Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fuel Cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3: Full-scale power plant development

The development of a commercially viable and cost-effective phospheric acid fuel cell powered on-site integrated energy system (OS/IES) is described. The fuel cell offers energy efficients in the range of 35-40% of the higher heating value of available fuels in the form of electrical energy. In addition, by utilizing the thermal energy generated for heating, ventilating and air-conditioning (HVAC), a fuel cell OS/IES could provide total energy efficiencies in the neighborhood of 80%. Also, the Engelhard fuel cell OS/IES offers the important incentive of replacing imported oil with domestically produced methanol, including coal-derived methanol.

Source record↗

Quantifying the electrochemical active site density of precious metal-free catalysts in situ in fuel cells

We report advances in the development of precious-group metal-free (PGM-free) catalysts for the oxygen reduction reaction (ORR) in fuel cell cathodes have produced active catalysts that reduce the performance gap to the incumbent Pt-based materials. However, utilization of state-of-the-art PGM-free catalysts for commercial applications is currently impeded by their relatively low durability. Methods designed to study catalyst degradation in the operation of fuel cells are therefore critical for understanding durability issues and, ultimately, their solutions. Here we report the use of Fourier-transform alternating current voltammetry as an electrochemical method for accurate quantification of the electrochemically active site density of PGM-free cathode catalysts, and to follow their degradation in situ during the operation of polymer electrolyte fuel cells. Using this method, we were able to quantify the electrochemical active site density, which will enable the elucidation of degradation mechanisms of PGM-free ORR catalysts in situ in fuel cells.

25 ENERGY STORAGE↗

Experimental and Theoretical Analysis of Ink Dispersion Stability for Polymer Electrolyte Fuel Cell Applications

The aggregate size in fuel cell catalyst inks depends on the type of dispersion medium, particle concentration, and addition of stabilizing agents. In this work, ink stability and particle size of carbon black and carbon black/Nafion dispersions in four non-aqueous media, viz., methanol, ethanol, isopropanol and ethyl acetate are studied. Based on visual inspection, isopropanol is found to be the best medium for dispersion of carbon black inks. To rationalize this observation, a semi-empirical model based on diffusion-limited aggregation was developed to evaluate the rate of particle aggregation and predict the ink stability time for each dispersion medium. The proposed model supports the experimental observation by qualitatively predicting the same relationship between carbon stability and the dispersion media. The model also showed that the dielectric constant of the dispersion medium and the particle zeta potential are primarily responsible for the ink stability. Particle size for the different inks was determined by dynamic light scattering with and without dilution. Experimental results show that Nafion is a strong stabilizing agent, increasing the ink stability and decreasing the particle size of carbon aggregates. The beneficial effects of Nafion are independent of its concentration and are observed even at Nafion volume fractions of 10 wt%. The interaction energy is found to be a strong function of the surface potential for the dispersion medium with a higher dielectric constant.

25 ENERGY STORAGE↗

Stable, high-performing bifunctional electrodes for anion exchange membrane-based unitized regenerative fuel cells

Anion exchange membrane unitized regenerative fuel cells (AEM-URFCs) are a promising technology for energy storage and electricity production; however, their efficiency is limited by the kinetics of the bifunctional oxygen electrode (BOE) where the oxygen evolution reaction (OER) and oxygen reduction reaction (ORR) occur. A particular concern when designing the BOE is that the OER and ORR have differing catalytic requirements, which make it challenging to develop effective bifunctional electrocatalysts with single active sites. In this study, we focus on advancing the BOE performance using Pt-IrO x and Pt-NiCoO x electrocatalysts. Here, single-layer and dual-layer Pt-IrO x BOEs were made, with the dual-layer electrode leading to improved performance due to efficient catalyst utilization in both modes. Using the dual-layer oxygen electrode paired with a PtRu/C hydrogen electrode, a round trip efficiency (RTE) as high as 50% (62 %iR-free) was achieved at 500 mA/cm 2 and operation for more than 24 h, which included five one-hour-long H 2 generation and consumption cycles followed by one eight-hour-long cycle. To the best of our knowledge, this is the highest performance for AEM-URFCs reported to date. Lastly, the approach is extended to electrodes with a Pt loading of 0.5 mg/cm 2 and the IrO x substituted by NiCoO x .

25 ENERGY STORAGE↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

Enhanced Performance of non-PGM Catalysts in Air Operated PEM-Fuel Cells

Here a non-platinum group metal (non-PGM) oxygen reduction catalyst was prepared from “support-free” zeolitic imidazolate framework (ZIF) precursor and tested in the proton exchange membrane fuel cell with air as the cathode feed. The iron nitrogen and carbon composite (FeeNeC) based catalyst has high specific surface area decorated uniformly with active sites, which redefines the triple phase boundary (TPB) and requires re-optimization of the cathodic membrane electrode fabrication to ensure efficient mass and charge transports to the catalyst surface. This study reports an effort in optimizing catalytic ink formulation for the membrane electrode preparation and its impact to the fuel cell performance under air. Through optimization, the fuel cell areal current density as high as 115.2 mA/cm 2 at 0.8 V or 147.6 mA/cm 2 at 0.8 V iR-free has been achieved under one bar air. We also investigated impacts on fuel cell internal impedance and the water formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Forming Limits of Thin Ferritic Stainless Steel for Fuel Cell Application

To lower the cost of fuel cell bipolar plate (BPP), less expensive ferritic stainless steel (FSS) BPP substrate materials are investigated. A series of tensile tests and multistage microchannel-forming tests were conducted on 85-µm-thick ferritic stainless steel foils, 439L, 444, and Chromeshield® 22, to understand the effect of the forming temperatures, tooling geometry, and processes on their formability. Three microchannel-forming processes were conducted, which are 1-Hit (single-stage forming), 2-Hit (two-stage forming) with 50% preform, and 2-Hit with 80% preform. FLC o s at various microchannel-forming conditions were obtained to address the formability of the ferritic stainless steel foils under plane strain conditions. It has been found that the larger the microchannel radius, the better the formability, two-stage forming is superior to the single-stage process, and a larger draw percentage in preform (stage I) leads to a higher FLC o or better formability. It has also been found from tensile tests that the thermal effect (higher temperature) has a negative impact on the failure strains. A similar phenomenon was also observed through channel-forming tests conducted at room temperature, 100 °C, and 200 °C.

08 HYDROGEN↗

Active and Durable PGM-free Cathodic Electrocatalysts for Fuel Cell Application

Platinum Group Metal-free (PGM-free) Oxygen Reduction Reaction (ORR) electrocatalysts possess high intrinsic activity measured by a Rotating Disk Electrode (RDE) method. However, under fuel cell operating conditions, PGM-free ORR electrocatalysts have underperformed compared to platinum catalysts. PGM-free ORR electrocatalyst’s fuel cell performance can be improved by designing and optimizing the cathodic catalyst layer (CL) and Membrane Electrode Assembly (MEA) construction such that: 1) it efficiently provides oxygen access to ORR active sites (through catalyst morphology control); 2) it removes water from the CL (by tuning the hydrophobicity of the PGM-free catalysts and the catalyst layer structure); and 3) it increases proton conductivity (by homogeneous mixing of catalysts and ionomer). Studying the CL is complex due to the absence of well-established protocols of MEA activation, especially compared to platinum-containing catalysts. PGM-free fuel cell testing protocols would need to optimize potentiostatic vs galvanostatic measurements, scan rates, parameters of Electrochemical Impedance Spectroscopy (EIS) and Beginning of Experiment (BOE) criteria. To make the PGM-free catalyst’s fuel cell performance comparable to platinum, the synergistic effort of materials design, fine tuning of the catalyst layer and comprehensive electrochemical analysis is required.

08 HYDROGEN↗

Fuel Cell Buses in U.S. Transit Fleets: Current Status 2012

This report is the sixth in an annual series of reports that summarize the progress of fuel cell electric bus (FCEB) development in the United States and discuss the achievements and challenges of introducing fuel cell propulsion in transit. The report also provides a snapshot of current FCEB performance results over the last year. There are 25 active FCEBs in demonstrations this year at eight locations.

08 HYDROGEN↗

Michigan Hydrogen and Fuel Cell Electric Vehicle Deployment Plan: H2 FCEV Roadmap 2022

This report describes a roadmap for hydrogen fuel cell electric vehicles in the state of Michigan. This plan provides links to relevant information to assess, plan, and initiate hydrogen and FCEV deployment to help meet the energy, economic, and environmental goals for the State of Michigan. Policies and incentives that support hydrogen and fuel cell technology will increase deployment, thus increasing production and creating jobs throughout the supply chain. As deployment increases, an economy of scale will develop and manufacturing costs will decline, positioning hydrogen and fuel cell technology to compete more effectively in a global market without incentives. Policies and incentives to purchase and support the deployment of FCEVs, FCEBs, and hydrogen refueling can be coordinated regionally to maintain this advanced clean transportation sector as a global exporter for long-term growth and economic development. Overall, the execution of this plan will maintain Michigan's role as a global showcase for regionally manufactured transportation technology while reducing NOx and CO 2 emissions and as new jobs are created for businesses and industry.

08 HYDROGEN↗

Architecture-Based Control of Temperature Gradient-Driven Water Transport in Polymer Electrolyte Fuel Cells

Temperature gradients can move water within the porous media of a polymer electrolyte fuel cell through phase-change-induced (PCI) flow. It is critical to understand PCI flow so that control and distribution of water within a fuel cell can be accomplished. This work investigates the role of architecture, specifically anode land width, on overall cell water content and distribution in the through-plane direction. A specially-designed 4.8 cm 2 fuel cell with precise thermal boundary conditions was imaged with neutrons using two different anode flow field configurations. A new, non-dimensional thermal transport number was developed which quantifies the relative influence of PCI flow on cell water transport. It was found that anode lands larger than the cathode lands cause large thermal gradients that instigate net water flux from the cathode to the anode. An asymmetric configuration with larger anode lands was found to have large changes in water content that were strongly sensitive to cell operating conditions. The thermal transport number developed here enables deduction of the net flux condition based on operating conditions and architecture. This approach enables design of high-performance systems with balanced water management.

25 ENERGY STORAGE↗

Study of Cathode Gas Diffusion Architecture for Improved Oxygen Transport in Hydroxide Exchange Membrane Fuel Cells

The high pH environment in hydroxide exchange membrane fuel cells (HEMFCs) has the potential to reach lower costs than the current proton exchange membrane fuel cells (PEMFCs), the incumbent technology. A significant difference between HEMFCs and PEMFCs is the location of water production within the cell. In PEMFCs, the water is produced on the cathode, limiting oxygen transport. In HEMFCs, the water is produced on the anode where the fuel is pure hydrogen. This allows the cathode to be optimized for oxygen transport without the presence of excess liquid water. Limiting current analysis, a technique previously used in PEMFCs, is adopted in HEMFCs to evaluate the oxygen mass transport resistances for different sections of the cathode. Through elimination of the microporous layer (MPL), gas diffusion layer (GDL), and traditional flow field and using porous nickel foam for gas distribution, the transport resistance at an operating condition of 150 kPa(g) and with the cell temperature at 80 °C was decreased from 112 s m −1 to 48 s m −1 , effectively halved. The optimal configuration for performance was found with Ni foam and a GDL, eliminating the MPL and traditional flow field, which vastly improved oxygen transport while maintaining adequate electrical contact with the cathode catalyst layer.

25 ENERGY STORAGE↗

Hydrogen storage and integrated fuel cell assembly

Hydrogen is stored in materials that absorb and desorb hydrogen with temperature dependent rates. A housing is provided that allows for the storage of one or more types of hydrogen-storage materials in close thermal proximity to a fuel cell stack. This arrangement, which includes alternating fuel cell stack and hydrogen-storage units, allows for close thermal matching of the hydrogen storage material and the fuel cell stack. Also, the present invention allows for tailoring of the hydrogen delivery by mixing different materials in one unit. Thermal insulation alternatively allows for a highly efficient unit. Individual power modules including one fuel cell stack surrounded by a pair of hydrogen-storage units allows for distribution of power throughout a vehicle or other electric power consuming devices.

Gross, Karl J↗

Computationally Assisted Design of Ion-conducting Polymers for Anion Exchange Membrane Fuel Cells (2nd Year Report) [Slides]

Phosphonated polymers have been proposed as proton conductors for fuel cells; however, the anhydride formation of phosphonic acid functional groups lowers proton conductivity and hinders their use in fuel cell applications. We used calculations to support this hypothesis by correlating calculated Gibbs free energies for the formation of the anhydride with pK values of the corresponding acid. The results showed that stronger acids are less likely to form an anhydride even at elevated temperatures and supported the design of a new polymer and the high-temperature proton exchange membrane fuel cell (HT-PEMFC) that outperformed other state-of-the-art HT-PEMFCs.

30 DIRECT ENERGY CONVERSION↗

Evaluation of Metal Halide, Plasma, and LED Lighting Technologies for a Hydrogen Fuel Cell Mobile Light (H 2 LT)

This article reports on the testing and comparison of a prototype hydrogen fuel cell light tower (H2LT) and a conventional diesel-powered metal halide light trailer for use in road maintenance and construction activities. The prototype was originally outfitted with plasma lights and then with light-emitting diode (LED) luminaires. Light output and distribution, lighting energy efficiency (i.e., efficacy), power source thermal efficiency, and fuel costs are compared. The metal halide luminaires have 2.2 and 3.1 times more light output than the plasma and LED luminaires, respectively, but they require more power/lumen to provide that output. The LED luminaires have 1.6 times better light efficacy than either the metal halide or plasma luminaires. The light uniformity ratios produced by the plasma and LED towers are acceptable. The fuel cell thermal efficiency at the power required to operate the plasma lights is 48%, significantly higher than the diesel generator efficiency of 23% when operating the metal halide lights. Due to the increased efficiency of the fuel cell and the LED lighting, the fuel cost per lumen-hour of the H2LT is 62% of the metal halide diesel light tower assuming a kilogram of hydrogen is twice the cost of a gallon of diesel fuel.

30 DIRECT ENERGY CONVERSION↗

Fuel cell on-site integrated energy system parametric analysis of a residential complex

A parametric energy-use analysis was performed for a large apartment complex served by a fuel cell on-site integrated energy system (OS/IES). The variables parameterized include operating characteristics for four phosphoric acid fuel cells, eight OS/IES energy recovery systems, and four climatic locations. The annual fuel consumption for selected parametric combinations are presented and a breakeven economic analysis is presented for one parametric combination. The results show fuel cell electrical efficiency and system component choice have the greatest effect on annual fuel consumption; fuel cell thermal efficiency and geographic location have less of an effect.

Simons, S. N.↗

Effect of Reactant Purity on Proton Exchange Membrane Fuel Cell Performance

NASA has set a goal to return to the Moon and to establish a sustained lunar presence. Many applicable lander and upperstage vehicle concepts utilize cryogenic H2 and O2 propellants. This propellant selection enables appealing potential mission concepts wherein electricity is generated by operating a fuel cell on residual H2 and O2 propellants. This concept depends on the capability of the fuel cell to utilize dry, propellant-grade reactants with concentrations of up to 30 percent He present. This study consists of the evaluation of a 12-cell non-flow-through proton exchange membrane fuel cell stack of 50 sq. cm active area with passive water removal. This stack was supplied with three levels of reactant purity: >99.999, 99.1, and 70 mol%, with the remainder made up of He. The reactant humidity and flow-through rate were also assessed as performance factors, and the fuel stack repeatedly supported a load profile with current densities up to 500 mA/sq. cm (25 A). The fuel cell performed consistently over the course of testing, with cell voltages decreasing approximately 50 mV at the maximum current density when supplied with reactants with 30 percent He present.

electrochemistry↗

Advanced Fuel Cell System Thermal Management for NASA Exploration Missions

The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA exploration program. An analysis of a state-of-the-art fuel cell cooling systems was done to benchmark the portion of a fuel cell system s mass that is dedicated to thermal management. Additional analysis was done to determine the key performance targets of the advanced passive thermal management technology that would substantially reduce fuel cell system mass.

Burke, Kenneth A.↗