Development of a Thermal Management System for Electrified Aircraft

This paper describes the development and optimization of a conceptual thermal management system for electrified aircraft. Here, a vertical takeoff and landing (VTOL) vehicle is analyzed with the following electrically sourced heat loads considered: motors, generators, rectifiers, and inverters. The vehicle will employ liquid-cooling techniques in order to acquire, transport, and reject waste heat from the vehicle. The purpose of this paper is to threefold: 1) Present a potential modeling framework for system level thermal management system simulation, 2) Analyze typical system characteristics, and 3) Perform optimization on a system developed for a specific vehicle to minimize weight gain, power utilization, and drag. Additionally, the paper will study the design process, specifically investigating the differences between steady state and transient sizing, comparing simulation techniques with a lower fidelity option and quantifying expected error.

Chapman, Jeffryes W.↗

Reducing Operating Temperature in Photovoltaic Modules

Reducing the operating temperature of photovoltaic modules increases their efficiency and lifetime. This can be achieved by reducing the production of waste heat or by improving the rejection of waste heat. We tested, using a combination of simulation and experiment, several thermal modifications in each category. To predict operating temperature and energy yield changes in response to changes to the module, we implemented a physics-based transient simulation framework based almost entirely on measured properties. The most effective thermal modifications reduced the production of waste heat by reflecting unusable light from the cell or the module. Consistent with previous results and verified in this work through year-long simulations, the ideal reflector resulted in an annual irradiance-weighted temperature reduction of 3.8 K for crystalline silicon (c-Si). Our results illustrate that more realistic reflector concepts must balance detrimental optical effects with the intended thermal effects to realize the optimal energy production advantage. Methods improving thermal conductivity or back-side emissivity showed only modest improvements of less than 1 K. We also studied a GaAs module, which uses high-efficiency and high-subbandgap reflectivity to operate at an annual irradiance-weighted temperature 12 K cooler than that of a c-Si module under the same conditions.

14 SOLAR ENERGY↗

A pumped, two-phase flow heat transport system for orbiting instrument payloads

A pumped two-phase (heat absorption/heat rejection) thermal transport system for orbiting instrument payloads is investigated. The thermofluid characteristics necessary for the system design are discussed. A preliminary design with a series arrangement of four instrument heat stations and six radiators in a single loop is described in detail, and the total mass is estimated to be 134 kg, with the radiators, instrument heat stations, and fluid reservoir accounting for approximately 86, 24, and 12 kg, respectively. The evaluation of preliminary test results shows that the system has potential advantages; however, further research is necessary in the areas of one-g and zero-g heat transfer coefficients/fluid regimes, fluid by-pass temperature control, and reliability of small pumps.

Fowle, A. A.↗

Corrosion testing of metals in contact with calcium chloride hexahydrate used for thermal energy storage

Thermal energy storage (TES) using a phase change material (PCM) has been proposed as a supplemental cooling system to improve the performance of power plant air‐cooled condensers (ACCs). In this proposed system, frozen PCM would remove heat from plant's condensing steam during the day, which would melt the PCM. The PCM would be frozen at night as its stored heat is rejected to the cooler atmosphere. Calcium chloride hexahydrate (CaCl 2 · 6H 2 O) is an attractive material to serve as a PCM in this innovative system due to its appropriate melting temperature, low price, and relatively high latent heat of fusion. The corrosion of container materials is a major challenge in using CaCl 2 · 6H 2 O. Any material used needs to survive constant exposure to the salt for several years to ensure a long operational life for the system. In this study, the corrosion behavior of four metals in contact with CaCl 2 · 6H 2 O was experimentally investigated. Three different temperature conditions and two pH level conditions were considered under static metal exposure conditions.

Ren, S. J.↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

High Specific Power Motors in LN2 and LH2

A switched reluctance motor has been operated in liquid nitrogen (LN2) with a power density as high as that reported for any motor or generator. The high performance stems from the low resistivity of Cu at LN2 temperature and from the geometry of the windings, the combination of which permits steady-state rms current density up to 7000 A/cm2, about 10 times that possible in coils cooled by natural convection at room temperature. The Joule heating in the coils is conducted to the end turns for rejection to the LN2 bath. Minimal heat rejection occurs in the motor slots, preserving that region for conductor. In the end turns, the conductor layers are spaced to form a heat-exchanger-like structure that permits nucleate boiling over a large surface area. Although tests were performed in LN2 for convenience, this motor was designed as a prototype for use with liquid hydrogen (LH2) as the coolant. End-cooled coils would perform even better in LH2 because of further increases in copper electrical and thermal conductivities. Thermal analyses comparing LN2 and LH2 cooling are presented verifying that end-cooled coils in LH2 could be either much longer or could operate at higher current density without thermal runaway than in LN2.

Brown, Gerald V.↗

High Specific Power Motors in LN2 and LH2

A switched reluctance motor has been operated in liquid nitrogen (LN2) with a power density as high as that reported for any motor or generator. The high performance stems from the low resistivity of Cu at LN2 temperature and from the geometry of the windings, the combination of which permits steady-state rms current density up to 7000 A/sq cm, about 10 times that possible in coils cooled by natural convection at room temperature. The Joule heating in the coils is conducted to the end turns for rejection to the LN2 bath. Minimal heat rejection occurs in the motor slots, preserving that region for conductor. In the end turns, the conductor layers are spaced to form a heat-exchanger-like structure that permits nucleate boiling over a large surface area. Although tests were performed in LN2 for convenience, this motor was designed as a prototype for use with liquid hydrogen (LH2) as the coolant. End-cooled coils would perform even better in LH2 because of further increases in copper electrical and thermal conductivities. Thermal analyses comparing LN2 and LH2 cooling are presented verifying that end-cooled coils in LH2 could be either much longer or could operate at higher current density without thermal runaway than in LN2.

Brown, Gerald V.↗

Chemical Looping Combustion Kinetics

One of the most promising methods of capturing CO{sub 2} emitted by coal-fired power plants for subsequent sequestration is chemical looping combustion (CLC). A powdered metal oxide such as NiO transfers oxygen directly to a fuel in a fuel reactor at high temperatures with no air present. Heat, water, and CO{sub 2} are released, and after H{sub 2}O condensation the CO{sub 2} (undiluted by N{sub 2}) is ready for sequestration, whereas the nickel metal is ready for reoxidation in the air reactor. In principle, these processes can be repeated endlessly with the original nickel metal/nickel oxide participating in a loop that admits fuel and rejects ash, heat, and water. Our project accumulated kinetic rate data at high temperatures and elevated pressures for the metal oxide reduction step and for the metal reoxidation step. These data will be used in computational modeling of CLC on the laboratory scale and presumably later on the plant scale. The oxygen carrier on which the research at Utah is focused is CuO/Cu{sub 2}O rather than nickel oxide because the copper system lends itself to use with solid fuels in an alternative to CLC called 'chemical looping with oxygen uncoupling' (CLOU).

01 COAL, LIGNITE, AND PEAT↗

Power Conversion with a Stirling Cycle for Venus Surface Mission

The light-filtering characteristic of the dense, mostly-CO2 atmosphere of Venus, combined with the high atmospheric cloud cover, relegates the surface mission use of photovoltaic power systems and beckons for the independence and reliability of a nuclear-powered energy source. A multi-faceted Venus mission study was completed at NASA GRC in December of 2003 that resulted in the preliminary design of a helium- charged, kinematic Stirling converter, which is powered by nuclear, General Purpose Heat Source (GPHS) modules. The kinematic, Stirling power converter is configured to drive an electronics and sensor cooler in addition to a generator for electrical power. This paper briefly describes the design process and also describes and summarizes key features of the Stirling power converter preliminary design concept. With an estimated total efficiency of 23.4%, the power converter drives the electronics and sensor cooler, and also produces 100 watts of electricity. The converter rejects waste heat at a hot sink temperature of 500 C.

Mellott, Ken↗

Radiation heat transfer calculations for the uranium fuel-containment region of the nuclear light bulb engine.

Calculation results are reviewed of the radiant heat transfer characteristics in the fuel and buffer gas regions of a nuclear light bulb engine based on the transfer of energy by thermal radiation from gaseous uranium fuel in a neon vortex, through an internally cooled transparent wall, to seeded hydrogen propellant. The results indicate that the fraction of UV energy incident on the transparent walls increases with increasing power level. For the reference engine power level of 4600 megw, it is necessary to employ space radiators to reject the UV radiated energy absorbed by the transparent walls. This UV energy can be blocked by employing nitric oxide and oxygen seed gases in the fuel and buffer gas regions. However, this results in increased UV absorption in the buffer gas which also requires space radiators to reject the heat load.

Rodgers, R. J.↗

Thermal Control System Architecture and Technology Challenges for a Lunar Surface Habitat

NASA’s current plans for exploration of the Lunar South Pole region include a Surface Habitat (SH) to provide up to 60-day habitability for a crew of four. The SH concept is comprised of several elements including an inflatable volume for the habitable space and a metallic airlock for access to a pressurized rover and other surface assets. A conceptual architecture for the SH Thermal Control System (TCS) is presented. A TCS dual loop design is utilized with a water/propylene glycol mix for the internal crew spaces and an external loop with low temperature coolant. The internal loop is partitioned into low and moderate temperature service with a sublimator available for operational scenarios prior to thermal radiator deployment (or redeployment). Waste heat is rejected through thermal radiators contained in the external loop. Optimization of the thermal radiator geometry/orientation as well as the TCS internal/external loop architecture is accomplished via analytical models of the system. Low mass, dust tolerant, deployable/retractable thermal radiators (in partial gravity) and thermal control surfaces, along with accommodating infrequent eclipse periods lasting up to 100 hours, present the major technology challenges. Mitigation strategies to reduce the energy needed to maintain the SH and associated systems above survival temperature limits during the eclipse period are considered in the paper. Options include retractable radiators, re-generable heat exchangers, temperature excursions, thermal energy storage and optimized inflatable optical properties. TCS sensitivity to potential SH Electrical Power System (EPS) growth is also a consideration for both operational and dormant mission phases.

Thermal Control System↗

Thermal Control System Architecture and Technology Challenges for a Lunar Surface Habitat

NASA’s current plans for exploration of the Lunar South Pole region include a Surface Habitat (SH) to provide up to 60-day habitability for a crew of four. The SH concept is comprised of several elements including an inflatable volume for the habitable space and a metallic airlock for access to a pressurized rover and other surface assets. A conceptual architecture for the SH Thermal Control System (TCS) is presented. A TCS dual loop design is utilized with a water/propylene glycol mix for the internal crew spaces and an external loop with low temperature coolant. The internal loop is partitioned into low and moderate temperature service with a sublimator available for operational scenarios prior to thermal radiator deployment (or redeployment). Waste heat is rejected through thermal radiators contained in the external loop. Optimization of the thermal radiator geometry/orientation as well as the TCS internal/external loop architecture is accomplished via analytical models of the system. Low mass, dust tolerant, deployable/retractable thermal radiators (in partial gravity) and thermal control surfaces, along with accommodating infrequent eclipse periods lasting up to 100 hours, present the major technology challenges. Mitigation strategies to reduce the energy needed to maintain the SH and associated systems above survival temperature limits during the eclipse period are considered in the paper. Options include retractable radiators, re-generable heat exchangers, temperature excursions, thermal energy storage and optimized inflatable optical properties. TCS sensitivity to potential SH Electrical Power System (EPS) growth is also a consideration for both operational and dormant mission phases.

Thermal Control System↗

Low-temperature fuel cell systems for commercial airplane auxiliary power.

This presentation briefly describes the ongoing study of fuel cell systems on-board a commercial airplane. Sandia's current project is focused on Proton Exchange Membrane (PEM) fuel cells applied to specific on-board electrical power needs. They are trying to understand how having a fuel cell on an airplane would affect overall performance. The fuel required to accomplish a mission is used to quantify the performance. Our analysis shows the differences between the base airplane and the airplane with the fuel cell. There are many ways of designing a system, depending on what you do with the waste heat. A system that requires ram air cooling has a large mass penalty due to increased drag. The bottom-line impact can be expressed as additional fuel required to complete the mission. Early results suggest PEM fuel cells can be used on airplanes with manageable performance impact if heat is rejected properly. For PEMs on aircraft, we are continuing to perform: (1) thermodynamic analysis (investigate configurations); (2) integrated electrical design (with dynamic modeling of the micro grid); (3) hardware assessment (performance, weight, and volume); and (4) galley and peaker application.

30 DIRECT ENERGY CONVERSION↗

Extension of the Supercritical Carbon Dioxide Brayton Cycle to Low Reactor Power Operation: Investigations using the Coupled ANL Plant Dynamics Code-SAS4A/SASSYS-1 Liquid Metal Reactor Code System

Significant progress has been made on the development of a control strategy for the supercritical carbon dioxide (S-CO 2 ) Brayton cycle enabling removal of power from an autonomous load following Sodium-Cooled Fast Reactor (SFR) down to decay heat levels such that the S-CO 2 cycle can be used to cool the reactor until decay heat can be removed by the normal shutdown heat removal system or a passive decay heat removal system such as Direct Reactor Auxiliary Cooling System (DRACS) loops with DRACS in-vessel heat exchangers. This capability of the new control strategy eliminates the need for use of a separate shutdown heat removal system which might also use supercritical CO 2 . It has been found that this capability can be achieved by introducing a new control mechanism involving shaft speed control for the common shaft joining the turbine and two compressors following reduction of the load demand from the electrical grid to zero. Following disconnection of the generator from the electrical grid, heat is removed from the intermediate sodium circuit through the sodium-to-CO 2 heat exchanger, the turbine solely drives the two compressors, and heat is rejected from the cycle through the CO 2 -to-water cooler. To investigate the effectiveness of shaft speed control, calculations are carried out using the coupled Plant Dynamics Code-SAS4A/SASSYS-1 code for a linear load reduction transient for a 1000 MWt metallic-fueled SFR with autonomous load following. No deliberate motion of control rods or adjustment of sodium pump speeds is assumed to take place. It is assumed that the S-CO 2 turbomachinery shaft speed linearly decreases from 100 to 20% nominal following reduction of grid load to zero. The reactor power is calculated to autonomously decrease down to 3% nominal providing a lengthy window in time for the switchover to the normal shutdown heat removal system or for a passive decay heat removal system to become effective. However, the calculations reveal that the compressor conditions are calculated to approach surge such that the need for a surge control system for each compressor is identified. Thus, it is demonstrated that the S-CO 2 cycle can operate in the initial decay heat removal mode even with autonomous reactor control. Because external power is not needed to drive the compressors, the results show that the S-CO 2 cycle can be used for initial decay heat removal for a lengthy interval in time in the absence of any off-site electrical power. The turbine provides sufficient power to drive the compressors. Combined with autonomous reactor control, this represents a significant safety advantage of the S-CO 2 cycle by maintaining removal of the reactor power until the core decay heat falls to levels well below those for which the passive decay heat removal system is designed. The new control strategy is an alternative to a split-shaft layout involving separate power and compressor turbines which had previously been identified as a promising approach enabling heat removal from a SFR at low power levels. The current results indicate that the split-shaft configuration does not provide any significant benefits for the S-CO 2 cycle over the current single-shaft layout with shaft speed control. It has been demonstrated that when connected to the grid the single-shaft cycle can effectively follow the load over the entire range. No compressor speed variation is needed while power is delivered to the grid. When the system is disconnected from the grid, the shaft speed can be changed as effectively as it would be with the split-shaft arrangement. In the split-shaft configuration, zero generator power means disconnection of the power turbine, such that the resulting system will be almost identical to the single-shaft arrangement. Without this advantage of the split-shaft configuration, the economic benefits of the single-shaft arrangement, provided by just one turbine and lower losses at the design point, are more important to the overall cycle performance. Therefore, the single-shaft configuration shall be retained as the reference arrangement for S-CO 2 cycle power converter preconceptual designs. Improvements to the ANL Plant Dynamics Code have been carried out. The major code improvement is the introduction of a restart capability which simplifies investigation of control strategies for very long transients. Another code modification is transfer of the entire code to a new Intel Fortran complier; the execution of the code using the new compiler was verified by demonstrating that the same results are obtained as when the previous Compaq Visual Fortran compiler was used.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data Center Waste Heat as an Emerging Urban Thermal Hazard: First Field Measurements of Neighborhood-Scale Air Temperature Impacts

Data centers are among the fastest-growing sources of concentrated anthropogenic heat in urban environments. Despite heat flux densities that exceed peak solar irradiance by a factor of 2–6, their thermal impacts on adjacent communities have never been directly measured or reported in the peer-reviewed literature. This short communication addresses that gap by presenting the first vehicle-based traverse measurements of air temperature in residential neighborhoods downwind of operational data centers. Five traverses at four facilities in the Phoenix, Arizona metropolitan area, ranging from a 36 MW single-building data center in Mesa to a 169 MW colocation campus in Chandler, reveal downwind air temperature warming as high as 2.2 °C, with average downwind air temperatures 0.7–0.9 °C warmer than corresponding upwind areas. Thermal signatures were detectable at distances up to 500 m from facility perimeters. The 36 MW Mesa facility rejects waste heat equivalent to the electricity consumption of approximately 40,000 households, while the 169 MW Chandler campus is equivalent to over 180,000 households, both concentrated into footprints smaller than a single residential subdivision. With U.S. data center capacity projected to more than double by 2030, these findings establish data center anthropogenic waste heat as a previously undocumented urban thermal hazard demanding attention from the data center and urban planning communities.

Phoenix↗

Energy Efficient Clothes Dryer with IR Heating and Electrostatic Precipitator

The project goal was to develop a revolutionary energy saving technology for residential clothes drying. The team developed an IR (infrared) heating system and NESP (Nebulizer and Electro-Static Precipitator) for integration into a ventless clothes dryer. The proposed technology addresses two of the major inefficiencies in current electric vented dryers by providing effective energy transfer for the removal of the water and recapture of the vapor latent heat. The IR heaters operating in the mid wave (2.5-10um) are very efficient as they target the 3-micron peak absorption of the water molecule. This allows direct energy absorption, unlike conventional element heaters where heat is transferred by convection. The low power NESP removes water vapor from the exhausted stream and recaptures the latent heat in the ESP (Electro-Static Precipitator) exchanger section. This allows the warm dry air to be recirculated back into the drum for additional efficiency savings. The remaining majority of the dryer hardware stays the same. Summing the efficiency gain from the two subcomponents we anticipated the EF (Efficiency Factor) to exceed the goal of 4.04. EF is obtained by dividing the weight (lbs) of water removed by the energy (kWhr) used, where the test load size is 8.45 lbs of bone dry clothing wetted to 57.5% or 4.8lbs of water, and dried to a remaining moisture content of 2.5-5%. Additional benefits include not having to recondition (heat or cool) the large amounts of make-up air to replace the air exhausted by a vented dryer. It was anticipated that the NESP/heat exchanger would be the most challenging and highest risk element in the program. Therefore, the team focused their efforts during Phase 1 of the program on the design, construction, testing, and optimization of the NESP/heat exchanger. At the end Phase 1, the team compared the performance of the NESP/heat exchanger with the system level requirements and made a Go/No-Go decision on proceeding with the second portion of the program. Phase 2 of the program was structured to develop the IR heating system and then integrate it and the NESP/heat exchanger into a residential clothes dryer prototype for final testing. The proposed technology utilizes heat recovery which is known to have the biggest impact on dryer efficiency. The two current mainstream recovery approaches are air to air exchangers and heat pump condenser systems. Air to air exchanges can be very efficient but require large surface areas which are prone to fouling from uncaptured lint. Dryers based on heat pump condenser recovery systems have shown efficiency improvements of 20–60% and are commercially available. The issue with a heat pump condenser approach is the added cost, as typical prices are twice that of standard vented dryers and they are only available in small to medium capacities. The energy factor (EF) for these systems is 5.50 to 6.88 pounds/kWh compared to conventional dryers at 2.75 to 3.67 pounds/kWh. The efficiency improvements for the proposed technology come from the use of IR heating and the NESP. As the concept is in its infancy, and these improvements were difficult to predict without experimental data, assumptions were made based on available literature. IR radiant drying times, when compared to convection, are typically 30% less. This is a result of the fact that radiant energy heats directly and is absorbed at and below the surface, unlike convection heating, that must conduct the heat through the boundary film of air at the clothes surface and rely on wicking of the moisture to the surface. The second area of improvement comes from the NESP. The NESP operation is as follows: 1. Highly charged, micron sized, droplets of water are injected into the dryer exhaust by the Nebulizer. 2. These charged droplets attract water molecules and continue to grow in size, until losing their charge. During this process, latent heat is rejected back into the air stream. 3. The large droplets enter the ESP, where they are recharged and drawn to the ESP wall, to be extracted at the bottom of the ESP. The warm dry air is then recirculated back into the dryer. The proposed technology, at the time of the proposal submission was estimated to have an EF of 4.79. At program completion we have designed, built, tested, integrated and optimized the proposed technologies into a prototype “high efficiency” residential clothes dryer. Testing of the integrated prototype dryer provided insight into the technical effectiveness and economic feasibility of the proposed technologies. The program has the potential of greatly impacting energy savings. The predicted EF of the proposed technology is 4.79, yielding an energy savings of 42% when compared to conventional electric vented dryers. Given there are approximately 84 million dryers in the US consuming ~64 billion kWh per year, a net savings of 27 billion kWh per year or 0.092 quads could be realized. Since the dryer is not vented, make up air from the room is not needed, adding an additional savings of ~1kWh per load, or 23.8 billion kWh per year. In addition, it is envisioned that the proposed ESP, when successful, would potentially find applications in industrial and residential dehumidification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PERFORMANCE OF SPECTRALLY SELECTIVE COLLECTOR SURFACES IN A SOLAR-DRIVEN CARNOT SPACE-POWER SYSTEM

A study was made of the theoretical performance of spectrally selective surfaces when used as the collectors of solar energy for driving heat engine cycles in space. Selective surfaces were considered for which the-monochromatic emissivity changed abruptly at specific wavelengths between 0.5 and 10 microns. The Carnot cycle was used as the heat engine, and waste heat was rejected from a black radiator. Systems using both focused and unfocused radiation were considered. It was found that spectrally selective surfaces hold considerable promise as collectors of solar energy in unfocused systems. The efficiency for these is several times greater than that obtainable from black or gray collectors. However, this advantage of spectral selectivity diminishes if the sunlight is focused on the collector. In highly focused systems, such as those using parabolic mirrors, black collectors give substantially the same efficiency as the most ideal spectrally selective surface.

SOLAR PROPULSION↗