on the post-closure performance of the repository (40 CFR 191, Subparts B and C), these recent events do not affect the long-term performance predictions or its technical and scientific basis. In this paper we will further explore the requirements for WIPP's re-certification, and the basis for our contention that the recent WIPP operational events do not impact long-term repository performance or have any implications on salt as a geologic disposal media, and that re-certification efforts should continue uninterrupted. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decommissioning, Decontamination, and Disposal of LLW-LL, and ILW-LL at a Former Rare Earths Processing Facility in Malaysia - 19087

Geosyntec Consultants, Inc. (Geosyntec) was the design-build Contractor for a project involving the remediation and disposal of low level (LLW-LL and ILW-LL) NORM and TENORM wastes at a former rare earth processing facility in Malaysia. These sites were associated with a plant that extracted rare earth elements from local tin ores. Because of the naturally occurring radioactivity contained in the raw materials, these productions resulted in by-products and residues containing LLW-LL and ILW-LL thorium hydroxide and uranium hydroxide. The total mass of uranium (∼120 tons) and thorium (∼1,200 tons) managed in a single repository required the project design incorporate requirements related to inventory, security and safeguards around nuclear precursor materials. The requirement to consider a performance over a period of more than 10,000 years led to significant challenges in design and modeling of the disposal facility as this disposal facility was purposely designed and permitted as a final disposal for the LLW-LL and ILW-LL. The first phase of the project was the decommissioning, decontamination, and demolition of the 14- acre former rare earth processing plant and excavation of contaminated soils, construction of an engineered cell at the repository for waste disposal, and transportation and disposal of the waste materials into the cell. Final status surveys were carried out to allow the site to be successfully released by the Malaysian regulatory authorities as a clean site for re-development as common industrial use. Over 11,000 loads of material, including approximately 75,000 cubic meters of excavated soils and plant debris, were transported in specially designed steel transport boxes on public roads for disposal in the engineered cell. The second phase of the project included the design and construction of a second engineered cell, enhanced with protective barrier systems and a final cover system constructed of natural materials. Ancillary facilities such as substations, offices, processing buildings, and wastewater treatment plants were constructed to support retrieval and processing of the materials from more than 87,000 individual drums using a semi-automated process. The drums, waste packages, and other materials in the storage facility were systematically extracted, sorted, inventoried, solidified using Portland cement, transported, and disposed in the cell. All temporary facilities were decontaminated, demolished, and disposed in the cell. Radiological inventory and radiation safety programs were implemented to quantify the waste activity and to control exposure to workers and the public during the project. The total mass of radioactive contaminated waste disposed in the two projects is nearly 200,000 tons. The projects were carried out under a high level of scrutiny from Malaysian and international regulatory bodies. Between 2014 and 2017, performance monitoring and modeling activities were carried out to demonstrate that the disposal facility was performing in accordance with design requirements established by regulatory agencies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Expert Meeting Report: Achieving the Best Installed Performance from High-Efficiency Residential Gas Furnaces

This report describes a Building America expert meeting hosted on July 28, 2011, by the Partnership for Advanced Residential Retrofit (PARR) team. The purpose of this meeting was to identify installation practices that provide the best installed efficiency for residential gas furnaces, explain how AFUE and field efficiency can differ, and investigate the impact of installation practices on the efficiency and long-term durability of the furnace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DynamiteNSM

DynamiteNSM is a free Network Security Monitor (NSM), built on top of several leading, enterprise-grade technologies. The tool provides network and cybersecurity operators with holistic insights into their networks while giving them the ability to deep-dive into lower-level activities. The solution presents powerful dashboards, giving comprehensive view into performance and threat-based metrics. Dynamite-NSM can be easily deployed in different environments including high-speed data centers, small-to-large enterprises, IoT & industrial networks, and even at home. Dynamite-NSM handles massive volumes of network traffic through scalable ingestion and optimized network sensors. The solution includes two key components: the agent and the monitor. The agent analyzes and forwards network events, while the monitor processes incoming events and displays analytic information. The monitor component builds upon the OpenSearch stack and is coupled with network packet inspection by Zeek and Suricata. Dynamite-NSM is designed to be deployed very quickly with minimal configuration. Unlike many other tools, it can be installed and managed with a standalone command-line utility. The system is inherently passive without disruption to the network. There is no need to install agents on every computer, perform network scans, or directly interact with network assets.

Becker, Jamin↗