Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSION TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗

Performance of Nb3Sn Quadrupole Under High Stress

Future upgrades of the Large Hadron Collider (LHC) will require large aperture and high gradient quadrupoles. Nb{sub 3}Sn is the most viable option for this application but is also known for its strain sensitivity. In high field magnets, with magnetic fields above 12 T, the Lorentz forces will generate mechanical stresses that may exceed 200 MPa in the windings. The existing measurements of critical current versus strain of Nb{sub 3}Sn strands or cables are not easily applicable to magnets. In order to investigate the impact of high mechanical stress on the quench performance, a series of tests was carried out within a LBNL/CERN collaboration using the magnet TQS03 (a LHC Accelerator Research Program (LARP) 1-meter long, 90-mm aperture Nb{sub 3}Sn quadrupole). The magnet was tested four times at CERN under various pre-stress conditions. The average mechanical compressive azimuthal pre-stress on the coil at 4.2 K ranged from 120 MPa to 200 MPa. This paper reports on the magnet performance during the four tests focusing on the relation between pre-stress conditions and the training plateau.

43 PARTICLE ACCELERATORS↗

Laboratory Test Report for Six ENERGY STAR Dehumidifiers

This report documents the measured performance of six residential ENERGY STAR vapor compression dehumidifiers. The performance of each was measured over a wide range of inlet air conditions and fit to a numerical model for capacity and efficiency. Performance curves were developed for use in EnergyPlus. Test data from all six dehumidifiers were also fit to generic performance curves. This work can be used by energy modelers and equipment manufacturers to understand how current products will operate in a wide range of environments, and to develop advanced space conditioning systems for efficient, safe, durable and healthy homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical Characterization of Electrolyzer Membranes and Components Under Compression

Proton-exchange membrane (PEM) water electrolysis is a promising technology for producing clean hydrogen by electrochemically splitting water when paired with renewable energy sources. A major roadblock to improving electrolyzer durability is the mechanical degradation of the cell components, which requires an understanding of their mechanical response under device-relevant conditions. However, there is a lack of studies on the mechanical characterization of the PEM and other components, as well as and their interactions. This study aims to address this gap by using a custom-designed testing apparatus to investigate the mechanics of electrolyzer components in uniaxial compression at 25 and 80 °C. Findings show stress-strain response of components have a varying degree of nonlinearity owing to their distinct deformation mechanisms and morphologies, from porous structures to polymers. These results are used to develop an expression for compressive stress-strain response of Nafion membranes and then analyze the deformation of components under applied pressure by using a 1-D spring network model of cell assembly. This work provides a new understanding of mechanical responses of the electrolyzer membrane and cell components, which can help assess material design and cell assembly strategies for improved electrolyzer durability.

08 HYDROGEN↗

Development of a High-Pressure Fuel Injection System for Use with Propane-DME

Paper details the design approach and performance of a high-pressure common rail fuel injection system used with Propane-DME mixtures targeting high injection pressures on a light duty 2.2L inline-4 compression ignition engine. The study estimates the bulk modulus of elasticity based on the hardware geometry and operating pressures to assess the compressibility of Propane and DME across a range of pressures typical of the LD engine application. The compressibility factor ranges from 500 to 3000 bar, significantly lower than the theoretical values for the conditions tested. The high-pressure pump performance is optimized via the implementation of an inlet metering valve operated on a crank-angle open/close sequence to control pressure at the common rail. The application of a model-based controller and the use of high-speed sampling of rail pressure indicate that pressure at the rail can be attained with the pump metering valve, and without use of the pressure relieve valve present in the rail. Results show a significant reduction on pumping work parasitics and of fuel heating, on the order of 40°C, at typical working conditions with the proposed approach. Injector rates of injection with Propane-DME are very similar to those of Diesel. Paper compares bench data of rates of injection versus simulation predictions across operating pressures of 200 to 1000bar and from injection commands spanning 0.20 to 2.0ms. Furthermore, the accuracy of the model predictions are attributed in part by to the updated fuel compressibility modulus descriptions attained during the testing.

42 ENGINEERING↗

IMPLEMENTING PRIMARY CREEP CALCULATIONS DURING STRESS CHANGES AND REVERSALS IN THE FUEL PERFORMANCE CODE FRAPCON-3

Recently, the creep models in FRAPCON-3.4 were used to model the creep tests performed in IFA-699 up through cycle 4. IFA-699 is an instrumented test rig in the Halden Boiling Water Reactor that is being used to perform in-reactor creep experiments under changing stress conditions. The cladding creep tests in IFA-699 were on four fresh fuel segments with Zircaloy-4, E110, M-MDA, and M5™ cladding. These fuel segments were loaded in a test rig and placed in a PWR loop and operated under PWR conditions. Each of the test fuel rods were connected to gas lines in order to apply tensile and compressive stresses to the cladding. Diameters of the cladding were measured by diameter gages at several intervals to measure the creep behavior of the cladding as a function of time. The creep tests were performed at a temperature of around 360°C and fast neutron flux of 1.8 to 2.4×1017 n/m²-s (depends on specimen location). During the four cycles of operation, hoop stresses of -75, -50, +30, and +110 MPa were applied to the specimens. In addition to providing assessment of the FRAPCON-3.4 creep modeling, the creep model comparisons were also used to provide insight into the nature of primary creep following stress changes, whether creep behavior is symmetric under tensile and compressive loading, and the effect of fast fluence on creep rate. It was determined that creep strain should be calculated as a function of effective stress rather than hoop stress. This accounts for the observed difference between creep under compressive and tensile stress for the same hoop stress. It was also determined that the primary creep changes in proportion to the change in stress following stress change or stress reversal. Finally, it was observed that the irradiation creep rate decreases somewhat with increasing fluence. The creep model in FRAPCON-3.4 has already been developed to be a function of effective stress and includes a term that decreases the irradiation creep rate with increasing fluence. A new mathematical formulation has been developed that is suitable for a fuel performance code to calculate the primary creep strain under conditions of changing stress and stress reversal. The creep model in FRAPCON-3.4 and the formulation for calculating primary creep under changing stress conditions will be described in this paper. Comparisons to data will also be provided.

Geelhood, Kenneth J.↗

Advancement of Commercial Intumescent Expanding Foams for Deactivation and Decommissioning in the Nuclear Sector - 20198

Florida International University (FIU), in collaboration with The Department of Energy's Office of Environmental Management (DOE-EM), Savannah River National Laboratory (SRNL), and sites across the Savannah River complex, have identified an operational requirement for a fixative technology that is intended to immobilize and/or isolate residual contamination within a 3-dimensional space. Fixation of radiological contamination can reduce worker risk and mitigate potentially hazardous conditions, however nearly every marketed contamination fixative has been found to be flammable; a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular geometry or areas that are difficult to access whilst ensuring full coverage. The technical evaluation and advancement of commercial-off-the-shelf (COTS) polyurethane foams has yielded a down-selected candidate that shows potential in meeting the requirements to support deactivation and decommissioning activities. Several performance criteria have been established and tested to progress the technology readiness level towards an active field demonstration (TRL-7). Such criteria include: mechanical failure limits, adhesive and cohesive properties, thermal/fire resilience, determining thermal behavior, ability to immobilize contamination, and a means of non-destructive evaluation of applications. The test scenario examined was targeted towards an application for decommissioning nuclear pipework, in which the down-selected polyurethane foam would act as a barrier to segregate pipework and mitigate the potential for release during cutting, packaging, and storage operations. Testing carried out at SRNL included: mechanical evaluation of tensile, compressive, and adhesion strength by dynamic mechanical analysis (DMA), as well as thermogravimetric analysis (TGA). FIU examined the foam's fixative properties by utilizing phosphorescent europium-dysprosium doped strontium aluminate powder to investigating the extent to which contamination can be immobilized. FIU has also exploited previous successes in the field of intumescent technologies to assess the down-selected foam's tolerance to an extreme fire scenario, while maintaining the ability to effectively mitigate a contamination release. Parallel to this, extensive thermal investigations were carried out to determine the upper boundary of anticipated heat generation during the curing process as heat generation has the potential to compromise rubber parts of contaminated enclosures. These investigations subsequently yielded a promising method for a non-destructive application evaluation by means of infrared thermography. Utilizing the high sensitivity of modern IR cameras, coupled with the heat generated during the curing process of the polyurethane foam, FIU has been exploring the concept of monitoring the external pipe surface for indications of an irregular or abnormal application, thus informing operational decision making. The testing carried out utilized several current 'best fit' ASTM standards, which serve as helpful guidelines for testing, however, a precise definition of the operational parameters and requirements is still necessary. With continued collaboration with SRNL, FIU aims refine said definitions and develop new standards by which this, and other decommissioning technologies, can be accredited by relevant standards based testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Temperature Effect on the Compressive Behavior of Closed-Cell Aluminum-Alloy Foams

In this research, the mechanical behavior of closed-cell aluminum (Al)-alloy foams was investigated at different temperatures in the range of 25-450 °C. The main mechanical properties of porous Al-alloy foams are affected by the testing temperature, and they decrease with the increase in the temperature during uniaxial compression. From both the constant/serrated character of stress–strain curves and macro/microstructural morphology of deformed cellular structure, it was found that Al foams present a transition temperature from brittle to ductile behavior around 192 °C. Due to the softening of the cellular structure at higher temperatures, linear correlations of the stress amplitude and that of the absorbed energy with the temperature were proposed. Also, it was observed that the presence of inherent defects like micropores in the foam cell walls induced further local stress concentration which weakens the cellular structure’s strength and crack propagation and cell-wall plastic deformation are the dominant collapse mechanisms. Finally, an energy absorption study was performed and an optimum temperature was proposed.

36 MATERIALS SCIENCE↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Developing of the large-bore powder gun for the Nevada test site

Plate-impact experiments on single stage guns provide very planar loading conditions suitable for studying complex phenomena such as phase transitions and material strength, and provide important data useful for constraining and validating predictive models. The objective of the current work was to develop a large-bore (3.5-inches or greater) powder gun capable of accelerating projectiles to moderately high velocities (greater than 2.25 km/s) for impact experiments at Nevada Test Site. This gun will span a performance gap between existing gun facilities and provide a means of examining phenomena over a wide range of stresses and time-scales. Advantages of the large-bore gun include the capability to load multiple samples simultaneously, the use of large diameter samples that significantly extend the time duration of the experiment, and minimal tilt (no bow). This new capability required the development of a disposable confinement system that used an explosively driven closure method to prevent contamination from moving up into the gun system. Experimental results for both the gun system and the explosive valve are presented.

42 ENGINEERING↗

On compression and damage evolution in PTFE and PEEK

The well-known Taylor cylinder impact test, that follows the impact of a flat-ended cylindrical rod onto a rigid stationary anvil, is conducted over a range of impact speeds for two polymers, PTFE and PEEK. In previous work experiments and a model were developed to capture the deformation behavior of the rod after impact. A distinctive feature of these works was that a region in which both spatial and temporal variation of both longitudinal and radial deformation showed evidence of changes in phase within the material. This region is X-ray imaged in a range of impacted targets at the I13 Imaging and Coherence beam line at the Diamond synchrotron. Further techniques were fielded to resolve compressed regions within the recovered polymer cylinders that showed a fracture zone in the impact region. In conclusion, this shows the transit of damage from ductile to brittle failure results from previously undetected internal failure.

36 MATERIALS SCIENCE↗

Assessing the Quality of Molecular Simulations for Vapor–Liquid Equilibria: An Analysis of the TraPPE Database

As molecular modeling and simulation techniques become increasingly important sources of thermophysical property and phase equilibrium data, the ability to assess the robustness of that data becomes more critical. Recently, the use of the compressibility factor (Z) has been suggested as a metric for testing the quality of simulation data for vapor–liquid equilibria (VLE). Int his paper, we analyze predicted VLE data from the transferable potentials for phase equilibria (TraPPE) database and show that, apart from data entry or typographical errors, Z will always be well-behaved in Gibbs ensemble Monte Carlo (GEMC) simulations even when the simulations are not sufficiently equilibrated. However, this is not true for grand canonical Monte Carlo simulations. When the pressure is calculated from the internal forces, then pressure and density are strongly correlated for the vapor phase and, for GEMC simulations, it is recommended to treat Z as an instantaneous mechanical property. From analysis of the TraPPE VLE data, we propose a complementary metric based on the predicted vapor pressures at three neighboring temperatures and their deviation from a local Clausius–Clapeyron fit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficiency and Emissions Characteristics of an HCCI Engine Fueled by Primary Reference Fuels

Here, this article investigates the effects of various primary reference fuel (PRF) blends, compression ratios, and intake temperatures on the thermodynamics and performance of homogeneous charge compression ignition (HCCI) combustion in a Cooperative Fuels Research (CFR) engine. Combustion phasing was kept constant at a CA50 phasing of 5° after top dead center (aTDC) and the equivalence ratio was kept constant at 0.3. Meanwhile, the compression ratio varied from 8:1 to 15:1 as the PRF blends ranged from pure n-heptane to nearly pure isooctane. The intake temperature was used to match CA50 phasing. In addition to the experimental results, a GT-Power model was constructed to simulate the experimental engine and the model was validated against the experimental data. The GT-Power model and simulation results were used to help analyze the energy flows and thermodynamic conditions tested in the experiment. The results indicate that an increase of compression ratio causes higher thermal efficiency and fuel conversion efficiency; however, at the same compression ratio, an increase in PRF number results in lower efficiency due to the required increase in intake temperature and the associated decrease in charge density. While the efficiency does increase with compression ratio, the results show that the effect of increased expansion work is partially offset by higher heat transfer losses and lower ratios of specific heats at higher compression ratios. The results indicate that the maximum pressure rise rate (MPRR) in HCCI significantly increases with compression ratio. Combustion efficiency shows a strong trend with peak temperature regardless of the PRF number or compression ratio, indicating that the CO-to-CO2 conversion is independent of the parent fuel chemistry in the case of the PRFs, whereas the unburned hydrocarbon emissions showed the opposite trend, depending mostly on the parent fuel’s autoignition tendency.

33 ADVANCED PROPULSION SYSTEMS↗

Geotechnical properties of municipal solid waste at different phases of biodegradation

Highlights: > Degraded synthetic municipal solid waste (MSW) anaerobically in controlled bench-scale reactors. > Performed laboratory tests to determine geotechnical properties of MSW at different phases of degradation. > Hydraulic conductivity decreased by two orders of magnitude due to degradation. > Compression ratio reduced from 0.34 for initial fresh waste to 0.15 for the mostly degraded waste. > Friction angle reduced, but cohesion increased with degradation. - Abstract: This paper presents the results of laboratory investigation conducted to determine the variation of geotechnical properties of synthetic municipal solid waste (MSW) at different phases of degradation. Synthetic MSW samples were prepared based on the composition of MSW generated in the United States and were degraded in bioreactors with leachate recirculation. Degradation of the synthetic MSW was quantified based on the gas composition and organic content, and the samples exhumed from the bioreactor cells at different phases of degradation were tested for the geotechnical properties. Hydraulic conductivity, compressibility and shear strength of initial and degraded synthetic MSW were all determined at constant initial moisture content of 50% on wet weight basis. Hydraulic conductivity of synthetic MSW was reduced by two orders of magnitude due to degradation. Compression ratio was reduced from 0.34 for initial fresh waste to 0.15 for the mostly degraded waste. Direct shear tests showed that the fresh and degraded synthetic MSW exhibited continuous strength gain with increase in horizontal deformation, with the cohesion increased from 1 kPa for fresh MSW to 16-40 kPa for degraded MSW and the friction angle decreased from 35{sup o} for fresh MSW to 28{sup o} for degraded MSW. During the triaxial tests under CU condition, the total strength parameters, cohesion and friction angle, were found to vary from 21 to 57 kPa and 1{sup o} to 9{sup o}, respectively, while the effective strength parameters, cohesion and friction angle varied from 18 to 56 kPa and from 1{sup o} to 11{sup o}, respectively. Similar to direct shear test results, as the waste degrades an increase in cohesion and slight decrease in friction angle was observed. Decreased friction angle and increased cohesion with increased degradation is believed to be due to the highly cohesive nature of the synthetic MSW. Variation of synthetic MSW properties from this study also suggests that significant changes in geotechnical properties of MSW can occur due to enhanced degradation induced by leachate recirculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PLANS FOR WARM DENSE MATTER EXPERIMENTS AND IFE TARGET EXPERIMENTS ON NDCX-II

The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL) is currently developing design concepts for NDCX-II, the second phase of the Neutralized Drift Compression Experiment, which will use ion beams to explore Warm Dense Matter (WDM) and Inertial Fusion Energy (IFE) target hydrodynamics. The ion induction accelerator will consist of a new short pulse injector and induction cells from the decommissioned Advanced Test Accelerator (ATA) at Lawrence Livermore National Laboratory (LLNL). To fit within an existing building and to meet the energy and temporal requirements of various target experiments, an aggressive beam compression and acceleration schedule is planned. WDM physics and ion-driven direct drive hydrodynamics will initially be explored with 30 nC of lithium ions in experiments involving ion deposition, ablation, acceleration and stability of planar targets. Other ion sources which may deliver higher charge per bunch will be explored. A test stand has been built at Lawrence Berkeley National Laboratory (LBNL) to test refurbished ATA induction cells and pulsed power hardware for voltage holding and ability to produce various compression and acceleration waveforms. Another test stand is being used to develop and characterize lithium-doped aluminosilicate ion sources. The first experiments will include heating metallic targets to 10,000 K and hydrodynamics studies with cryogenic hydrogen targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

Investigation on Mechanical Properties and Equivalent Model of Aluminum Honeycomb Sandwich Panels

In this study, positive-pressure, bending, and drum peel tests were carried out for aluminum honeycomb sandwich panels made of different materials and with different dimensions. The results of these tests not only precisely revealed the relationships between the mechanical properties of aluminum honeycomb sandwich panels and the material dimensions of the face and core layers, the layout mode of the core layer, and the connecting mode between the face layers and core layers, but also determined the reliable mechanical equivalent model. The test results indicate that when the specimen was subjected to the vertical load, the compression properties of aluminum honeycomb sandwich panels were mainly determined by its core layer, while the face layer mainly relieves the axial stress and restrains the deformation of the core layer. In the flexural test, the face layer is the main part subjected to the load, whereas the core layer shows supporting, stabilizing, and strengthening effects, slowing the deformation of the face layer; flexural-tensile properties can be somewhat affected by the layout type of the core layer. The equivalent plate model, honeycomb plate model, and sandwich panel model were screened based on the experimental results, indicating that the sandwich panel model provided a more accurate description. The sandwich panel model was further modified, ultimately resulting in a more effective equivalent model that can accurately reflect the mechanical properties of the aluminum honeycomb sandwich panels.

36 MATERIALS SCIENCE↗

In-situ imaging of flexure-induced fracture in tape-laminate composites using high-resolution X-ray computed tomography

Here, this study presents development of an in-situ flexure test for imaging progressive inter- and intralaminar fracture in tape-laminate composites using X-ray computed tomography (CT). The intent of this test is to provide detailed experimental observations of ply-level damage that can be used to validate existing, and develop new, progressive damage analysis (PDA) tools. The test consists of a vertically mounted specimen which is flexed using two eccentric compressive loads using an in-situ uniaxial load stage. The flexure specimen contains a starter notch mid-span which promotes initiation of composite failure within the X-ray field of view. Specimens with two different laminate stacking sequences were tested, imaged, analyzed. For a quasi-isotropic laminate with large angle changes between adjacent plies, there was near simultaneous growth of transverse cracks and delaminations below the midplane of the laminate. For a laminate with small angles between adjacent plies, there was extensive formation of transverse crack networks which penetrated the laminate thickness without delamination growth. In addition to imaging fracture, the X-ray CT data from both specimen types were used to quantify the variability in thickness and analyze the local orientation of individual plies. Overall, the proposed test and the image-data analysis methodology provided an important insight into the fracture processes in tape laminates and highlights the inherent ply-level geometrical variabilities that should be accounted for in PDA simulations.

42 ENGINEERING↗