Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXHAUST SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

The Hall fields and fast magnetic reconnection

The results of large-scale, particle-in-cell simulations are presented on the role of Hall electric and magnetic fields on the structure of the electron dissipation region and outflow exhaust during the collisionless magnetic reconnection of antiparallel fields. The simulations reveal that the whistler wave plays the key role in driving the electrons away from the magnetic x-line. Further downstream the electron outflow exhaust consists of a narrow super-Alfvenic jet, which remains collimated far downstream of the x-line, flanked by a pedestal whose width increases monotonically with increasing distance downstream. The open outflow exhaust, which is required for fast reconnection in large systems, is driven by the Hall electric and magnetic fields. Finally, it is the whistler that ultimately facilitates fast reconnection by diverting the electrons flowing toward the current layer into the outflow direction and thereby limiting the length of this layer. The results are contrasted with reconnection in an electron-positron plasma where the Hall fields are absent. The consequence of the expanding outflow exhaust is that, consistent with recent observations, the extended super-Alfvenic electron outflow jet carries a smaller and smaller fraction of the outflowing electrons with increasing distance downstream of the x-line. The results suggest that the structure of the electron current layer and exhaust in simulations might be sensitive to boundary conditions unless the simulation boundary along the outflow direction is sufficiently far from the x-line.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of interacting dual lifting ejector systems

An analytical treatment is presented for a flowfield generated by a pair of interacting, two-dimensional parallel jets, representative of the two exhaust streams issuing from the thrust augmentor nozzles of dual lifting jet VTOL aircraft propulsion systems. Predictions of the analysis for the ratio of primary to secondary velocity are in close agreement with experimentally observed values, if the spreading rate parameter is allowed to assume a value greater than that which applies to a free jet. Theoretical results are combined with existing experimental data for unventilated jets, in order to arrive at an estimate of the thrust augmentation produced by a jet pair with an arbitrary degree of ventilation.

Lund, T. S.↗

Engine system and method including first and second turbochargers

An engine system includes an internal combustion engine having an intake passage, a first set of combustion chambers, a second set of combustion chambers, a first exhaust passage fluidly connected to the first set of combustion chambers, and a second exhaust passage fluidly connected to the second set of combustion chambers. The engine system includes a first turbocharger including a first compressor and a first turbine. The engine system also includes a second turbocharger including a second compressor and a second turbine, the second compressor connected in series with the first compressor, and the second turbine being in fluid communication with the second exhaust passage. The first and second turbines are connected in parallel such that the first turbine only receives exhaust flow from the first set of combustion chambers, and the second turbine only receives exhaust flow from the second set of combustion chambers.

Lusardi, Christopher↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simultaneous H/D/T and 3He/4He absolute concentration measurements with an optical Penning gauge on JET

The Optical Penning (or Species-Selective Penning) Gauge technique is used for the measurement of the H2/D2/T2 fuel isotopic composition and He/D2 concentration in the neutralized particle exhaust of fusion devices. An Optical Penning detection system has already been used in JET during its first deuterium-tritium campaigns (DTE1) and has been chosen by ITER. Recent improvements to the sub-divertor diagnostic suite as well as the optical instrumentation, in preparation for the next DT campaign, have improved the optical throughput of the measurement and enabled 3He/D2 detection down to 0.1 %. For the first time, the 3He/4He isotopic ratio can be measured simultaneously with the H/D/T ratio. This technique is of particular interest for ion cyclotron resonance frequency (ICRF) heating scenarios.

Vartanian, S.↗

Exergy analysis of the Chartherm process for energy valorization and material recuperation of chromated copper arsenate (CCA) treated wood waste

The Chartherm process (Thermya, Bordeaux, France) is a thermochemical conversion process to treat chromated copper arsenate (CCA) impregnated wood waste. The process aims at maximum energy valorization and material recuperation by combining the principles of low-temperature slow pyrolysis and distillation in a smart way. The main objective of the exergy analysis presented in this paper is to find the critical points in the Chartherm process where it is necessary to apply some measures in order to reduce exergy consumption and to make energy use more economic and efficient. It is found that the process efficiency can be increased with 2.3-4.2% by using the heat lost by the reactor, implementing a combined heat and power (CHP) system, or recuperating the waste heat from the exhaust gases to preheat the product gas. Furthermore, a comparison between the exergetic performances of a 'chartherisation' reactor and an idealized gasification reactor shows that both reactors destroy about the same amount of exergy (i.e. 3500 kW kg{sub wood}{sup -1}) during thermochemical conversion of CCA-treated wood. However, the Chartherm process possesses additional capabilities with respect to arsenic and tar treatment, as well as the extra benefit of recuperating materials.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low-temperature carbon monoxide oxidation catalysed by regenerable atomically dispersed palladium on alumina

Catalysis by single isolated atoms of precious metals has attracted much recent interest since it promises the ultimate economy in atom efficiency. Previous reports have been confined to reducible oxide supports such as FeO x , TiO₂ or CeO₂. Here we show that isolated Pd atoms can be stabilized on industrially relevant gamma-alumina supports. At low Pd loadings (≤0.5 wt%) these catalysts contain exclusively atomically dispersed Pd species. The addition of lanthanum-oxide to the alumina, long known for its ability to improve alumina stability, is found to also help in the stabilization of isolated Pd atoms. Aberration-corrected scanning transmission electron microscopy (AC-STEM) confirms the presence of intermingled Pd and La on the gamma-alumina surface. Operando X-ray absorption spectroscopy, performed on Pd/La-alumina and Pd/gamma-alumina (0.5 wt% Pd) demonstrates the presence of catalytically active atomically dispersed ionic Pd in the Pd/La-doped gamma-alumina system. CO oxidation reactivity measurements show onset of catalytic activity at 40 °C, indicating that the ionic Pd species are not poisoned by CO. The reaction order in CO and O₂ is positive, suggesting a reaction mechanism that is different from that on metallic Pd. The catalyst activity is lost if the Pd species are reduced to their metallic form, but the activity can be regenerated by oxidation at 700 °C in air. The high-temperature stability of these ionic Pd species on commercial alumina supports makes this catalyst system of potential interest for low-temperature exhaust treatment catalysts.

Environmental Molecular Sciences Laboratory↗

Experimental study of linear and nonlinear regimes of density-driven instabilities induced by CO{sub 2} dissolution in water

Density driven instabilities produced by CO{sub 2} (gas) dissolution in water containing a color indicator were studied in a Hele Shaw cell. The images were analyzed and instability patterns were characterized by mixing zone temporal evolution, dispersion curves, and the growth rate for different CO{sub 2} pressures and different color indicator concentrations. The results obtained from an exhaustive analysis of experimental data show that this system has a different behaviour in the linear regime of the instabilities (when the growth rate has a linear dependence with time), from the nonlinear regime at longer times. At short times using a color indicator to see the evolution of the pattern, the images show that the effects of both the color indicator and CO{sub 2} pressure are of the same order of magnitude: The growth rates are similar and the wave numbers are in the same range (0–30 cm{sup −1}) when the system is unstable. Although in the linear regime the dynamics is affected similarly by the presence of the indicator and CO{sub 2} pressure, in the nonlinear regime, the influence of the latter is clearly more pronounced than the effects of the color indicator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification and control of the exhaust using gas perturbations in the DIII-D tokamak

This paper presents perturbative experiments that enable the validation and development of control-oriented models for exhaust control. We identify the response of the divertor plasma and scrape-off layer in the DIII-D tokamak to deuterium and nitrogen multi-sine perturbations, in favorable and unfavorable field directions for H-mode access. We obtained good signal-to-noise ratios in the 1–10 Hz frequency range by measuring Balmer-alpha, Lyman-alpha, and N 4+ line emission, radiated power, and neutral pressure. We find a similar phase response across gas species and magnetic field directions, while the gain response is nonlinear. With these experiments, we identify a control-oriented model to design a divertor radiated power controller to track specified reference waveforms in conjunction with resonant magnetic perturbations. Although the physics basis for compatibility between detachment and resonant magnetic perturbation edge-localized mode suppression remains to be demonstrated, the present results provide a robust controller that represents a promising step toward future joint control strategies.

detachment control↗

Machine learning mathematical models for incidence estimation during pandemics

Accurate estimates of the incidence of infectious diseases are key for the control of epidemics. However, healthcare systems are often unable to test the population exhaustively, especially when asymptomatic and paucisymptomatic cases are widespread; this leads to significant and systematic under-reporting of the real incidence. Here, we propose a machine learning approach to estimate the incidence of a pandemic in real-time, using reported cases and the overall test rate. In particular, we use Bayesian symbolic regression to automatically learn the closed-form mathematical models that most parsimoniously describe incidence. We develop and validate our models using COVID-19 incidence values for nine different countries, confirming their ability to accurately predict daily incidence. Remarkably, despite the differences in epidemic trajectories and dynamics across countries, we find that a single model for all countries offers a more parsimonious description and is more predictive of actual incidence compared to separate models for each country. Our results show the potential to accurately model incidence in real-time using closed-form mathematical models, providing a valuable tool for public health decision-makers.

Fajardo-Fontiveros, Oscar (ORCID:0000000207058972)↗

Oneida Indian Nation Facility Energy Efficiency Project (Final Technical Report)

The Oneida Indian Nation (“Oneida”) implemented a comprehensive energy efficiency project across nearly 30 facilities over the course of the project period. Grounded in findings from a 2018 energy audit, the project installed LED lighting, high-efficiency HVAC systems, programmable thermostats, variable speed drives, and kitchen exhaust controls across 28 Nation facilities and the Turning Stone Resort and Casino (TSRC) campus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Liquid propellant rockets.

A brief overview of the state of knowledge in liquid rocket technology is presented and examples are provided of instances where some fundamental principles of chemistry, fluid mechanics, and mathematics can be applied. A liquid propellant rocket classification is discussed together with rocket system performance, applications for liquid propellants, the effective exhaust velocity, aspects of simplified nozzle expansion, questions about theoretical propellant performance, the effect of chamber pressure on equilibrium performance, and the kinetic recombination in nozzles. Details of propellant combustion are examined, giving attention to propellant injection, evaporation-controlled combustion, combustion instability, and monopropellant decomposition.

Dipprey, D. F.↗

Pollution reduction technology program for class T4(JT8D) engines

The technology required to develop commercial gas turbine engines with reduced exhaust emissions was demonstrated. Can-annular combustor systems for the JT8D engine family (EPA class T4) were investigated. The JT8D turbofan engine is an axial-flow, dual-spool, moderate-bypass-ratio design. It has a two-stage fan, a four-stage low-pressure compressor driven by a three-stage low-pressure turbine, and a seven-stage high-pressure compressor driven by a single-stage high-pressure turbine. A cross section of the JT8D-17 showing the mechanical configuration is given. Key specifications for this engine are listed.

Roberts, R.↗

Evaluation of the in-flight noise signature of a 32-chute suppressor nozzle: Acoustic data report

Outdoor static and 40 x 80 FT wind tunnel tests of the J79-15 engine/nacelle system with the conic nozzle and 32-chute exhaust suppressor were conducted to acquire the data necessary to evaluate the simulated in-flight signature of an engine-size 32-chute exhaust nozzle suppressor using the 40 x 80 ft wind tunnel and to study possible engine core noise contamination of the jet signature. The tests are described and and a sampling of the data acquired is presented. Included are aero performance summaries, as-measured and composite 1/3 OBSPL spectra for the 70 ft sideline high and low mics from the outdoor static tests, sideline traverse spectra and internal noise measurements from both the outdoor static and the 40 x 80 ft wind tunnel tests.

Moore, M. T.↗

Formulation of design guidelines for automated robotic assembly in outerspace

The approach for arriving at design guidelines for assembly by robots in outerspace is illustrated. The use of robots in a zero gravity environment necessitates that extra factors over and above normal design guidelines be taken into account. Besides, many of the guidelines for assembly by robots on earth do not apply in space. However, considering the axioms for normal design and assembly as one set, guidelines for design and robotic assembly as another, and guidelines for design and assembly in space as the third set, unions and intersections of these sets can generate guidelines for two or more of these conditions taken together - say design and manual assembly in space. Therein lies the potential to develop expert systems in the future, which would use an exhaustive database and similar guidelines to arrive at those required by a superposition of these conditions.

Dwivedi, Suren N.↗

Flow Energy Piezoelectric Bimorph Nozzle Harvester

There is a need for a long-life power generation scheme that could be used downhole in an oil well to produce 1 Watt average power. There are a variety of existing or proposed energy harvesting schemes that could be used in this environment but each of these has its own limitations. The vibrating piezoelectric structure is in principle capable of operating for very long lifetimes (decades) thereby possibly overcoming a principle limitation of existing technology based on rotating turbo-machinery. In order to determine the feasibility of using piezoelectrics to produce suitable flow energy harvesting, we surveyed experimentally a variety of nozzle configurations that could be used to excite a vibrating piezoelectric structure in such a way as to enable conversion of flow energy into useful amounts of electrical power. These included reed structures, spring mass-structures, drag and lift bluff bodies and a variety of nozzles with varying flow profiles. Although not an exhaustive survey we identified a spline nozzle/piezoelectric bimorph system that experimentally produced up to 3.4 mW per bimorph. This paper will discuss these results and present our initial analyses of the device using dimensional analysis and constitutive electromechanical modeling. The analysis suggests that an order-of-magnitude improvement in power generation from the current design is possible.

transducers↗

Source Contaminant Control for the Heat Melt Compactor

The Logistics Reduction and Repurposing project includes the heat melt compactor (HMC), a device that compacts waste containing plastic into a tile that will minimize volume, and may be used as materials for radiation shielding. During the process, a small purge gas stream is directed through the HMC chamber to transport out gasses and humidity released from the process. NASA Marshall Space Flight Center is tasked with developing and delivering a contamination control system to clean the purge gas prior to exhausting it back into the cabin for crew inhalation.

Roman, Monsi↗

Use of Multipass Recirculation and Energy Recovery In CW SRF X-FEL Driver Accelerators

We discuss the use of multipass recirculation and energy recovery in CW SRF drivers for short wavelength FELs. Benefits include cost management (through reduced system footprint, required RF and SRF hardware, and associated infrastructure - including high power beam dumps and cryogenic systems), ease in radiation control (low drive beam exhaust energy), ability to accelerate and deliver multiple beams of differing energy to multiple FELs, and opportunity for seamless integration of multistage bunch length compression into the longitudinal matching scenario. Issues include all those associated with ERLs compounded by the challenge of generating and preserving the CW electron drive beam brightness required by short wavelength FELs. We thus consider the impact of space charge, BBU and other environmental wakes and impedances, ISR and CSR, potential for microbunching, intra-beam and beam-residual gas scattering, ion effects, RF transients, and halo, as well as the effect of traditional design, fabrication, installation and operational errors (lattice aberrations, alignment, powering, field quality). Context for the discussion is provided by JLAMP, the proposed VUV/X-ray upgrade to the existing Jefferson Lab FEL.

43 PARTICLE ACCELERATORS↗