Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIAMONDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Broadband, large-area microwave antenna for optically detected magnetic resonance of nitrogen-vacancy centers in diamond

We report on a microwave planar ring antenna specifically designed for optically detected magnetic resonance (ODMR) of nitrogen-vacancy (NV) centers in diamond. It has the resonance frequency at around 2.87 GHz with the bandwidth of 400 MHz, ensuring that ODMR can be observed under external magnetic fields up to 100 G without the need of adjustment of the resonance frequency. It is also spatially uniform within the 1-mm-diameter center hole, enabling the magnetic-field imaging in the wide spatial range. These features facilitate the experiments on quantum sensing and imaging using NV centers at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and delivery of the diamond double double bend achromat project

A major project is underway at Diamond Light Source to remove one of the 24 Double Bend Achromat (DBA) Storage Ring cells and replace it with a Double Double Bend Achromat (DDBA). In this way a new Insertion Device (ID) straight can be created and so ID light can be produced and delivered to a beamline previously only capable of receiving Bending Magnet (BM) radiation. This project is in support of the micro-focus Protein Crystallography (MX) beamline VMX-m which is scheduled to take users towards the end of 2017. This paper describes the Engineering Design of the DDBA project in more detail and gives the current status of the project.

43 PARTICLE ACCELERATORS↗

An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-energy focusing Laue monochromator for the diamond light source x-ray pair distribution function beamline I15-1

The I15-1 beamline, the new side station to I15 at the Diamond Light Source, will be dedicated to the collection of atomic pair distribution function data. A Laue monochromator will be used consisting of three silicon crystals diffracting X-rays at a common Bragg angle of 2.83°. The crystals use the (1 1 1), (2 2 0), and (3 1 1) planes to select 40, 65, and 76 keV X-rays, respectively, and will be bent meridionally to horizontally focus the selected X-rays onto the sample. All crystals will be cut to the same optimized asymmetry angle in order to eliminate image broadening from the crystal thickness. Finite element calculations show that the thermal distortion of the crystals will affect the image size and bandpass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focusing of white synchrotron radiation using large-acceptance cylindrical refractive lenses made of single – crystal diamond

Large-aperture cylindrical refractive lenses were manufactured by laser cutting of single-crystal diamond. Five linear single lenses with apertures of 1 mm and the depth of the structure of 1.2 mm were fabricated and tested at the ESRF ID06 beamline performing the focusing of white-beam synchrotron radiation. Uniform linear focus was stable during hours of exposure, representing such lenses as pre-focusing and collimating devices suitable for the front-end sections of today synchrotron radiation sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of multi-element monolithic germanium detectors for XAFS experiments at diamond light source

An overview of multi-element monolithic germanium detectors being used at the X-ray absorption spectroscopy (XAS) beam lines at Diamond Light Source (DLS) is being reported. The hardware details and a summary of the performance of these detectors have also been provided. Recent updates about various ongoing projects being worked on to improve the performance of these detectors are summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental evaluation of enhancement of diffraction efficiency by overcoating diamond-like carbon (DLC) on soft x-ray laminar-type gratings

Efficiently detecting the B-K emission band around 6.76 nm from a trace concentration of boron in steel compounds has motivated a theoretical exploration of means of increasing the diffraction efficiency of a laminar grating with carbon overcoating. To experimentally evaluate this enhancement, a Ni grating was coated with a high-density carbon film, i.e., diamond-like carbon (DLC). The first order diffraction efficiencies of the Ni gratings coated with and without DLC were measured to be 25.8 % and 16.9 %, respectively, at a wavelength of 6.76 nm and an angle of incidence of 87.07°. The ratio of diffraction efficiency obtained experimentally vs. that calculated by numerical simulation is 0.87 for the DLC-coated Ni grating. The diffraction efficiency of a Ni grating coated with a low-density carbon film, amorphous carbon (a-C), was also slightly improved to be 19.6 %. Furthermore, a distinct minimum of the zeroth order lights of the two carbon-coated Ni gratings were observed at around 6.76 nm, which is coincident with the maximum of the first order light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhancement of diffraction efficiency of laminar-type diffraction gratings overcoated with diamond-like carbon (DLC) in soft x-ray region

Boron is the critical trace element in the production of high quality steel, creating a great demand for an efficient detection method of the B-K emission band at around 6.76 nm. To meet this demand we made a simulation study and obtained a practical method to improve the diffraction efficiency of metal-coated laminar-type gratings for a grazing incidence flat-field spectrograph by overcoating a sufficiently transparent high-density material. In the simulation the diffraction efficiency in a spectral region of 3.5-8.5 nm was computed for several combinations of overcoating materials and coating metals, with various thicknesses of the overcoating layer. The result obtained are: (1) the best overcoating material is high-density diamond-like carbon (DLC) having a density of 3.1 g/cm{sup 3}, (2) its optimum thickness is 24 nm at an angle of incidence of 87.0°, and (3) with this thickness the first-order diffraction efficiency is expected to reach 29.7 %, which well exceeds 15.6 % for Ni-coated (or 14.1 % for Au-coated) grating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterising the large coherence length at diamond’s beamline I13L

I13 is a 250 m long hard x-ray beamline (6 keV to 35 keV) at the Diamond Light Source. The beamline comprises of two independent experimental endstations: one for imaging in direct space using x-ray microscopy and one for imaging in reciprocal space using coherent diffraction based imaging techniques [1]. An outstanding feature of the coherence branch, due to its length and a new generation of ultra-stable beamline instrumentation [2], is its capability of delivering a very large coherence length well beyond 200 μm, providing opportunities for unique x-ray optical experiments. In this paper we discuss the challenges of measuring a large coherence length and present quantitative measurement based on analyzing diffraction patterns from a boron fiber [3]. We also discuss the limitations of this classical method in respect to detector performance, very short and long coherence lengths. Furthermore we demonstrate how a Ronchi grating setup [4] can be used to quickly establish if the beam is coherent over a large area.

43 PARTICLE ACCELERATORS↗

Synthesis of flat sticky hydrophobic carbon diamond-like films using atmospheric pressure Ar/CH{sub 4} dielectric barrier discharge

An Ar/CH{sub 4} atmospheric pressure dielectric barrier discharge (AP-DBD) was used to synthesize sticky hydrophobic diamond-like carbon (DLC) films on glass surface. The film is formed with plasma treatment duration shorter than 30 s, and water contact angles larger than 90° together with contact angle hysteresis larger than 10° can be achieved. According to Fourier transform infrared spectroscopy and atomic force microscopy analysis, hydrocarbon functional groups are created on the glass substrate, producing coatings with low surface energy (∼35 mJ m{sup −2}) with no modification of the surface roughness. To infer the plasma processes leading to the formation of low energy DLC surfaces, optical emission spectroscopy was used. From the results, a direct relationship between the CH species present in the plasma and the carbon concentration in the hydrophobic layer was found, which suggests that the CH species are the precursors of DLC film growth. Additionally, the plasma gas temperature was measured to be below 350 K which highlights the suitability of using AP-DBD to treat thermo-sensitive surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diamond magnetometry of Meissner currents in a superconducting film

We study magnetic field penetration into a thin film made of a superconducting niobium. Imaging of magnetic field is performed by optically detecting magnetic resonances of negatively charged nitrogen-vacancy defects inside a single crystal diamond, which is attached to the niobium film under study. The experimental results are compared with theoretical predictions based on the critical state model, and good agreement is obtained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity of chemical vapor deposition diamonds to DD and DT neutrons at OMEGA and the National Ignition Facility

The particle-time-of-flight (pTOF) detector at the National Ignition Facility (NIF) is used routinely to measure nuclear bang-times in inertial confinement fusion implosions. The active detector medium in pTOF is a chemical vapor deposition diamond. Calibration of the detectors sensitivity to neutrons and protons would allow measurement of nuclear bang times and hot spot areal density (ρR) on a single diagnostic. This study utilizes data collected at both NIF and Omega in an attempt to determine pTOF’s absolute sensitivity to neutrons. At Omega pTOF’s sensitivity to DT-n is found to be stable to within 8% at different bias voltages. At the NIF pTOF’s sensitivity to DD-n varies by up to 59%. This variability must be decreased substantially for pTOF to function as a neutron yield detector at the NIF. As a result, some possible causes of this variability are ruled out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron emission spectroscopy of DT plasmas at enhanced energy resolution with diamond detectors

This work presents measurements done at the Peking University Van de Graaff neutron source of the response of single crystal synthetic diamond (SD) detectors to quasi-monoenergetic neutrons of 14-20 MeV. The results show an energy resolution of 1% for incoming 20 MeV neutrons, which, together with 1% detection efficiency, opens up to new prospects for fast ion physics studies in high performance nuclear fusion devices such as SD neutron spectrometry of deuterium-tritium plasmas heated by neutral beam injection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response function of single crystal synthetic diamond detectors to 1-4 MeV neutrons for spectroscopy of D plasmas

A Single-crystal Diamond (SD) detector prototype was installed at Joint European Torus (JET) in 2013 and the achieved results have shown its spectroscopic capability of measuring 2.5 MeV neutrons from deuterium plasmas. This paper presents measurements of the SD response function to monoenergetic neutrons, which is a key point for the development of a neutron spectrometer based on SDs and compares them with Monte Carlo simulations. The analysis procedure allows for a good reconstruction of the experimental results. The good pulse height energy resolution (equivalent FWHM of 80 keV at 2.5 MeV), gain stability, insensitivity to magnetic field, and compact size make SDs attractive as compact neutron spectrometers of high flux deuterium plasmas, such as for instance those needed for the ITER neutron camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimode scanning X-ray diffraction microscopy for diamond anvil cell experiments

We have designed and implemented a new experimental system for fast mapping of crystal structures and other structural features of materials under high pressure at the High Pressure Collaborative Access Team, Sector 16 of the Advanced Photon Source. The system utilizes scanning X-ray diffraction microscopy (SXDM) and is optimized for use with diamond anvil cell devices. In SXDM, the X-ray diffraction (XRD) is collected in a forward scattering geometry from points on a two-dimensional grid by fly-scanning the sample with respect to a micro-focused X-ray beam. The recording of XRD is made during the continuous motion of the sample using a fast (millisecond) X-ray area detector in synchrony with the sample positioners, resulting in a highly efficient data collection for SXDM. A new computer program, X-ray Diffractive Imaging (XDI), has been developed with the SXDM system. The XDI program provides a graphical interface for constructing and displaying the SXDM images in several modes: (1) phase mapping based on structural information, (2) pressure visualization based on the equation of state, (3) microstructural features mapping based on peak shape parameters, and (4) grain size and preferred-orientation based on peak shape parameters. The XDI is a standalone program and can be generally used for displaying SXDM images. Two examples of iron and zirconium samples under high pressure are presented to demonstrate the applications of SXDM. Published under license by AIP Publishing.

47 OTHER INSTRUMENTATION↗

Mean transverse energy of ultrananocrystalline diamond photocathode

Nitrogen incorporated ultrananocrystalline diamond [(N)UNCD] could be an enabling material platform for injector photocathode applications due to its high emissivity. While the quantum efficiency (QE) of UNCD was reported by many groups, no experimental measurements of the intrinsic emittance/mean transverse energy (MTE) have been reported. Here, MTE measurement results for an (N)UNCD photocathode in the photon energy range from 4.41 to 5.26 eV are described. The MTE demonstrates no noticeable dependence on the photon energy, with an average value of 266 meV. This spectral behavior is shown not to be dependent upon physical or chemical surface roughness and inconsistent with low electron effective mass emission from graphitic grain boundaries but may be associated with emission from spatially confined states in the grain boundaries. Lastly, the combined effect of low and constant MTE and high QE, which increases with respect to the excess laser energy, may pave the way for bright UNCD photocathodes for electron injectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An improved setup for radial diffraction experiments at high pressures and high temperatures in a resistive graphite-heated diamond anvil cell

We present an improved setup for the experimental study of deformation of solids at simultaneous high pressures and temperatures by radial x-ray diffraction. This technique employs a graphite resistive heated Mao–Bell type diamond anvil cell for radial x-ray diffraction in combination with a water-cooled vacuum chamber. The new chamber has been developed by the sample environment group at PETRA III and implemented at the Extreme Conditions Beamline P02.2 at PETRA III, DESY (Hamburg, Germany). Here, we discuss applications of the new setup to study deformation of a variety of materials, including ferropericlase, calcium perovskite, bridgmanite, and tantalum carbide, at high-pressure/temperature.

47 OTHER INSTRUMENTATION↗

Direct formation of nitrogen-vacancy centers in nitrogen doped diamond along the trajectories of swift heavy ions

We report depth-resolved photoluminescence measurements of nitrogen-vacancy (NV$^-$) centers formed along the tracks of swift heavy ions in type Ib synthetic single crystal diamonds that had been doped with 100 ppm nitrogen during crystal growth. Analysis of the spectra shows that NV$^-$ centers are formed preferentially within regions where electronic stopping processes dominate and not at the end of the ion range where elastic collisions lead to formation of vacancies and defects. Thermal annealing further increases NV yields after irradiation with SHI preferentially in regions with high vacancy densities. NV centers formed along the tracks of single swift heavy ions can be isolated with lift-out techniques for explorations of color center qubits in quasi 1D registers with average qubit spacing of a few nm and of order 100 color centers per micron along 10 to 30 micron long percolation chains.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗