Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computed Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Error-mitigated nonorthogonal quantum eigensolver via shadow tomography

We present a shadow-tomography-enhanced nonorthogonal quantum eigensolver (NOQE) for more efficient and accurate electronic structure calculations on near-term quantum devices. By integrating shadow tomography into the NOQE, the measurement cost scales linearly rather than quadratically with the number of reference states, while also reducing the required qubits and circuit depth by half. This approach enables extraction of all matrix elements via randomized measurements and classical postprocessing. We analyze its sample complexity and show that, for small systems, it remains constant in the high-precision regime, while for larger systems, it scales linearly with the system size. We further apply shadow-based error mitigation to suppress noise-induced bias without increasing quantum resources. Demonstrations on the hydrogen molecule in the strongly correlated regime achieve chemical accuracy under realistic noise, showing that our method is both resource-efficient and noise-resilient for practical quantum chemistry simulations in the near term.

quantum algorithms & computation↗

Universal framework for simultaneous tomography of quantum states and SPAM noise

We present a general denoising algorithm for performing simultaneous tomography of quantum states and measurement noise. This algorithm allows us to fully characterize state preparation and measurement (SPAM) errors present in any quantum system. Our method is based on the analysis of the properties of the linear operator space induced by unitary operations. Given any quantum system with a noisy measurement apparatus, our method can output the quantum state and the noise matrix of the detector up to a single gauge degree of freedom. We show that this gauge freedom is unavoidable in the general case, but this degeneracy can be generally broken using prior knowledge on the state or noise properties, thus fixing the gauge for several types of state-noise combinations with no assumptions about noise strength. Such combinations include pure quantum states with arbitrarily correlated errors, and arbitrary states with block independent errors. This framework can further use available prior information about the setting to systematically reduce the number of observations and measurements required for state and noise detection. Our method effectively generalizes existing approaches to the problem, and includes as special cases common settings considered in the literature requiring an uncorrelated or invertible noise matrix, or specific probe states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scientific Computational Imaging Code (SCICO)

Scientific Computational Imaging Code (SCICO) is a Python package for solving the inverse problems that arise in scientific imaging applications. Its primary focus is providing methods for solving ill-posed inverse problems by using an appropriate prior model of the reconstruction space. SCICO includes a growing suite of operators, cost functionals, regularizers, and optimization routines that may be combined to solve a wide range of problems, and is designed so that it is easy to add new building blocks. SCICO is built on top of JAX rather than NumPy, enabling GPU/TPU acceleration, just-in-time compilation, and automatic gradient functionality, which is used to automatically compute the adjoints of linear operators. An example of how to solve a multi-channel tomography problem with SCICO is shown in Figure 1. The SCICO source code is available from GitHub, and pre-built packages are available from PyPI. It has extensive online documentation, including API documentation and usage examples, which can be run online at Google Colab and binder.

97 MATHEMATICS AND COMPUTING↗

Global centroid moment tensor solutions in a heterogeneous earth: the CMT3D catalogue

SUMMARY For over 40 yr, the global centroid-moment tensor (GCMT) project has determined location and source parameters for globally recorded earthquakes larger than magnitude 5.0. The GCMT database remains a trusted staple for the geophysical community. Its point-source moment-tensor solutions are the result of inversions that model long-period observed seismic waveforms via normal-mode summation for a 1-D reference earth model, augmented by path corrections to capture 3-D variations in surface wave phase speeds, and to account for crustal structure. While this methodology remains essentially unchanged for the ongoing GCMT catalogue, source inversions based on waveform modelling in low-resolution 3-D earth models have revealed small but persistent biases in the standard modelling approach. Keeping pace with the increased capacity and demands of global tomography requires a revised catalogue of centroid-moment tensors (CMT), automatically and reproducibly computed using Green's functions from a state-of-the-art 3-D earth model. In this paper, we modify the current procedure for the full-waveform inversion of seismic traces for the six moment-tensor parameters, centroid latitude, longitude, depth and centroid time of global earthquakes. We take the GCMT solutions as a point of departure but update them to account for the effects of a heterogeneous earth, using the global 3-D wave speed model GLAD-M25. We generate synthetic seismograms from Green's functions computed by the spectral-element method in the 3-D model, select observed seismic data and remove their instrument response, process synthetic and observed data, select segments of observed and synthetic data based on similarity, and invert for new model parameters of the earthquake’s centroid location, time and moment tensor. The events in our new, preliminary database containing 9382 global event solutions, called CMT3D for ‘3-D centroid-moment tensors’, are on average 4 km shallower, about 1 s earlier, about 5 per cent larger in scalar moment, and more double-couple in nature than in the GCMT catalogue. We discuss in detail the geographical and statistical distributions of the updated solutions, and place them in the context of earlier work. We plan to disseminate our CMT3D solutions via the online ShakeMovie platform.

58 GEOSCIENCES↗

TomoGAN: low-dose synchrotron x-ray tomography with generative adversarial networks: discussion

Synchrotron-based x-ray tomography is a noninvasive imaging technique that allows for reconstructing the internal structure of materials at high spatial resolutions from tens of micrometers to a few nanometers. In order to resolve sample features at smaller length scales, however, a higher radiation dose is required. Therefore, the limitation on the achievable resolution is set primarily by noise at these length scales. We present TomoGAN, a denoising technique based on generative adversarial networks, for improving the quality of reconstructed images for low-dose imaging conditions. We evaluate our approach in two photon-budget-limited experimental conditions: (1) sufficient number of low-dose projections (based on Nyquist sampling), and (2) insufficient or limited number of high-dose projections. In both cases, the angular sampling is assumed to be isotropic, and the photon budget throughout the experiment is fixed based on the maximum allowable radiation dose on the sample. Evaluation with both simulated and experimental datasets shows that our approach can significantly reduce noise in reconstructed images, improving the structural similarity score of simulation and experimental data from 0.18 to 0.9 and from 0.18 to 0.41, respectively. Furthermore, the quality of the reconstructed images with filtered back projection followed by our denoising approach exceeds that of reconstructions with the simultaneous iterative reconstruction technique, showing the computational superiority of our approach.

42 ENGINEERING↗

Entanglement Benchmarking in Quantum Simulations of Spin Systems

We simulate quantum spin systems and measure entanglement using circuits tailored for near-term quantum computers. Traditional tools like entanglement entropy are limited to pure states and require full state tomography, making them impractical on current hardware. Instead, we employ the novel approach, Positive Partial Transpose (PPT) criterion to efficiently detect pairwise entanglement from two-spin reduced density matrices, applicable to both pure and mixed states. This method enables scalable entanglement detection, providing a practical route to study quantum correlations, phase transitions, and benchmark quantum devices.

Baul, Anshumitra [ORNL] (ORCID:0000000268947191)↗

Improving reproducibility in synchrotron tomography using implementation-adapted filters

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A High-Speed Rotational Diamond Anvil Cell for In Situ Analysis of Hierarchical Microstructural Evolution of Metallic Alloys during Extreme Shear Deformation

High speed shear deformation is ubiquitous in engineering applications, ranging from material processing methods such as friction stir processing/extrusion and in tribological contacts. However, analyzing the microstructural evolution of materials while they are undergoing high speed shear deformation have been a long-standing challenge. This led to predominant reliance on ex situ microscopy before and after shear deformation. But ex situ microscopy lacks the ability to analyze dynamic and transient hierarchical microstructural evolution mechanisms that could occur during shear deformation of materials. Therefore, to better understand the dynamic mechanisms of mass and energy transfer in materials under shear deformation, we developed a first of its kind high-speed rotational diamond anvil cell (HS-RDAC) for synchrotron-based in situ high-energy x-ray diffraction (XRD). We studied the time resolved lattice strain evolution, XRD peak broadening and changes in spatial variation of shear deformation induced alloying in pure metal and metal alloy sheets and powder mixture using the HS-RDAC. These in situ results were combined with detailed ex situ microstructural characterization before and after the shear deformation using transmission electron microscopy and atom probe tomography, which revealed the different stages of evolution of a shear deformation induced hierarchical nanostructure. Multiscale computational simulations including computational fluid dynamics, crystal plasticity, molecular dynamic simulation and density functional theory uncovered the mechanisms behind morphological changes, evolution of defect structures and changes in driving force for shear deformation induced intermixing. In conclusion, this in situ HS-RDAC capability, in combination with ex situ microstructural characterization and computational simulations, can provide new insights into the hierarchical microstructural evolution pathway during shear deformation.

36 MATERIALS SCIENCE↗

Focused Ion Beam Tomography of Alloy 617 Corroded in Molten Chloride Salt

Materials qualification of reactor structural materials is a critical step in rapid implementation of advanced nuclear reactor technologies, particularly to assess the corrosion performance in these designs. Accelerated qualification of reactor structural materials requires incorporating powerful computational toolsets, such as phase field modelling in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, to predict the evolution of structural materials due to corrosion. Accordingly, computational toolsets will require experimental data generated at appropriate length scales to validate accuracy. Focused ion beam (FIB) provides a high degree of control over manipulation of materials for analytical purposes, including capturing data on the evolution in the microstructure and elemental composition of materials at the mesoscale, an appropriate length scale for phase field modelling of intergranular diffusion phenomena using the MOOSE framework. For instance, the FEI Helios G4 UX dual beam plasma FIB microscope at the Irradiated Materials Characterization Laboratory (IMCL) is capable of backscatter diffraction (EBSD) and energy-dispersive x-ray spectroscopy (EDS) documenting the evolution in the microstructure and elemental composition, respectively. The Helios can perform EDS and EBSD three-dimensionally (3D) using tomography, which is then combined using different software packages to visualize 3D volumes correlating elemental composition to microstructural data. The purpose of this investigation was to develop a streamlined characterization and data processing workflow for 3D tomography studies on the FEI Helios G4 plasma FIB. The investigation is segmented into three parts: 1) Optimizing the data collection workflow, 2) identifying appropriate data processing and visualization software (i.e. DREAM.3D, MIPAR, and VGStudioMax), and 3) establishing an infrastructure for public release. The optimization of the data collection workflow is in collaboration with members of the U220 department to setup formal training on the tomography operation of the G4, through ThermoFisher Scientific, and exploring DREAM.3D, MIPAR, and VGStudioMax data processing/visualization software packages. VGStudioMax currently demonstrates the most promise for future use. Optimization of the data collection and processing workflow is still ongoing. A collaboration with INL High Performance Computing (HPC) established an open-source license for expediting the public release of FIB tomography datasets through HPC. FIB tomography data generated by the G4 will provide comprehensive data for validating 3D phase field mesoscale modelling tools within the MOOSE framework for accelerated qualification of reactor structural materials.

Copeland-Johnson, Trishelle↗

Poisson-response Tensor-on-Tensor Regression and Applications

We introduce Poisson-response tensor-on-tensor regression (PToTR), a novel regression framework designed to handle tensor responses composed element-wise of random Poisson-distributed counts. Tensors, or multi-dimensional arrays, composed of counts are common data in fields such as inter national relations, social networks, epidemiology, and medical imaging, where events occur across multiple dimensions like time, location, and dyads. PToTR accommodates such tensor responses alongside tensor covariates, providing a versatile tool for multi dimensional data analysis. We propose algorithms for maximum likelihood estimation under a canonical polyadic (CP) structure on the regression coefficient tensor that satisfy the positivity of Poisson parameters and then provide an initial theoretical error analysis for PToTR estimators. We also demonstrate the utility of PToTR through three concrete applications: longitudinal data analysis of the Integrated Crisis Early Warning System database, positron emission tomography (PET) image reconstruction, and change-point detection of communication patterns in longitudinal dyadic data. These applications highlight the versatility of PToTR in addressing complex, structured count data across various domains.

97 MATHEMATICS AND COMPUTING↗

Atomic-scale identification of active sites of oxygen reduction nanocatalysts

Heterogeneous nanocatalysts play a crucial role in both the chemical and energy industries. Despite substantial advancements in theoretical, computational and experimental studies, identifying their active sites remains a major challenge. Here we utilize atomic electron tomography to determine the three-dimensional atomic structure of PtNi and Mo-doped PtNi nanocatalysts for the electrochemical oxygen reduction reaction. We then employ the experimental atomic structures as input to first-principles-trained machine learning to identify the active sites of the nanocatalysts. Through the analysis of the structure–activity relationships, we formulate an equation termed the local environment descriptor, which balances the strain and ligand effects to provide physical and chemical insights into active sites in the oxygen reduction reaction. The ability to determine the three-dimensional atomic structure and chemical composition of realistic nanoparticles, combined with machine learning, could transform our fundamental understanding of the active sites of catalysts and guide the rational design of optimal nanocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PFLOTRAN 5

PFLOTRAN leverages massively parallel, high performance computing to simulate large-scale non-isothermal multiphase flow, multicomponent reactive transport and electrical resistivity tomography (ERT) problems in the subsurface environment. Researchers have employed PFLOTRAN to simulate these Earth system processes on leadership class supercomputers for over two decades. The code is designed to predict the future estate of environmental systems and better inform stakeholders in the regulatory decision making process (e.g., fate of contaminants, long-term stewardship for nuclear waste, impact of climate change, etc.). A diverse team of scientists oversees PFLOTRAN development and maintenance under an open-source licensing agreement and manages contributions from an international community of researchers.

Hammond, Glenn↗

Observable measurement-induced transitions

One of the main postulates of quantum mechanics is that measurements destroy quantum coherence (wave function collapse). Recently it was discovered that in a many-body system dilute local measurements still preserve some coherence across the entire system. As the measurement density is increased, a phase transition occurs that is characterized by the disentanglement of different parts of the system. Unfortunately, this transition is impossible to observe experimentally for macroscopic systems because it requires an exponentially costly full tomography of the many-body wave function or a comparison with the simulation on an oracle classical computer. In this work we report the discovery of another measurement-induced phase transition that can be observed experimentally if quantum dynamics can be reversed. On one side of this phase transition the quantum information encoded in some part of the Hilbert space is fully recovered after the time inversion. On the other side, all quantum information is corrupted. This transition also manifests itself as the change in the behavior of the probability to observe the same measurement outcome in the process that consists of identical blocks repeated many times. In each block the unitary evolution is followed by the measurement. On one side of the transition the probability decreases exponentially with the number of repetitions, on the other it tends to a constant as the number of repetitions is increased. We confirm the existence of the proposed phase transition through numerical simulations of realistic quantum circuits and analytical calculations using an effective random-matrix theory model.

Measurement-induced phase transitions↗

Attention-based quantum tomography

Abstract With rapid progress across platforms for quantum systems, the problem of many-body quantum state reconstruction for noisy quantum states becomes an important challenge. There has been a growing interest in approaching the problem of quantum state reconstruction using generative neural network models. Here we propose the ‘attention-based quantum tomography’ (AQT), a quantum state reconstruction using an attention mechanism-based generative network that learns the mixed state density matrix of a noisy quantum state. AQT is based on the model proposed in ‘Attention is all you need’ by Vaswani et al (2017 NIPS ) that is designed to learn long-range correlations in natural language sentences and thereby outperform previous natural language processing (NLP) models. We demonstrate not only that AQT outperforms earlier neural-network-based quantum state reconstruction on identical tasks but that AQT can accurately reconstruct the density matrix associated with a noisy quantum state experimentally realized in an IBMQ quantum computer. We speculate the success of the AQT stems from its ability to model quantum entanglement across the entire quantum system much as the attention model for NLP captures the correlations among words in a sentence.

97 MATHEMATICS AND COMPUTING↗

Deep learning enables nanoscale X-ray 3D imaging with limited data

Deep neural network can greatly improve tomography reconstruction with limited data. A recent effort of combining ptycho-tomography model with the 3D U-net demonstrated a significant reduction in both the number of projections and computation time, and showed its potential for integrated circuit imaging that requires high-resolution and fast measurement speed.

47 OTHER INSTRUMENTATION↗