Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Energy resolved soft x-ray imaging using a charge coupled device camera for long pulse discharges in the Large Helical Device

Energy resolved soft x-ray imaging system using a charge coupled device camera and a multifilter disk has recently been installed to the Large Helical Device for the measurements in the long pulse discharges. Eight images with different cutoff energies are measured sequentially during a single discharge by rotating a filter disk mounting eight beryllium filters with different thicknesses. A tangential line-integrated profile for a specific photon energy range can be obtained by taking intensity difference between two images measured with a filter pair of adjacent thicknesses. The typical photon energy corresponding to each difference ranges from 1.9 to 4.8 keV with the bandwidth of 2-3 keV. In the initial results, the difference in the line-integrated soft x-ray profile by the energy range has been clearly observed. This diagnostic method can possibly be applied to the observation of the dependence of two dimensional soft x-ray profile on photon energy range especially if local non-Maxwellian component appears in electron energy distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast ion measurement using a hybrid directional probe in the large helical device

A hybrid directional probe was newly installed in the large helical device for fast ion measurement. The collector of the probe mounts a thermocouple to estimate local power flux and can be also utilized as a collector of a conventional Langmuir probe; therefore, the hybrid directional probe can simultaneously measure both local power density flux and current flux at the same collector surface. The concept and design of the hybrid directional probe, the calibration of the power density measurement, and preliminary result of the fast ion measurement are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma-enabled growth of ultralong straight, helical, and branched silica photonic nanowires

This article reports on the low-temperature inductively coupled plasma-enabled synthesis of ultralong (up to several millimeters in length) SiO{sub 2} nanowires, which were otherwise impossible to synthesize without the presence of a plasma. Depending on the process conditions, the nanowires feature straight, helical, or branched morphologies. The nanowires are amorphous, with a near-stoichiometric elemental composition ([O]/[Si]=2.09) and are very uniform throughout their length. The role of the ionized gas environment is discussed and the growth mechanism is proposed. These nanowires are particularly promising for nanophotonic applications where long-distance and channelled light transmission and polarization control are required.

36 MATERIALS SCIENCE↗

Magnetic field fluctuation measurement with a heavy ion beam probe in the Large Helical Device

The measurements of magnetic field fluctuation with a heavy ion beam probe (HIBP) in the Large Helical Device (LHD) are considered in this article. Measured value reflects not only the fluctuation at the observation point (sample volume) but also the fluctuation on the beam path. These effects (called as the path integral effects) are considered and calculated for variations of fluctuations in LHD. The distortion of the measured profile by the path integral effect is not significant at the peak of the fluctuation amplitude. In contrast, in the region far from the peak, phony signals due to path integral effects are observed. Finally, the resolution of magnetic field fluctuation measurements with our HIBP system is estimated. Estimated results show that the magnitude of 4.1x10{sup -5} T can be measured with our system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ion charge exchange spectroscopy measurement using a radially injected neutral beam on the large helical device

An experimental technique to investigate fast ion confinement based on charge exchange spectroscopy of H{sub {alpha}}-light was applied to evaluate the confinement property of perpendicular fast ions in large helical device (LHD). Sensitivities of the H{sub {alpha}} spectra to the pitch angles of injected neutral beams (NBs) and these to the angle between the sight line of the measurement and NB injection path are examined. The energy dependence of the charge exchange cross section significantly affects the observed spectra since the driving NB is injected perpendicular to the magnetic field lines in the geometry of LHD. The measured spectra are compared to the spectra of GNET simulation results and the simulated spectra agreed well with the experimental measurement when we take into account the contribution of halo neutrals. Although it is difficult to obtain the fast ion distribution functions directly, this technique provides useful experimental data in benchmarking simulation codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of electrostatic potential fluctuation using heavy ion beam probe in large helical device

Heavy ion beam probe (HIBP) for large helical device (LHD) has been improved to measure the potential fluctuation in high-temperature plasmas. The spatial resolution is improved to about 10 mm by controlling the focus of a probe beam. The HIBP is applied to measure the potential fluctuation in plasmas where the rotational transform is controlled by electron cyclotron current drive. The fluctuations whose frequencies change with the time constant of a few hundreds of milliseconds and that with a constant frequency are observed. The characteristics of the latter fluctuation are similar to those of the geodesic acoustic mode oscillation. The spatial profiles of the fluctuations are also obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pellet charge exchange helium measurement using neutral particle analyzer in large helical device

It is very important to investigate the confinement of {alpha} particles, which will be produced by nuclear reactions in ITER and fusion reactors. The pellet charge exchange (PCX) measurement is one of the most powerful methods because it can directly provide the profile of the {alpha} particle energy spectra in a plasma. In the large helical device, PCX using tracer encapsulated solid pellet (TESPEL) has been tried in many hydrogen and helium plasmas, including helium accelerated by using the cyclotron resonance heating. In the PCX, we use the compact neutral particle analyzer without simultaneous mass separation ability. The helium particle measurement can be achieved by the application of voltage in the condenser plate. The scattering of hydrogen particle is carefully considered during the estimation of the helium amount. The radial helium profiles can also be obtained by comparing four TESPEL injection shots with/without higher harmonic fast wave heating and at applied plate voltages for He or H, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of collective Thomson scattering system using 77 GHz gyrotron for bulk and tail ion diagnostics in the large helical device

Collective Thomson scattering (CTS) system is expected to be a strong diagnostic tool for measuring thermal and fast ion distribution function at a local point inside plasmas. The electron cyclotron resonance heating system using a gyrotron at the frequency range of 77 GHz has been installed at the large helical device (LHD). The feasibility of CTS system using the 77 GHz gyrotron is assessed in terms of scattering spectrum and a background noise of the electron cyclotron emission, which affect the signal to noise ratio, with the realistic plasma parameters and incident port locations of LHD. Based on the calculated scattering spectra for bulk and tail fast ion diagnostics, the scattering radiation receiver system with gyrotron frequency feedback circuit is proposed to avoid the frequency chirping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of spatial structure of plasma potential and density fluctuations by multichannel heavy ion beam probe on large helical device

Heavy ion beam probe (HIBP) on large helical device is currently equipped with three channel detectors, which can observe three spatial points simultaneously inside the plasma with resolution of {approx}10 mm. The beam trajectories and observation point location are calculated numerically and optimized allowing for the identification of the mode structure in multichannel (up to 9) HIBP measurements. The calculations show that the radial and poloidal wavenumbers can be identified by proper changing and choosing of the beam energy and trajectory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Instability of wave modes in a free-electron laser with a helical wiggler and ion-channel guiding

The dispersion relation for a free-electron laser (FEL) with a one-dimensional helical wiggler and an ion channel, in the collective regime, is found with all relativistic effects on the space-charge wave and radiation included. This dispersion relation is solved numerically to study the unstable interaction among all wave modes. In group I orbits, coupling between the positive-energy space-charge wave and the left circularly polarized electromagnetic wave is found. This instability and the coupling between the negative and positive-energy space-charge wave are found in the group II orbits in the negative mass regime. In group II orbits, there is a coupling between the right and left circularly polarized electromagnetic waves, in the positive mass regime. These instabilities are found to be distinct from the main FEL resonance. Contrary to the main FEL resonance, the additional instabilities have a nonrelativistic nature and are made of strongly coupled modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of impurity screening in the edge ergodic layer of the Large Helical Device using carbon emissions of CIII to CVI

Four resonance transitions of CIII (977.03 A:2s{sup 2} {sup 1}S{sub 0}-2s2p {sup 1}P{sub 1}), CIV (1550 A:2s {sup 2}S-2p {sup 2}P), CV (40.27 A:1s{sup 2} {sup 1}S{sub 0}-1s2p {sup 1}P{sub 1}), and CVI (33.73 A:1s {sup 2}S-2p {sup 2}P) have been observed in vacuum ultraviolet and extreme ultraviolet regions to study the edge carbon impurity transport in the Large Helical Device ergodic layer. Here, CIII and CIV indicate the carbon influx at the outside boundary of the ergodic layer and CV and CVI indicate the ions in higher ionization stages, which have already experienced the transport in the ergodic layer. The intensity ratio of CV+CVI to CIII+CIV, therefore, represents the degree of impurity screening, which has been analyzed with different edge plasma parameters and ergodic magnetic field structures. The ratio decreases by two orders of magnitude with an increase in electron density n{sub e} in the range of 1-8x10{sup 19} m{sup -3}. The CV and CVI emissions tend to decrease with n{sub e}, whereas the CIII and CIV emissions monotonically increase with n{sub e}. The result suggests an enhancement of the impurity screening in the higher n{sub e} range due to the increasing ion-impurity collision frequency ({nu}{sub {zeta}}{sub i}{identical_to}1/{tau}{sub s}=3.4x10{sup 4} s{sup -1} at n{sub e}=2x10{sup 19} m{sup -3} and 1.0x10{sup 5} s{sup -1} at 6x10{sup 19} m{sup -3} for CV). The friction force parallel to the magnetic fields plays an important role in the edge impurity transport within the ergodic layer. When the ergodic layer structure is thicker, the ratio systematically decreases mainly due to a reduction in CV+CVI emissions. The ratio is also studied by changing the radial position of an externally supplied m/n=1/1 island. When the island is positioned in the ergodic layer, the ratio indicates a remarkable change, i.e., reduction in CV+CVI and increase in CIII+CIV. These experiments demonstrate that the modification of the ergodic magnetic field structure makes a clear change to the edge impurity transport. When the background ion species is changed from hydrogen to helium, the ratio is clearly reduced, at least at n{sub e}{<=}4x10{sup 19} m{sup -3}, suggesting the enhancement of the impurity screening effect due to the increased collisionality. Finally, the experimental result is simulated using three-dimensional edge transport code of EMC3-EIRENE. The density dependence of the carbon ratio can be well reproduced with a simulation code suggesting that impurity screening is induced in the ergodic magnetic field layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of an impurity hole in a plasma with an ion internal transport barrier in the Large Helical Device

Extremely hollow profiles of impurities (denoted as 'impurity hole') are observed in the plasma with a steep gradient of the ion temperature after the formation of an internal transport barrier (ITB) in the ion temperature transport in the Large Helical Device [A. Iiyoshi et al., Nucl. Fusion 39, 1245 (1999)]. The radial profile of carbon becomes hollow during the ITB phase and the central carbon density keeps dropping and reaches 0.1%-0.3% of plasma density at the end of the ion ITB phase. The diffusion coefficient and the convective velocity of impurities are evaluated from the time evolution of carbon profiles assuming the diffusion and the convection velocity are constant in time after the formation of the ITB. The transport analysis gives a low diffusion of 0.1-0.2 m{sup 2}/s and the outward convection velocity of {approx}1 m/s at half of the minor radius, which is in contrast to the tendency in tokamak plasmas for the impurity density to increase due to an inward convection and low diffusion in the ITB region. The outward convection is considered to be driven by turbulence because the sign of the convection velocity contradicts the neoclassical theory where a negative electric field and an inward convection are predicted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Progress in the Negative-Ion-Based Neutral Beam Injectors in Large Helical Device

Negative-ion-based neutral beam injection (negative-NBI) system has been operated for 10 years in Large Helical Device (LHD). The injection power has been increased year by year, according to the improvement of the negative ion sources. Up to now, every injector achieves the designed injection energy and power of 180 keV-5 MW with hydrogen beams, and the total injection power exceeds 16 MW with three injectors. In the multi-round aperture grounded grid (GG), the diameter of a round aperture has been enlarged for higher GG transparency. Then, the GG heat load is reduced, as well as in the multi-slotted GG, and the voltage holding ability in the beam acceleration was improved. As a result, the beam energy is raised and the injection power is increased. To improve the anisotropic property of the beamlet convergence condition between the perpendicular and the parallel directions to the slots in the multi-slotted GG, a round-shape aperture of the steering grid (SG) has been changed to a racetrack shape. As a result, the difference of the beamlet conversion condition is much mitigated, and the injection efficiency (port-transmission efficiency) is improved, leading to 188 keV-6.4 MW injection. The Cs consumption is observed to be proportional to the tungsten evaporation from filaments. The Cs behavior is investigated with optical emission spectroscopy. During the beam extraction, the Cs recycling is dominated by Cs on the backplate, which is evaporated into the plasma by the backstreaming positive ions, and the wall surfaces should be loss regions for the supplied Cs.

43 PARTICLE ACCELERATORS↗

Edge turbulence measurements in electron-heated Helically Symmetric Experiment plasmas

This paper presents edge measurements utilizing Langmuir probes to characterize plasma turbulence in the Helically Symmetric Experiment (HSX) [F. S. B. Anderson et al., Fusion Technol. 27, 273 (1995)]. Normalized density and potential fluctuations exhibit strong intensities but are comparable to mixing length estimates using measured correlation lengths. The correlation lengths are isotropic with respect to radial and poloidal directions and follow local (gyro-Bohm) drift wave expectations. These observations are common to measurements in both the optimized quasihelically symmetric (QHS) configuration, as well as a configuration where the symmetry is degraded intentionally. The resulting turbulent particle flux in higher density QHS discharges is in good quantitative agreement with transport analysis using three-dimensional neutral gas simulations. The measured turbulence characteristics are compared to a quasilinear trapped electron mode (TEM) drift wave model [H. Nordman, J. Weiland, and A. Jarmen, Nucl. Fusion 30, 983 (1990)] that has been used to predict the anomalous transport in HSX. While quantitative differences exist (factors of 2-3), there is a general consistency between the turbulence measurements and the TEM drift wave model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Excitation of stable Alfven eigenmodes by application of alternating magnetic field perturbations in the Compact Helical System

Stable toroidicity-induced Alfven eigenmodes (TAEs) with low toroidal mode number (n=1 and n=2) were excited by application of alternating magnetic field perturbations generated with a set of electrodes inserted into the edge region of neutral beam injection heated plasmas on the Compact Helical System [K. Nishimura, K. Matsuoka, M. Fujiwara et al., Fusion Technol. 17, 86 (1990)]. The gap locations of TAEs excited by the electrodes are in the plasma peripheral region of {rho}>0.7 ({rho} is the normalized minor radius) where energetic ion drive is negligibly small, while some AEs are excited by energetic ions in the plasma core region of {rho}<0.4. The damping rate of these stable TAEs derived from plasma responses to applied perturbations is fairly large, that is, {approx}9% to {approx}12% of the angular eigenfrequency. This large damping rate is thought to be dominantly caused by continuum damping and radiative damping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatiotemporal dynamics and transport reduction in helical magnetic configuration

Effects of multihelicity confinement magnetic fields on turbulent transport and zonal flows are investigated by means of spatiotemporal analysis of gyrokinetic Vlasov simulation results for the ion temperature gradient turbulence, where the standard and the inward-shifted configurations of the Large Helical Device are considered. The analysis of simulation results demonstrates that fluctuations of electrostatic potential for zonal flows exhibit spatiotemporal chaos in both configurations. However, the intensity of chaos found is considerably decreased in the inward-shifted configuration consistent with improved confinement. Enhanced zonal flow generation in the inward shifted case is accompanied by transport reduction which may be a direct consequence of chaos suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lasing conditions of a free electron laser with helical wiggler

In this investigation the problem of the lasing of a free electron laser with magnetostatic helical wiggler is studied. In the linear approximation, the threshold conditions of the lasing for Raman and Compton regimes under excitation of the forward and backward electromagnetic waves are achieved. In the various physical situations, the variation in the minimum length of the resonator with energy and density of electron beam and with the reflection coefficients of resonator's mirrors is investigated.

43 PARTICLE ACCELERATORS↗

Characteristics of 80 keV positive ion source for Large Helical Device

An additional beamline, BL5, equipped with four positive ion sources will be installed on Large Helical Device (LHD) in 2010. The performance of an ion source which generates 80 keV deuterium and 60 keV hydrogen beams was investigated. The structure of the ion source is based on that of a BL4 ion source on LHD. The main differences between the ion sources for the BL4 and BL5 are the acceleration voltages and the materials of plasma electrodes: copper and molybdenum, respectively. The molybdenum plasma electrode for BL5 has better performance than the copper plasma electrode of BL4. The integrated performance of the ion source for BL5 reached a value equivalent to {approx}58 A in the beam current of hydrogen positive ion at 60 keV in the beam energy.

43 PARTICLE ACCELERATORS↗