Radiation-Hard, High-Bandwidth Optical Fiber Links for Detectors at High Energy Colliders
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A number of optical communication lines are now in use at the Kennedy Space Center (KSC) for the transmission of voice, computer data and video signals. At the present time most of these channels utilize a single carrier wavelength centered near 1300 nm. As a result of previous work the bandwidth capacity of a number of these channels is being increased by transmitting another signal in the 1550 nm region on the same fiber. This is accomplished by means of wavelength division multiplexing (WDM). It is therefore important to understand the bandwidth properties of the installed fiber plant. This work developed new procedures for measuring the bandwidth of fibers in both the 1300nm and 1550nm region. In addition, a preliminary study of fiber links terminating in the Engineering Development Laboratory was completed.
Understanding fracture height growth can be of great significance to optimizing field development and improving recovery. The Hydraulic Fracturing Test Site 2 (HFTS-2) has provided a unique opportunity and an advanced dataset to allow us to observe and understand fracture geometries rigorously. Low frequency distributed acoustic sensing (LF-DAS) data from a vertical well in HFTS-2 showed three key observations: (i) excessive upward height growth (>1000 ft) and limited downward growth of the hydraulic fractures during pumping, (ii) considerable additional upward fracture height growth (~300 ft) after well shut in, and (iii) very complex LF-DAS strain rate patterns for a small fiber-to-stage offset. Advanced geomechanical modeling was performed to simulate the hydraulic fracture propagation and the resulting strain responses in the vertical direction. The modeling results demonstrated asymmetric upward and downward fracture height growths as observed in HFTS-2 with a similar upward height growth rate. Simulated waterfall plots of vertical strain rate showed distinct patterns for different fiber-to-fracture distances. The upward-growing fracture tip can be clearly identified by the interfaces between compressing and extending zones. It was also found that the complex strain rate patterns observed in HFTS-2 for small fiber-stage offsets were not caused by the mechanical layering but possibly result from the simultaneous propagation of multiple hydraulic fractures at different rates. Furthermore, the simulation results improved the understating of the HFTS-2 LF-DAS data and the simulated strain rate patterns could also serve as templates for fracture height interpretation from LF-DAS data in future.
Summary Understanding fracture height growth can be of great significance to optimizing field development and improving recovery. The Hydraulic Fracturing Test Site 2 (HFTS-2) has provided a unique opportunity and an advanced data set to allow us to observe and understand fracture geometries rigorously. Low-frequency distributed acoustic sensing (LF-DAS) data from a vertical well in HFTS-2 showed three key observations: (i) excessive upward height growth (>1,000 ft) and limited downward growth of the hydraulic fractures during pumping, (ii) considerable additional upward fracture height growth (~300 ft) after well shut in, and (iii) very complex LF-DAS strain rate patterns for a small fiber-to-stage offset. Advanced geomechanical modeling was performed to simulate the hydraulic fracture propagation and the resulting strain responses in the vertical direction. The modeling results demonstrated asymmetric upward and downward fracture height growths as observed in HFTS-2 with a similar upward height growth rate. Simulated waterfall plots of vertical strain rate showed distinct patterns for different fiber-to-fracture distances. The upward-growing fracture tip can be clearly identified by the interfaces between compressing and extending zones. It was also found that the complex strain rate patterns observed in HFTS-2 for small fiber-stage offsets were not caused by the mechanical layering but possibly result from the simultaneous propagation of multiple hydraulic fractures at different rates. The simulation results improved the understating of the HFTS-2 LF-DAS data, and the simulated strain rate patterns could also serve as templates for fracture height interpretation from LF-DAS data in future.
Disclosed is a method and the resulting product thereof comprising a solid light-conducting fiber with a point of attachment and having a textured surface site consisting a textured distal end prepared by being placed in a vacuum and then subjected to directed hyperthermal beams comprising oxygen ions or atoms. The textured distal end comprises cones or pillars that are spaced upon from each other by less than 1 micron and are extremely suitable to prevent cellular components of blood from entering the valleys between the cones or pillars so as to effectively separate the cellular components in the blood from interfering with optical sensing of the glucose concentration for diabetic patients.
In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.
Bromothymol Blue (BT)/Bromocresol Green (BG) mixture (1/1) in hydrogel (l/l), produces a blue-green indicator for HZ and/or NO2. The stability over a two months period of this BT/BG (1/1) indicator solution was tested and no evidence of performance deterioration was detected. A dual HZ/NO2 prototype sensor utilizing an acid-base indicator was previously constructed. A monitor and control circuit are also designed, built d tested during the course of this project. The circuit is controlled with Motorola MC68HC II microcontroller evaluation board to monitor the voltage level out of the photodetector. Low-pass filter and amplifier are used to interface the sensor's small voltage with the microcontroller's AD input. The sensor, interface circuit and the microcontroller board are then all placed in one unit and powered with a single power supply. The unit is then tested several times and the response was consistent and proved the feasibility of dual "J@ leak detection. Other sensor types, suitable for silica glass fiber, smaller in size, more rugged and suitable for use on board of the Space Shuttle and missile canisters, are then proposed.
In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Previous tests using metal oxide-based coatings (TiO2) provided strong responses at elevated temperatures and moderate pressure stability but provided poor differentiation between acidic and alkaline solutions. Building off the pH responsiveness of the TiO2 surface and known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. As the polymer itself is highly water soluble and easily removed by aqueous solutions, the sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1,000 psi) and temperatures (80 °C).
Sodium fast reactors (SFR) are poised to be a leading candidate for the next generation of commercial nuclear reactor deployment. Companies are commissioning designs for SFR increasing the need for experimental and computational analysis to improve the economics and safety of these reactors. Analysis of SFR behavior during reactor transients directly informs the understanding of reactor safety. Particularly, investigating the thermal transients associated with the reactor loss of flow transient allows for informed design decisions to be made regarding reactor safety. During loss of flow transients the flow rate of the coolant is significantly reduced, but not necessarily stopped. The reduction in flow rate results in coolant temperatures exiting the reactor core that can be drastically different than the coolant in upper pool. When these different temperature fluids interact, thermally stratified layers can form causing cyclic thermal fatigue on the reactor vessel potentially leading to pre-material failure. Past experimental studies have lacked high resolution temperature measurements. This research focuses on demonstrating the reliability of novel techniques for acquiring high resolution temperature measurements in a scaled liquid sodium facility. Tests are conducted that simulate postulated loss of flow transients and provide unprecedented spatial temperature distribution measurements.
Not Available
Not Available
Not provided.
Not Available
Not Available
Not Available
Not Available