Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Descriptor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Uncertainty Visualization of Critical Points of 2D Scalar Fields for Parametric and Nonparametric Probabilistic Models

This paper presents a novel end-to-end framework for closed-form computation and visualization of critical point uncertainty in 2D uncertain scalar fields. Critical points are fundamental topological descriptors used in the visualization and analysis of scalar fields. The uncertainty inherent in data (e.g., observational and experimental data, approximations in simulations, and compression), however, creates uncertainty regarding critical point positions. Uncertainty in critical point positions, therefore, cannot be ignored, given their impact on downstream data analysis tasks. Here, in this work, we study uncertainty in critical points as a function of uncertainty in data modeled with probability distributions. Although Monte Carlo (MC) sampling techniques have been used in prior studies to quantify critical point uncertainty, they are often expensive and are infrequently used in production-quality visualization software. We, therefore, propose a new end-to-end framework to address these challenges that comprises a threefold contribution. First, we derive the critical point uncertainty in closed form, which is more accurate and efficient than the conventional MC sampling methods. Specifically, we provide the closed-form and semianalytical (a mix of closed-form and MC methods) solutions for parametric (e.g., uniform, Epanechnikov) and nonparametric models (e.g., histograms) with finite support. Second, we accelerate critical point probability computations using a parallel implementation with the VTK-m library, which is platform portable. Finally, we demonstrate the integration of our implementation with the ParaView software system to demonstrate near-real-time results for real datasets.

97 MATHEMATICS AND COMPUTING↗

How Much Chemistry Does a Deep Neural Network Need to Know to Make Accurate Predictions?

In the last few years, we have seen the rise of deep learning applications in a broad range of computational chemistry research problems. Using human-engineered chemical features, such as molecular descriptors and fingerprints, deep learning models have shown similar, if not better performance that most traditional machine learning algorithms. Recently, we reported on the development of Chemception, a deep convolutional neural network (CNN) architecture for general-purpose small molecule property prediction. On average, Chemception matched the performance of expert-developed QSAR/QSPR models trained on chemical features (molecular fingerprints), despite that it was trained on just 2D images of molecular drawings with minimal chemical information. Here, we investigate the effects of systematically removing and adding basic chemical information to the image channels of the 2D images used to train Chemception. By augmenting our images with only 3 additional basic chemical information, we demonstrate the improvement of Chemception performance – that it is now more accurate than contemporary deep learning models trained on ECFP fingerprints for the prediction of toxicity, activity and solvation free energy, as well as physics-based free energy simulation methods for computing solvation properties. By altering the chemical information content in the image channels, and examining the resulting performance of Chemception, we also identify to two different “learning patterns” in toxicity/activity as compared to solvation free energy, and it parallels the fundamental differences in contemporary chemistry research for predicting toxicity/activity and solvation free energy.

Artificial Intelligence, Cheminformatics, Computat↗

Evaluating the potential for bird‐habitat models to support biodiversity‐friendly urban planning

Abstract Urban expansion poses a major threat to wildlife populations. Biodiversity‐friendly urban landscapes could deliver benefits for both wildlife and people, by incorporating conservation and ecosystem services objectives. Well‐designed urban developments could also soften the ecological impacts of urbanization. However, delivering urban landscapes that integrate biodiversity requirements effectively remains challenging. Ecological models, designed to predict wildlife population responses to alternative urban designs, could prove effective in supporting the creation of biodiversity‐friendly urban landscapes. Here, we combine national‐scale bird abundance data with high resolution, spatially explicit habitat data to characterize relationships between bird densities and urban landscape form in Britain. From these analyses and cross validation, we evaluate the potential for well‐parameterized, species‐specific models to be used to predict bird densities in novel or modified urban areas. Our analyses indicate that responses of bird abundance to urban habitat are species‐specific and complex, with few variables consistently affecting a large proportion of species. However, contiguous areas of greenspace within urban sites are preferential for accommodating breeding birds, compared to a more fragmented arrangement of multiple, small greenspace patches. In combination, the bird‐habitat relationships identified could successfully predict observed variation in abundance for most bird species considered. Further evaluation of habitat descriptor variables, spatial scales of species' habitat use and analytical modelling approaches may be needed to improve the predictive ability of bird‐habitat models for certain species, particularly waterbirds and those observed less frequently in urban areas. Synthesis and applications . We modelled breeding bird abundance in built‐up areas with respect to the characteristics and contexts of urban environments. While most variables were important for multiple species, responses overall were species‐specific, so simple assemblage metrics, like diversity, will not describe the variation in bird communities well. However, the results illustrate the potential of an evidence‐based, spatially explicit evaluation of urban development impacts on biodiversity, by predicting the consequences for bird numbers. Subject to verification of predictive ability, practitioners can apply the models to compare, for example, land‐sparing and sharing within developments, or to quantify the biodiversity requirements for effective offsetting. This would be facilitated by incorporation into an online tool allowing user‐determined input scenarios.

Plummer, Kate E.↗

Quantifying vegetation and canopy structural complexity from terrestrial LiDAR data using the FORESTR R package

Terrestrial LiDAR (light detection and ranging) technologies have created new means of quantifying forest canopy structure, allowing not only the estimation of biomass, but also descriptions of the position and variability in canopy elements in space. Such measures provide novel structural information broadly useful to ecologists. There is a growing need for both a detailed taxonomy of forest canopy structural complexity (CSC) and open, transparent, and flexible tools to quantify complexity in ways that will advance foundational ecological knowledge of structure-function relationships. The CSC taxonomy we present groups structural descriptors into five categories: leaf area and density, canopy height, canopy arrangement, canopy openness, and canopy variability. This paper also introduces the r package forestr, the first open-source r package for the calculation of CSC metrics from terrestrial LiDAR data. The r package forestr is an analysis toolbox that works with portable canopy LiDAR (PCL) data and other pixelated/voxelized point clouds derived from terrestrial LiDAR scanning (TLS) data to calculate CSC metrics of interest to ecologists, modellers, forest managers, and remote sensing scientists.

52 ecosystem↗

Impact of non‐framework cation mixing on the structure and crystallization behavior of model high‐level waste glasses

Abstract Spinel crystallization is known to be detrimental to the operation of Joule heated ceramic melters during the vitrification of iron‐rich high‐level nuclear wastes (HLW) into borosilicate glasses. The literature on this subject focuses on tackling the problem by developing empirical constraints to design compositions, which limit the fraction of spinels formed in the melter or by developing empirical models to predict the settling behavior of spinels in the melter as a function of the glass composition. While these empirical models can predict the behavior of most of the compositions, they are not failsafe as there are always some compositions, whose behavior is beyond the predictive ability of these models. This can lead to undesirable situations during the vitrification of the nuclear waste, and therefore an in‐depth investigation of the chemo‐structural descriptors controlling the crystallization behavior in these glasses is warranted. Accordingly, the present study aims to understand the impact of non‐framework cation mixing (i.e., Li + /Na + and Ca 2+ /Na + ) on the structure (through Raman spectroscopy and Mössbauer spectroscopy) and crystallization behavior (through XRD, SEM‐EDS, and vibrating sample magnetometry) of iron‐rich model HLW glasses in the system: (mol.%) x M y O–(25− x ) Na 2 O–9.12 B 2 O 3 –6.4 Al 2 O 3 –51.25 SiO 2 –7.22 Fe 2 O 3 –0.38 MnO–0.08 Cr 2 O 3 –0.55NiO (M y O = Li 2 O or CaO).

Balasubramanya, Nikhila↗

Predicting initial dissolution rates using structural features from molecular dynamics simulations

Predicting chemical durability of glass materials is important for various applications from daily life such as drink glass and kitchen ware to advanced technologies such as nuclear waste disposal and biomedicine. In this work, we explored prediction of initial dissolution rate through structural features from molecular dynamics (MD) simulations for a wide range of glass compositions (total 28) including borosilicate and aluminosilicate glasses, ZrO 2 -containing and V 2 O 5 -containing boroaluminosilicate glasses. The initial dissolution rates (r 0 ) measured experimentally at 90 °C with varying solution conditions were correlated with structural features (e.g., polyhedral linkages and non-bridging oxygen species) obtained from MD simulations, either from this study or from literature. Since hydrolysis of the glass network through breaking of the network former linkages (e.g., Si-O-Si, Si-O-Al, etc.) is a critical step of network glass dissolution, the statistics of these linkages obtained from MD were correlated to r0 through linear regression, where the coefficient of determination (R 2 ) and root mean square error are found to be 0.949 and 0.681, respectively. This model was compared and discussed with existing models developed by various approaches including machine learning, the kinetic rate equation, topological constraint theory, and other descriptors from MD simulations. The discussion provides insights on future model improvements to predict glass dissolution. In addition, the impact of V 2 O 5 on the glass dissolution was examined in detail, implicating that the impact is not the same across all glass compositions and test conditions.

36 MATERIALS SCIENCE↗

Scanning electron microscopy image representativeness: morphological data on nanoparticles

Summary A sample of a nanomaterial contains a distribution of nanoparticles of various shapes and/or sizes. A scanning electron microscopy image of such a sample often captures only a fragment of the morphological variety present in the sample. In order to quantitatively analyse the sample using scanning electron microscope digital images, and, in particular, to derive numerical representations of the sample morphology, image content has to be assessed. In this work, we present a framework for extracting morphological information contained in scanning electron microscopy images using computer vision algorithms, and for converting them into numerical particle descriptors. We explore the concept of image representativeness and provide a set of protocols for selecting optimal scanning electron microscopy images as well as determining the smallest representative image set for each of the morphological features. We demonstrate the practical aspects of our methodology by investigating tricalcium phosphate, Ca 3 (PO 4 ) 2 , and calcium hydroxyphosphate, Ca 5 (PO 4 ) 3 (OH), both naturally occurring minerals with a wide range of biomedical applications.

ODZIOMEK, KATARZYNA↗

Leaves as bottlenecks: The contribution of tree leaves to hydraulic resistance within the soil–plant–atmosphere continuum

Within vascular plants, the partitioning of hydraulic resistance along the soil-to-leaf continuum affects transpiration and its response to environmental conditions. In trees, the fractional contribution of leaf hydraulic resistance (R leaf ) to total soil-to-leaf hydraulic resistance (R total ), or fR leaf (= R leaf /R total ), is thought to be large, but this has not been tested comprehensively. Here, we compiled a multi-biome dataset of fR leaf using new and previously published measurements of pressure differences within trees in situ. Across 80 samples, fR leaf averaged 0.51 (95% confidence interval [CI] = 0.46-0.57) and it declined with tree height. We also used the allometric relationship between field-based measurements of soil-to-leaf hydraulic conductance and laboratory-based measurements of leaf hydraulic conductance to compute the average fR leaf for 19 tree samples, which was 0.40 (95% CI = 0.29-0.56). The in-situ technique produces a more accurate descriptor of fR leaf because it accounts for dynamic leaf hydraulic conductance. Both approaches demonstrate the outsized role of leaves in controlling tree hydrodynamics. A larger fR leaf may play a role in protecting stems from loss of hydraulic conductance. Thus, the decline in fR leaf with tree height would contribute to greater drought vulnerability in taller trees and potentially to their observed disproportionate drought mortality.

54 ENVIRONMENTAL SCIENCES↗

Review—Drag Coefficients of Non-Spherical and Irregularly Shaped Particles

Abstract The knowledge of simple and relatively accurate closure equations for the drag coefficients of nonspherical particles is very important for Eulerian multiphase numerical codes that require such inputs for the solution of the momentum equation. However, the existing correlations for the drag coefficients are laden with high uncertainty, which propagates in the numerical results. This review paper examines critically the state of our knowledge of the drag coefficients of nonspherical particles starting with our understanding of the “size” and “shape” of particles. Lengthscales and other parameters that have been used to characterize sizes of nonspherical particles are presented. Shape factors and shape descriptors that have been used in past correlations are also presented together with an appraisal of their applicability. Several correlations that have been developed for the determination of the drag coefficients of nonspherical particles with regular and irregular shapes are also presented together with available information on their accuracy and applicability. Based on the review of the available correlations general recommendations are offered on the use of the correlations as closure equations and inputs in computatioal fluid dynamics (CFD) codes.

Engineering↗

Spatial scaling metrics of mask-induced induced line-edge roughness

Mask contributors to line-edge roughness (LER) have recently been shown to be an issue of concern for both the accuracy of current resist evaluation tests as well the ultimate LER requirements for the 22-nm production node. Problems arise from mask absorber LER as well as mask reflector or surface roughness leading to random phase variations in the reflected beam. Not only do these mask contributors effect to total measured LER in resist, but they also effect LER spatial characteristic such as the LER power spectral density and related descriptors of correlation length and roughness exponent. Noting that these characteristics are important in the understanding of LER, it is crucial to understand how mask effects impact these parameters. Moreover, understanding how these metrics respond to mask effects may lead to an experimental mechanism for experimentally evaluating the importance of mask contributors to LER. Here we use computer modeling to study the LER spatial metrics arising from mask effects. We further describe the effects of illumination conditions and defocus on the metrics and compare the results to those expected from intrinsic resist LER.

36 MATERIALS SCIENCE↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The feasibility of a regional CTDI{sub vol} to estimate organ dose from tube current modulated CT exams

Purpose: In AAPM Task Group 204, the size-specific dose estimate (SSDE) was developed by providing size adjustment factors which are applied to the Computed Tomography (CT) standardized dose metric, CTDI{sub vol}. However, that work focused on fixed tube current scans and did not specifically address tube current modulation (TCM) scans, which are currently the majority of clinical scans performed. The purpose of this study was to extend the SSDE concept to account for TCM by investigating the feasibility of using anatomic and organ specific regions of scanner output to improve accuracy of dose estimates. Methods: Thirty-nine adult abdomen/pelvis and 32 chest scans from clinically indicated CT exams acquired on a multidetector CT using TCM were obtained with Institutional Review Board approval for generating voxelized models. Along with image data, raw projection data were obtained to extract TCM functions for use in Monte Carlo simulations. Patient size was calculated using the effective diameter described in TG 204. In addition, the scanner-reported CTDI{sub vol} (CTDI{sub vol,global}) was obtained for each patient, which is based on the average tube current across the entire scan. For the abdomen/pelvis scans, liver, spleen, and kidneys were manually segmented from the patient datasets; for the chest scans, lungs and for female models only, glandular breast tissue were segmented. For each patient organ doses were estimated using Monte Carlo Methods. To investigate the utility of regional measures of scanner output, regional and organ anatomic boundaries were identified from image data and used to calculate regional and organ-specific average tube current values. From these regional and organ-specific averages, CTDI{sub vol} values, referred to as regional and organ-specific CTDI{sub vol}, were calculated for each patient. Using an approach similar to TG 204, all CTDI{sub vol} values were used to normalize simulated organ doses; and the ability of each normalized dose to correlate with patient size was investigated. Results: For all five organs, the correlations with patient size increased when organ doses were normalized by regional and organ-specific CTDI{sub vol} values. For example, when estimating dose to the liver, CTDI{sub vol,global} yielded a R{sup 2} value of 0.26, which improved to 0.77 and 0.86, when using the regional and organ-specific CTDI{sub vol} for abdomen and liver, respectively. For breast dose, the global CTDI{sub vol} yielded a R{sup 2} value of 0.08, which improved to 0.58 and 0.83, when using the regional and organ-specific CTDI{sub vol} for chest and breasts, respectively. The R{sup 2} values also increased once the thoracic models were separated for the analysis into females and males, indicating differences between genders in this region not explained by a simple measure of effective diameter. Conclusions: This work demonstrated the utility of regional and organ-specific CTDI{sub vol} as normalization factors when using TCM. It was demonstrated that CTDI{sub vol,global} is not an effective normalization factor in TCM exams where attenuation (and therefore tube current) varies considerably throughout the scan, such as abdomen/pelvis and even thorax. These exams can be more accurately assessed for dose using regional CTDI{sub vol} descriptors that account for local variations in scanner output present when TCM is employed.

60 APPLIED LIFE SCIENCES↗

A support vector machine classifier reduces interscanner variation in the HRCT classification of regional disease pattern in diffuse lung disease: Comparison to a Bayesian classifier

Purpose: To investigate the effect of using different computed tomography (CT) scanners on the accuracy of high-resolution CT (HRCT) images in classifying regional disease patterns in patients with diffuse lung disease, support vector machine (SVM) and Bayesian classifiers were applied to multicenter data. Methods: Two experienced radiologists marked sets of 600 rectangular 20 Multiplication-Sign 20 pixel regions of interest (ROIs) on HRCT images obtained from two scanners (GE and Siemens), including 100 ROIs for each of local patterns of lungs-normal lung and five of regional pulmonary disease patterns (ground-glass opacity, reticular opacity, honeycombing, emphysema, and consolidation). Each ROI was assessed using 22 quantitative features belonging to one of the following descriptors: histogram, gradient, run-length, gray level co-occurrence matrix, low-attenuation area cluster, and top-hat transform. For automatic classification, a Bayesian classifier and a SVM classifier were compared under three different conditions. First, classification accuracies were estimated using data from each scanner. Next, data from the GE and Siemens scanners were used for training and testing, respectively, and vice versa. Finally, all ROI data were integrated regardless of the scanner type and were then trained and tested together. All experiments were performed based on forward feature selection and fivefold cross-validation with 20 repetitions. Results: For each scanner, better classification accuracies were achieved with the SVM classifier than the Bayesian classifier (92% and 82%, respectively, for the GE scanner; and 92% and 86%, respectively, for the Siemens scanner). The classification accuracies were 82%/72% for training with GE data and testing with Siemens data, and 79%/72% for the reverse. The use of training and test data obtained from the HRCT images of different scanners lowered the classification accuracy compared to the use of HRCT images from the same scanner. For integrated ROI data obtained from both scanners, the classification accuracies with the SVM and Bayesian classifiers were 92% and 77%, respectively. The selected features resulting from the classification process differed by scanner, with more features included for the classification of the integrated HRCT data than for the classification of the HRCT data from each scanner. For the integrated data, consisting of HRCT images of both scanners, the classification accuracy based on the SVM was statistically similar to the accuracy of the data obtained from each scanner. However, the classification accuracy of the integrated data using the Bayesian classifier was significantly lower than the classification accuracy of the ROI data of each scanner. Conclusions: The use of an integrated dataset along with a SVM classifier rather than a Bayesian classifier has benefits in terms of the classification accuracy of HRCT images acquired with more than one scanner. This finding is of relevance in studies involving large number of images, as is the case in a multicenter trial with different scanners.

60 APPLIED LIFE SCIENCES↗

Quality assurance of proton beams using a multilayer ionization chamber system

Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements.Conclusions: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural analysis of cortical porosity applied to HR-pQCT data

Purpose: The investigation of cortical porosity is an important aspect of understanding biological, pathoetiological, and biomechanical processes occurring within the skeleton. With the emergence of HR-pQCT as a noninvasive tool suitable for clinical use, cortical porosity at appendicular sites can be directly visualizedin vivo. The aim of this study was to introduce a novel topological analysis of the cortical pore network for HR-pQCT data and determine the influence of resolution on measures of cortical pore network microstructure and topology. Methods: Cadaveric radii were scanned using HR-pQCT at two different voxel sizes (41 and 82μm) and also using μCT at a voxel size of 18 μm. HR-pQCT and μCT image sets were spatially coregistered. Segmentation and quantification of cortical porosity (Ct.Po) and mean pore diameter (Ct.Po.Dm) were achieved using an established extended cortical analysis technique. Topological classification of individual pores was performed using topology-preserving skeletonization and multicolor dilation algorithms. Based on the pore skeleton topological classification, the following parameters were quantified: total number of planar surface-skeleton canals (N.Slabs), tubular curve-skeleton canals (N.Tubes), and junction elements (N.Junctions), mean slab volume (Slab.Vol), mean tube volume (Tube.Vol), mean slab orientation (Slab.θ), mean tube orientation (Tube.θ), N.Slabs/N.Tubes, and integral (total) slab volume/integral tube volume (iSlab.Vol/iTube.Vol). An in vivo reproducibility study was also conducted to assess short-term precision of the topology parameters. Precision error was characterized using root mean square coefficient of variation (RMSCV%). Results: Correlations toμCT values for Ct.Po were significant for both the 41 and 82 μm HR-pQCT data (41: r{sup 2} = 0.82, p < 0.001, 82: r{sup 2} = 0.75, p < 0.001). For Ct.Po.Dm, only the 41 μm data were significantly predictive of μCT values (r{sup 2} = 0.72, p < 0.01) Data at both HR-pQCT voxel sizes were strongly predictive of the μCT values for N.Slabs (41: r{sup 2} = 0.93, p < 0.001; 82: r{sup 2} = 0.84, p < 0.001), N.Tubes (41: r{sup 2} = 0.94, p < 0.001; 82: r{sup 2} = 0.84, p < 0.001), and N.Junctions (41: r{sup 2} = 0.93, p < 0.001; 82: r{sup 2} = 0.78, p < 0.001), though proportional bias was evident in these correlations. Weak correlations were seen for iSlab.Vol/iTube.Vol at both voxel sizes (41: r{sup 2} = 0.52, p < 0.01; 82: r{sup 2} = 0.39, p < 0.05). Slab.Vol was significantly correlated to μCT data at 41 μm (r{sup 2} = 0.60, p < 0.01) but not at 82 μm, while Tube.Vol was significantly correlated at both voxel sizes (41: r{sup 2} = 0.79, p < 0.001; 82: r{sup 2} = 0.68, p < 0.01). In vivo precision error for these parameters ranged from 2.31 to 9.68 RMSCV%. Conclusions: Strong correlations betweenμCT- and HR-pQCT-derived measurements were found, particularly in HR-pQCT images obtained at 41 μm. These data are in agreement with our previous study investigating the effect of voxel size on standard HR-pQCT metrics of trabecular and cortical microstructure, and extend our previous findings to include topological descriptors of the cortical pore network.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-18A-05: Assessing Elekta MLC Tracking Performance

Purpose: To investigate the technical feasibility of using Elekta MLCs in tracked radiotherapy, specifically to show the capability of an Agility MLC to follow model tumor trajectories using object tracking. The system performance of the MLC is to be assessed via dosimetric experiments and temporal response measures. Methods: The system observer in the tracking cascade consisted of a camera serving for this proof of concept; Images of a moving object were acquired continuously and decorrelated for the position information, which was fed forward to the RT computer controlling the MLC via an interface provided by Elekta. The 1D motion (in the direction of the leaves) was induced by a CIRS motion controller. Additionally, the aperture position was observed by means of the light field of the linac. Calculating the phase between aperture and object yielded the mean aperture lag for the current setup. The object was restricted to sinusoidal motion with a period of 10s. For dosimetry, GafChromic radiosensitive film was irradiated with a total dose of 1000MU using an aperture size of 40mm and a motion range of 30mm. Results: Object tracking can substantially reconstruct the geometric dose response of a static target. In the dynamic case, dose is smeared out into the legs of the static distribution, leading to a reduced plateau and increased FWHM of 5mm, compared to the static width of 38mm. The time-lag between object and aperture was determined to be approximately 300ms for the current set-up. Conclusion: We demonstrated a tracking experiment performed on a clinical Elekta linear accelator for the first time. Observed profile variations show the dosimetric impact of tracked delivery. The determined lag is a valuable descriptor for a future tracking cascade employing predictor filters. The performed experiments are generic and possible predecessors for future applications with MR-Linac or ultrasound probes. Conflict of interest: this project is partly funded by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-20: A Review of Advanced PET and CT Image Features for the Evaluation of Tumor Response

Purpose: To review the literature in using quantitative PET and CT image features for the evaluation of tumor response. Methods: We reviewed and summarized more than fifty papers that use advanced, quantitative PET/CT image features for the evaluation of tumor response. We also discussed future works on extracting disease-specific features, combining multiple and complementary features in response modeling, delineating tumor in multimodality images, and exploring biological explanations of these advanced features. Results: Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features (characterizing spatial distribution of FDG uptake) have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Conclusions: Advanced, quantitative FDG PET/CT image features have been shown promising for the evaluation of tumor response. With the emerging multi-modality imaging performed at multiple time points for each patient, it becomes more important to analyze the serial images quantitatively, select and combine both complementary and contradictory information from various sources, for accurate and personalized evaluation of tumor response to therapy.

60 APPLIED LIFE SCIENCES↗

WE-A-18A-01: TG246 On Patient Dose From Diagnostic Radiation

Radiation dose from diagnostic and interventional radiations continues to be a focus of the regulatory, accreditation and standards organizations in the US and Europe. A Joint AAPM/EFOMP effort has been underway in the past year — having the goal to assist the clinical medical physicist with communicating optional and varied approaches in estimating (and validating) patient dose. In particular, the tools provided by DICOM Radiation Dose Structured Reports, either by themselves or as part of a networked data repository of dose related information are a rich source of actionable information. The tools of the medical physicist have evolved to include using DICOM data in meaningful ways to look at patient dose with respect to imaging practices. In addition to how accurate or reproducible a dose value is (totally necessary and our traditional workspace) it is now being asked how reproducible (patient to patient, device to device) are the delivered doses (new tasking)? Clinical medical physicists are best equipped to assist our radiology and technologist colleagues with this effort. The purpose of this session is to review the efforts of TG246 - bringing forward a summary content of the TG246 Report including specific dose descriptors for CT and Fluoroscopy — particularly in a focus of leveraging the RDSR as a means for monitoring good practices ALARA. Additionally, rapidly evolving technologies for more refined dose estimates are now in use. These will be presented as they look to having highly patient specific dose estimates in automated use.

60 APPLIED LIFE SCIENCES↗