Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

An Evaluation of Departmental Radiation Oncology Incident Reports: Anticipating a National Reporting System

Purpose: Systems to ensure patient safety are of critical importance. The electronic incident reporting systems (IRS) of 2 large academic radiation oncology departments were evaluated for events that may be suitable for submission to a national reporting system (NRS). Methods and Materials: All events recorded in the combined IRS were evaluated from 2007 through 2010. Incidents were graded for potential severity using the validated French Nuclear Safety Authority (ASN) 5-point scale. These incidents were categorized into 7 groups: (1) human error, (2) software error, (3) hardware error, (4) error in communication between 2 humans, (5) error at the human-software interface, (6) error at the software-hardware interface, and (7) error at the human-hardware interface. Results: Between the 2 systems, 4407 incidents were reported. Of these events, 1507 (34%) were considered to have the potential for clinical consequences. Of these 1507 events, 149 (10%) were rated as having a potential severity of ≥2. Of these 149 events, the committee determined that 79 (53%) of these events would be submittable to a NRS of which the majority was related to human error or to the human-software interface. Conclusions: A significant number of incidents were identified in this analysis. The majority of events in this study were related to human error and to the human-software interface, further supporting the need for a NRS to facilitate field-wide learning and system improvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Windowed Fourier transform and cross-correlation algorithms for molecular tagging velocimetry

In this study, simulated and experimental molecular tagging velocimetry (MTV) images have been analyzed with a technique commonly used to process grid images on surfaces, the windowed Fourier transform with local spectrum analysis (WFT-LSA). A systematic synthetic image study of the modulation transfer function (MTF) and error tendencies of the WFT-LSA was performed and compared with a PIV-style cross-correlation algorithm to see if advanced strategies such as iterative image deformation can improve analysis of gridded images with high noise levels. Testing of single-pass algorithms showed that in typical MTV images, the WFT-LSA yields significantly lower bias errors than cross-correlation (CC) at displacements greater than 1 pixel but slightly higher random error at all displacements and image conditions. Analysis of the MTF shows that CC provided better resolution of spatial fluctuations than the WFT-LSA in many combinations of grid size and interrogation window. Tests of image deformation algorithms showed that the gap in performance between CC and WFT-LSA is maintained even as both methods improve. Additionally, WFT-LSA and CC methods are applied to real MTV experiments in high-speed gas jet flows. A preliminary analysis of phosphorescence lifetime provided by acetone vapor excited at 266 nm is used for assessing the required gas speeds for making MTV application feasible. The application of WFT-LSA to real MTV images demonstrates the ability of the algorithm to handle further real-world effects that could not be considered in the synthetic image analysis, like reduced signal-to-noise ratio and non-uniform intensity of the tagging grid across the image introduced by the actual laser beam energy distribution. With experimental images, CC is more accurate with shear flows but less robust to high noise levels than WFT-LSA, as predicted by the synthetic image analysis.

42 ENGINEERING↗

Fifty Years of THERP and Human Reliability Analysis

In 1962 at a Human Factors Society symposium, Alan Swain presented a paper introducing a Technique for Human Error Rate Prediction (THERP). This was followed in 1963 by a Sandia Laboratories monograph outlining basic human error quantification using THERP and, in 1964, by a special journal edition of Human Factors on quantification of human performance. Throughout the 1960s, Swain and his colleagues focused on collecting human performance data for the Sandia Human Error Rate Bank (SHERB), primarily in connection with supporting the reliability of nuclear weapons assembly in the US. In 1969, Swain met with Jens Rasmussen of Risø National Laboratory and discussed the applicability of THERP to nuclear power applications. By 1975, in WASH-1400, Swain had articulated the use of THERP for nuclear power applications, and the approach was finalized in the watershed publication of the NUREG/CR-1278 in 1983. THERP is now 50 years old, and remains the most well known and most widely used HRA method. In this paper, the author discusses the history of THERP, based on published reports and personal communication and interviews with Swain. The author also outlines the significance of THERP. The foundations of human reliability analysis are found in THERP: human failure events, task analysis, performance shaping factors, human error probabilities, dependence, event trees, recovery, and pre- and post-initiating events were all introduced in THERP. While THERP is not without its detractors, and it is showing signs of its age in the face of newer technological applications, the longevity of THERP is a testament of its tremendous significance. THERP started the field of human reliability analysis. This paper concludes with a discussion of THERP in the context of newer methods, which can be seen as extensions of or departures from Swain’s pioneering work.

99 GENERAL AND MISCELLANEOUS↗

Spine Stereotactic Body Radiotherapy Utilizing Cone-Beam CT Image-Guidance With a Robotic Couch: Intrafraction Motion Analysis Accounting for all Six Degrees of Freedom

Purpose: To evaluate the residual setup error and intrafraction motion following kilovoltage cone-beam CT (CBCT) image guidance, for immobilized spine stereotactic body radiotherapy (SBRT) patients, with positioning corrected for in all six degrees of freedom. Methods and Materials: Analysis is based on 42 consecutive patients (48 thoracic and/or lumbar metastases) treated with a total of 106 fractions and 307 image registrations. Following initial setup, a CBCT was acquired for patient alignment and a pretreatment CBCT taken to verify shifts and determine the residual setup error, followed by a midtreatment and posttreatment CBCT image. For 13 single-fraction SBRT patients, two midtreatment CBCT images were obtained. Initially, a 1.5-mm and 1 Degree-Sign tolerance was used to reposition the patient following couch shifts which was subsequently reduced to 1 mm and 1 Degree-Sign degree after the first 10 patients. Results: Small positioning errors after the initial CBCT setup were observed, with 90% occurring within 1 mm and 97% within 1 Degree-Sign . In analyzing the impact of the time interval for verification imaging (10 {+-} 3 min) and subsequent image acquisitions (17 {+-} 4 min), the residual setup error was not significantly different (p > 0.05). A significant difference (p = 0.04) in the average three-dimensional intrafraction positional deviations favoring a more strict tolerance in translation (1 mm vs. 1.5 mm) was observed. The absolute intrafraction motion averaged over all patients and all directions along x, y, and z axis ({+-} SD) were 0.7 {+-} 0.5 mm and 0.5 {+-} 0.4 mm for the 1.5 mm and 1 mm tolerance, respectively. Based on a 1-mm and 1 Degree-Sign correction threshold, the target was localized to within 1.2 mm and 0.9 Degree-Sign with 95% confidence. Conclusion: Near-rigid body immobilization, intrafraction CBCT imaging approximately every 15-20 min, and strict repositioning thresholds in six degrees of freedom yields minimal intrafraction motion allowing for safe spine SBRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of a Chemical Index to Aerosol Mass Spectrometry: Delta Plots and Functional Group Distributions

A better understanding of the chemical properties of organic aerosol (OA) particles will improve our ability to characterize their sources and predict their lifetime. The high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA in real time using thermal vaporization followed by electron ionization (EI). EI creates fragment ions that can be assigned to functional groups using delta analysis, a method of classifying mass spectra according to the presence of different chemically related ion series. In this study, we demonstrate the application of delta analysis to characterize molecular structures using a new visualization method. We also use delta analysis to quantify the functional group distribution with an average absolute error of ∼5–6% for individual standard molecules, comparable to the error observed for OA mixtures from biomass and coal combustion fit with Fourier transform infrared spectroscopy. Finally, we apply delta functional group analysis to AMS positive matrix factorization (PMF) factors across seven different field campaigns and find a similar composition across the more oxidized factors with about 55% acid and 26% alcohol groups. The analysis method described here can be applied to any HR-ToF-AMS data set to provide quantitative relative functional group distributions for OA mixtures.

aerosol↗

Photometric redshift uncertainties in weak gravitational lensing shear analysis: models and marginalization

ABSTRACT Recovering credible cosmological parameter constraints in a weak lensing shear analysis requires an accurate model that can be used to marginalize over nuisance parameters describing potential sources of systematic uncertainty, such as the uncertainties on the sample redshift distribution n(z). Due to the challenge of running Markov chain Monte Carlo (MCMC) in the high-dimensional parameter spaces in which the n(z) uncertainties may be parametrized, it is common practice to simplify the n(z) parametrization or combine MCMC chains that each have a fixed n(z) resampled from the n(z) uncertainties. In this work, we propose a statistically principled Bayesian resampling approach for marginalizing over the n(z) uncertainty using multiple MCMC chains. We self-consistently compare the new method to existing ones from the literature in the context of a forecasted cosmic shear analysis for the HSC three-year shape catalogue, and find that these methods recover statistically consistent error bars for the cosmological parameter constraints for predicted HSC three-year analysis, implying that using the most computationally efficient of the approaches is appropriate. However, we find that for data sets with the constraining power of the full HSC survey data set (and, by implication, those upcoming surveys with even tighter constraints), the choice of method for marginalizing over n(z) uncertainty among the several methods from the literature may modify the 1σ uncertainties on Ωm–S8 constraints by ∼4 per cent, and a careful model selection is needed to ensure credible parameter intervals.

Zhang, Tianqing (ORCID:000000025596198X)↗

Toward Quantity-of-Interest Preserving Lossy Compression for Scientific Data

Today's scientific simulations and instruments are producing a large amount of data, leading to difficulties in storing, transmitting, and analyzing these data. While error-controlled lossy compressors are effective in significantly reducing data volumes and efficiently developing databases for multiple scientific applications, they mainly support error controls on raw data, which leaves a significant gap between the data and user's downstream analysis. This may cause unqualified uncertainties in the outcomes of the analysis, a.k.a quantities of interest (QoIs), which are the major concerns of users in adopting lossy compression in practice. In this paper, we propose rigorous mathematical theories to preserve four families of QoIs that are widely used in scientific analysis during lossy compression along with practical implementations. Specifically, we first develop the error control theory for univariate QoIs which are essential for computing physical properties such as kinetic energy, followed by multivariate QoIs that are more commonly used in real-world applications. The proposed method is integrated into a state-of-the-art compression framework in a modular fashion, which could easily adapt to new QoIs and new compression algorithms. Experiments on real-world datasets demonstrate that the proposed method provides faithful error control on important QoIs including kinetic energy, regional average, and isosurface without trials and errors, while offering compression ratios that are up to 4x of the compression ratios provided by state-of-the-art compressors.

Jiao, Pu↗

SU-G-BRA-02: Development of a Learning Based Block Matching Algorithm for Ultrasound Tracking in Radiotherapy

Purpose: To develop an ultrasound learning-based tracking algorithm with the potential to provide real-time motion traces of anatomy-based fiducials that may aid in the effective delivery of external beam radiation. Methods: The algorithm was developed in Matlab R2015a and consists of two main stages: reference frame selection, and localized block matching. Immediately following frame acquisition, a normalized cross-correlation (NCC) similarity metric is used to determine a reference frame most similar to the current frame from a series of training set images that were acquired during a pretreatment scan. Segmented features in the reference frame provide the basis for the localized block matching to determine the feature locations in the current frame. The boundary points of the reference frame segmentation are used as the initial locations for the block matching and NCC is used to find the most similar block in the current frame. The best matched block locations in the current frame comprise the updated feature boundary. The algorithm was tested using five features from two sets of ultrasound patient data obtained from MICCAI 2014 CLUST. Due to the lack of a training set associated with the image sequences, the first 200 frames of the image sets were considered a valid training set for preliminary testing, and tracking was performed over the remaining frames. Results: Tracking of the five vessel features resulted in an average tracking error of 1.21 mm relative to predefined annotations. The average analysis rate was 15.7 FPS with analysis for one of the two patients reaching real-time speeds. Computations were performed on an i5-3230M at 2.60 GHz. Conclusion: Preliminary tests show tracking errors comparable with similar algorithms at close to real-time speeds. Extension of the work onto a GPU platform has the potential to achieve real-time performance, making tracking for therapy applications a feasible option. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

Extended forward sensitivity analysis of one-dimensional isothermal flow

Sensitivity analysis and uncertainty quantification is an important part of nuclear safety analysis. In this work, forward sensitivity analysis is used to compute solution sensitivities on 1-D fluid flow equations typical of those found in system level codes. Time step sensitivity analysis is included as a method for determining the accumulated error from time discretization. The ability to quantify numerical error arising from the time discretization is a unique and important feature of this method. By knowing the relative sensitivity of time step with other physical parameters, the simulation is allowed to run at optimized time steps without affecting the confidence of the physical parameter sensitivity results. The time step forward sensitivity analysis method can also replace the traditional time step convergence studies that are a key part of code verification with much less computational cost. One well-defined benchmark problem with manufactured solutions is utilized to verify the method; another test isothermal flow problem is used to demonstrate the extended forward sensitivity analysis process. Through these sample problems, the paper shows the feasibility and potential of using the forward sensitivity analysis method to quantify uncertainty in input parameters and time step size for a 1-D system-level thermal-hydraulic safety code. (authors)

97 MATHEMATICS AND COMPUTING↗

Generalized Perturbation Theory-Free Sensitivity Analysis for Eigenvalue Problems

Generalized perturbation theory (GPT) has been recognized as the most computationally efficient approach for performing sensitivity analysis for models with many input parameters, which renders forward sensitivity analysis computationally overwhelming. In critical systems, GPT involves the solution of the adjoint form of the eigenvalue problem with a response-dependent fixed source. Although conceptually simple to implement, most neutronics codes that can solve the adjoint eigenvalue problem do not have a GPT capability unless envisioned during code development. We introduce in this manuscript a reduced-order modeling approach based on subspace methods that requires the solution of the fundamental adjoint equations but allows the generation of response sensitivities without the need to set up GPT equations, and that provides an estimate of the error resulting from the reduction. Moreover, the new approach solves the eigenvalue problem independently of the number or type of responses. This allows for an efficient computation of sensitivities when many responses are required. This paper introduces the theory and implementation details of the GPT-free approach and describes how the errors could be estimated as part of the analysis. The applicability is demonstrated by estimating the variations in the flux distribution everywhere in the phase space of a fast critical sphere and a high-temperature gas-cooled reactor prismatic lattice. The variations generated by the GPT-free approach are benchmarked to the exact variations generated by direct forward perturbations.

99 GENERAL AND MISCELLANEOUS↗

Byte-precision level of detail processing for variable precision analytics

I/O bottlenecks in HPC applications are becoming a more pressing problem as compute capabilities continue to outpace I/O capabilities. While double-precision simulation data often must be stored losslessly, the loss of some of the fractional component may introduce acceptably small errors to many types of scientific analyses. Given this observation, we develop a precision level of detail (APLOD) library, which partitions double-precision datasets along user-defined byte boundaries. APLOD parameterizes the analysis accuracy-I/O performance tradeoff, bounds maximum relative error, maintains I/O access patterns compared to full precision, and operates with low overhead. Using ADIOS as an I/O use-case, we show proportional reduction in disk access time to the degree of precision. Finally, we show the effects of partial precision analysis on accuracy for operations such as k-means and Fourier analysis, finding a strong applicability for the use of varying degrees of precision to reduce the cost of analyzing extreme-scale data.

Jenkins, John↗

Byte-precision level of detail processing for variable precision analytics

I/O bottlenecks in HPC applications are becoming a more pressing problem as compute capabilities continue to outpace I/O capabilities. While double-precision simulation data often must be stored losslessly, the loss of some of the fractional component may introduce acceptably small errors to many types of scientific analyses. Given this observation, we develop a precision level of detail (APLOD) library, which partitions double-precision datasets along user-defined byte boundaries. APLOD parameterizes the analysis accuracy-I/O performance tradeoff, bounds maximum relative error, maintains I/O access patterns compared to full precision, and operates with low overhead. Using ADIOS as an I/O use-case, we show proportional reduction in disk access time to the degree of precision. Finally, we show the effects of partial precision analysis on accuracy for operations such as k-means and Fourier analysis, finding a strong applicability for the use of varying degrees of precision to reduce the cost of analyzing extreme-scale data.

Jenkins, John↗

Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels

Purpose: This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detailing these case studies is to explore different, more sensitive methods and metrics that could be used more effectively for evaluating accuracy of dose algorithms, delivery systems, and QA devices.Methods: The authors present seven real-world case studies representing a variety of combinations of the treatment planning system (TPS), linac, delivery modality, and systematic error type. These case studies are typical to what might be used as part of an IMRT or VMAT commissioning test suite, varying in complexity. Each case study is analyzed according to TG-119 instructions for gamma passing rates and action levels for per-beam and/or composite plan dosimetric QA. Then, each case study is analyzed in-depth with advanced diagnostic methods (dose profile examination, EPID-based measurements, dose difference pattern analysis, 3D measurement-guided dose reconstruction, and dose grid inspection) and more sensitive metrics (2% local normalization/2 mm DTA and estimated DVH comparisons).Results: For these case studies, the conventional 3%/3 mm gamma passing rates exceeded 99% for IMRT per-beam analyses and ranged from 93.9% to 100% for composite plan dose analysis, well above the TG-119 action levels of 90% and 88%, respectively. However, all cases had systematic errors that were detected only by using advanced diagnostic techniques and more sensitive metrics. The systematic errors caused variable but noteworthy impact, including estimated target dose coverage loss of up to 5.5% and local dose deviations up to 31.5%. Types of errors included TPS model settings, algorithm limitations, and modeling and alignment of QA phantoms in the TPS. Most of the errors were correctable after detection and diagnosis, and the uncorrectable errors provided useful information about system limitations, which is another key element of system commissioning.Conclusions: Many forms of relevant systematic errors can go undetected when the currently prevalent metrics for IMRT/VMAT commissioning are used. If alternative methods and metrics are used instead of (or in addition to) the conventional metrics, these errors are more likely to be detected, and only once they are detected can they be properly diagnosed and rooted out of the system. Removing systematic errors should be a goal not only of commissioning by the end users but also product validation by the manufacturers. For any systematic errors that cannot be removed, detecting and quantifying them is important as it will help the physicist understand the limits of the system and work with the manufacturer on improvements. In summary, IMRT and VMAT commissioning, along with product validation, would benefit from the retirement of the 3%/3 mm passing rates as a primary metric of performance, and the adoption instead of tighter tolerances, more diligent diagnostics, and more thorough analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the uncertainty of temperature estimation in a rapid compression machine

Rapid compression machines (RCMs) have been widely used in the combustion literature to study the low-to-intermediate temperature ignition of many fuels. In a typical RCM, the pressure during and after the compression stroke is measured. Yet, measurement of the temperature history in the RCM reaction chamber is challenging. Thus, the temperature is generally calculated by the isentropic relations between pressure and temperature, assuming that the adiabatic core hypothesis holds. To estimate the uncertainty in the calculated temperature, an uncertainty propagation analysis must be carried out. Our previous analyses assumed that the uncertainties of the parameters in the equation to calculate the temperature were normally distributed and independent, but these assumptions do not hold for typical RCM operating procedures. Here, a Monte Carlo method is developed to estimate the uncertainty in the calculated temperature, while taking into account the correlation between parameters and the possibility of non-normal probability distributions. In addition, the Monte Carlo method is compared to an analysis that assumes normally distributed, independent parameters. Both analysis methods show that the magnitude of the initial pressure and the uncertainty of the initial temperature have strong influences on the magnitude of the uncertainty. Finally, the uncertainty estimation methods studied here provide a reference value for the uncertainty of the reference temperature in an RCM and can be generalized to other similar facilities.

42 ENGINEERING↗

Bayesian estimation of cross-section and errors of experiment and calculation for accurate prediction of neutronic characteristics

In some experiments, there might be a correlation of experimental errors such as an error caused by fabrication. The correlation of calculation errors also might exist among analyses of experiments. In the present study, considering these correlations, the cross-section and errors of experiment and calculation are adjusted for the accurate prediction of neutronic characteristics. The adjustment method is derived based on Bayesian theory. The 'a posteriori' distributions of cross-section and errors of experiment and calculation are obtained by the derivation. The case study is performed by using the benchmarks of light-water moderated experiments reported in ICSBEP. The error from fuel rod fabrication and measurement are included in the experiment error, and the error from the simplification of the benchmark model is included in the calculation error. Since these errors have a positive correlation among the benchmarks, the prediction accuracy is expected to be improved by considering these correlations. For the sensitivity analysis of the correlation among benchmarks, the correlation coefficient of experiment error and that of calculation error is assumed from 0.0 to 0.9. The results indicate that the prediction accuracy of the multiplication factor can be improved by increasing the correlation coefficient of experiment error and that of calculation error. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling noise in global Mølmer-Sørensen interactions applied to quantum approximate optimization

Many-qubit Mølmer-Sørensen (MS) interactions applied to trapped ions offer unique capabilities for quantum information processing, with applications including quantum simulation and the quantum approximate optimization algorithm (QAOA). Here, we develop a physical model to describe many-qubit MS interactions under four sources of experimental noise: vibrational mode frequency fluctuations, laser power fluctuations, thermal initial vibrational states, and state preparation and measurement errors. The model parametrizes these errors from simple experimental measurements, without free parameters. Herein, we validate the model in comparison with experiments that implement sequences of MS interactions on two 171 Yb + ions. The model shows reasonable agreement after several MS interactions as quantified by the reduced chi-squared statistic $χ^{2}_{red}$≈2. As an application we examine MaxCut QAOA experiments on three and six ions. The experimental performance is quantified by approximation ratios that are 91% and 83% of the optimal theoretical values. Our model predicts $0.93^{+0.03}_{-0.02}$ and $0.95^{+0.04}_{-0.03}$, respectively, with disagreement in the latter value attributable to secondary noise sources beyond those considered in our analysis. With realistic experimental improvements to reduce measurement error and radial trap frequency variations, the model achieves approximation ratios that are 99% of the optimal. Incorporating these improvements into future experiments is expected to reveal new aspects of noise for future modeling and experimental improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mass Variance from Archival X-ray Properties of Dark Energy Survey Year-1 Galaxy Clusters

Using archival X-ray observations and a log-normal population model, we estimate constraints on the intrinsic scatter in halo mass at fixed optical richness for a galaxy cluster sample identified in Dark Energy Survey Year-One (DES-Y1) data with the redMaPPer algorithm. We examine the scaling behavior of X-ray temperatures, $T_X$, with optical richness, $\lambda_{RM}$, for clusters in the redshift range $0.2 50\%$ complete for clusters with $\lambda_{RM} > 130$. Regression analysis on the two samples produces consistent posterior scaling parameters, from which we derive a combined constraint on the residual scatter, $\sigma_{\ln Tx | \lambda} = 0.275 \pm 0.019$. Joined with constraints for $T_X$ scaling with halo mass from the Weighing the Giants program and richness--temperature covariance estimates from the LoCuSS sample, we derive the richness-conditioned scatter in mass, $\sigma_{\ln M | \lambda} = 0.30 \pm 0.04\, _{({\rm stat})} \pm 0.09\, _{({\rm sys})}$, at an optical richness of approximately 70. Uncertainties in external parameters, particularly the slope and variance of the $T_X$--mass relation and the covariance of $T_X$ and $\lambda_{RM}$ at fixed mass, dominate the systematic error. The $95\%$ confidence region from joint sample analysis is relatively broad, $\sigma_{\ln M | \lambda} \in [0.14, \, 0.55]$, or a factor ten in variance.

79 ASTRONOMY AND ASTROPHYSICS↗

Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of user interaction and resulted in statistically not significantly different segmentation error indices (ANOVA test, significance level of 0.05). Conclusions: All three experts were able to produce liver segmentations with low error rates. User interaction time savings of up to 71% compared to a 2D refinement approach demonstrate the utility and potential of our approach. The system offers a range of different tools to manipulate segmentation results, and some users might benefit from a longer learning phase to develop efficient segmentation refinement strategies. The presented approach represents a generally applicable segmentation approach that can be applied to many medical image segmentation problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗