SEARCH · Engineering Papers
Results for “EXERCISE”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Joint Sensitivity Analysis (JOSA) Exercise Meeting Sept. 21, 2021.
Abstract not provided.
Joint Analysis Exercise on Uranium Pellets
Explore the source record for details and available documents.
DECOVALEX 2023 TASK G: Step1 and Step 2 - Benchmark Exercises: G1-M-BE-2D and G2-HM-BE-2D SNL Modeling Progress.
Abstract not provided.
Trepanning Graphite Samples at a Shutdown Magnox Reactor: A US-UK Joint Exercise for Nuclear Verification
In April 2022, a team sponsored by the US DOE Office of Nuclear Verification (ONV) shipped trepanning equipment to the nuclear power station at Trawsfynydd, Wales, UK to collect samples from the graphite moderator of Reactor 1. The sampling campaign to collect 48 graphite samples was completed in five weeks beginning July 11. Half the samples will be analyzed in the US to determine the total energy production of the facility. The other half will be analyzed by Magnox Ltd. to support decisions for options for the ultimate decommissioning path for the facility. This paper provides a description of the equipment and the operations required to trepan, collect, and package the samples while controlling the small amounts of radioactive graphite dust entrained on and within the tool. The most important sample parameter needed is the precise location of the sample, to within ±6 mm in a fuel channel, while the tool is deployed to between 12 and 20 meters below the operations floor; our means of achieving this precision is given.
Godiva-IV Dosimetry Exercise 2022 Preliminary Results
Explore the source record for details and available documents.
Report on Opportunities with Neutron Beams from the LRP Exercise
Explore the source record for details and available documents.
The 2022 Hunga eruption exercises the nuclear explosion monitoring community
The 2022 Hunga eruption was a global event recorded by all three Comprehensive Test Ban Treaty Organization (CTBTO) International Monitoring System (IMS) geophysical waveform sensor technologies: seismic, infrasound, and hydroacoustic. Large volcanic eruptions are rare and additionally present an opportunity to test seismoacoustic detection, location, and identification methods for nuclear explosion monitoring.
Wind Turbine Noise Code Benchmark: A Comparison and Verification Exercise: Preprint
In a number of institutions and companies, researchers and engineers are developing modeling numerical frameworks that are used to predict the aerodynamic noise emission from a wind turbine rotor. The simulation codes vary from empirically-tuned engineering models to high-fidelity computational ones. Their common feature is the fact that they all specifically model the main aerodynamic noise mechanisms occurring at the rotating blades, namely trailing edge noise and turbulent inflow noise. Nevertheless, it can be expected that these different modeling frameworks will produce different results for a same given rotor design, and identical operating conditions. Trailing edge noise is put at the forefront of the study as it is recognized as the main audible source of noise from wind turbines. The present benchmark aims at comparing the results from the different modeling approaches, and drawing some conclusions from these comparisons. This effort, denoted as Wind Turbine Noise Code benchmark, was initiated in 2019 as a joint-activity between the IEA Wind Task 39 (Quiet Wind Turbine Technology) and Task 29 (Detailed Aerodynamics of Wind Turbines, now Task 47). In addition to the investigation of the noise emissions themselves, the rotor aerodynamic characteristics are investigated as they have a significant impact on the noise generation mechanisms. A number of test cases are defined and the aerodynamic and aeroacoustic predictions from the various models are compared. There exist some discrepancies between the different methods, but it is difficult to conclude if one methodology is better than another in order to design a wind turbine with noise as a constraint.
ON THE APPLICATION OF THE AREA METRIC TO VALIDATION EXERCISES OF STOCHASTIC SIMULATIONS.
Abstract not provided.
Joint Training Exercises Among Radiological Security Stakeholders.
Abstract not provided.
RELAP5-3D Solutions to Exercise 1 of the OECD-NEA HTTF Benchmark
The high-temperature gas-cooled reactor (HTGR) is an advanced reactor concept that has received considerable attention over the last 60 years. HTGRs boast high coolant outlet temperatures, passive safety, and large margins to fuel failure. Recent years have seen increasing interest in HTGRs, whether large-scale HTGRs for electricity or process heat applications or as microreactors serving remote communities. HTGRs have considerable potential to fulfill these applications, but modeling and simulation tools typically used for reactor safety analysis have not been validated for HTGR modeling. The High-Temperature Test Facility (HTTF) was constructed at Oregon State University (OSU) to provide validation data for HTGR modeling. Recently, Idaho National Laboratory (INL), OSU, Argonne National Laboratory, Canadian Nuclear Laboratories, and the University of Tennessee Knoxville have collaborated to develop an HTGR thermal hydraulics benchmark based on HTTF experiments. This summary presents results from a portion of that benchmark using RELAP5-3D
Excercise Within LBNP as an Artificial Gravity Countermeasure
Previous exercise in space has lacked sufficient loads to maintain preflight cardiovascular and musculoskeletal mass and function. Lower body negative pressure (LBNP) produces a static force equivalent to one Earth body weight by each 52 mm Hg of LBNP during supine posture. LBNP also provides transmural blood pressures simulating upright exercise. Thus, this artificial-gravity concept may help maintain cardiovascular and musculoskeletal systems of crewmembers during prolonged exposure to microgravity. Currently available, bungee cord assisted, treadmill exercise is limited by harness discomfort, lower than normal loads, abnormal post-flight gait, and the absence of gravitational blood pressures within the vascular system. PURPOSE: This project evaluates a method to create artificial gravity using supine LBNP treadmill exercise to prevent loss of physiologic function in microgravity simulated by 30 days of bed rest. Identical twins were used as volunteers so that statistical power could be maximized. This countermeasure is being transitioned to space flight. CURRENT STATUS OF RESEARCH Methods: Six sets of identical twins (6 females and 14 males, 21-36 years) remained in 6 head-down tilt (HDT) bed rest for 30 days to simulate prolonged microgravity. Six subjects were randomly selected to exercise supine in an LBNP chamber for 40 minutes six days per week (EX group), while their twin brothers served as non-exercise controls (CON). Pressure within the exercise LBNP chamber was adjusted to increase load, hence increasing exercise intensity. During supine treadmill exercise, LBNP (52-63 mmHg) was applied to produce foot ward forces equivalent to those for upright running on Earth at 1.0-1.2 times body weight (BW) and subjects performed an interval exercise protocol (40-80% peak exercise capacity [VO2pk]). Five minutes of resting LBNP immediately followed each exercise session. Results: Orthostatic tolerance time decreased significantly after 30 days bed rest in the CON group, but was relatively maintained in the EX group. VO2pk was maintained in EX males, but not in CON males. Isokinetic knee strength (extension, peak torque) decreased significantly in CON males, but was preserved in EX males. The EX group had significantly higher spine muscle strength after bed rest than the CON group. The cross-sectional area of spinal muscle at L4/5 level decreased significantly in the CON group but not in the EX group. Urinary n-telopeptide excretion, an index of bone resorption, was increased during bed rest in CON, but not in EX subjects. This suggests protection by LBNP exercise against the increase in bone resorption typically seen in simulated and actual microgravity. Significant changes in bone mineral density (BMD) in the spine and ribs were observed in CON subjects, but not in EX subjects. Conclusions: Our treadmill exercise protocol within LBNP plus a short period of post-exercise LBNP maintains orthostatic responses, upright exercise capacity and other important physiologic parameters during bed rest. These results document the efficacy of our apparatus and exercise protocol for maintaining physiologic structure and function during long-duration microgravity as simulated by 30 days of HDT bed rest. FUTURE PLANS: More sets of female identical twins are needed to reach significance. The LBNP exercise chamber will be redesigned for flight.
Comparison of Orion Flywheel to Commercially Available Flywheel Device
INTRODUCTION: The chosen exercise device for the Orion Multi-purpose Crew Vehicle (MPCV) for Artemis missions is the Orion Flywheel (OFW), which was selected in 2017 from a pool of exercise devices. The Orion Flywheel is to be installed in the MPCV for its first use during the Artemis II mission and will be utilized for subsequent Artemis missions. The OFW provides the capability to perform both resistive and aerobic exercises while taking up a small volume and not requiring power. Aerobic exercise consists of rowing while resistive exercise includes the deadlift, harness squat, and deadlift high pull among others. The efficacy of the OFW as an exercise countermeasure to spaceflight deconditioning has not yet been fully evaluated. A future HRP-funded study using head-down tilt bed rest is planned to evaluate the efficacy of the OFW to mitigate aerobic and muscular deconditioning. The OFW, made by KBR, is a specialized device that poses high costs for purchase and maintenance. The aim of the study is to determine if a commercially available alternative could be used as a backup for the OFW during the bed rest study or as an alternative in other studies. This study seeks to compare the loading profile and mechanics of a commercial flywheel device (kBox Pro) with the three resistance settings of the OFW using a controlled, instrumented setup to validate its acceptability as a backup. METHODS: An experimental setup was designed to simulate human use of the OFW. Flywheel devices can have varied actuated inertial mass and strap length. The inertial mass refers to the flywheel itself or the object that spins as the result of the movement of the strap. The OFW has three gears actuated with a lever, with the low gear used for aerobic rowing and the medium and high gears used for resistance exercises. These gears correspond to increasing flywheel inertia, which corresponds to a certain number and sizes of inertial plates on a commercial flywheel. The kBox Pro has varied sizes of inertial discs that are installed to the external shaft of the device and can be configured to roughly match the inertia seen in the OFW per gear setting. The strap length can be adjusted to allow for different ranges of motion. The experimental setup allows for the simulation of rowing, harness squats, and deadlift high pulls with corresponding exercise strap lengths. All three OFW gears are to be tested, as well as multiple combinations of kBox discs. The setup was created using a system of pulleys and cables to minimize friction loss. The system is actuated through the dropping of a connected mass which, through the pulley system, pulls the strap of the exercise device upwards as if a human was exercising. A string potentiometer and tensile force transducer are used to measure strap displacement and strap force, respectively. The masses dropped are exercise chains that simulate the decrease in force observed throughout a typical exercise. As the chains are lowered to the ground, they begin to spool and therefore are no longer subjecting the exercise device’s strap to their load. This setup was designed to provide realistic loads and protect the OFW from damage, an important precaution because it’s the only available unit for research and ground operations. Data is to be collected across simulated exercises and with different strap lengths, with the same conditions collected on both the OFW and the kBox Pro. RESULTS: Data collection is ongoing for the kBox and the Orion Flywheel. CONCLUSIONS: Study results will inform if the OFW and a kBox Pro device can be deemed mechanically similar. Depending on the results, additional data collection may be required to assess the user experience between the devices. A key result of this study is a mechanical characterization of the OFW device, demonstrating the load and force profile using a repeatable test method. This data will guide next steps on potential kBox Pro modifications needed to produce a comparable exercise experience to the OFW.
Evidence for metaboreceptor stimulation of sweating in normothermic and heat-stressed humans
1. Isometric handgrip (IHG) exercise increases sweat rate and arterial blood pressure, and both remain elevated during post-exercise ischaemia. The purpose of this study was to identify whether the elevation in arterial blood pressure during post-exercise ischaemia contributes to the increase in sweating. 2. In normothermia and during whole-body heating, 2 min IHG exercise at 40% maximal voluntary contraction, followed by 2 min post-exercise ischaemia, was performed with and without bolus intravenous administration of sodium nitroprusside during the ischaemic period. Sodium nitroprusside was administered to reduce blood pressure during post-exercise ischaemia to pre-exercise levels. Sweat rate was monitored over two microdialysis membranes placed in the dermal space of forearm skin. One membrane was perfused with the acetylcholinesterase inhibitor neostigmine, while the other was perfused with the vehicle. 3. In normothermia, IHG exercise increased sweat rate at the neostigmine-treated site but not at the control site. Sweat rate remained elevated during post-exercise ischaemia even after mean arterial blood pressure returned to the pre-IHG exercise baseline. Subsequent removal of the ischaemia stimulus returned sweat rate to pre-IHG exercise levels. Sweat rate during post-exercise ischaemia without sodium nitroprusside administration followed a similar pattern. 4. During whole-body heating, IHG exercise increased sweat rate at both neostigmine-treated and untreated sites. Similarly, regardless of whether mean arterial blood pressure remained elevated or was reduced during post-exercise ischaemia, sweat rate remained elevated during the ischaemic period. 5. These results suggest that sweating in non-glabrous skin during post-IHG exercise ischaemia is activated by metaboreflex stimulation and not via baroreceptor loading.
Risk of Impaired Performance Due to Reduced Muscle Mass, Strength &, Endurance (Short Title: Muscle) and Risk of Reduced Physical Performance Capabilities Due to Reduced Aerobic Capacity (Short Title: Aerobic)
This report reviews the scientific literature regarding the human system risks to the microgravity environment of space flight in relation to human performance. The primary human performance-related risks involve deconditioning of the cardiovascular and skeletal muscles systems due to prolonged exposure to the reduced gravitational input. The chronological history of U.S. space flight is reviewed as a starting point to inform and understand the gaps in the knowledge to these risks. Maintenance of physical performance capabilities involves understanding the health of many organ systems (peripheral [vascular, heart, blood volume, skeletal muscle] and central [brain]) that ultimately contribute to the submaximal and maximal capacity of the aerobic (VO2peak), skeletal muscle (strength and endurance) systems. Maintaining astronaut VO2peak, muscle mass, strength, and endurance before, during, and after space flight is a significant priority to NASA for the current International Space Station (ISS) era, as well as for future exploration missions. A growing research database from both space flight and ground-based analog studies finds that the cardiorespiratory system is compromised and skeletal muscles (predominantly postural muscles of the lower limbs) undergo atrophy. These structural and metabolic responses to living in microgravity conditions contribute to physiological deconditioning during space flight that potentially increase the risks to astronauts returning to surface operations (i.e., Moon, Mars, or Earth). The time course changes from short to long-duration space flight and the relationships between in-flight performance deconditioning levels are not well characterized. Moreover, there are large interindividual variabilities that may be dependent on genetics, age, sex, preflight fitness levels, and individual exercise prescriptions that need further careful evaluations. Efforts should be made to understand the current status of preflight, in-flight, and postflight exercise performance capability and to define the operational goals and target areas for protection with the in-flight exercise program. There is a bi-directional relationship between exercise prescription and hardware countermeasures that need further understanding in-flight. For example, hardware with limited capabilities/modalities may be counterbalanced by changes in exercise prescription (i.e., frequency, time, intensity, volume) for providing effective responses to maintain fitness. Importantly, the minimal requirements for exercise prescription on ISS hardware may not translate to lower capability hardware on exploration missions. Due to limited volume on exploration vehicles, future Artemis missions to the Lunar surface will not have similar exercise hardware capabilities as ISS. This may alter the effectiveness of hardware to provide adequate physiological stress on bodily systems allowing for adaptations to maintain aerobic capacity, strength, and bone density. Thus, it will be important to understand the exercise responses of current ISS countermeasures to develop individualized exercise prescriptions that minimize aerobic and muscular risks, accounting for the large variability of responses among crewmembers. Newer exploration exercise hardware is currently being evaluated that is more compact (i.e., E4D and Orion Flywheel) and will require careful evaluation of the hardware on the stressor (i.e., metabolic rate, oxygen uptake, and heart rate work relationships, and force plate load profiles) needed the human body to protect and maintain crew health and performance. Moreover, exercise responses on the hardware need careful evaluation on the chronic adaptations. Lastly, in-flight evaluation of hardware exercise response may differ in 0-g or partial-g compared to 1-g. Therefore, it cannot be assumed that the stress on the body will be the same in each environment. Understanding this has a direct impact on exercise prescriptions. This document provides an overview of key scientific investigations that have been conducted before, during, and after human space flight missions, as well as from human ground-based analog studies that contribute to the evidence base on changes in aerobic capacity and muscle mass, strength, and endurance. Additional data from rodent and nonhuman primate experiments of skeletal muscle unloading completed during space flight or ground-based flight-simulations provide supportive information about this risk topic. Most importantly, a recent, large dataset from long-duration ISS crew has been added to give improved insight into the variability of exercise response of crew, demonstrating that a large portion of the crew population return to Earth with greater than 10-20% loss of aerobic capacity and muscle strength and endurance. Data from human space flight and ground-based studies are narrowing in on the required exercise paradigms but thus far still provide an incomplete answer to an effective approach for maintaining skeletal muscle function and aerobic fitness of all human space travelers. Finally, the relationship of this risk topic to various space flight operational scenarios is examined and discussed.
Muscle metaboreceptor modulation of cutaneous active vasodilation
PURPOSE: Isometric handgrip exercise in hyperthermia has been shown to reduce cutaneous vascular conductance (CVC) by inhibiting the cutaneous active vasodilator system. METHODS: To identify whether this response was initiated by muscle metaboreceptors, in seven subjects two 3-min bouts of isometric handgrip exercise in hyperthermia were performed, followed by 2 min of postexercise ischemia (PEI). An index of forearm skin blood flow (laser-Doppler flowmetry) was measured on the contralateral arm at an unblocked site and at a site at which adrenergic vasoconstrictor function was blocked via bretylium iontophoresis to reveal active cutaneous vasodilator function unambiguously. Sweat rate was measured via capacitance hygrometry, CVC was indexed from the ratio of skin blood flow to mean arterial pressure and was expressed as a percentage of maximal CVC at that site. In normothermia, neither isometric exercise nor PEI affected CVC (P > 0.05). RESULTS: The first bout of isometric handgrip exercise in hyperthermia reduced CVC at control sites and this reduction persisted through PEI (pre-exercise: 59.8 +/- 5.4, exercise: 49.8 +/- 4.9, PEI: 49.7 +/- 5.3% of maximum; both P < 0.05), whereas there were no significant changes in CVC at the bretylium treated sites. The succeeding bout of isometric exercise in hyperthermia significantly reduced CVC at both untreated (pre-exercise: 59.0 +/- 4.8, exercise: 47.3 +/- 4.0, PEI: 50.1 +/- 4.1% of maximum; both P < 0.05) and bretylium treated sites (pre-exercise: 61.4 +/- 7.3, exercise: 50.6 +/- 5.1, PEI: 53.9 +/- 6.0% of maximum, both P < 0.05). At both sites, CVC during PEI was lower than during the pre-exercise period (P < 0.05). Sweat rate rose significantly during both bouts of isometric exercise and remained elevated during PEI. CONCLUSIONS: These data suggest that the reduction in CVC during isometric exercise in hyperthermia, including the inhibition of the active vasodilator system, is primarily mediated by muscle metaboreceptors, whereas central command or muscle mechanoreceptors have less influence.